990 resultados para Root canal filling material


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The usefulness of fluoride-releasing restorations in secondary caries prevention may be questioned because of the presence of other common sources of fluoride and because of ageing of the restorations. This study tested the hypothesis that glass-ionomer cement restorations, either aged or unaged, do not prevent secondary root caries, when fluoride dentifrice is frequently used. Sixteen volunteers wore palatal appliances in two phases of 14 days, according to a 2 x 2 crossover design. In each phase the appliance was loaded with bovine root dentine slabs restored with either glass-ionomer or resin composite, either aged or unaged. Specimens were exposed to cariogenic challenge 4 times/day and to fluoridated dentifrice 3 times/day. The fluoride content in the biofilm (FB) formed on slabs and the mineral loss (Delta Z) around the restorations were analysed. No differences were found between restorative materials regarding the FB and the Delta Z, for either aged (p = 0.792 and p = 0.645, respectively) or unaged (p = 1.00 and p = 0.278, respectively) groups. Under the cariogenic and fluoride dentifrice exposure conditions of this study, the glass-ionomer restoration, either aged or unaged, did not provide additional protection against secondary root caries. Copyright (c) 2006 S. Karger AG, Basel.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

En la presente investigación se analiza la causa del hundimiento del cuarto compartimento del Tercer Depósito del Canal de Isabel II el 8 de abril de 1905, uno de los más graves de la historia de la construcción en España: fallecieron 30 personas y quedaron heridas otras 60. El Proyecto y Construcción de esta estructura era de D. José Eugenio Ribera, una de las grandes figuras de la ingeniería civil en nuestro país, cuya carrera pudo haber quedado truncada como consecuencia del siniestro. Dado el tiempo transcurrido desde la ocurrencia de este accidente, la investigación ha partido de la recopilación de la información relativa al Proyecto y a la propia construcción de la estructura, para revisar a continuación la información disponible sobre el hundimiento. De la construcción de la cubierta es interesante destacar la atrevida configuración estructural, cubriéndose una inmensa superficie de 74.000 m2 mediante una sucesión de bóvedas de hormigón armado de tan sólo 5 cm de espesor y un rebajamiento de 1/10 para salvar una luz de 6 m, que apoyaban en pórticos del mismo material, con pilares también muy esbeltos: 0,25 m de lado para 8 m de altura. Y todo ello en una época en la que la tecnología y conocimiento de las estructuras con este "nuevo" material se basaban en buena medida en el desarrollo de patentes. En cuanto a la información sobre el hundimiento, llama la atención en primer lugar la relevancia de los técnicos, peritos y letrados que intervinieron en el juicio y en el procedimiento administrativo posterior, poniéndose de manifiesto la trascendencia que el accidente tuvo en su momento y que, sin embargo, no ha trascendido hasta nuestros días. Ejemplo de ello es el papel de Echegaray -primera figura intelectual de la época- como perito en la defensa de Ribera, de D. Melquiades Álvarez -futuro presidente del Congreso- como abogado defensor, el General Marvá -uno de los máximos exponentes del papel de los ingenieros militares en la introducción del hormigón armado en nuestro país-, que presidiría la Comisión encargada del peritaje por parte del juzgado, o las opiniones de reconocidas personalidades internacionales del "nuevo" material como el Dr. von Emperger o Hennebique. Pero lo más relevante de dicha información es la falta de uniformidad sobre lo que pudo ocasionar el hundimiento: fallos en los materiales, durante la construcción, defectos en el diseño de la estructura, la realización de unas pruebas de carga cuando se concluyó ésta, etc. Pero la que durante el juicio y en los Informes posteriores se impuso como causa del fallo de la estructura fue su dilatación como consecuencia de las altas temperaturas que se produjeron aquella primavera. Y ello a pesar de que el hundimiento ocurrió a las 7 de la mañana... Con base en esta información se ha analizado el comportamiento estructural de la cubierta, permitiendo evaluar el papel que diversos factores pudieron tener en el inicio del hundimiento y en su extensión a toda la superficie construida, concluyéndose así cuáles fueron las causas del siniestro. De los resultados obtenidos se presta especial atención a las enseñanzas que se desprenden de la ocurrencia del hundimiento, enfatizándose en la relevancia de la historia -y en particular de los casos históricos de error- para la formación continua que debe existir en la Ingeniería. En el caso del hundimiento del Tercer Depósito algunas de estas "enseñanzas" son de plena actualidad, tales como la importancia de los detalles constructivos en la "robustez" de la estructuras, el diseño de estructuras "integrales" o la vigilancia del proceso constructivo. Por último, la investigación ha servido para recuperar, una vez más, la figura de D. José Eugenio Ribera, cuyo papel en la introducción del hormigón armado en España fue decisivo. En la obra del Tercer Depósito se arriesgó demasiado, y provocó un desastre que aceleró la transición hacia una nueva etapa en el hormigón estructural al abrigo de un mayor conocimiento científico y de las primeras normativas. También en esta etapa sería protagonista. This dissertation analyses the cause of the collapse of the 4th compartment of the 3th Reservoir of Canal de Isabel II in Madrid. It happened in 1905, on April 8th, being one of the most disastrous accidents occurred in the history of Spanish construction: 30 people died and 60 were injured. The design and construction supervision were carried out by D. José Eugenio Ribera, one of the main figures in Civil Engineering of our country, whose career could have been destroyed as a result of this accident. Since it occurred more than 100 years ago, the investigation started by compiling information about the structure`s design and construction, followed by reviewing the available information about the accident. With regard to the construction, it is interesting to point out its daring structural configuration. It covered a huge area of 74.000 m2 with a series of reinforced concrete vaults with a thickness of not more than 5 cm, a 6 m span and a rise of 1/10th. In turn, these vaults were supported by frames composed of very slender 0,25 m x 0,25 m columns with a height of 8 m. It is noteworthy that this took place in a time when the technology and knowledge about this "new" material was largely based on patents. In relation to the information about the collapse, its significance is shown by the important experts and lawyers that were involved in the trial and the subsequent administrative procedure. For example, Echegaray -the most important intellectual of that time- defended Ribera, Melquiades Álvarez –the future president of the Congress- was his lawyer, and General Marvá -who represented the important role of the military engineers in the introduction of reinforced concrete in our country-, led the Commission that was put in charge by the judge of the root cause analysis. In addition, the matter caught the interest of renowned foreigners like Dr. von Emperger or Hennebique and their opinions had a great influence. Nonetheless, this structural failure is unknown to most of today’s engineers. However, what is most surprising are the different causes that were claimed to lie at the root of the disaster: material defects, construction flaws, errors in the design, load tests performed after the structure was finished, etc. The final cause that was put forth during the trial and in the following reports was attributed to the dilatation of the roof due to the high temperatures that spring, albeit the collapse occurred at 7 AM... Based on this information the structural behaviour of the roof has been analysed, which allowed identifying the causes that could have provoked the initial failure and those that could have led to the global collapse. Lessons have been learned from these results, which points out the relevance of history -and in particular, of examples gone wrong- for the continuous education that should exist in engineering. In the case of the 3th Reservoir some of these lessons are still relevant during the present time, like the importance of detailing in "robustness", the design of "integral" structures or the due consideration of construction methods. Finally, the investigation has revived, once again, the figure of D. José Eugenio Ribera, whose role in the introduction of reinforced concrete in Spain was crucial. With the construction of the 3th Reservoir he took too much risk and caused a disaster that accelerated the transition to a new era in structural concrete based on greater scientific knowledge and the first codes. In this new period he would also play a major role.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre no Instituto Superior de Ciências da Saúde Egas Moniz

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis addresses various aspects related to silos, from the strength of some structural parts to internal actions due to grain. Two hopper silo models were mainly studied, so the thesis is divided into two parts. The first part focuses only on the silo cylinder and deals with the collapse of a silo due to failure of the vertical walls. We had the opportunity to access data from a real silo and perform tensile tests on corrugated sheets. The theoretical and experimental resistance of the corrugated sheet forming the silo cylinder was studied. The resistance was then compared with the internal actions due to grain prescribed by various standards. The second part, however, focused on the hopper of a silo in which a load test (loading and unloading of the silo) was performed. Through the test data, an attempt was made to reproduce the pressures normal to the hopper through analytical reasoning. The experimental pressures were then compared with the theoretical pressures predicted by the standards. In addition, with mathematical reasoning, an attempt was made to reproduce the horizontal pressure on the vertical walls of the silo from the experimental normal pressure in the hopper. In fact, the test was related only to the hopper part and not to the silo cylinder.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In old, phosphorus (P)-impoverished habitats, root specializations such as cluster roots efficiently mobilize and acquire P by releasing large amounts of carboxylates in the rhizosphere. These specialized roots are rarely mycorrhizal. We investigated whether Discocactus placentiformis (Cactaceae), a common species in nutrient-poor campos rupestres over white sands, operates in the same way as other root specializations. Discocactus placentiformis showed no mycorrhizal colonization, but exhibited a sand-binding root specialization with rhizosheath formation. We first provide circumstantial evidence for carboxylate exudation in field material, based on its very high shoot manganese (Mn) concentrations, and then firm evidence, based on exudate analysis. We identified predominantly oxalic acid, but also malic, citric, lactic, succinic, fumaric, and malonic acids. When grown in nutrient solution with P concentrations ranging from 0 to 100 μM, we observed an increase in total carboxylate exudation with decreasing P supply, showing that P deficiency stimulated carboxylate release. Additionally, we tested P solubilization by citric, malic and oxalic acids, and found that they solubilized P from the strongly P-sorbing soil in its native habitat, when the acids were added in combination and in relatively low concentrations. We conclude that the sand-binding root specialization in this nonmycorrhizal cactus functions similar to that of cluster roots, which efficiently enhance P acquisition in other habitats with very low P availability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The identification of the mandibular canal (MC) is an important prerequisite for surgical procedures involving the posterior mandible. Cone beam computed tomography (CBCT) represents an advance in imaging technology, but distinguishing the MC from surrounding structures may remain a delicate task. OBJECTIVES: The aim of this study was to assess the visibility of the MC in different regions on CBCT cross-sectional images. MATERIAL AND METHODS: CBCT cross-sectional images of 58 patients (116 hemi-mandibles) were analyzed, and the visibility of the MC in different regions was assessed. RESULTS: The MC was clearly visible in 53% of the hemi-mandibles. Difficult and very difficult visualizations were registered in 25% and 22% of the hemi-mandibles, respectively. The visibility of the MC on distal regions was superior when compared to regions closer to the mental foramen. No differences were found between edentulous and tooth-bearing areas. CONCLUSIONS: The MC presents an overall satisfactory visibility on CBCT cross-sectional images in most cases. However, the discrimination of the canal from its surrounds becomes less obvious towards the mental foramen region when cross-sectional images are individually analyzed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUÇÃO: Hidrelétricas alteram o fluxo das águas e provocam impactos sobre a composição de mosquitos, justificando-se essa pesquisa. O objetivo da pesquisa foi estudar anofelinos de área sob a influência de um novo lago e avaliar a vulnerabilidade relativa à malária. MÉTODOS: Foram feitas coletas de Anopheles nas margens da Represa Porto Primavera, durante as fases do alagamento até sua cota máxima. Utilizaram-se as técnicas: atrativa humana, de armadilha de Shannon e concha entomológica. Os indicadores Riqueza e Diversidade foram utilizados para medir o impacto. A análise das distribuições temporais foi realizada pelo teste Mann-Whitney, considerando localidade, cota e método de captura como variáveis independentes (α=0,05). RESULTADOS: A densidade de Anopheles darlingi oscilou entre as localidades A, B e C, sendo que os maiores picos foram para B e C. Com a estabilidade do lago, no último nível, evidenciou-se a tendência de redução da densidade de Anopheles darlingi. CONCLUSÕES: Sugere-se que o risco de autoctonia de malária nas proximidades do lago permanece inalterado, ficando o alerta para esporádicas infecções humanas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The purpose of this study was to assess the efficacy of Er:YAG laser energy for composite resin removal and the influence of pulse repetition rate on the thermal alterations occurring during laser ablation. Materials and Methods: Composite resin filling was placed in cavities (1.0 mm deep) prepared in bovine teeth and the specimens were randomly assigned to five groups according to the technique used for composite filling removal. In group I (controls), the restorations were removed using a high-speed diamond bur. In the other groups, the composite fillings were removed using an Er: YAG laser with different pulse repetition rates: group 2-2 Hz; group 3-4 Hz; group 4-6 Hz; and group 5-10 Hz. The time required for complete removal of the restorative material and the temperature changes were recorded. Results: Temperature rise during composite resin removal with the Er: YAG laser occurred in the substrate underneath the restoration and was directly proportional to the increase in pulse repetition rate. None of the groups had a temperature increase during composite filling removal of more than 5.6 degrees C, which is considered the critical point above which irreversible thermal damage to the pulp may result. Regarding the time for composite filling removal, all the laser-ablated groups (except for group 5 [10 Hz]) required more time than the control group for complete elimination of the material from the cavity walls. Conclusion: Under the tested conditions, Er: YAG laser irradiation was efficient for composite resin ablation and did not cause a temperature increase above the limit considered safe for the pulp. Among the tested pulse repetition rates, 6 Hz produced minimal temperature change compared to the control group (high-speed bur), and allowed composite filling removal within a time period that is acceptable for clinical conditions.