985 resultados para Non-technical losses
Resumo:
Introduction & Objectives: Several factors may influence the decision to pursue nonsurgical modalities for the treatment of non-melanoma skin cancer. Topical photodynamic therapy (PDT) is a non-invasive alternative treatment reported to have a high efficacy when using standardized protocols in Bowen’s disease (BD), superficial basal cell carcinoma (BCC) and in thin nodular BCC. However, long-term recurrence studies are lacking. The aim of this study was to evaluate the long-term efficacy of PDT with topical methylaminolevulinate (MAL) for the treatment of BD and BCC in a dermato-oncology department. Materials & Methods: All patients with the diagnosis of BD or BCC, treated with MAL-PDT from the years 2004 to 2008, were enrolled. Treatment protocol included two MAL-PDT sessions one week apart repeated at three months when incomplete response, using a red light dose of 37-40 J/cm2 and an exposure time of 8’20’’. Clinical records were retrospectively reviewed, and data regarding age, sex, tumour location, size, treatment outcomes and recurrence were registered. Descriptive analysis was performed using chi square tests, followed by survival analysis with the Kaplan-Meier and Cox regression models. Results: Sixty-eight patients (median age 71.0 years, P25;P75=30;92) with a total of 78 tumours (31 BD, 45 superficial BCC, 2 nodular BCC) and a median tumour size of 5 cm2 were treated. Overall, the median follow-up period was 43.5 months (P25;P75=0;100), and a total recurrence rate of 33.8% was observed (24.4 % for BCC vs. 45.2% for BD). Estimated recurrence rates for BCC and BD were 5.0% vs. 7.4% at 6 months, 23.4% vs. 27.9% at 12 months, and 30.0% vs. 72.4% at 60 months. Both age and diagnosis were independent prognostic factors for recurrence, with significantly higher estimated recurrence rates in patients with BD (p=0.0036) or younger than 58 years old (p=0.039). The risk of recurrence (hazard ratio) was 2.4 times higher in patients with BD compared to superficial BCC (95% CI:1.1-5.3; p=0.033), and 2.8 times higher in patients younger than 58 years old (95% CI:1.2-6.5; p=0.02). Conclusions: In the studied population, estimated recurrence rates are higher than those expected from available literature, possibly due to a longer follow-up period. To the authors’ knowledge there is only one other study with a similar follow-up period, regarding BCC solely. BD, as an in situ squamous cell carcinoma, has a higher tendency to recur than superficial BCC. Despite greater cosmesis, PDT might no be the best treatment option for young patients considering their higher risk of recurrence.
Resumo:
Com a alteração da legislação energética em Portugal, nomeadamente a implementação da legislação de Micro e Minigeração, a produção distribuída cresceu de forma exponencial na rede elétrica nacional, diminuindo por um lado as perdas no transporte e distribuição, e por outro aumentando a complexidade na gestão do trânsito de potência ao Distribuidor. No entanto a motivação desta dissertação prende-se com o facto de que as centrais de produção distribuída, em particular as de tecnologia fotovoltaica, pela sua dimensão, serem instaladas nos pontos de consumo, em paralelo com a instalação elétrica de utilização do cliente e como tal, têm sido verificadas diversas anomalias no funcionamento e exploração das mesmas, por influência da má qualidade de energia resultante das más condições de funcionamento e exploração em que se encontram as instalações de consumo. A presente dissertação pretende apresentar uma descrição das anomalias mais frequentes verificadas nas centrais fotovoltaicas de minigeração com origem na qualidade da energia que transita das instalações elétricas de consumo ligadas ao mesmo ponto de interligação com a rede elétrica nacional. Como base de fundamento, foram demonstradas através de três casos práticos reais, algumas das mais frequentes e prejudiciais anomalias descritas na presente dissertação. Foram escolhidos 3 casos reais com diferentes tipos de instalação de consumo sendo que um deles não apresenta qualquer anomalia de forma a comprovar o bom funcionamento em condições normais de ambas as instalações. Foram encontradas e demonstradas várias soluções paras os diferentes tipos de anomalias, no entanto esta dissertação vai permitir não só a resolução deste tipo de anomalias em centrais fotovoltaicas em exploração e já com prejuízos avultados mas também introduzir em futuras instalações a análise da qualidade da energia nas instalações de consumo em fase preliminar de estudo de implementação de centrais fotovoltaicas de minigeração e de autoconsumo, precavendo futuros problemas de rentabilidade técnico-económica. Este estudo, irá certamente servir de motor de impulsão para a preocupação com a Qualidade da Energia essencialmente dentro das instalações elétricas de consumo sensibilizando os seus gestores energéticos. Poderá ainda impulsionar a reformulação do Regulamento de Qualidade de Serviço para exigências ainda mais apertadas de forma a incorporar algumas das anomalias aqui descritas, sendo por isso um elemento de alerta para todos os “Players” do Sistema Elétrico Nacional tendo como limite a melhoria continua da Segurança e da Qualidade da energia na rede elétrica beneficiando da sensibilização de todos os intervenientes.
Resumo:
A crescente necessidade de reduzir a dependência energética e a emissão de gases de efeito de estufa levou à adoção de uma série de políticas a nível europeu com vista a aumentar a eficiência energética e nível de controlo de equipamentos, reduzir o consumo e aumentar a percentagem de energia produzida a partir de fontes renováveis. Estas medidas levaram ao desenvolvimento de duas situações críticas para o setor elétrico: a substituição das cargas lineares tradicionais, pouco eficientes, por cargas não-lineares mais eficientes e o aparecimento da produção distribuída de energia a partir de fontes renováveis. Embora apresentem vantagens bem documentadas, ambas as situações podem afetar negativamente a qualidade de energia elétrica na rede de distribuição, principalmente na rede de baixa tensão onde é feita a ligação com a maior parte dos clientes e onde se encontram as cargas não-lineares e a ligação às fontes de energia descentralizadas. Isto significa que a monitorização da qualidade de energia tem, atualmente, uma importância acrescida devido aos custos relacionados com perdas inerentes à falta de qualidade de energia elétrica na rede e à necessidade de verificar que determinados parâmetros relacionados com a qualidade de energia elétrica se encontram dentro dos limites previstos nas normas e nos contratos com clientes de forma a evitar disputas ou reclamações. Neste sentido, a rede de distribuição tem vindo a sofrer alterações a nível das subestações e dos postos de transformação que visam aumentar a visibilidade da qualidade de energia na rede em tempo real. No entanto, estas medidas só permitem monitorizar a qualidade de energia até aos postos de transformação de média para baixa tensão, não revelando o estado real da qualidade de energia nos pontos de entrega ao cliente. A monitorização nestes pontos é feita periodicamente e não em tempo real, ficando aquém do necessário para assegurar a deteção correta de problemas de qualidade de energia no lado do consumidor. De facto, a metodologia de monitorização utilizada atualmente envolve o envio de técnicos ao local onde surgiu uma reclamação ou a um ponto de medição previsto para instalar um analisador de energia que permanece na instalação durante um determinado período de tempo. Este tipo de monitorização à posteriori impossibilita desde logo a deteção do problema de qualidade de energia que levou à reclamação, caso não se trate de um problema contínuo. Na melhor situação, o aparelho poderá detetar uma réplica do evento, mas a larga percentagem anomalias ficam fora deste processo por serem extemporâneas. De facto, para detetar o evento que deu origem ao problema é necessário monitorizar permanentemente a qualidade de energia. No entanto este método de monitorização implica a instalação permanente de equipamentos e não é viável do ponto de vista das empresas de distribuição de energia já que os equipamentos têm custos demasiado elevados e implicam a necessidade de espaços maiores nos pontos de entrega para conter os equipamentos e o contador elétrico. Uma alternativa possível que pode tornar viável a monitorização permanente da qualidade de energia consiste na introdução de uma funcionalidade de monitorização nos contadores de energia de determinados pontos da rede de distribuição. Os contadores são obrigatórios em todas as instalações ligadas à rede, para efeitos de faturação. Tradicionalmente estes contadores são eletromecânicos e recentemente começaram a ser substituídos por contadores inteligentes (smart meters), de natureza eletrónica, que para além de fazer a contagem de energia permitem a recolha de informação sobre outros parâmetros e aplicação de uma serie de funcionalidades pelo operador de rede de distribuição devido às suas capacidades de comunicação. A reutilização deste equipamento com finalidade de analisar a qualidade da energia junto dos pontos de entrega surge assim como uma forma privilegiada dado que se trata essencialmente de explorar algumas das suas características adicionais. Este trabalho tem como objetivo analisar a possibilidade descrita de monitorizar a qualidade de energia elétrica de forma permanente no ponto de entrega ao cliente através da utilização do contador elétrico do mesmo e elaborar um conjunto de requisitos para o contador tendo em conta a normalização aplicável, as características dos equipamentos utilizados atualmente pelo operador de rede e as necessidades do sistema elétrico relativamente à monitorização de qualidade de energia.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
The prevalence of antibodies against Equine Influenza Virus (EIV) was determined in 529 equines living on ranches in the municipality of Poconé, Pantanal area of Brazil, by means of the hemagglutination inhibition test, using subtype H3N8 as antigen. The distribution and possible association among positive animal and ranches were evaluated by the chi-square test, spatial autoregressive and multiple linear regression models. The prevalence of antibodies against EIV was estimated at 45.2% (95% CI 30.2 - 61.1%) with titers ranging from 20 to 1,280 HAU. Seropositive equines were found on 92.0% of the surveyed ranches. Equine from non-flooded ranches (66.5%) and negativity in equine infectious anemia virus (EIAV) (61.7%) were associated with antibodies against EIV. No spatial correlation was found among the ranches, but the ones located in non-flooded areas were associated with antibodies against EIV. A negative correlation was found between the prevalence of antibodies against EIV and the presence of EIAV positive animals on the ranches. The high prevalence of antibodies against EIV detected in this study suggests that the virus is circulating among the animals, and this statistical analysis indicates that the movement and aggregation of animals are factors associated to the transmission of the virus in the region.
Resumo:
The causative agent of cholera, Vibrio cholerae, can enter into a viable but non-culturable (VBNC) state in response to unfavorable conditions. The aim of this study was to evaluate the in situ survival of V. cholerae in an aquatic environment of the Southern Caribbean Sea, and its induction and resuscitation from the VBNC state. V. cholerae non-O1, non-O139 was inoculated into diffusion chambers placed at the Cuare Wildlife Refuge, Venezuela, and monitored for plate, total and viable cells counts. At 119 days of exposure to the environment, the colony count was < 10 CFU/mL and a portion of the bacterial population entered the VBNC state. Additionally, the viability decreased two orders of magnitude and morphological changes occurred from rod to coccoid cells. Among the aquatic environmental variables, the salinity had negative correlation with the colony counts in the dry season. Resuscitation studies showed significant recovery of cell cultivability with spent media addition (p < 0.05). These results suggest that V. cholerae can persist in the VBNC state in this Caribbean environment and revert to a cultivable form under favorable conditions. The VBNC state might represent a critical step in cholera transmission in susceptible areas.
Resumo:
BACKGROUND: Wireless capsule endoscopy has been introduced as an innovative, non-invasive diagnostic technique for evaluation of the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the output of this technique is an 8 hours video, whose analysis by the expert physician is very time consuming. Thus, a computer assisted diagnosis tool to help the physicians to evaluate CE exams faster and more accurately is an important technical challenge and an excellent economical opportunity. METHOD: The set of features proposed in this paper to code textural information is based on statistical modeling of second order textural measures extracted from co-occurrence matrices. To cope with both joint and marginal non-Gaussianity of second order textural measures, higher order moments are used. These statistical moments are taken from the two-dimensional color-scale feature space, where two different scales are considered. Second and higher order moments of textural measures are computed from the co-occurrence matrices computed from images synthesized by the inverse wavelet transform of the wavelet transform containing only the selected scales for the three color channels. The dimensionality of the data is reduced by using Principal Component Analysis. RESULTS: The proposed textural features are then used as the input of a classifier based on artificial neural networks. Classification performances of 93.1% specificity and 93.9% sensitivity are achieved on real data. These promising results open the path towards a deeper study regarding the applicability of this algorithm in computer aided diagnosis systems to assist physicians in their clinical practice.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Física
Resumo:
As operações de maquinagem de componentes tendo em vista os mais diversos sectores de actividade têm registado um crescimento sustentável em Portugal, devido a inúmeros factores como a modernização do nosso parque de equipamentos, a competitividade da nossa mão-de-obra e a qualidade patenteada pelos serviços prestados pelas nossas empresas, cada vez mais conscientes da importância que os clientes internacionais assumem na sua actividade, da necessidade de cumprimento dos compromissos estabelecidos em termos de prazo de entrega e da procura incessante de novos mercados e sectores de actividade que potenciem um valor-acrescentado mais atractivo do produto. As solicitações do mercado no sector de actividade de prestação de serviços de maquinagem são imensas, e sempre extremamente condicionadas em termos de tempo de resposta. Por outro lado, os prestadores deste tipo de serviço ficam limitados por duas situações-limite: uma orçamentação por defeito poderá conduzir a prejuízos indesejáveis, ou mesmo incomportáveis, enquanto um preço excessivamente elevado poderá afastar o possível cliente e impedir a conquista de um novo projecto. Orçamentar depressa e bem é uma operação complexa, que requer uma análise muito cuidada dos desenhos fornecidos pelo possível cliente, delinear a sequência operatória, salvaguardar as tolerâncias e tipos de acabamento pretendidos, minimizar as operações de fixação e seleccionar as melhores ferramentas para efectuar o trabalho pretendido. Este trabalho, desenvolvido para a TECNOLANEMA, empresa do Grupo LANEMA, que é especialista na produção de peças em plástico técnico e em ligas de alumínio para os mais diversos sectores de actividade, tanto em Portugal como no Estrangeiro. O trabalho desenvolvido visou criar uma aplicação informática que permitisse elaborar orçamentos de forma rápida e precisa, através de determinados factores-chave previamente estudados. O projecto foi concluído e testado com sucesso na empresa.
Estudo de uma bomba de calor de expansão direta assistida por energia solar para a preparação de AQS
Resumo:
Este estudo consiste na caracterização da eficiência energética de uma bomba de calor de expansão direta que utiliza a energia solar como fonte térmica. De uma forma geral, teve-se a obrigação de procurar cada vez mais recursos renováveis e neste sentido a bomba de calor de expansão direta tem um papel importante no aquecimento de águas quentes sanitárias (AQS). Como ponto de partida, foi realizada uma descrição detalhada sobre todos os equipamentos da bomba de calor e elaborado um desenho técnico que identifica todos os componentes. No laboratório (casa inteligente) realizaram-se vários ensaios a fim de interpretar com rigor os resultados obtidos do desempenho da bomba de calor (COP) e do fator médio de desempenho sazonal (SPF). No início, realizaram-se ensaios para determinar as perdas estáticas do sistema termodinâmico, de seguida foram elaborados ensaios segundo a norma EN 16147 e por fim, ensaios de acordo com o perfil de utilização de AQS definido. No estudo experimental do COP, obteve-se uma elevada eficiência energética com um valor médio de 4,12. O COP aumenta para valores médios de 5 quando a temperatura de água no termoacumulador desce para 35ºC. Verificou-se que durante o período diurno o COP aumenta aproximadamente de 10% relativamente ao período noturno. A potência elétrica é mais elevada (450W) quando a água no termoacumulador está perto da temperatura desejável (55ºC), originando um esforço maior da bomba de calor. No estudo experimental do SPF, verificou-se que nos ensaios segundo a norma EN16147 os valores obtidos variaram entre 1,39 e 1,50 (Classe “B”). No estudo realizado de acordo com o perfil de utilização de AQS definido pelo utilizador, o SPF é superior em 12% relativamente ao obtido segundo os ensaios realizados de acordo a norma EN16147. Verificou-se que o aumento da temperatura do ar exterior implica um aumento do SPF (cerca de 2% a 5%), enquanto a energia solar não influência nos resultados.
Resumo:
The occurrence of leprosy has decreased in the world but the perspective of its elimination has been questioned. A proposed control measure is the use of post-exposure chemoprophylaxis (PEP) among contacts, but there are still questions about its operational aspects. In this text we discuss the evidence available in literature, explain some concepts in epidemiology commonly used in the research on this topic, analyze the appropriateness of implementing PEP in the context of Brazil, and answer a set of key questions. We argue some points: (1) the number of contacts that need to receive PEP in order to prevent one additional case of disease is not easy to be generalized from the studies; (2) areas covered by the family health program are the priority settings where PEP could be implemented; (3) there is no need for a second dose; (4) risk for drug resistance seems to be very small; (5) the usefulness of a serological test to identify a higher risk group of individuals among contacts is questionable. Given that, we recommend that, if it is decided to start PEP in Brazil, it should start on a small scale and, as new evidence can be generated in terms of feasibility, sustainability and impact, it could move up a scale, or not, for a wider intervention.
Resumo:
Chronic infection by hepatitis C virus (HCV) is one of the main risk factors for the development of liver cirrhosis and hepatocellular carcinoma. However, the emergence of hepatocellular carcinoma (HCC) in non-cirrhotic HCV patients, especially after sustained virological response (SVR) is an unusual event. Recently, it has been suggested that HCV genotype 3 may have a particular oncogenic mechanism, but the factors involved in these cases as well as the profile of these patients are still not fully understood. Thus, we present the case of a non-cirrhotic fifty-year-old male with HCV infection, genotype 3a, who developed HCC two years after treatment with pegylated-interferon and ribavirin, with SVR, in Brazil.
Resumo:
Dissertation presented to obtain the PhD degree in Biology
Resumo:
This study examined the association between oral candidiasis in elderly users and nonusers of prosthesis and its predisposing factors. To this end, we performed a cross-sectional study where saliva samples from 48 patients were collected they used prosthesis and 43 patients (control group) who did not use. Among the 91 patients, Candida spp were isolated in 40 (83.3%) who used prosthesis and in 23 (53.5%) in the control group. A statistically significant association was determined between the two groups, the isolation of yeasts and dental prosthesis (p < 0.05, OR = 4.3). The most common etiological agent was Candida albicans (37 isolates), with 23 (62.2%) in the denture group and 14 (37.8%) (control group). Among patients who presented clinical manifestations of oral candidiasis (n = 24), 83.3% (n = 20) belonged to the group that wore dentures, while only 16.7% (n = 4) belonged to the control group. Elderly patients with diabetes had 4.4 times higher estimated risk of developing oral candidiasis when compared with individuals without this condition. There was no statistically significant association between being user prostheses and have diabetes with the onset of candidiasis. No statistically significant association was determined between xerostomia, use of prosthesis and oral candidiasis. The use of prosthetics and poor oral hygiene in elderly patients predisposes to the development of oral candidiasis.