859 resultados para Point-of-Care Systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a mathematical model to analyze the impact of the installation and operation of dispersed generation units in power distribution systems is proposed. The main focus is to determine the trade-off between the reliability and operational costs of distribution networks when the operation of isolated areas is allowed. In order to increase the system operator revenue, an optimal power flow makes use of the different energy prices offered by the dispersed generation connected to the grid. Simultaneously, the type and location of the protective devices initially installed on the protection system are reconfigured in order to minimize the interruption and expenditure of adjusting the protection system to conditions imposed by the operation of dispersed units. The interruption cost regards the unsupplied energy to customers in secure systems but affected by the normal tripping of protective devices. Therefore, the tripping of fuses, reclosers, and overcurrent relays aims to protect the system against both temporary and permanent fault types. Additionally, in order to reduce the average duration of the system interruption experienced by customers, the isolated operation of dispersed generation is allowed by installing directional overcurrent relays with synchronized reclose capabilities. A 135-bus real distribution system is used in order to show the advantages of using the mathematical model proposed. © 1969-2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this article we discuss some qualitative and geometric aspects of non-smooth dynamical systems theory. Our goal is to study the diagram bifurcation of typical singularities that occur generically in one parameter families of certain piecewise smooth vector fields named Refracted Systems. Such systems has a codimension-one submanifold as its discontinuity set. © 2012 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the cytotoxicity of experimental adhesive systems (EASs) on odontoblast-like cells. Paper discs (n=132) were impregnated with 10 μL of each EAS-R1, R2, R3, R4, and R5 (in an ascending order of hydrophilicity), followed by photoactivation. R1 and R2 are nonsolvated hydrophobic blends, R3 represents a simplified etch-and-rinse adhesive system, and R4 and R5 represent simplified self-etch adhesive systems. Discs were immersed in Dulbecco's modified Eagle's medium for 24 h to obtain eluates applied on MDPC-23 cell cultures. No material was applied on discs used as control (R0). Cell viability [3-(4,5-dimethythiazol-2-yl)-2,5-diphenyl tetrazolium bromide assay], total protein (TP) production, alkaline phosphatase (ALP) activity, type of cell death, and degree of monomer conversion Fourier transform infrared (%DC-FTIR) were evaluated. Data were analyzed by Kruskal-Wallis and Mann-Whitney tests (α=0.05). Considering R0 (control) as having 100% of cell viability, R1, R2, R3, R4, and R5 reduced the metabolic activity of cells by 36.4, 3.1, 0.2, 21.5, and 65.7%, respectively, but only R1 and R5 differed from R0. Comparing with R0, lower TP production was observed for R1, R4, and R5, while ALP activity decreased for R1 and R5. Necrotic cell death was predominant for all EASs, but only R1, R4, and R5 differed from R0. Only R5 presented a different apoptotic cell death ratio from R0. R1 presented the lowest %DC (ca. 37%), whereas R4 and R5 presented the highest (ca. 56%). In conclusion, R2 and R3 were not toxic to the MDPC-23 cells, suggesting that the degree of hydrophilicity or %DC of the EASs alone were not responsible for their cytopathic effects. © 2013 Wiley Periodicals, Inc.