985 resultados para RADIAL-VELOCITIES
Resumo:
Health promotion in hospital environments can be improved using the most recent information and communication technologies. The Internet connectivity to small sensor nodes carried by patients allows remote access to their bio-signals. To promote these features the healthcare wireless sensor networks (HWSN) are used. In these networks mobility support is a key issue in order to keep patients under realtime monitoring even when they move around. To keep sensors connected to the network, they should change their access points of attachment when patients move to a new coverage area along an infirmary. This process, called handover, is responsible for continuous network connectivity to the sensors. This paper presents a detailed performance evaluation study considering three handover mechanisms for healthcare scenarios (Hand4MAC, RSSI-based, and Backbone-based). The study was performed by simulation using several scenarios with different number of sensors and different moving velocities of sensor nodes. The results show that Hand4MAC is the best solution to guarantee almost continuous connectivity to sensor nodes with less energy consumption.
Resumo:
In the last two decades, small strain shear modulus became one of the most important geotechnical parameters to characterize soil stiffness. Finite element analysis have shown that in-situ stiffness of soils and rocks is much higher than what was previously thought and that stress-strain behaviour of these materials is non-linear in most cases with small strain levels, especially in the ground around retaining walls, foundations and tunnels, typically in the order of 10−2 to 10−4 of strain. Although the best approach to estimate shear modulus seems to be based in measuring seismic wave velocities, deriving the parameter through correlations with in-situ tests is usually considered very useful for design practice.The use of Neural Networks for modeling systems has been widespread, in particular within areas where the great amount of available data and the complexity of the systems keeps the problem very unfriendly to treat following traditional data analysis methodologies. In this work, the use of Neural Networks and Support Vector Regression is proposed to estimate small strain shear modulus for sedimentary soils from the basic or intermediate parameters derived from Marchetti Dilatometer Test. The results are discussed and compared with some of the most common available methodologies for this evaluation.
Resumo:
In the last two decades, small strain shear modulus became one of the most important geotechnical parameters to characterize soil stiffness. Finite element analysis have shown that in-situ stiffness of soils and rocks is much higher than what was previously thought and that stress-strain behaviour of these materials is non-linear in most cases with small strain levels, especially in the ground around retaining walls, foundations and tunnels, typically in the order of 10−2 to 10−4 of strain. Although the best approach to estimate shear modulus seems to be based in measuring seismic wave velocities, deriving the parameter through correlations with in-situ tests is usually considered very useful for design practice.The use of Neural Networks for modeling systems has been widespread, in particular within areas where the great amount of available data and the complexity of the systems keeps the problem very unfriendly to treat following traditional data analysis methodologies. In this work, the use of Neural Networks and Support Vector Regression is proposed to estimate small strain shear modulus for sedimentary soils from the basic or intermediate parameters derived from Marchetti Dilatometer Test. The results are discussed and compared with some of the most common available methodologies for this evaluation.
Resumo:
Introducção e objetivos: Foi nosso objetivo estudar as tendências da intervencção coronária percutânea entre 2004-2013 e comparar Portugal com outros países europeus. Métodos: Análise dos procedimentos coronários efetuados entre 2004-2013 com base num registo prospetivo, multicêntrico, voluntário, doente a doente --- Registo Nacional de Cardiologia de Intervenc¸ão (RNCI) da Associac¸ão Portuguesa de Intervenc¸ão Cardiovascular da Sociedade Portuguesa de Cardiologia (APIC-SPC) --- e dos dados oficiais publicados pela Direc¸ão Geral de Saúde (DGS). Resultados: Em 2013 realizaram-se 36 810 cateterismos diagnósticos (3529 coronariografias por milhão de habitantes), representando um aumento significativo de 34% relativamente ao ano de 2007 (p < 0,001). As intervenc¸ões coronárias percutâneas (ICP) cresceram 64% desde 2004, atingindo um total de 13 897 procedimentos e uma taxa de 1333 por milhão de habitantes no ano de 2013 (p < 0,001). A angioplastia primária (ICP-P) cresceu 265% (1328 versus 3524) atingindo uma taxa de 338/milhão, o que representou 25% do total de angioplastias efectuadas em 2013. Os stents foram o dispositivo intracoronário mais utilizado, com uma taxa de stents eluidores de fármaco de 73% em 2013. O acesso radial passou de 4,1% em 2004 para 57,9% em 2013 (p < 0,001). Conclusões: A cardiologia de intervenc¸ão mantém uma tendência de crescimento desde 2004 a 2013. Neste ano, a totalidade dos centros de cardiologia de intervenc¸ão portugueses estavam a exportar os dados para o RNCI, destacando-se o aumento relativo da angioplastia primária e o incremento do acesso radial.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Tipicamente as redes elétricas de distribuição apresentam uma topologia parcialmente malhada e são exploradas radialmente. A topologia radial é obtida através da abertura das malhas nos locais que otimizam o ponto de operação da rede, através da instalação de aparelhos de corte que operam normalmente abertos. Para além de manterem a topologia radial, estes equipamentos possibilitam também a transferência de cargas entre saídas, aquando da ocorrência de defeitos. As saídas radiais são ainda dotadas de aparelhos de corte que operam normalmente fechados, estes têm como objetivo maximizar a fiabilidade e isolar defeitos, minimizando a área afetada pelos mesmos. Assim, na presente dissertação são desenvolvidos dois algoritmos determinísticos para a localização ótima de aparelhos de corte normalmente abertos e fechados, minimizando a potência ativa de perdas e o custo da energia não distribuída. O algoritmo de localização de aparelhos de corte normalmente abertos visa encontrar a topologia radial ótima que minimiza a potência ativa de perdas. O método é desenvolvido em ambiente Matlab – Tomlab, e é formulado como um problema de programação quadrática inteira mista. A topologia radial ótima é garantida através do cálculo de um trânsito de potências ótimo baseado no modelo DC. A função objetivo é dada pelas perdas por efeito de Joule. Por outro lado o problema é restringido pela primeira lei de Kirchhoff, limites de geração das subestações, limites térmicos dos condutores, trânsito de potência unidirecional e pela condição de radialidade. Os aparelhos de corte normalmente fechados são localizados ao longo das saídas radiais obtidas pelo anterior algoritmo, e permite minimizar o custo da energia não distribuída. No limite é possível localizar um aparelho de corte normalmente fechado em todas as linhas de uma rede de distribuição, sendo esta a solução que minimiza a energia não distribuída. No entanto, tendo em conta que a cada aparelho de corte está associado um investimento, é fundamental encontrar um equilíbrio entre a melhoria de fiabilidade e o investimento. Desta forma, o algoritmo desenvolvido avalia os benefícios obtidos com a instalação de aparelhos de corte normalmente fechados, e retorna o número e a localização dos mesmo que minimiza o custo da energia não distribuída. Os métodos apresentados são testados em duas redes de distribuição reais, exploradas com um nível de tensão de 15 kV e 30 kV, respetivamente. A primeira rede é localizada no distrito do Porto e é caraterizada por uma topologia mista e urbana. A segunda rede é localizada no distrito de Bragança e é caracterizada por uma topologia maioritariamente aérea e rural.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Civil (Perfil de Estruturas e Geotecnia)
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Mecânica
Resumo:
PURPOSE: (i) To investigate whether pulsatility index (PI) and mean flow velocities (MFV) are altered in glaucoma patients. (ii) To evaluate the significance of PI in retrobulbar autoregulation capacity. METHODS: Patients with primary open-angle glaucoma (POAG; n = 49), normal tension glaucoma (NTG; n = 62) and healthy controls (n = 48) underwent colour Doppler imaging measurements of the retrobulbar vasculature. Kruskal-Wallis test was used to compare variables between the three diagnostic groups. Restricted cubic splines were used to determine nonlinearities between the resistive index (RI) and PI correlations. RESULTS: Mean flow velocities (MFV) were lower in both short posterior ciliary arteries (SCPA) and central retinal arteries (CRA) from the two glaucoma groups (p < 0.04 versus healthy controls). No differences were detected in RI or PI in any arteries of the three diagnostic groups (p > 0.08). In healthy individuals, correlations between RI and PI were linear in all arteries. In both POAG and NTG patients, CRA presented a nonlinear curve with a cutpoint at RI 0.77 (p < 0.001) and 0.61 (p = 0.03), respectively, above which the slope increased nearly five- and tenfold (POAG: 1.96 to 10.06; NTG: -0.46-4.06), respectively. A nonlinear correlation in the ophthalmic artery was only observed in NTG patients, with a cutpoint at RI 0.82 (p < 0.001), above which the slope increased from 3.47 to 14.03. CONCLUSIONS: Glaucoma patients do not present the linear relationships between RI and PI observed in healthy individuals. Their nonlinear relations may be indicative of an altered autoregulation and suggest a possible threshold RI could be determined above which autoregulatory disturbances become more relevant.
Resumo:
PURPOSE: Recently, the absence of spontaneous venous pulsation (SVP) has been suggested as a vascular risk factor for primary open-angle glaucoma (POAG). As the mechanism behind this phenomenon is still unknown, the authors have studied this vascular component using colour Doppler imaging (CDI). METHODS: A total of 236 patients were divided into three diagnostic groups: healthy controls (81), POAG (86) and normal tension glaucoma (NTG; 69). All subjects were submitted to CDI studies of the retrobulbar circulation, intraocular pressure measurements and assessment of SVP existence. Mann-Whitney, chi-square contingency tables and Spearman correlations were used to explore differences and correlations between variables in the diagnostic groups. RESULTS: Eighty-two percent of healthy controls had SVP (66/81), while a smaller numbers were registered in both glaucoma groups: POAG - 50% (43/86); NTG - 51% (35/69). In NTG patients, but not in POAG patients, the prevalence of the SVP phenomenon decreases with increased glaucoma damage (p = 0.04; p = 0.55, respectively). Overall glaucoma patients from both groups had lower central retinal vein (CRV) velocities than the healthy controls (p < 0.05). NTG patients with SVP had less severe visual field defects (mean defect -6.92 versus -11.1, p < 0.05), higher [correction added after online publication 21 September 2012; the word 'higher' has been inserted to replace the word 'lower'] peak systolic and mean flow velocities in the central retinal artery (p < 0.01; p < 0.05, respectively) as well as higher [correction added after online publication 21 September 2012; the word higher has been inserted to replace the word lower] maximal velocities and RI of the CRV (p < 0.02; p < 0.05, respectively). CONCLUSIONS: Glaucoma patients have a decrease in CRV velocities. SVP is less prevalent in glaucoma patients than in healthy individuals. This phenomenon apparently reflects different hemodynamic patterns in the central retinal vessels. This variable may be of particular importance in NTG patients, where it may be associated with more advanced functional damage.
Resumo:
PURPOSE: To determine the correlation between ocular blood flow velocities and ocular pulse amplitude (OPA) in glaucoma patients using colour Doppler imaging (CDI) waveform analysis. METHOD: A prospective, observer-masked, case-control study was performed. OPA and blood flow variables from central retinal artery and vein (CRA, CRV), nasal and temporal short posterior ciliary arteries (NPCA, TPCA) and ophthalmic artery (OA) were obtained through dynamic contour tonometry and CDI, respectively. Univariate and multiple regression analyses were performed to explore the correlations between OPA and retrobulbar CDI waveform and systemic cardiovascular parameters (blood pressure, blood pressure amplitude, mean ocular perfusion pressure and peripheral pulse). RESULTS: One hundred and ninety-two patients were included [healthy controls: 55; primary open-angle glaucoma (POAG): 74; normal-tension glaucoma (NTG): 63]. OPA was statistically different between groups (Healthy: 3.17 ± 1.2 mmHg; NTG: 2.58 ± 1.2 mmHg; POAG: 2.60 ± 1.1 mmHg; p < 0.01), but not between the glaucoma groups (p = 0.60). Multiple regression models to explain OPA variance were made for each cohort (healthy: p < 0.001, r = 0.605; NTG: p = 0.003, r = 0.372; POAG: p < 0.001, r = 0.412). OPA was independently associated with retrobulbar CDI parameters in the healthy subjects and POAG patients (healthy CRV resistance index: β = 3.37, CI: 0.16-6.59; healthy NPCA mean systolic/diastolic velocity ratio: β = 1.34, CI: 0.52-2.15; POAG TPCA mean systolic velocity: β = 0.14, CI 0.05-0.23). OPA in the NTG group was associated with diastolic blood pressure and pulse rate (β = -0.04, CI: -0.06 to -0.01; β = -0.04, CI: -0.06 to -0.001, respectively). CONCLUSIONS: Vascular-related models provide a better explanation to OPA variance in healthy individuals than in glaucoma patients. The variables that influence OPA seem to be different in healthy, POAG and NTG patients.
Resumo:
Giant cell arteritis (GCA) is a systemic large vessel vasculitis, with extracranial arterial involvement described in 10-15% of cases, usually affecting the aorta and its branches. Patients with GCA are more likely to develop aortic aneurysms, but these are rarely present at the time of the diagnosis. We report the case of an 80-year-old Caucasian woman, who reported proximal muscle pain in the arms with morning stiffness of the shoulders for eight months. In the previous two months, she had developed worsening bilateral arm claudication, severe pain, cold extremities and digital necrosis. She had no palpable radial pulses and no measurable blood pressure. The patient had normochromic anemia, erythrocyte sedimentation rate of 120 mm/h, and a negative infectious and autoimmune workup. Computed tomography angiography revealed concentric wall thickening of the aorta extending to the aortic arch branches, particularly the subclavian and axillary arteries, which were severely stenotic, with areas of bilateral occlusion and an aneurysm of the ascending aorta (47 mm). Despite corticosteroid therapy there was progression to acute critical ischemia. She accordingly underwent surgical revascularization using a bilateral carotid-humeral bypass. After surgery, corticosteroid therapy was maintained and at six-month follow-up she was clinically stable with reduced inflammatory markers. GCA, usually a chronic benign vasculitis, presented exceptionally in this case as acute critical upper limb ischemia, resulting from a massive inflammatory process of the subclavian and axillary arteries, treated with salvage surgical revascularization.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente, perfil Engenharia Sanitária
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia de Materiais
Resumo:
RESUMO:RESUMO: Nos últimos anos a ultrassonografia emergiu como um instrumento importante no diagnóstico da patologia torácica. O progresso tecnológico possibilitou a conceção de novos equipamentos como a ecoendoscopia brônquica radial e linear. Verificou-se, igualmente, o aparecimento de indicações para a realização de ecografia transtorácica. Uma das principais doenças impulsionadoras da técnica ultrassonográfica no tórax foi o cancro do pulmão, primeira causa de morte oncológica a nível mundial. A aplicabilidade e conhecimento do papel dos ultrassons no âmbito do diagnóstico e estadiamento do cancro do pulmão não se encontram esgotados, persistindo focos de controvérsia e dúvida científica que se pretendem esclarecer. A presente tese foi organizada em cinco capítulos: o primeiro abordou de forma geral e introdutória o estado da arte referente à ultrassonografia torácica, cancro do pulmão e a sua conjugação; o segundo destacou os principais objetivos; o terceiro sumarizou a metodologia utilizada; o quarto englobou os cinco estudos publicados, descritos subsequentemente, e o quinto incluiu uma discussão concisa, as principais conclusões e perspetivas futuras. O primeiro estudo avaliou a rentabilidade diagnóstica, segurança e curva de aprendizagem num coorte de 179 doentes submetidos a ecoendoscopia brônquica linear. De acordo com as indicações para este procedimento os doentes foram subdivididos em três grupos: (1) diagnóstico, (2) diagnóstico e estadiamento e (3) estadiamento. Para o primeiro, segundo e terceiro grupos a sensibilidade da ecoendoscopia foi 86.1%, 86.7% e 95% respetivamente e a precisão técnica foi 87.5%, 93.1% e 97.7% respetivamente. O treino originou um aumento progressivo do número de locais puncionados por doente, com menor duração e sem complicações, comprovando a eficácia e segurança do método quando realizado na população Portuguesa por broncologistas com experiência. O segundo estudo foi conduzido para averiguar a eficácia e custo da ecoendoscopia brônquica linear realizada através da via aérea e/ou esófago no diagnóstico de lesões sugestivas de neoplasia do pulmão, após ineficácia das técnicas convencionais. Nos doentes incluídos prospetivamente alcançou-se um diagnóstico definitivo em 106 casos (87.6%). A sensibilidade global para o diagnóstico de cancro do pulmão foi 89.8%, a especificidade foi 100%, o valor preditivo positivo foi 100%, o valor preditivo negativo foi 20% e a precisão foi 90.1%. Esta estratégia ultrassonográfica abrangente evitou intervenções cirúrgicas diagnósticas em doentes anteriormente submetidos a broncoscopia flexível ou punção aspirativa transtorácica guiada por tomografia computorizada, proporcionando uma redução significativa dos custos. No terceiro estudo investigou-se a viabilidade e papel da conjugação da ecoendoscopia brônquica linear com técnicas moleculares na avaliação de antigénios tumorais e padrões de metastização ganglionar em doentes com cancro do pulmão de não-pequenas células (CPNPC). Os marcadores citoqueratina 19 (CK-19), antigénio carcinoembrionário (CEA), molécula de adesão celular epitelial (EPCAM), sialyl-Lewis X e CD44 foram determinados nos aspirados ganglionares de 33 doentes com neoplasia e 17 controlos 10 Ultrassonografia através de citometria de fluxo (CF) e reação em cadeia da polimerase em tempo real (RTPCR). Os doentes com CPNPC possuíam um compartimento celular epitelial significativamente aumentado e com marcação superior de CK-19 comparativamente ao grupo de controlo. O compartimento imune foi também analisado nestas amostras e revelou-se alterado no CPNPC com aumento da população de monócitos e diminuição das subpopulações linfocitárias. Os transcriptos de CK-19, CEA e EPCAM estavam elevados nos doentes com cancro do pulmão, identificando-se uma correlação positiva entre estes marcadores e o tamanho da lesão primária. Concluiu-se que a identificação de CK-19, CEA e EPCAM nas amostras obtidas por ecoendoscopia e avaliadas por CF e RTPCR foi viável, podendo auxiliar na deteção de metástases ganglionares no CPNPC. O quarto estudo envolveu a combinação da ecoendoscopia brônquica radial com uma criosonda para o diagnóstico de lesões pulmonares sólidas periféricas. Foi determinada a viabilidade, rentabilidade diagnóstica, tamanho das amostras e segurança do método. Lesões inferiores a 40mm foram localizadas por ultrassonografia sendo os doentes randomizados para a realização de biópsias transbrônquicas com pinça seguidas por criosonda ou vice-versa. Nos 39 casos incluídos a lesão foi visualizada pela minisonda em 31 doentes (79.5%), com 80.6% de prevalência de cancro do pulmão na amostra. A rentabilidade diagnóstica da pinça de biópsia foi 61.3% e da criosonda foi 74.2%. O tamanho do tecido adquirido pelas criobiópsias foi significativamente maior do que o alcançado por pinça (11.17mm2 vs. 4.69mm2, p<0.001). Ocorreu um único caso de hemorragia moderada, controlada através de medidas conservadoras. As biópsias transbrônquicas com criosonda sob orientação de ecoendoscopia radial foram seguras e eficazes na obtenção de amostras histológicas. O quinto estudo determinou o valor diagnóstico da ecografia transtorácica na identificação de malignidade em doentes com derrame pleural de natureza indeterminada. Foram examinados de forma prospetiva 154 doentes. Os resultados clínicos e radiológicos de cada caso foram ocultados ao executante do exame que gerou imagens estáticas e vídeos ultrassonográficos relevantes. Estes foram posteriormente visualizados, sendo as suas características classificadas por revisores independentes e comparadas com o diagnóstico definitivo. Em 66 casos o diagnóstico foi de derrame pleural maligno (68.2% com cancro do pulmão) e em 67 de derrame benigno. A ecografia torácica obteve 80.3% de sensibilidade, 83.6% de especificidade, 81.2% de valor preditivo negativo e 82.8% de valor preditivo positivo na deteção de malignidade. A nodularidade pleural ou diafragmática, espessamento pleural superior a 10mm e sinal de swirling foram significativamente diferentes (p<0.001) sendo sugestivos de derrame maligno. A existência de nodularidade pleural e ausência de broncograma aéreo ecográfico aumentaram a probabilidade de malignidade (OR 29.0 e OR 10.4, respetivamente). A ecografia transtorácica permitiu diferenciar derrame pleural maligno do benigno. A existência de nódulos pleurais constituiu o fator discriminador mais relevante. Em conclusão, os resultados desta tese possibilitam uma melhor compreensão do papel da ecoendoscopia brônquica (linear e radial) e ecografia transtorácica no diagnóstico e estadiamento do cancro do pulmão, com implicações e aplicabilidade na prática clínica.------------- ABSTRACT: In recent years ultrasonography has emerged as an important instrument in the diagnosis of thoracic diseases. Technological progress has enabled the design of new equipment such as radial and linear endobronchial ultrasound. In addition, indications for transthoracic echography were established. One of the main diseases responsible for the progression of chest sonography was lung cancer, the leading cause of cancer mortality worldwide. The applicability and knowledge of the role of ultrasonography in diagnosing and staging lung cancer is not depleted, persisting foci of controversy and scientific doubt that we intend to elucidate. The present thesis was organized into five chapters: the first included a general introduction regarding chest ultrasound, lung cancer and their combination; the second emphasized the main objectives; the third summarized the methodology used; the fourth encompassed the five published studies, subsequently described, and the fifth included a concise discussion, the main findings and future perspectives. The first study evaluated the diagnostic yield, safety and learning curve in a cohort of 179 patients submitted to linear endobronchial ultrasound. According to procedure indications, the patients were divided into three groups: (1) diagnosis, (2) diagnosis and staging, and (3) staging. For the first, second and third groups, endobronchial ultrasound sensitivity was 86.1%, 86.7% and 95% respectively and accuracy was 87.5%, 93.1% and 97.7% respectively. Practise led to an increase number of punctured sites per patient, in a shorter period of time and without complications, proving the safety and efficacy of the method when performed in the Portuguese population by expert echoscopists. The second study was conducted to determine the efficacy and cost of linear endobronchial ultrasound performed through the airway and/or oesophagus for diagnosis of lesions suggestive of lung cancer, after failure of conventional techniques. Of the patients prospectively enrolled a definitive diagnosis was reached in 106 cases (87.6%). The overall sensitivity for the diagnosis of lung cancer was 89.8%, specificity was 100%, positive predictive value was 100%, negative predictive value was 20% and accuracy was 90.1%. In conclusion, this global ultrasonographic strategy avoided diagnostic surgical procedures in patients that had undergone flexible bronchoscopy or computed tomography-guided transthoracic needle aspiration, providing a significant cost reduction. In the third study, the feasibility and role of linear endobronchial ultrasound combined with molecular techniques in the evaluation of tumour antigens and patterns of lymph node metastasis in patients with non-small cell lung cancer (NSCLC) was investigated. Cytokeratin 19 (CK-19), carcinoembryonic antigen (CEA), epithelial cell adhesion molecule (EPCAM), sialyl Lewis-X and CD44 were determined in lymph node aspirates of 33 lung cancer patients and 17 controls, using flow cytometry (FC) and reverse transcription polymerase chain reaction (RT-PCR). In patients with NSCLC the epithelial cell compartment was significantly increased nd showed brighter CK-19 staining, compared to the control group. In NSCLC patients the immune compartment revealed an increased monocyte population and decreased lymphocyte subsets. The transcripts of CK- 19, CEA and EPCAM were higher in lung cancer patients and a positive correlation between these markers and the size of the primary lesion was also found. We concluded that the identification of CK-19, CEA and EPCAM in endobronchial ultrasound samples, using RT-PCR and FC was feasible and might aid in the detection of NSCLC lymph node metastases. The fourth study involved the combination of the radial endobronchial ultrasound with the cryoprobe for diagnosing solid peripheral lung lesions. We determined the feasibility, diagnostic yield, sample size and safety of the method. Lesions less than 40mm were located by ultrasound and forceps or cryobiopsies were performed in a randomized order. Of the 39 cases included, the lesion could be visualized by the miniprobe in 31 patients (79.5%), and lung cancer prevalence was 80.6%. The diagnostic yield of the biopsy forceps was 61.3% and for the cryobiopsy was 74.2 %. Cryobiopsies were significantly larger than forceps biopsies (11.17mm2 vs. 4.69mm2, p<0.001). There was only one case of moderate bleeding that was controlled by conservative measures. Transbronchial cryobiopsies under radial endobronchial ultrasound guidance were safe and effective in obtaining histological samples. The fifth study determined the diagnostic value of transthoracic sonography in predicting malignancy in patients with an undiagnosed pleural effusion. One hundred and fifty four patients were prospectively scanned. Relevant ultrasound images and videos were generated by an operator blinded to clinical and radiological results. These were subsequently visualized, its characteristics classified by independent reviewers and compared to the final diagnosis. A malignant pleural effusion was diagnosed in 66 cases (68.2 % with lung cancer) and a benign effusion in 67 cases. Thoracic ultrasound had a sensitivity of 80.3 %, specificity of 83.6%, negative predictive value of 81.2 % and positive predictive value of 82.8% to detect malignancy. The presence of pleural or diaphragmatic nodularity, pleural thickening greater than 10mm and swirling signal were significantly different (p<0.001 ), being suggestive of malignant effusion. The existence of pleural nodularity and absence of lung air bronchogram were more likely to indicate malignancy (OR 29.0 and OR 10.4, respectively). Transthoracic ultrasonography permits the distinction between malignant and benign pleural effusions. Pleural nodules were the most relevant feature. In conclusion, the results of this thesis provide a better understanding of the role of endobronchial ultrasound (linear and radial) and transthoracic sonography in lung cancer diagnosis and staging, with direct implications and applicability in clinical practice.