1000 resultados para R-0


Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present three natural language marking strategies based on fast and reliable shallow parsing techniques, and on widely available lexical resources: lexical substitution, adjective conjunction swaps, and relativiser switching. We test these techniques on a random sample of the British National Corpus. Individual candidate marks are checked for goodness of structural and semantic fit, using both lexical resources, and the web as a corpus. A representative sample of marks is given to 25 human judges to evaluate for acceptability and preservation of meaning. This establishes a correlation between corpus based felicity measures and perceived quality, and makes qualified predictions. Grammatical acceptability correlates with our automatic measure strongly (Pearson's r = 0.795, p = 0.001), allowing us to account for about two thirds of variability in human judgements. A moderate but statistically insignificant (Pearson's r = 0.422, p = 0.356) correlation is found with judgements of meaning preservation, indicating that the contextual window of five content words used for our automatic measure may need to be extended. © 2007 SPIE-IS&T.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The joint fluids of 37 patients with rheumatoid arthritis, eight patients with traumatic injuries to their joints, two patients with Reiter's syndrome and three patients with psoriatic arthritis were tested for the presence of B cell colony stimulating activity (B cell CSA). B cell CSA was found in all of the joint fluids from the patients with rheumatoid arthritis but in none of the joint fluids from patients with traumatic injuries to their joints or in the joint fluids from the patients with Reiter's syndrome. A trace of B cell CSA was found in the joint fluid of one of the three patients with psoriatic arthritis. There was a positive correlation (r = 0.796) between the amount of rheumatoid factor present in the joint fluids and the titre of B cell CSA. This correlation was highly significant (P less than 0.001). The B cell CSA was localized to component(s) with molecular weight ranges 115-129 kD and 64-72 kD and an isoelectric point of 6.8. Its activity was sensitive to reduction with 2-mercaptoethanol and to the oxidising action of potassium periodate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We describe a simple one-step technique for the growth of human B cell colonies in semi-solid agar in vitro. This method used conditioned medium from the human plasmacytoma cell line LICR-LON-H My 2 as a source of stimulating activity. A linear relationship exists between the number of B cells seeded and the number of colonies formed (r = 0.95). Most colony forming cells, approximately 1 in 500 of B cells seeded, lack surface immunoglobulin, possess Fc receptors and mark with the Leu 12 monoclonal antibody. Cells within developing colonies are found to have cytoplasmic IgM, IgA and IgG depending on the length of time in culture.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The mouse spleen cell assay (MSCA) has been compared with a radioimmunoassay for the measurement of serum erythropoietin (Ep). In 20 normal subjects the serum values ranged from 15 to 73 mU/ml for the MSCA compared with 5-30 mU/ml for the RIA. For normal sera there was no correlation between the results of the two assays. In 37 patients with anaemias of differing aetiologies and at various stages of treatment values ranged from 10 to 3645 mU/ml for the MSCA and 13-10,000 mU/ml for the RIA. Although patient values from the two assays were highly correlated (r = 0.98, P less than 0.001), the MSCA results were generally lower. These discrepancies can be largely accounted for by two factors. Firstly the MSCA is sensitive to non-specific matrix effects. Secondly, heat inactivation of serum, a prerequisite for the MSCA, but not for the RIA, destroys a variable and unpredictable proportion of the Ep in the test sera leading to an underestimation of Ep in the MSCA. We conclude that the RIA is more reliable than the MSCA which, in its present form, cannot be recommended for the accurate measurement of serum erythropoietin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cognitive assessment typically involves assessing a person’s cognitive performance in unfamiliar and ar-guably unnatural clinical surroundings. User-centred approaches to assessment and monitoring, driven by issues such as enjoyability and familiarity, are largely absent. Everyday technologies, for example, smartphones represent an opportunity to obtain an objective assessment of a person’s cognitive capabili-ties in a non-threatening, discreet and familiar way, e.g. by everyday puzzle games undertaken as a leisure activity at home. We examined the strength of relationships that exist between performance on common puzzle games and standard measures of neuropsychological performance. Twenty-nine participants, aged 50 - 65 years, completed a comprehensive neuropsychological test battery and played three smart-phone-based puzzle games in triplicate: a picture puzzle [Matches Plus], a word puzzle [Jumbline] and a number puzzle [Sudoku]. As anticipated, a priori, significant correlations were observed between scores on a picture puzzle and visual memory test (r = 0.49; p = 0.007); a word puzzle and estimated verbal IQ (r = 0.53; p = 0.003) and verbal learning (r = 0.30; p = 0.039) tests; and a number puzzle and reason-ing/problem solving test (r = 0.42; p = 0.023). Further analyses making allowance for multiple compari-sons identified a significant unanticipated correlation (r = 0.49; p = 0.007) between number puzzle scores and a measure of nonverbal working memory. Performance on these smartphone-based games was in-dicative of relative cognitive ability across several cognitive domains at a fixed time point. Smart-phone-based, everyday puzzle games may offer a valid, portable measure of assessing and monitoring cognition in older adults.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RATIONALE: In bronchiectasis there is a need for improved markers of lung function to determine disease severity and response to therapy.

OBJECTIVES: To assess whether the lung clearance index is a repeatable and more sensitive indicator of computed tomography (CT) scan abnormalities than spirometry in bronchiectasis.

METHODS: Thirty patients with stable bronchiectasis were recruited and lung clearance index, spirometry, and health-related quality of life measures were assessed on two occasions, 2 weeks apart when stable (study 1). A separate group of 60 patients with stable bronchiectasis was studied on a single visit with the same measurements and a CT scan (study 2).

MEASUREMENTS AND MAIN RESULTS: In study 1, the intervisit intraclass correlation coefficient for the lung clearance index was 0.94 (95% confidence interval, 0.89 to 0.97; P < 0.001). In study 2, the mean age was 62 (10) years, FEV1 76.5% predicted (18.9), lung clearance index 9.1 (2.0), and total CT score 14.1 (10.2)%. The lung clearance index was abnormal in 53 of 60 patients (88%) and FEV1 was abnormal in 37 of 60 patients (62%). FEV1 negatively correlated with the lung clearance index (r = -0.51, P < 0.0001). Across CT scores, there was a relationship with the lung clearance index, with little evidence of an effect of FEV1. There were no significant associations between the lung clearance index or FEV1 and health-related quality of life.

CONCLUSIONS: The lung clearance index is repeatable and a more sensitive measure than FEV1 in the detection of abnormalities demonstrated on CT scan. The lung clearance index has the potential to be a useful clinical and research tool in patients with bronchiectasis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction
PET-computed tomography (PET-CT) is a useful staging imaging modality in colorectal liver metastases (CRLM). This study aimed to determine whether PET-CT parameters, standardized uptake value (SUV) and reconstructed tumour volume (RTV), are predictors of prognosis and survival.

Methods
A study of all resectable CRLM patients in the regional HPB unit from 2007–2009 was performed. Preoperative PET-CT scans were retrospectively reviewed; SUV, diameter and RTV for each lesion was recorded. Correlation analysis was performed with other pathological and biochemical parameters, by Pearson’s correlation analysis. Survival analysis was performed using Cox regression hazard model. A P value of less than 0.05 was considered statistically significant.

Results
A total of 79 patients were included. SUV moderately correlated with tumour diameter, both PET-CT (r=0.4927; P<0.0001) and histology (r=0.4513; P=0.0003); RTV (r=0.4489; P<0.001), preoperative carcinoembryonic antigen (CEA) (r=0.4977; P=0.0001), and postoperative CEA (r=0.3727; P=0.004). Multivariate analysis found that an independent predictor of SUVmax was preoperative CEA (P=0.03). RTV strongly correlated with preoperative CEA (r=0.9389; P<0.0001). SUV and RTV had a negative effect on survival.

Conclusion
PET-CT, in the setting of CRLM, may have a prognostic role in assessing survival. Although no definite conclusions can be drawn regarding the prognostic role of SUV and RTV, it acts to reinforce the need for further prospective studies to validate these findings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Assessment of marine downscaling of global model simulations to the regional scale is a prerequisite for understanding ocean feedback to the atmosphere in regional climate downscaling. Major difficulties arise from the coarse grid resolution of global models, which cannot provide sufficiently accurate boundary values for the regional model. In this study, we first setup a stretched global model (MPIOM) to focus on the North Sea by shifting poles. Second, a regional model (HAMSOM) was performed with higher resolution, while the open boundary values were provided by the stretched global model. In general, the sea surface temperatures (SSTs) in the two experiments are similar. Major SST differences are found in coastal regions (root mean square difference of SST is reaching up to 2°C). The higher sea surface salinity in coastal regions in the global model indicates the general limitation of this global model and its configuration (surface layer thickness is 16 m). By comparison, the advantage of the absence of open lateral boundaries in the global model can be demonstrated, in particular for the transition region between the North Sea and Baltic Sea. On long timescales, the North Atlantic Current (NAC) inflow through the northern boundary correlates well between both model simulations (R~0.9). After downscaling with HAMSOM, the NAC inflow through the northern boundary decreases by ~10%, but the circulation in the Skagerrak is stronger in HAMSOM. The circulation patterns of both models are similar in the northern North Sea. The comparison suggests that the stretched global model system is a suitable tool for long-term free climate model simulations, and the only limitations occur in coastal regions. Regarding the regional studies focusing on the coastal zone, nested regional model can be a helpful alternative.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Structural and functional change in the microcirculation in type 1 diabetes mellitus predicts future end-organ damage and macrovascular events. We explored the utility of novel signal processing techniques to detect and track change in ocular hemodynamics in patients with this disease. 24 patients with uncomplicated type 1 diabetes mellitus, and 18 age-and-sex matched control subjects were studied. Doppler ultrasound was used to interrogate the carotid and ophthalmic arteries and digital photography to image the retinal vasculature. Frequency analysis algorithms were applied to quantify velocity waveform structure and retinal photographic data at baseline and following inhalation of 100% oxygen. Frequency data was compared between groups. No significant differences were found in the resistive index between groups at baseline or following inhaled oxygen. Frequency analysis of the Doppler flow velocity waveforms identified significant differences in bands 3-7 between patients and controls in data captured from the ophthalmic artery (p<0.01 for each band). In response to inhaled oxygen, changes in the frequency band amplitudes were significantly greater in control subjects compared with patients (p<0.05). Only control subjects demonstrated a positive correlation (R=0.61) between change in retinal vessel diameter and frequency band amplitudes derived from ophthalmic artery waveform data. The use of multimodal signal processing techniques applied to Doppler flow velocity waveforms and retinal photographic data identified preclinical change in the ocular microcirculation in patients with uncomplicated diabetes mellitus. An impaired autoregulatory response of the retinal microvasculature may contribute to the future development of retinopathy in such patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The association between aflatoxin intake from maize-based weaning food and aflatoxin albumin adducts (AF-alb) was investigated in 148 Tanzanian children aged between 12 and 22 months, at 2 visits 6 months apart. At the first visit (storage season) there was a significant correlation at the individual level between AF-alb (geometric mean 43.2 pg/mg albumin) and aflatoxin intake (geometric mean 81.7 ng/kg b.w./d) through maize-based weaning food (r = 0.51, p < 0.01). Overall, this correlation was r = 0.43 (p < 0.01). The AF-alb level in weaning-age children in Tanzania closely reflects aflatoxin intake from maize in weaning food. Exposure levels suggest children may be at risk from aflatoxin associated health effects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Alzheimer’s disease (AD) is associated with significant disturbances in the homeostasis of Na+ and K+ ions as well as reduced levels of Na+/K+ ATPase in the brain. This study used ICP-MS to accurately quantify Na+ and K+ concentrations in human postmortem brain tissue. We analyzed parietal cortex (Brodmann area 7) from 28 cognitively normal age-matched controls, 15 cases of moderate AD, 30 severe AD, and 15 dementia with Lewy bodies (DLB). Associations were investigated between [Na+] and [K+] and a number of variables including diagnosis, age, gender, Braak tangle stage, amyloid-β (Aβ) plaque load, tau load, frontal tissue pH, and APOE genotype. Brains from patients with severe AD had significantly higher (26%; p<0.001) [Na+] (mean 65.43 ± standard error 2.91 mmol/kg) than controls, but the concentration was not significantly altered in moderate AD or DLB. [Na+] correlated positively with Braak stage (r=0.45; p<0.0001), indicating association with disease severity. [K+] in tissue was 10% lower (p<0.05) in moderate AD than controls. However, [K+] in severe AD and DLB (40.97±1.31 mmol/kg) was not significantly different from controls. There was a significant positive correlation between [K+] and Aβ plaque load (r=0.46; p=0.035), and frontal tissue pH (r=0.35; p=0.008). [Na+] was not associated with [K+] across the groups, and neither ion was associated with tau load or APOE genotype. We have demonstrated disturbances of both [Na+] and [K+] in relation to the severity of AD and markers of AD pathology, although it is possible that these relate to late-stage secondary manifestations of the disease pathology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The motivation for this study was to reduce physics workload relating to patient- specific quality assurance (QA). VMAT plan delivery accuracy was determined from analysis of pre- and on-treatment trajectory log files and phantom-based ionization chamber array measurements. The correlation in this combination of measurements for patient-specific QA was investigated. The relationship between delivery errors and plan complexity was investigated as a potential method to further reduce patient-specific QA workload. Thirty VMAT plans from three treatment sites - prostate only, prostate and pelvic node (PPN), and head and neck (H&amp;N) - were retrospectively analyzed in this work. The 2D fluence delivery reconstructed from pretreatment and on-treatment trajectory log files was compared with the planned fluence using gamma analysis. Pretreatment dose delivery verification was also car- ried out using gamma analysis of ionization chamber array measurements compared with calculated doses. Pearson correlations were used to explore any relationship between trajectory log file (pretreatment and on-treatment) and ionization chamber array gamma results (pretreatment). Plan complexity was assessed using the MU/ arc and the modulation complexity score (MCS), with Pearson correlations used to examine any relationships between complexity metrics and plan delivery accu- racy. Trajectory log files were also used to further explore the accuracy of MLC and gantry positions. Pretreatment 1%/1 mm gamma passing rates for trajectory log file analysis were 99.1% (98.7%-99.2%), 99.3% (99.1%-99.5%), and 98.4% (97.3%-98.8%) (median (IQR)) for prostate, PPN, and H&amp;N, respectively, and were significantly correlated to on-treatment trajectory log file gamma results (R = 0.989, p &lt; 0.001). Pretreatment ionization chamber array (2%/2 mm) gamma results were also significantly correlated with on-treatment trajectory log file gamma results (R = 0.623, p &lt; 0.001). Furthermore, all gamma results displayed a significant correlation with MCS (R &gt; 0.57, p &lt; 0.001), but not with MU/arc. Average MLC position and gantry angle errors were 0.001 ± 0.002 mm and 0.025° ± 0.008° over all treatment sites and were not found to affect delivery accuracy. However, vari- ability in MLC speed was found to be directly related to MLC position accuracy. The accuracy of VMAT plan delivery assessed using pretreatment trajectory log file fluence delivery and ionization chamber array measurements were strongly correlated with on-treatment trajectory log file fluence delivery. The strong corre- lation between trajectory log file and phantom-based gamma results demonstrates potential to reduce our current patient-specific QA. Additionally, insight into MLC and gantry position accuracy through trajectory log file analysis and the strong cor- relation between gamma analysis results and the MCS could also provide further methodologies to both optimize the VMAT planning and QA process. 

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background

Feasible, cost-effective instruments are required for the surveillance of moderate-to-vigorous physical activity (MVPA) and sedentary behaviour (SB) and to assess the effects of interventions. However, the evidence base for the validity and reliability of the World Health Organisation-endorsed Global Physical Activity Questionnaire (GPAQ) is limited. We aimed to assess the validity of the GPAQ, compared to accelerometer data in measuring and assessing change in MVPA and SB.


Methods

Participants (n = 101) were selected randomly from an on-going research study, stratified by level of physical activity (low, moderate or highly active, based on the GPAQ) and sex. Participants wore an accelerometer (Actigraph GT3X) for seven days and completed a GPAQ on Day 7. This protocol was repeated for a random sub-sample at a second time point, 3–6 months later. Analysis involved Wilcoxon-signed rank tests for differences in measures, Bland-Altman analysis for the agreement between measures for median MVPA and SB mins/day, and Spearman’s rho coefficient for criterion validity and extent of change.

Results

95 participants completed baseline measurements (44 females, 51 males; mean age 44 years, (SD 14); measurements of change were calculated for 41 (21 females, 20 males; mean age 46 years, (SD 14). There was moderate agreement between GPAQ and accelerometer for MVPA mins/day (r = 0.48) and poor agreement for SB (r = 0.19). The absolute mean difference (self-report minus accelerometer) for MVPA was −0.8 mins/day and 348.7 mins/day for SB; and negative bias was found to exist, with those people who were more physically active over-reporting their level of MVPA: those who were more sedentary were less likely to under-report their level of SB. Results for agreement in change over time showed moderate correlation (r = 0.52, p = 0.12) for MVPA and poor correlation for SB (r = −0.024, p = 0.916).


Conclusions

Levels of agreement with objective measurements indicate the GPAQ is a valid measure of MVPA and change in MVPA but is a less valid measure of current levels and change in SB. Thus, GPAQ appears to be an appropriate measure for assessing the effectiveness of interventions to promote MVPA.



Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To determine differences in overall tumor responses measured by volumetric assessment and bioluminescence imaging (BLI) following exposure to uniform and non-uniform radiation fields in an ectopic prostate tumor model.

Materials and methods: Bioluminescent human prostate tumor xenografts were established by subcutaneous implantation into male mice. Tumors were irradiated with uniform or non-uniform field configurations using conventional in vivo irradiation procedures performed using a 225 kVp generator with custom lead shielding. Tumor responses were measured using Vernier calipers and by BLI using an in vivo imaging system. Survival was defined as the time to quadroupling of pre-treatment tumor volume. 

Results: The correlation between BLI and tumor volume measurements was found to be different for un-irradiated (R = 0.61), uniformly irradiated (R = 0.34) and partially irradiated (R = 0.30) tumors. Uniformly irradiated tumors resulted in an average tumor growth delay of 60 days with median survival of 75 days, compared to partially irradiated tumors which showed an average growth delay of 24 days and median survival of 38 days. 

Conclusions: Correlation between BLI and tumor volume measurements is lower for partially irradiated tumors than those exposed to uniform dose distributions. The response of partially irradiated tumors suggests non-uniformity in response beyond physical dose distribution within the target volume. Dosimetric uncertainty associated with conventional in vivo irradiation procedures prohibits their ability to accurately determine tumor response to non-uniform radiation fields and stresses the need for image guided small animal radiation research platforms.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The new generation of activity monitors allow users to upload their data to the internet and review progress. The aim of this study is to validate the Fitbit Zip as a measure of free-living physical activity.

FINDINGS: Participants wore a Fitbit Zip, ActiGraph GT3X accelerometer and a Yamax CW700 pedometer for seven days. Participants were asked their opinion on the utility of the Fitbit Zip. Validity was assessed by comparing the output using Spearman's rank correlation coefficients, Wilcoxon signed rank tests and Bland-Altman plots. 59.5% (25/47) of the cohort were female. There was a high correlation in steps/day between the Fitbit Zip and the two reference devices (r = 0.91, p < 0.001). No statistically significant difference between the Fitbit and Yamax steps/day was observed (Median (IQR) 7477 (3597) vs 6774 (3851); p = 0.11). The Fitbit measured significantly more steps/day than the Actigraph (7477 (3597) vs 6774 (3851); p < 0.001). Bland-Altman plots revealed no systematic differences between the devices.

CONCLUSIONS: Given the high level of correlation and no apparent systematic biases in the Bland Altman plots, the use of Fitbit Zip as a measure of physical activity. However the Fitbit Zip recorded a significantly higher number of steps per day than the Actigraph.