949 resultados para Oil pollution of water.
Resumo:
In many designs for radioactive waste repositories, cement and clay will come into direct contact. The geochemical contrast between cement and clay will lead to mass fluxes across the interface, which consequently results in alteration of structural and transport properties of both materials that may affect the performance of the multi-barrier system. We present an experimental approach to study cement-clay interactions with a cell to accommodate small samples of cement and clay. The cell design allows both in situ measurement of water content across the sample using neutron radiography and measurement of transport parameters using through-diffusion tracer experiments. The aim of the high- resolution neutron radiography experiments was to monitor changes in water content (porosity) and their spatial extent. Neutron radiographs of several evolving cement-clay interfaces delivered quantitative data which allow resolving local water contents within the sample domain. In the present work we explored the uncertainties of the derived water contents with regard to various input parameters and with regard to the applied image correction procedures. Temporal variation of measurement conditions created absolute uncertainty of the water content in the order of ±0.1 (m3/m3), which could not be fully accounted for by correction procedures. Smaller relative changes in water content between two images can be derived by specific calibrations to two sample regions with different, invariant water contents.
Resumo:
The surfaces of many objects in the Solar System comprise substantial quantities of water ice sometimes mixed with minerals and/or organic molecules. The sublimation of the ice changes the structural and optical properties of these objects. We present laboratory data on the evolution of the structure and the visible and near-infrared spectral reflectance of icy surface analogues of cometary ices, made of water ice, complex organic matter (tholins) and silicates, as they undergo sublimation under low temperature (<-70°C) and pressure (10-⁵mbar) conditions inside the SCITEAS simulation chamber. As the water ice sublimated, we observed in situ the formation of a porous sublimation lag deposit, or sublimation mantle, at the top of the ice. This mantle is a network of filaments made of the non-volatile particles. Organics or phyllosilicates grains, able to interact via stronger inter-particulate forces than olivine grains, can form a foam-like structure having internal cohesiveness, holding olivine grains together. As this mantle builds-up, the band depths of the sub-surface water ice are attenuated until complete extinction under only few millimeters of mantle. Optically thick sublimation mantles are mainly featureless in the near infrared. The absorption bands of the minerals present in the mantle are weak, or even totally absent if minerals are mixed with organics which largely dominate the VIS–NIR reflectance spectrum. During sublimation, ejections of large fragments of mantle, triggered by the gas flow, expose ice particles to the surface. The contrast of brightness between mantled and ice-exposed areas depends on the wavelength range and the dust/ice ratio considered. We describe how the chemical nature of the non-volatiles, the size of their particles, the way they are mixed with the ice and the dust/ice mass ratio influence the texture, activity and spectro-photometric properties of the sublimation mantles. These data provide useful references for interpreting remote-sensing observations of comets and also icy satellites or trans-neptunian objects.
Resumo:
The promoting effect of water on the electrochemical reduction of carbon dioxide (CO2) from non-aqueous solvents has been studied by means of cyclic voltammetry and in-situ surface-enhanced infrared absorption spectroscopy (SEIRAS). CO2 electroreduction on gold is known to be highly selective towards CO formation in aqueous and in non-aqueous media. The use of non-aqueous solvents is advantageous due to the significantly increased solubility of CO2 compared to aqueous systems. However, in the absence of any proton source, extremely high overpotentials are required for the CO2 electroreduction. In this work, we demonstrate for the first time a tremendous accelerating effect of water additives on the electroreduction of CO2 taking place at gold/acetonitrile interfaces. Already moderate amounts of water, in the concentration range of 0.5 to 0.7 M, are sufficient to decrease significantly the overpotential of CO2 reduction while keeping the CO2 concentration as high as in the pure acetonitrile. The effect of water additives on the mechanism of CO2 electroreduction on gold is discussed on the basis of electrochemical and IR spectroscopic data. The results obtained from gold are compared to analogue experiments carried out on platinum.
Resumo:
Permanently shadowed regions at the poles of the Moon and Mercury have been pointed out as candidates for hosting water ice at their surface. We have measured in the laboratory the visible and near infrared spectral range (VIS-NIR) bidirectional reflectance of intimate mixtures of water ice and the JSC-1AF lunar simulant for different ice concentrations, particle sizes, and measurement geometries. The nonlinearity between the measured reflectance and the amount of ice in the mixture can be reproduced to some extent by the mixing formulas of standard reflectance models, in particular, those of Hapke and Hiroi, which are tested here. Estimating ice concentrations from reflectance data without knowledge of the mixing coefficientsstrongly dependent on the size/shape of the grainscan result in large errors. According to our results, it is possible that considerable amounts of water ice might be intimately mixed in the regolith of the Moon and Mercury without producing noticeable photometric signatures.
Resumo:
This is the Maple code to support the molecular dynamics of a water monomer molecule, allowing investigation of the classical vibrations of this molecule.
Resumo:
Simulation of the classical molecular dynamics of a water molecule can be useful in explaining normal modes of motion, Fourier Transforms, and fundamental frequencies of vibration, as illustrated herein.
Resumo:
West Nile Virus (WNV) is an arboviral disease that has affected hundreds of residents in Harris County, Texas since its introduction in 2002. Persistent infection, lingering sequelae and other long-term symptoms of patients reaffirm the need for prevention of this important vector-borne disease. This study aimed to determine if living within 400m of a water body increases one’s odds of infection with WNV. Additionally, we wanted to determine if one’s proximity to a particular water type or water body source increased one’s odds of infection with WNV.^ 145 cases’ addresses were abstracted from the initial interview and consent records from a cohort of patients (Epidemiology of Arboviral Encephalitis in Houston study, HSC-SPH-03-039). After applying inclusion criteria, 140 cases were identified for analysis. 140 controls were selected for analysis using a population proportionate to size model and US Census Bureau data. MapMarker USA v14 was used to geocode the cases’ addresses. Both cases’ and controls’ coordinates were uploaded onto a Harris County water shapefile in MapInfo Professional v9.5.1. Distance in meters to the closest water source, closest water source type, and closest water source name were recorded.^ Analysis of Variance (p=0.329, R2 = 0.0034) indicated no association between water body distance and risk of WNV disease. Living near a creek (x2 = 11.79, p < 0.001), or the combined group of creek and gully (x 2 = 14.02, p < 0.001) were found to be strongly associated with infection of WNV. Living near Cypress Creek and its feeders (x2 = 15.2, p < 0.001) was found to be strongly associated with WNV infection. We found that creek and gully habitats, particularly Cypress Creek, were preferential for the local disease transmitting Culex quinquefasciatus and reservoir avian population.^
Resumo:
Developing countries are heavily burdened by limited access to safe drinking water and subsequent water-related diseases. Numerous water treatment interventions combat this public health crisis, encompassing both traditional and less-common methods. Of these, water disinfection serves as an important means to provide safe drinking water. Existing literature discusses a wide range of traditional treatment options and encourages the use of multi-barrier approaches including coagulation-flocculation, filtration, and disinfection. Most sources do not delve into approaches specifically appropriate for developing countries, nor do they exclusively examine water disinfection methods.^ The objective of this review is to focus on an extensive range of chemical, physio-chemical, and physical water disinfection techniques to provide a compilation, description and evaluation of options available. Such an objective provides further understanding and knowledge to better inform water treatment interventions and explores alternate means of water disinfection appropriate for developing countries. Appropriateness for developing countries corresponds to the effectiveness of an available, easy to use disinfection technique at providing safe drinking water at a low cost.^ Among chemical disinfectants, SWS sodium hypochlorite solution is preferred over sodium hypochlorite bleach due to consistent concentrations. Tablet forms are highly recommended chemical disinfectants because they are effective and very easy to use, but also because they are stable. Examples include sodium dichloroisocyanurate, calcium hypochlorite, and chlorine dioxide, which vary in cost depending on location and availability. Among physio-chemical disinfection options, electrolysis which produces mixed oxidants (MIOX) provides a highly effective disinfection option with a higher upfront cost but very low cost over the long term. Among physical disinfection options, solar disinfection (SODIS) applications are effective, but they treat only a fixed volume of water at a time. They come with higher initial costs but very low on-going costs. Additional effective disinfection techniques may be suitable depending on the location, availability and cost.^