922 resultados para Nadir Shah, Shah of Iran, 1688-1747.


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Presbyopia is an age-related eye condition where one of the signs is the reduction in the amplitude of accommodation, resulting in the loss of ability to change the eye's focus from far to near. It is the most common age-related ailments affecting everyone around their mid-40s. Methods for the correction of presbyopia include contact lens and spectacle options but the surgical correction of presbyopia still remains a significant challenge for refractive surgeons. Surgical strategies for dealing with presbyopia may be extraocular (corneal or scleral) or intraocular (removal and replacement of the crystalline lens or some type of treatment on the crystalline lens itself). There are however a number of limitations and considerations that have limited the widespread acceptance of surgical correction of presbyopia. Each surgical strategy presents its own unique set of advantages and disadvantages. For example, lens removal and replacement with an intraocular lens may not be preferable in a young patient with presbyopia without a refractive error. Similarly treatment on the crystalline lens may not be a suitable choice for a patient with early signs of cataract. This article is a review of the options available and those that are in development stages and are likely to be available in the near future for the surgical correction of presbyopia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper extends the existing evidence on the relationship between Information and Communication Technology (ICT) and productivity using data from the entire Iranian manufacturing sector (22 industries) over the period 1993?1999. Estimates of efficiency using panel data confirm the positive and significant impact of ICT investments on productivity. Our finding is consistent with the most recent literatures in the context of developed and a few middle-income developing countries. Human capital and increasing ICT capital are probably two determining factors in gaining the positive payoffs from ICT investments in Iran.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To study the visual and refractive outcomes after laser-assisted subepithelial keratectomy (LASEK) performed with a 213 nm solid-state laser for a broad range of refractive errors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Investigations of relationships between the specific personality variable, locus of control (LOC, Rotter, 1966) and driver behaviour or accidents have returned contrasting results. Review suggests dependence on gender or experience characteristics of participants, suggesting these factors interact with LOC to influence driving. Relationships were investigated in terms of influence on the eight driving styles of the Multidimensional Driving Style Inventory (MDSI, Taubman-Ben-Ari, Mikulincer & Gillarth, 2004) in young drivers (18-29 years). Gender and LOC differences in driving styles previously related to accidents were proposed. It was also proposed that driving experience influences driving style, and LOC influences effect of driving experience. Gender differences were found for dissociative, anxious, patient, risky, angry and high velocity styles. Women had more external LOC than men, and driver stress styles increased with more external LOC, but reduced with increased driving experience, but so did patient style. High velocity style increased with experience. Controlling for LOC revealed important gender differences in effect of experience: positive effects for men (reducing angry and high velocity, increasing carefulness) and negative effects for women (increasing angry and higher velocity, reducing carefulness). Findings suggest negative influence of high internal LOC on young men in terms of its interaction with experience.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To develop a questionnaire that subjectively assesses near visual function in patients with 'accommodating' intraocular lenses (IOLs). Methods: A literature search of existing vision-related quality-of-life instruments identified all questions relating to near visual tasks. Questions were combined if repeated in multiple instruments. Further relevant questions were added and item interpretation confirmed through multidisciplinary consultation and focus groups. A preliminary 19-item questionnaire was presented to 22 subjects at their 4-week visit post first eye phacoemulsification with 'accommodative' IOL implantation, and again 6 and 12 weeks post-operatively. Rasch Analysis, Frequency of Endorsement, and tests of normality (skew and kurtosis) were used to reduce the instrument. Cronbach's alpha and test-retest reliability (intraclass correlation coefficient, ICC) were determined for the final questionnaire. Construct validity was obtained by Pearson's product moment correlation (PPMC) of questionnaire scores to reading acuity (RA) and to Critical Print Size (CPS) reading speed. Criterion validity was obtained by receiver operating characteristic (ROC) curve analysis and dimensionality of the questionnaire was assessed by factor analysis. Results: Rasch Analysis eliminated nine items due to poor fit statistics. The final items have good separation (2.55), internal consistency (Cronbach's α = 0.97) and test-retest reliability (ICC = 0.66). PPMC of questionnaire scores with RA was 0.33, and with CPS reading speed was 0.08. Area under the ROC curve was 0.88 and Factor Analysis revealed one principal factor. Conclusion: The pilot data indicates the questionnaire to be internally consistent, reliable and a valid instrument that could be useful for assessing near visual function in patients with 'accommodating' IOLS. The questionnaire will now be expanded to include other types of presbyopic correction. © 2007 British Contact Lens Association.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE:To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS:Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, and IOL flexure with aberrometry, each viewing a target at 0.0 to 4.00 diopters of accommodative demand. RESULTS:Pupil size decreased by 0.62+/-0.41 mm on increasing accommodative demand, but the Tetraflex IOL was relatively fixed in position within the eye. The ocular aberrations of the eye changed with increased accommodative demand, but not in a consistent manner among individuals. Those aberrations that appeared to be most affected were defocus, vertical primary and secondary astigmatism, vertical coma, horizontal and vertical primary and secondary trefoil, and spherical aberration. CONCLUSIONS:Some of the reported near vision benefits of the Tetraflex accommodating IOL appear to be due to changes in the optical aberrations because of the flexure of the IOL on accommodative effort rather than forward movement within the capsular bag.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To compare distance and near visual performance with a zero-aberration aspheric intraocular lens (IOL) (Softec HD, Lenstec, Inc. FL, USA) with that of an otherwise identical, but spherical IOL (Softec 1). Setting: Department of Ophthalmology, Solihull Hospital, West Midlands, United Kingdom. Methods: This prospective study comprised 37 patients with a Softec 1 spherical IOL implanted in one eye, who underwent phacoemulsification and received the Softec HD aspheric IOL in the fellow eye. One month post-operatively, unaided distance and near vision, residual refraction, best spectacle corrected distance and near visual acuity, reading speed, pseudoaccommodation and photopic contrast sensitivity were recorded. Wavefront analysis enabled comparison of higher order aberrations between the IOLs. Results: Prior to surgery, the Softec 1 and Softec HD eyes were not significantly different. Post-operatively, unaided vision, best spectacle corrected visual acuity and residual refraction were not significantly different between the eyes, nor were there significant differences observed between the measured wavefront aberrations. Once implanted, the range of focus was significantly better in the Softec HD IOL eye than the Softec 1 IOL eye and, although reading speed was equivalent to the Softec 1 eye, the print size at which this could be achieved was significantly smaller. Conclusions: Depth of field was significantly improved with the aspheric IOL compared with the spherical IOL, without any compromise in distance visual performance between the two IOLs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Database systems have a user interface one of the components of which will normally be a query language which is based on a particular data model. Typically data models provide primitives to define, manipulate and query databases. Often these primitives are designed to form self-contained query languages. This thesis describes a prototype implementation of a system which allows users to specify queries against the database in a query language whose primitives are not those provided by the actual model on which the database system is based, but those provided by a different data model. The implementation chosen is the Functional Query Language Front End (FQLFE). This uses the Daplex functional data model and query language. Using FQLFE, users can specify the underlying database (based on the relational model) in terms of Daplex. Queries against this specified view can then be made in Daplex. FQLFE transforms these queries into the query language (Quel) of the underlying target database system (Ingres). The automation of part of the Daplex function definition phase is also described and its implementation discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In recent years, UK industry has seen an explosive growth in the number of `Computer Aided Production Management' (CAPM) system installations. Of the many CAPM systems, materials requirement planning/manufacturing resource planning (MRP/MRPII) is the most widely implemented. Despite the huge investments in MRP systems, over 80 percent are said to have failed within 3 to 5 years of installation. Many people now assume that Just-In-Time (JIT) is the best manufacturing technique. However, those who have implemented JIT have found that it also has many problems. The author argues that the success of a manufacturing company will not be due to a system which complies with a single technique; but due to the integration of many techniques and the ability to make them complement each other in a specific manufacturing environment. This dissertation examines the potential for integrating MRP with JIT and Two-Bin systems to reduce operational costs involved in managing bought-out inventory. Within this framework it shows that controlling MRP is essential to facilitate the integrating process. The behaviour of MRP systems is dependent on the complex interactions between the numerous control parameters used. Methodologies/models are developed to set these parameters. The models are based on the Pareto principle. The idea is to use business targets to set a coherent set of parameters, which not only enables those business targets to be realised, but also facilitates JIT implementation. It illustrates this approach in the context of an actual manufacturing plant - IBM Havant. (IBM Havant is a high volume electronics assembly plant with the majority of the materials bought-out). The parameter setting models are applicable to control bought-out items in a wide range of industries and are not dependent on specific MRP software. The models have produced successful results in several companies and are now being developed as commercial products.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The work reported in this thesis is concerned with the improvement and expansion of the assistance given to the designer by the computer in the design of cold formed sections. The main contributions have been in four areas, which have consequently led to the fifth, the development of a methodology to optimise designs. This methodology can be considered an `Expert Design System' for cold formed sections. A different method of determining section properties of profiles was introduced, using the properties of line and circular elements. Graphics were introduced to show the outline of the profile on screen. The analysis of beam loading has been expanded to beam loading conditions where the number of supports, point loads, and uniform distributive loads can be specified by the designer. The profile can then be checked for suitability for the specified type of loading. Artificial Intelligence concepts have been introduced to give the designer decision support from the computer, in combination with the computer aided design facilities. The more complex decision support was adopted through the use of production rules. All the support was based on the British standards. A method has been introduced, by which the appropriate use of stiffeners can be determined and consequently designed by the designer. Finally, the methodology by which the designer is given assistance from the computer, without constraining the designer, was developed. This methodology gives advice to the designer on possible methods of improving the design, but allows the designer to reject that option, and analyse the profile accordingly. The methodology enables optimisation to be achieved by the designer, designing variety of profiles for a particular loading, and determining which one is best suited.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

It is advantageous to develop controlled release dosage forms utilising site-specific delivery or gastric retention for those drugs with frequent or high dosing regimes. Cimetidine is a potent and selective H2 -reception antagonist used in the treatment of various gastrointestinal disorders and localisation in the upper gastrointestinal tract could significantly improve the drug absorption. Three strategies were undertaken to prepare controlled release systems for the delivery of cimetidine to the GI tract. Firstly, increasing the contact time of the dosage form with the mucus layer which coats the gastrointestinal tract, may lead to increased gastric residence times. Mucoadhesive microspheres, by forming a gel-like structure in contact with the mucus, should prolong the contact between the delivery system and the mucus layer, and should have the potential for releasing the drug in sustained and controlled manner. Gelatin microspheres were prepared, optimised and characterised for their physicochemical properties. Crosslinking concentration, particle size and cimetidine loading influenced drug release profiles. Particle size was influenced by surfactant concentration and stirring speed. Mucoadheisve polymers such as alginates, chitosans, carbopols and polycarbophil were incorporated into the microspheres using different strategies. The mucoadhesion of the microspheres was determined using in vitro surface adsorption and ex vivo rat intestine models. The surface-modification strategy resulted in highest levels of microsphere adhesion, with chitosan, carbopols and polycarbophil as the most successful candidates for improvement of adhesion, with over 70% of the microspheres retained ex vivo. Specific targeting agent UEA I lectin was conjugated to the surface of gelatin microspheres, which enhanced the adhesion of the microspheres. Alginate raft systems containing antacids have been used extensively in the treatment of gastro-oesophageal disease and protection of the oesophageal mucosa from acid reflux by forming a viscous raft layer on the surface of the stomach content, and could be an effective delivery system for controlled release of cimetidine.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Aston Eye Study (AES) was instigated in October 2005 to determine the distribution of refractive error and associated ocular biometry in a sample of UK urban school children. The AES is the first study to compare outcome measures separately in White, South Asian and Black children. Children were selected from two age groups (Year 2 children aged 6/7 years, Year8 children aged 12/13 years of age) using random cluster sampling of schools in Birmingham, West Midlands UK. To date, the AES has examined 598 children (302 Year 2,296 Year 8). Using open-field cycloplegic autorefraction, the overall prevalence of myopia (=-0.50D SER in either eye) determined was 19.6%, with a higher prevalence in older (29.4%) compared to younger (9.9%) children (p<0.001). Using multiple logistic regression models, the risk of myopia was higher in Year 8 South Asian compared to White children and higher in children attending grammar schools relative to comprehensive schools. In addition, the prevalence of uncorrected ametropia was found to be high (Year 8: 12.84%, Year 2: 15.23%), which will be of concern to bodies responsible for the implementation of school vision screening strategies. Biometric data using non-contact partial coherence interferometry revealed a contributory effect of axial length (AL) and central corneal radius (CR) on myopic refraction, resulting in a strong coefficient of determination of the AL/CR ratio on refractive error. Ocular biometric measures did not vary significantly as a function of ethnicity, suggesting a greater miscorrelation of components in susceptible ethnic groups to account for their higher myopia prevalence. Corneal radius was found to be steeper in myopes in both age groups, but was found to flatten with increasing axial length. Due to the inextricable link between myopia and axial elongation, the paradoxical finding of the cornea demands further longitudinal investigation, particularly in relation to myopia onset. Questionnaire analysis revealed a history of myopia in parents and siblings to be significantly associated with myopia in Year 8 children, with a dose-dependent rise in the odds ratio of myopia evident with increasing number of myopic parents. By classifying socioeconomic status (SES) using Index of Multiple Deprivation values, it was found that Year 8 children from moderately deprived backgrounds were more at risk of myopia compared with children located at both extremities of the deprivation spectrum. However, the main effect of SES weakened following multivariate analysis, with South Asian ethnicity and grammar schooling remaining associated with Year 8 myopia after adjustment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aim: The aim of this study was to evaluate the practicality and accuracy of tonometers used in routine clinical practice for established keratoconus (KC). Methods: This was a prospective study of 118 normal and 76 keratoconic eyes where intraocular pressure (IOP) was measured in random order using the Goldman applanation tonometer (GAT), Pascal dynamic contour tonometer (DCT), Reichert ocular response analyser (ORA) and TonoPen XL tonometer. Corneal hysteresis (CH) and corneal resistance factor (CRF), as calculated by the ORA, were recorded. Central corneal thickness (CCT) was measured using an ultrasound pachymeter. Results: The difference in IOP values between instruments was highly significant in both study groups (p<0.001). All other IOP measures were significantly higher than those for GAT, except for the Goldmann-correlated IOP (average of the two applanation pressure points) (IOPg) as measured by ORA in the control group and the CH-corrected IOP (corneal-compensated IOP value) (IOPcc) measures in the KC group. CCT, CH and CRF were significantly less in the KC group (p<0.001). Apart from the DCT, all techniques tended to measure IOP higher in eyes with thicker corneas. Conclusion: The DCT and the ORA are currently the most appropriate tonometers to use in KC for the measurement of IOPcc. Corneal factors such as CH and CRT may be of more importance than CCT in causing inaccuracies in applanation tonometry techniques.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aims - Glycogen synthase kinase 3 (GSK-3) signalling is implicated in the growth of the heart during development and in response to stress. However, its precise role remains unclear. We set out to characterize developmental growth and response to chronic isoproterenol (ISO) stress in knockin (KI) mice lacking the critical N-terminal serines, 21 of GSK-3 and 9 of GSK-3 respectively, required for inactivation by upstream kinases. Methods and results - Between 5 and 15 weeks, KI mice grew more rapidly, but normalized heart weight and contractile performance were similar to wild-type (WT) mice. Isolated hearts of both genotypes responded comparably to acute ISO infusion with increases in heart rate and contractility. In WT mice, chronic subcutaneous ISO infusion over 14 days resulted in cardiac hypertrophy, interstitial fibrosis, and impaired contractility, accompanied by foetal gene reactivation. These effects were all significantly attenuated in KI mice. Indeed, ISO-treated KI hearts demonstrated reversible physiological remodelling traits with increased stroke volume and a preserved contractile response to acute adrenergic stimulation. Furthermore, simultaneous pharmacological inhibition of GSK-3 in KI mice treated with chronic subcutaneous ISO recapitulated the adverse remodelling phenotype seen in WT hearts. Conclusion - Expression of inactivation-resistant GSK-3/does not affect eutrophic myocardial growth but protects against pathological hypertrophy induced by chronic adrenergic stimulation, maintaining cardiac function and attenuating interstitial fibrosis. Accordingly, strategies to prevent phosphorylation of Ser-21/9, and consequent inactivation of GSK-3/, may enable a sustained cardiac response to chronic-agonist stimulation while preventing pathological remodelling. © 2010 The Author.