934 resultados para PROTECTIVE-VENTILATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To examine the effect of an algorithm-based sedation guideline developed in a North American intensive care unit (ICU) on the duration of mechanical ventilation of patients in an Australian ICU. The intervention was tested in a pre-intervention, post-intervention comparative investigation in a 14-bed adult intensive care unit. Adult mechanically ventilated patients were selected consecutively (n =322) The pre-intervention and post-intervention groups were similar except for a higher number of patients with a neurological diagnosis in the pre-intervention group. An algorithm-based sedation guideline including a sedation scale was introduced using a multifaceted implementation strategy. The median duration of ventilation was 5.6 days in the post-intervention group, compared with 4.8 days for the pre-intervention group (P = 0.99). The length of stay was 8.2 days in the post-intervention group versus 7.1 days in the pre-intervention group (P = 0.04). There were no statistically significant differences for the other secondary outcomes, including the score on the Experience of Treatment in ICU 7 item questionnaire, number of tracheostomies and number of self-extubations. Records of compliance to recording the sedation score during both phases revealed that patients were slightly more deeply sedated when the guideline was used. The use of the algorithm-based sedation guideline did not reduce duration of mechanical ventilation in the setting of this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: fall-related hip fractures are one of the most common causes of disability and mortality in older age. The study aimed to quantify the relationship between lifestyle behaviours and the risk of fall-related hip fracture in community-dwelling older people. The purpose was to contribute evidence for the promotion of healthy ageing as a population-based intervention for falls injury prevention. Methods: a case-control study was conducted with 387 participants, with a case-control ratio of 1:2. Incident cases of fall-related hip fracture in people aged 65 and over were recruited from six hospital sites in Brisbane, Australia, in 2003-04. Community-based controls, matched by age, sex and postcode, were recruited via electoral roll sampling. A questionnaire designed to assess lifestyle risk factors, identified as determinants of healthy ageing, was administered at face-to-face interviews. Results: behavioural factors which had a significant independent protective effect on the risk of hip fracture included never smoking [adjusted odds ratio (AOR): 0.33 (0.12-0.88)], moderate alcohol consumption in mid- and older age [AOR: 0.49 (0.25-0.95)], not losing weight between mid- and older age [AOR: 0.36 (0.20-0.65)], playing sport in older age [AOR: 0.49 (0.29-0.83)] and practising a greater number of preventive medical care [AOR: 0.54 (0.32-0.94)] and self-health behaviours [AOR: 0.56 (0.33-0.94)]. Conclusion: with universal exposures, clear associations and modifiable behavioural factors, this study has contributed evidence to reduce the major public health burden of fall-related hip fractures using readily implemented population-based healthy ageing strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three distinct isolates of Candida albicans were used to establish systemic and oral infections in inbred mice that are genetically resistant or susceptible to tissue damage. Patterns of infection differed significantly between both yeasts and mouse strains. Systemic infection conferred significant protection against re-challenge with the homologous, but not the heterologous yeast; however, the protective effect was more evident in the tissue-susceptible CBA/CaH mice than in the resistant BALB/c strain. In contrast, oral infection induced protection against both homologous and heterologous oral challenge, although this was significant only in the CBA/CaH mice. CBA/CaH mice produced antibodies of both IgG1 and IgG2a subclasses, whereas BALB/c mice produced predominantly IgG1. Western blotting demonstrated considerable differences between epitopes recognised by serum antibodies from mice of both strains after immunisation with each of the three yeasts. Thus, different strains of yeast show considerable specificity in antibody responses elicited by either systemic or oral infection. (c) 2005 Elsevier SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although hepatitis B surface antigen (HBsAg) per se is highly immunogenic, its use as a vector for the delivery of foreign cytotoxic T-lymphocyte (CTL) epitopes has met with little success because of constraints on HBsAg stability and secretion imposed by the insertion of foreign sequence into critical hydrophobic/amphipathic regions. Using a strategy entailing deletion of DNA encoding HBsAg-specific CTL epitopes and replacement with DNA encoding foreign CTL epitopes, we have derived chimeric HBsAg DNA immunogens which elicited effector and memory CTL responses in vitro, and pathogen- and tumor-protective responses in vivo, when the chimeric HBsAg DNAs were used to immunize mice. We further show that HBsAg DNA recombinant for both respiratory syncytial virus and human papillomavirus CTL epitopes elicited simultaneous responses to both pathogens. These data demonstrate the efficacy of HBsAg DNA as a vector for the delivery of disease-relevant protective CTL responses. They also suggest the applicability of the approach of deriving chimeric HBsAg DNA immunogens simultaneously encoding protective CTL epitopes for multiple diseases. The DNAs we tested formed chimeric HBsAg virus-like particles (VLPs). Thus, our results have implications for the development of vaccination strategies using either chimeric HBsAg DNA or VLP vaccines. HBsAg is the globally administered vaccine for hepatitis B virus infection, inviting its usage as a vector for the delivery of immunogens from other diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes in heart rate (f(H)) and cloacal ventilation frequency (f(C)) were investigated in the Fitzroy turtle, Rheodytes leukops, under normoxic (17.85 kPa) and hypoxic (3.79 kPa) conditions at 25 degrees C. Given R. leukops' high reliance on aquatic respiration via the cloacal bursae, the objective Of this Study was to examine the effect of varying aquatic PO2 levels upon the expression of a bradycardia in a freely diving, bimodally respiring turtle. In normoxia, mean diving f(H) and f(C) for R. leukops remained constant with increasing submergence length, indicating that a bradycardia failed to develop during extended dives of up to 3 days. Alternatively, exposure to aquatic hypoxia resulted in the expression of a bradycardia as recorded by a decreasing mean diving f(H) with increasing dive duration. The observed bradycardia is attributed to a hypoxic-induced metabolic depression, possibly facilitated by a concurrent decrease in f(C). Results suggest that R. leukops alters its strategy from aquatic O-2 extraction via cloacal respiration in normoxia to O-2 conservation when exposed to aquatic hypoxia for the purpose of extending dive duration. Upon surfacing, a significant tachycardia was observed for R. leukops regardless of aquatic PO2, presumably functioning to rapidly equilibrate blood and tissue gas tensions with alveolar gas to reduce surfacing duration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Functional electrical impedance tomography (EIT) measures relative impedance change that occurs in the chest during a distinct observation period and an EIT image describing regional relative impedance change is generated. Analysis of such an EIT image may be erroneous because it is based on an impedance signal that has several components. Most of the change in relative impedance in the chest is caused by air movement but other physiological events such as cardiac activity change in end expiratory level or pressure swings originating from a ventilator circuit can influence the impedance signal. We obtained EIT images and signals in spontaneously breathing healthy adults, in extremely prematurely born infants on continuous positive airway pressure and in ventilated sheep on conventional mechanical or high frequency oscillatory ventilation (HFOV). Data were analyzed in the frequency domain and results presented after band pass filtering within the frequency range of the physiological event of interest. Band pass filtering of EIT data is necessary in premature infants and on HFOV to differentiate and eliminate relative impedance changes caused by physiological events other than the one of interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Caudal block results in a motor blockade that can reduce abdominal wall tension. This could interact with the balance between chest wall and lung recoil pressure and tension of the diaphragm, which determines the static resting volume of the lung. On this rationale, we hypothesised that caudal block causes an increase in functional residual capacity and ventilation distribution in anaesthetised children. Fifty-two healthy children (15-30 kg, 3-8 years of age) undergoing elective surgery with general anaesthesia and caudal block were studied and randomly allocated to two groups: caudal block or control. Following induction of anaesthesia, the first measurement was obtained in the supine position (baseline). All children were then turned to the left lateral position and patients in the caudal block group received a caudal block with bupivacaine. No intervention took place in the control group. After 15 nun in the supine position, the second assessment was performed. Functional residual capacity and parameters of ventilation distribution were calculated by a blinded reviewer. Functional residual capacity was similar at baseline in both groups. In the caudal block group, the capacity increased significantly (p < 0.0001) following caudal block, while in the control group, it remained unchanged. In both groups, parameters of ventilation distribution were consistent with the changes in functional residual capacity. Caudal block resulted in a significant increase in functional residual capacity and improvement in ventilation homogeneity in comparison with the control group. This indicates that caudal block might have a beneficial effect on gas exchange in anaesthetised, spontaneously breathing preschool-aged children with healthy lungs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structure of a comprehensive research project into mine fires study applying the Ventgraph mine fire simulation software, preplanning of escape scenarios and general interaction with rescue responses is outlined. The project has Australian Coal Association Research Program (ACARP) funding and also relies on substantial mining company site support. This practical input from mine operators is essential and allows the approach to be introduced in the most creditable way. The effort is built around the introduction of fire simulation computer software to the Australian mining industry and the consequent modelling of fire scenarios in selected different mine layouts. Application of the simulation software package to the changing mine layouts requires experience to achieve realistic outcomes. Most Australian mines of size currently use a ventilation network simulation program. Under the project a small subroutine has been written to transfer the input data from the existing mine ventilation network simulation program to ‘Ventgraph’. This has been tested successfully. To understand fire simulation behaviour on the mine ventilation system, it is necessary to understood the possible effects of mine fires on various mine ventilation systems correctly first. Case studies demonstrating the possible effects of fires on some typical Australian coal mine ventilation circuits have been examined. The situation in which there is some gas make at the face and effects with fire have also been developed to emphasise how unstable and dangerous situations may arise. The primary objective of the part of the study described in this paper is to use mine fire simulation software to gain better understanding of how spontaneous combustion initiated fires can interact with the complex ventilation behaviour underground during a substantial fire. It focuses on the simulation of spontaneous combustion sourced heatings that develop into open fires. Further, it examines ventilation behaviour effects of spontaneous combustion initiated pillar fires and examines the difficulties these can be present if a ventilation reversal occurs. It also briefly examines simulation of use of the inertisation to assist in mine recovery. Mine fires are recognised across the world as a major hazard issue. New approaches allowing improvement in understanding their consequences have been developed as an aid in handling this complex area.