981 resultados para Percutaneous coronary
Effects of long-term estrogen replacement therapy in postmenopausal women with coronary risk factors
Resumo:
Objective: Hormone replacement therapy (HRT) with estrogen alone or in concert with progesterone may exert beneficial effects on coronary endothelium-dependent vasomotion in postmenopausal women without traditional coronary risk factors. We aimed to evaluate the effect of HRT on coronary vasomotor function in postmenopausal women with traditional coronary risk factors such as hypertension, hypercholesterolemia and smoking as compared to those without HRT. Methods: Combining N-13 ammonia with PET, myocardial blood flow (MBF) was measured in ml/g/min at rest, during cold pressor test (CPT, reflecting predominantly endothelium-dependent vasomotion)and during pharmacologic vasodilation (representing predominantly endothelium-independent vasomotion) in 48 postmenopausal women with various coronary risk factors during a mean follow up (FU) of 20_9 months. postmenopausal women wer grouped according to HRT: group 1 with HRT (n_18), group 2 without HRT (n_18) and group 3 with HRT at baseline but not at FU (n_12). Results: during FU, HRT did not significantly affect lipid profile and plasma glucose levels. At baseline resting MBF was similar between groups (Table).After the FU, in group 2 and 3 the endothelium-related increase in MBF from rest to CPT (_ MBF) was significantly less than at baseline (*p_0.05) (Table). Conversely, in group 1 _MBF to CPT at FU was not significantly different from the baseline study. The group comparison of CPT-induced _MBF in group 2 and group 3 after the FU period was significantly different from group 1 (p_0.006 by ANOVA). Finally, in all three groups, hyperemic MBFs during pharmacologic vasodilation did not differ significantly between baseline and FU (Table). Conclusion: In postmenopausal women with coronary risk factors, HRT may counterbalance the adverse effects of traditional coronary risk factors on endothelium-dependent coronary vasomotion. Consequently, in addition to standard management of coronary risk factors, HRT may exert beneficial effects on the coronary endothelium that may delay the progression of coronary artery disease in postmenopausal women.
Resumo:
Papillary fibroelastomas (PFE) are benign endocardial masses and generally originate from the cardiac valves, while PFE arising from the ascending thoracic aorta are an uncommon clinical finding. We report the case of a 78-year-old female who presented to the emergency department with an acute ST segment elevation myocardial infarction. Urgent coronary angiography showed no significant coronary artery obstructive disease but left ventriculography revealed the presence of a highly mobile mass located in the proximal portion of the ascending thoracic aorta. We postulated that the clinical symptoms were caused by embolization from the aortic mass and surgical excision of the peduncle was performed. Histopathological examination revealed a PFE with thrombotic material. Nowadays, surgical excision of PFE remains, the treatment of choice for symptomatic patients with excellent short- and long-term results but recurrence of PFE following surgical excision has not been reported.
Resumo:
Non-invasive visualization of the coronary arteries represents a major challenge in modern cardiology, but this goal may be achieved in the near future by MR angiography. Possible applications are non-invasive diagnosis of coronary artery disease, and follow-up examinations for therapy control after PTCA, in order to detect restenosis at an early stage. A multiple slice technique (2 mm slice thickness, with a spatial resolution of 1 x 1 mm, Philips Gyroscan ACS-II, 1.5 Tesla) was used. Ten volunteers were imaged and 10 patients with coronary artery disease were examined before and after PTCA. MR measurements were validated by quantitative coronary angiography. The diameters of the proximal coronary arteries as measured by both methods were compared, and a good correlation was found (r = 0.76). Thus, it is concluded that non-invasive visualization of the coronary arteries is possible before and after PTCA and allows to determine potential restenoses. However, patient cooperation is essential for good image quality. Moreover, limited spatial image resolution and breathing artifacts restrict MR coronary angiography today to be used as a routine diagnostic tool for the diagnosis of coronary artery disease.
Resumo:
Three-dimensional free-breathing coronary magnetic resonance angiography was performed in eight healthy volunteers with use of real-time navigator technology. Images acquired with the navigator localized at the right hemidiaphragm and at the left ventricle were objectively compared. The diaphragmatic navigator was found to be superior for vessel delineation of middle to distal portions of the coronary arteries.
Resumo:
Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.
Resumo:
Trends in age-specific and age-standardized death certification rates from all ischaemic heart disease and cerebrovascular disease in Switzerland have been analysed for the period 1969-87, i.e. since the introduction of the Eighth Revision of the International Classification of Diseases for coding causes of death. For coronary heart disease, overall age-standardized rates of males in the mid-late 1980's were similar to those in the late 1960's, although some upward trend was evident up to the mid 1970's (with a peak rate of 120.4/100,000, World standard, in 1978) followed by steady declines in more recent years (103.8/100,000 in 1987). These falls were larger in truncated (35 to 64 years) rates. For females, overall age-standardized rates were stable around a value of 40/100,000, while truncated rates tended to decrease, particularly over most recent years, with an overall decline of over 25%. Examination of age-specific trends showed that in both sexes declines at younger ages were already evident in the earlier calendar period, while above age 50 some fall became evident only in most recent years. Thus, in a formal log-linear age/period/cohort model, both a period and a cohort component emerged. In relation to cerebrovascular diseases, the overall declines were around 40% in males (from 67.4 to 41.2/100,000, World standard) and 45% for females (from 56.6 to 31.7/100,000), and were proportionally comparable across subsequent age groups above age 45. The estimates for the age/period/cohort model were thus downwards both for the period and the cohort component although, in such a situation, it is difficult to disentangle the major underlying component.(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
OBJECTIVES: To evaluate the results of retrograde percutaneous screw fixation (PSF) in minimally or undisplaced acetabular fractures in a geriatric population. PATIENTS AND METHODS: Between July 1998 and July 2001, 21 consecutive patients with an acetabular fracture underwent fluoroscopic guided percutaneous fixation. The mean age was 81 years (range 67--90 years). In all cases, the fracture was minimally or undisplaced (<2mm). Two cannulated cancellous 7.3mm screws were inserted in a retrograde fashion to stabilise the posterior and the anterior column. Bed to chair transfer began after 24h. Weight bearing as tolerated was allowed at 4 weeks. RESULTS: Eighteen patients were reviewed at a mean of 3.5 years (range 2--5 years). Soft tissue dissection was minimal. There were no intraoperative or postoperative complications. At the latest follow-up there was no radiographical evidence of secondary displacement of fragments, degenerative changes, or screw failure. Fractures healed at a mean time of 12 weeks (range 8--15 weeks). Clinical results were satisfactory in 17 patients. CONCLUSION: Our results show that percutaneous screw fixation under fluoroscopic control is a safe technique to treat some pattern of acetabular fracture.
Resumo:
Stents have a long history in traditional valve surgery as both, porcine biological valves as well as pericardial valves are mounted on stents prior to implantation. Recently stent-mounted biological devices have been compressed up to the point, where they can be passed through a catheter. Various routes can be distinguished for implantation: open access, the trans-vascular route in antegrade or retrograde fashion, as well as direct trans-apical or trans-atrial access. Direct access has the potentialforvideo-endoscopic valve replacement. In theory, as well as in the experimental setting, valved stents have been implanted in tricuspid and caval position respectively, as well as in pulmonary, mitral and aortic locations. The largest clinical experience has been achieved in pulmonary position whereas current efforts target the aortic position.
Resumo:
OBJECTIVES: Our objective is to test the hypothesis that coronary endothelial function (CorEndoFx) does not change with repeated isometric handgrip (IHG) stress in CAD patients or healthy subjects. BACKGROUND: Coronary responses to endothelial-dependent stressors are important measures of vascular risk that can change in response to environmental stimuli or pharmacologic interventions. The evaluation of the effect of an acute intervention on endothelial response is only valid if the measurement does not change significantly in the short term under normal conditions. Using 3.0 Tesla (T) MRI, we non-invasively compared two coronary artery endothelial function measurements separated by a ten minute interval in healthy subjects and patients with coronary artery disease (CAD). METHODS: Twenty healthy adult subjects and 12 CAD patients were studied on a commercial 3.0 T whole-body MR imaging system. Coronary cross-sectional area (CSA), peak diastolic coronary flow velocity (PDFV) and blood-flow were quantified before and during continuous IHG stress, an endothelial-dependent stressor. The IHG exercise with imaging was repeated after a 10 minute recovery period. RESULTS: In healthy adults, coronary artery CSA changes and blood-flow increases did not differ between the first and second stresses (mean % change ±SEM, first vs. second stress CSA: 14.8%±3.3% vs. 17.8%±3.6%, p = 0.24; PDFV: 27.5%±4.9% vs. 24.2%±4.5%, p = 0.54; blood-flow: 44.3%±8.3 vs. 44.8%±8.1, p = 0.84). The coronary vasoreactive responses in the CAD patients also did not differ between the first and second stresses (mean % change ±SEM, first stress vs. second stress: CSA: -6.4%±2.0% vs. -5.0%±2.4%, p = 0.22; PDFV: -4.0%±4.6% vs. -4.2%±5.3%, p = 0.83; blood-flow: -9.7%±5.1% vs. -8.7%±6.3%, p = 0.38). CONCLUSION: MRI measures of CorEndoFx are unchanged during repeated isometric handgrip exercise tests in CAD patients and healthy adults. These findings demonstrate the repeatability of noninvasive 3T MRI assessment of CorEndoFx and support its use in future studies designed to determine the effects of acute interventions on coronary vasoreactivity.
Resumo:
The impact of navigator spatial resolution and navigator evaluation time on image quality in free-breathing navigator-gated 3D coronary magnetic resonance angiography (MRA), including real-time motion correction, was investigated in a moving phantom. Objective image quality parameters signal-to-noise ratio (SNR) and vessel sharpness were compared. It was found that for improved mage quality a short navigator evaluation time is of crucial importance. Navigator spatial resolution showed minimal influence on image quality.