916 resultados para Rotarod Performance Test


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to examine the acute effects of endurance exercise on jumping and kicking performance in young soccer players. Twenty-one top-class young soccer players (16.1±0.2 years) performed a countermovement jump test and a maximal instep soccer kick test before and after running for 20 min on a treadmill at 80% of their individual maximum heart rate. Two force platforms were used to obtain the following parameters during the countermovement jump: jump height, maximum power, maximum power relative to body mass, maximum vertical ground reaction force, maximum vertical ground reaction force relative to body mass, and maximum vertical ground reaction force applied to each leg. Maximum vertical ground reaction force and maximum vertical ground reaction force relative to body mass applied to the support leg during the kicks were also calculated with a force platform. The kicking motion was recorded using a three-dimensional motion-capture system. Maximum velocity of the ball, maximum linear velocity of the toe, ankle, knee and hip, and linear velocity of the toe at ball contact during the kicks were calculated. Non-significant differences were found in the parameters measured during the countermovement jump and the maximal instep soccer kick test before and after running, suggesting that the jumping and kicking performances of top-class young soccer players were not significantly affected after 20 min treadmill running at 80% of their individual maximum heart rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A small Positron Emission Tomography demonstrator based on LYSO slabs and Silicon Photomultiplier matrices is under construction at the University and INFN of Pisa. In this paper we present the characterization results of the read-out electronics and of the detection system. Two SiPM matrices, composed by 8 × 8 SiPM pixels, 1.5 mm pitch, have been coupled one to one to a LYSO crystals array. Custom Front-End ASICs were used to read the 64 channels of each matrix. Data from each Front-End were multiplexed and sent to a DAQ board for the digital conversion; a motherboard collects the data and communicates with a host computer through a USB port. Specific tests were carried out on the system in order to assess its performance. Futhermore we have measured some of the most important parameters of the system for PET application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigated the changes in cardiorespiratory response and running performance of 9 male ?Talent Identification? (TID) and 6 male Senior Elite (SE) Spanish National Squad triathletes during a specific cycle-run test. The TID and SE triathletes (initial age 15.2±0.7 vs. 23.8±5.6 years, p=0.03; tests through the competitive period and the preparatory period, respectively, of two consecutive seasons: Test 1 was an incremental cycle test to determine the ventilatory threshold (Thvent); Test 2 (C-R) was 30 min constant load cycling at the Thvent power output followed by a 3-km time trial run; and Test 3 (R) was an isolated 3-km time trial control run, in randomized counterbalanced order. In both seasons the time required to complete the C-R 3-km run was greater than for R in TID (11:09±00:24 vs. 10:45±00:16 min:ss, pmenor que 0.01; and 10:24±00:22 vs. 10:04±00:14, p=0.006, for season 2005/06 and 2006/07, respectively) and SE (10:15±00:19 vs. 09:45±00:30, pmenor que 0.001 and 09:51±00:26 vs. 09:46±00:06, p= 0.02 for season 2005/06 and 2006/07, respectively). Compared to the first season, completion of the time trial run was faster in the second season (6.6%, pmenor que 0.01 and 6.4%, pmenor que 0.01, for C-R and R test, respectively) only in TID. Changes in post-cycling run performance were accompanied by changes in pacing strategy but only slight or non-significant changes in the cardiorespiratory response. Thus, the negative effect of cycling on performance may persist, independently of the period, over two consecutive seasons in TID and SE triathletes; however A improvements over time suggests that monitoring running pacing strategy after cycling may be a useful tool to control performance and training adaptations in TID. O2max 77.0±5.6 vs. 77.8±3.6 mL·kg-1·min-1, NS) underwent three TE D EP C C

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Models based on degradation are powerful and useful tools to evaluate the reliability of those devices in which failure happens because of degradation in the performance parameters. This paper presents a procedure for assessing the reliability of concentrator photovoltaic (CPV) modules operating outdoors in real-time conditions. With this model, the main reliability functions are predicted. This model has been applied to a real case with a module composed of GaAs single-junction solar cells and total internal reflection (TIR) optics

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to examine the effect of sodium bicarbonate ingestion on consecutive "all out" sprint tests, analyzing the acid-base status and its influence on performance and perceived effort. Ten elite bicycle motocross (BMX) riders (20.7 ± 1.4 years, training experience 8-12 years) participated in this study which consisted of two trials. Each trial consisted of three consecutive Wingate tests (WTs) separated by 15 min recovery. Ninety minutes prior to exercise subjects ingested either NaHCO(3) (-) (0.3 g kg(-1) body weight) or placebo. Blood samples were collected for the assessment of blood acid-base status: bicarbonate concentration ([HCO(3) (-)]), pH, base excess (BE) and blood lactate concentration ([La(-)]). Performance variables of peak power (PP), mean power (MP), time to peak power and fatigue index were calculated for each sprint. Significant differences (p < 0.05) were observed in acid-base variables [pH before WT1: 7.47 ± 0.05 vs. 7.41 ± 0.03; [HCO(3) (-)] before WT1: 29.08 ± 2.27 vs. 22.85 ± 0.24 mmol L(-1) (bicarbonate vs. placebo conditions, respectively)], but there were not significant differences in performance variables between trials [PP WT1: 1,610 ± 373 vs. 1,599 ± 370 W; PP WT2: 1,548 ± 460 vs. 1,570 ± 428 W; PP WT3: 1,463 ± 361 vs. 1,519 ± 364 W. MP WT1: 809 ± 113 vs. 812 ± 108 W; MP WT2: 799 ± 135 vs. 799 ± 124 W; MP WT3: 762 ± 165 vs. 782 ± 118 W (bicarbonate vs. placebo conditions, respectively)]. Rating of perceived effort (RPE) was not influenced nor ratings of perceived readiness. Sodium bicarbonate ingestion modified significantly the blood acid-base balance, although the induced alkalosis did not improve the Wingate test performance, RPE and perceived readiness across three consecutive WTs in elite BMX cyclists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we will see how the efficiency of the MBS simulations can be improved in two different ways, by considering both an explicit and implicit semi-recursive formulation. The explicit method is based on a double velocity transformation that involves the solution of a redundant but compatible system of equations. The high computational cost of this operation has been drastically reduced by taking into account the sparsity pattern of the system. Regarding this, the goal of this method is the introduction of MA48, a high performance mathematical library provided by Harwell Subroutine Library. The second method proposed in this paper has the particularity that, depending on the case, between 70 and 85% of the computation time is devoted to the evaluation of forces derivatives with respect to the relative position and velocity vectors. Keeping in mind that evaluating these derivatives can be decomposed into concurrent tasks, the main goal of this paper lies on a successful and straightforward parallel implementation that have led to a substantial improvement with a speedup of 3.2 by keeping all the cores busy in a quad-core processor and distributing the workload between them, achieving on this way a huge time reduction by doing an ideal CPU usage

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article examines, from the energy viewpoint, a new lightweight, slim, high energy efficient, light-transmitting envelope system, providing for seamless, free-form designs for use in architectural projects. The research was based on envelope components already existing on the market, especially components implemented with granular silica gel insulation, as this is the most effective translucent thermal insulation there is today. The tests run on these materials revealed that there is not one that has all the features required of the new envelope model, although some do have properties that could be exploited to generate this envelope, namely, the vacuum chamber of vacuum insulated panels (VIP), the monolithic aerogel used as insulation in some prototypes, reinforced polyester barriers. By combining these three design components — the high-performance thermal insulation of the vacuum chamber combined with monolithic silica gel insulation, the free-form design potential provided by materials like reinforced polyester and epoxy resins—, we have been able to define and test a new, variable geometry, energy-saving envelope system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SIMLIDAR is an application developed in Cþþ that generates an artificial orchard using a Lindenmayer system. The application simulates the lateral interaction between the artificial orchard and a laser scanner or LIDAR (Light Detection and Ranging). To best highlight the unique qualities of the LIDAR simulation, this work focuses on apple trees without leaves, i.e. the woody structure. The objective is to simulate a terrestrial laser sensor (LIDAR) when applied to different artificially created orchards and compare the simulated characteristics of trees with the parameters obtained with the LIDAR. The scanner is mounted on a virtual tractor and measures the distance between the origin of the laser beam and the nearby plant object. This measurement is taken with an angular scan in a plane which is perpendicular to the route of the virtual tractor. SIMLIDAR determines the distance measured in a bi-dimensional matrix N M, where N is the number of angular scans and M is the number of steps in the tractor route. In order to test the data and performance of SIMLIDAR, the simulation has been applied to 42 different artificial orchards. After previously defining and calculating two vegetative parameters (wood area and wood projected area) of the simulated trees, a good correlation (R2 ¼ 0.70e0.80) was found between these characteristics and the wood area detected (impacted) by the laser beam. The designed software can be valuable in horticulture for estimating biomass and optimising the pesticide treatments that are performed in winter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gasification is a technology that can replace traditional management alternatives used up to date to deal with this waste (landfilling, composting and incineration) and which fulfils the social, environmental and legislative requirements. The main products of sewage sludge gasification are permanent gases (useful to generate energy or to be used as raw material in chemical synthesis processes), liquids (tars) and char. One of the main problems to be solved in gasification is tar production. Tars are organic impurities which can condense at relatively high temperatures making impossible to use the produced gases for most applications. This work deals with the effect of some primary tar removal processes (performed inside the gasifier) on sewage sludge gasification products. For this purpose, analysis of the gas composition, tar production, cold gas efficiency and carbon conversion were carried out. The tests were performed with air in a laboratory scale plant consisting mainly of a bubbling bed gasifier. No catalyzed and catalyzed (10% wt of dolomite in the bed and in the feeding) tests were carried out at different temperatures (750ºC, 800ºC and 850ºC) in order to know the effect of these parameters in the gasification products. As far as tars were concerned, qualitative and quantitative tar composition was determined. In all tests the Equivalence Ratio (ER) was kept at 0.3. Temperature is one of the most influential variables in sewage sludge gasification. Higher temperatures favoured hydrogen and CO production while CO2 content decreased, which might be partially explained by the effect of the cracking, Boudouard and CO2 reforming reactions. At 850ºC, cold gas efficiency and carbon conversion reached 49% and 76%, respectively. The presence of dolomite as catalyst increased the production of H2 reaching contents of 15.5% by volume at 850 °C. Similar behaviour was found for CO whereas CO2 and CnHm (light hydrocarbons) production decreased. In the presence of dolomite, a tar reduction of up to 51% was reached in comparison with no catalyzed tests, as well as improvements on cold gas efficiency and carbon conversion. Several assays were developed in order to test catalyst performance under more rough gasification conditions. For this purpose, the throughput value (TR), defined as kg sludge “as received” fed to the gasifier per hour and per m2 of cross sectional area of the gasifier, was modified. Specifically, the TR values used were 110 (reference value), 215 and 322 kg/h·m2. When TR increased, the H2, CO and CH4 production decreased while the CO2 and the CnHm production increased. Tar production increased drastically with TR during no catalysed tests what is related to the lower residence time of the gas inside the reactor. Nevertheless, even at TR=322 kg/h·m2, tar production decreased by nearly 50% with in-bed use of dolomite in comparison with no catalyzed assays under the same operating conditions. Regarding relative tar composition, there was an increase in benzene and naphthalene content when temperature increased while the content of the rest of compounds decreased. The dolomite seemed to be effective all over the range of molecular weight studied showing tar removal efficiencies between 35-55% in most cases. High values of the TR caused a significant increase in tar production but a slight effect on tar composition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this report is to build a model that represents, as best as possible, the seismic behavior of a pile cap bridge foundation by a nonlinear static (analysis) procedure. It will consist of a reproduction of a specimen already built in the laboratory. This model will carry out a pseudo static lateral and horizontal pushover test that will be applied onto the pile cap until the failure of the structure, the formation of a plastic hinge in the piles due to the horizontal deformation, occurs. The pushover test consists of increasing the horizontal load over the pile cap until the horizontal displacement wanted at the height of the pile cap is reached. The output of this model will be a Skeleton curve that will plot the lateral load (kN) over the displacement (m), so that the maximum movement the pile cap foundation can reach before its failure can be calculated. This failure will be achieved when the load at that specific shift is equal to 85% of the maximum. The pile cap foundation finite element model was based on pile cap built for a laboratory experiment already carried out by the Master student Deming Zhang at Tongji University. Two different pile caps were tested with a difference in height above the ground level. While one has 0:3m, the other rises 0:8m above the ground level. The computer model was calibrated using the experimental results. The pile cap foundation will be programmed in a finite element environment called OpenSees (Open System for Earthquake Engineering Simulation [28]). This environment is a free software developed by Berkeley University specialized, as it name says, in the study of earthquakes and its effects on structures. This specialization is the main reason why it is being used for building this model as it makes it possible to build any finite element model, and perform several analysis in order to get the results wanted. The development of OpenSees is sponsored by the Pacific Earthquake Engineering Research Center through the National Science Foundation engineering and education centers program. OpenSees uses Tcl language to program it, which is a language similar to C++.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

NASA's tether experiment ProSEDS will be placed in orbit on board a Delta-II rocket in early 2003. ProSEDS will test bare-tether electron collection, deorbiting of the rocket second stage, and the system dynamic stability. ProSEDS performance will vary both because ambient conditions change along the orbit and because tether-circuit parameters follow a step by step sequence in the current operating cycle. In this work we discuss how measurements of tether current and bias, plasma density, and deorbiting rate can be used to check the OML law for current collection. We review circuit bulk elements; characteristic lengths and energies that determine collection (tether radius, electron thermal gyroradius and Debye length, particle temperatures, tether bias, ion ram energy); and lengths determining current and bias profiles along the tether (extent of magnetic self-field, a length gauging ohmic versus collection impedances, tether length). The analysis serves the purpose of estimating ProSEDS behavior in orbit and fostering our ability for extrapolating ProSEDS flight data to different tether and environmental conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Providing QoS in the context of Ad Hoc networks includes a very wide field of application from the perspective of every level of the architecture in the network.In order for simulation studies to be useful, it is very important that the simulation results match as closely as possible with the test bed results. In this Paper, we study the throughput performance (parameter QoS) in Mobile Ad Hoc Networks (MANETs) and compares emulated test bed results with simulation results from NS2 (Network Simulator). The performance of the Mobile Ad Hoc Networks is very sensitive to the number of users and the offered load. When the number of users/offered load is high then the collisions increase resulting in larger wastage of the medium and lowering overall throughput. The aim of this research is to compare the throughput of Mobile Ad Hoc Networks using three different scenarios: 97, 100 and 120 users (nodes) using simulator NS2. By analyzing the graphs in MANETs, it is concluded When the number of users o nodes is increased beyond the certain limit, throughput decreases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present and validate a test able to provide reliable body sway measurements in air pistol shooting, without the use of a gun. 46 senior male pistol shooters who participated in Spanish air pistol championships participated in the study. Body sway data of two static bipodal balance tests have been compared: during the first test, shooting was simulated by use of a dumbbell, while during the second test the shooters own pistol was used. Both tests were performed the day previous to the competition, during the official training time and at the training stands to simulate competition conditions. The participants performance was determined as the total score of 60 shots at competition. Apart from the commonly used variables that refer to movements of the shooters centre of pressure (COP), such as COP displacements on the X and Y axes, maximum and average COP velocities and total COP area, the present analysis also included variables that provide information regarding the axes of the COP ellipse (length and angle in respect to X). A strong statistically significant correlation between the two tests was found (with an interclass correlation varying between 0.59 and 0.92). A statistically significant inverse linear correlation was also found between performance and COP movements. The study concludes that dumbbell tests are perfectly valid for measuring body sway by simulating pistol shooting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A study on a water- ow window installed in a test box is presented. This window is composed of two glass panes separated by a chamber through water ows. The ow of water comes from an isolated tank which contains heat water. In order to fully evaluate the water- ow window performance for different room and window sizes, locations and weather conditions, a mathematical model of the whole box is needed. The proposed model, in which conduction heat transfer mechanism is the only considered, is one dimensional and unsteady based upon test box energy balance. The effect of the heat water tank, which feeds the water- ow window, is included in the model by means of a time delay in the source term. Although some previous work about moving uid chamber has been developed, air was used as heat transfer uid and no uid storage was considered. Finally a comparison between the numerical solution and the obtained experimental data is done.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Un caloducto en bucle cerrado o Loop Heat Pipe (LHP) es un dispositivo de transferencia de calor cuyo principio de operación se basa en la evaporación/condensación de un fluido de trabajo, que es bombeado a través de un circuito cerrado gracias a fuerzas de capilaridad. Gracias a su flexibilidad, su baja masa y su mínimo (incluso nulo) consumo de potencia, su principal aplicación ha sido identificada como parte del subsistema de control térmico de vehículos espaciales. En el presente trabajo se ha desarrollado un LHP capaz de funcionar eficientemente a temperaturas de hasta 125 oC, siguiendo la actual tendencia de los equipos a bordo de satélites de incrementar su temperatura de operación. En la selección del diseño optimo para dicho LHP, la compatibilidad entre materiales y fluido de trabajo se identificó como uno de los puntos clave. Para seleccionar la mejor combinación, se llevó a cabo una exhaustiva revisión del estado del arte, además de un estudio especifico que incluía el desarrollo de un banco de ensayos de compatibilidad. Como conclusión, la combinación seleccionada como la candidata idónea para ser integrada en el LHP capaz de operar hasta 125 oC fue un evaporador de acero inoxidable, líneas de titanio y amoniaco como fluido de trabajo. En esa línea se diseñó y fabricó un prototipo para ensayos y se desarrolló un modelo de simulación con EcosimPro para evaluar sus prestaciones. Se concluyó que el diseño era adecuado para el rango de operación definido. La incompatibilidad entre el fluido de trabajo y los materiales del LHP está ligada a la generación de gases no condensables. Para un estudio más detallado de los efectos de dichos gases en el funcionamiento del LHP se analizó su comportamiento con diferentes cantidades de nitrógeno inyectadas en su cámara de compensación, simulando un gas no condensable formado en el interior del dispositivo. El estudio se basó en el análisis de las temperaturas medidas experimentalmente a distintos niveles de potencia y temperatura de sumidero o fuente fría. Adicionalmente, dichos resultados se compararon con las predicciones obtenidas por medio del modelo en EcosimPro. Las principales conclusiones obtenidas fueron dos. La primera indica que una cantidad de gas no condensable más de dos veces mayor que la cantidad generada al final de la vida de un satélite típico de telecomunicaciones (15 años) tiene efectos casi despreciables en el funcionamiento del LHP. La segunda es que el principal efecto del gas no condensable es una disminución de la conductancia térmica, especialmente a bajas potencias y temperaturas de sumidero. El efecto es más significativo cuanto mayor es la cantidad de gas añadida. Asimismo, durante la campaña de ensayos se observó un fenómeno no esperado para grandes cantidades de gas no condensable. Dicho fenómeno consiste en un comportamiento oscilatorio, detectado tanto en los ensayos como en la simulación. Este efecto es susceptible de una investigación más profunda y los resultados obtenidos pueden constituir la base para dicha tarea. ABSTRACT Loop Heat Pipes (LHPs) are heat transfer devices whose operating principle is based on the evaporation/condensation of a working fluid, and which use capillary pumping forces to ensure the fluid circulation. Thanks to their flexibility, low mass and minimum (even null) power consumption, their main application has been identified as part of the thermal control subsystem in spacecraft. In the present work, an LHP able to operate efficiently up to 125 oC has been developed, which is in line with the current tendency of satellite on-board equipment to increase their operating temperatures. In selecting the optimal LHP design for the elevated temperature application, the compatibility between the materials and working fluid has been identified as one of the main drivers. An extensive literature review and a dedicated trade-off were performed, in order to select the optimal combination of fluids and materials for the LHP. The trade-off included the development of a dedicated compatibility test stand. In conclusion, the combination of stainless steel evaporator, titanium piping and ammonia as working fluid was selected as the best candidate to operate up to 125 oC. An LHP prototype was designed and manufactured and a simulation model in EcosimPro was developed to evaluate its performance. The first conclusion was that the defined LHP was suitable for the defined operational range. Incompatibility between the working fluid and LHP materials is linked to Non Condensable Gas (NCG) generation. Therefore, the behaviour of the LHP developed with different amounts of nitrogen injected in its compensation chamber to simulate NCG generation, was analyzed. The LHP performance was studied by analysis of the test results at different temperatures and power levels. The test results were also compared to simulations in EcosimPro. Two additional conclusions can be drawn: (i) the effects of an amount of more than two times the expected NCG at the end of life of a typical telecommunications satellite (15 years) is almost negligible on the LHP operation, and (ii) the main effect of the NCG is a decrease in the LHP thermal conductance, especially at low temperatures and low power levels. This decrease is more significant with the progressive addition of NCG. An unexpected phenomenon was observed in the LHP operation with large NCG amounts. Namely, an oscillatory behaviour, which was observed both in the tests and the simulation. This effect provides the basis for further studies concerning oscillations in LHPs.