963 resultados para Measuring methods
Resumo:
Red blood cell (RBC) parameters such as morphology, volume, refractive index, and hemoglobin content are of great importance for diagnostic purposes. Existing approaches require complicated calibration procedures and robust cell perturbation. As a result, reference values for normal RBC differ depending on the method used. We present a way for measuring parameters of intact individual RBCs by using digital holographic microscopy (DHM), a new interferometric and label-free technique with nanometric axial sensitivity. The results are compared with values achieved by conventional techniques for RBC of the same donor and previously published figures. A DHM equipped with a laser diode (lambda = 663 nm) was used to record holograms in an off-axis geometry. Measurements of both RBC refractive indices and volumes were achieved via monitoring the quantitative phase map of RBC by means of a sequential perfusion of two isotonic solutions with different refractive indices obtained by the use of Nycodenz (decoupling procedure). Volume of RBCs labeled by membrane dye Dil was analyzed by confocal microscopy. The mean cell volume (MCV), red blood cell distribution width (RDW), and mean cell hemoglobin concentration (MCHC) were also measured with an impedance volume analyzer. DHM yielded RBC refractive index n = 1.418 +/- 0.012, volume 83 +/- 14 fl, MCH = 29.9 pg, and MCHC 362 +/- 40 g/l. Erythrocyte MCV, MCH, and MCHC achieved by an impedance volume analyzer were 82 fl, 28.6 pg, and 349 g/l, respectively. Confocal microscopy yielded 91 +/- 17 fl for RBC volume. In conclusion, DHM in combination with a decoupling procedure allows measuring noninvasively volume, refractive index, and hemoglobin content of single-living RBCs with a high accuracy.
Resumo:
The aim of this study is to perform a thorough comparison of quantitative susceptibility mapping (QSM) techniques and their dependence on the assumptions made. The compared methodologies were: two iterative single orientation methodologies minimizing the l2, l1TV norm of the prior knowledge of the edges of the object, one over-determined multiple orientation method (COSMOS) and anewly proposed modulated closed-form solution (MCF). The performance of these methods was compared using a numerical phantom and in-vivo high resolution (0.65mm isotropic) brain data acquired at 7T using a new coil combination method. For all QSM methods, the relevant regularization and prior-knowledge parameters were systematically changed in order to evaluate the optimal reconstruction in the presence and absence of a ground truth. Additionally, the QSM contrast was compared to conventional gradient recalled echo (GRE) magnitude and R2* maps obtained from the same dataset. The QSM reconstruction results of the single orientation methods show comparable performance. The MCF method has the highest correlation (corrMCF=0.95, r(2)MCF =0.97) with the state of the art method (COSMOS) with additional advantage of extreme fast computation time. The l-curve method gave the visually most satisfactory balance between reduction of streaking artifacts and over-regularization with the latter being overemphasized when the using the COSMOS susceptibility maps as ground-truth. R2* and susceptibility maps, when calculated from the same datasets, although based on distinct features of the data, have a comparable ability to distinguish deep gray matter structures.
Resumo:
Different embolic materials for portal vein embolization (PVE) were evaluated. Twenty pigs received left and median PVE. Hydrophilic phosphorylcholine, N-butyl cyanoacrylate, hydrophilic gel, and polyvinyl alcohol (PVA) particles measuring either 50-150 microm or 700-900 microm were used in five pigs each. Portography and portal vein pressure measurement were performed before, immediately after PVE, and before being euthanized at day 7. Tissue wedges from embolized, and non-embolized liver were obtained for pathology. After complete embolization, recanalization occurred at 7 days in one gel and one 700-900 PVA embolization. Post-PVE increase in portal pressure was found in all groups (p = 0.01). The area of the hepatic lobules in non-embolized liver was larger than in the embolized liver in all groups (p = 0.001). The ratios of the areas between non-embolized/embolized livers were 1.65, 2.19, 1.57, and 1.32 for gel, NBCA, 50-150 PVA and 700-900 PVA, respectively; the ratios of fibrosis between the embolized and non-embolized livers were 1.37, 3.01, 3.49, and 2.11 for gel, NBCA, 50-150 PVA and 700-900 PVA, respectively. Hepatic lobules in non-embolized liver were significantly larger with NBCA than in other groups (p = 0.01). Fibrosis in embolized liver was significantly higher for NBCA and 50-150 PVA (p = 0.002). The most severe changes in embolized and non-embolized liver were induced by 50-150 PVA and NCBA PVE.
Quantitative comparison of reconstruction methods for intra-voxel fiber recovery from diffusion MRI.
Resumo:
Validation is arguably the bottleneck in the diffusion magnetic resonance imaging (MRI) community. This paper evaluates and compares 20 algorithms for recovering the local intra-voxel fiber structure from diffusion MRI data and is based on the results of the "HARDI reconstruction challenge" organized in the context of the "ISBI 2012" conference. Evaluated methods encompass a mixture of classical techniques well known in the literature such as diffusion tensor, Q-Ball and diffusion spectrum imaging, algorithms inspired by the recent theory of compressed sensing and also brand new approaches proposed for the first time at this contest. To quantitatively compare the methods under controlled conditions, two datasets with known ground-truth were synthetically generated and two main criteria were used to evaluate the quality of the reconstructions in every voxel: correct assessment of the number of fiber populations and angular accuracy in their orientation. This comparative study investigates the behavior of every algorithm with varying experimental conditions and highlights strengths and weaknesses of each approach. This information can be useful not only for enhancing current algorithms and develop the next generation of reconstruction methods, but also to assist physicians in the choice of the most adequate technique for their studies.
Resumo:
The diagnosis of tick-borne diseases such as babesiosis still depends on observing the parasite in the infected erythrocyte. Microscopic observation is tedious and often problematic in both early and carrier infections. Better diagnostic methods are needed to prevent clinical disease, especially when susceptible cattle are being moved into disease enzootic areas. This study evaluates two techniques for early diagnosis of Babesia bovis infections in cattle, DNA probes specific for the organism and fluorescent probes specific nucleic acid. The radioisotopically labeled DNA probes are used in slot blot hybridizations whith lysed blood samples, not purified DNA. Thusfar, the probe is specific for B. bovis and can detect as few as 1000 B. bovis parasites in 10µl of blood. The specificity of the fluorescent probe depends on the characteristic morphology of the babesia in whole blood samples, as determined microscopically. The fluorescent probe detects as afew as 10,000 B. bovis parasites in 10*l as blood. The application of each method for alboratory and field use is discussed.
Resumo:
Accurate diagnosis of Babesia bigemina infection, an economically important tick-transmitted protozoan parasite of cattle, is essential in the management of disease control and in epidemiological studies. The currentlyused methods of diagnosis are blood smear examination and serological tests which include agglutination and immunofluorescence tests. These testes have been used the fild but because they lack sensitivity and specificity, never and improved methods of diagnosis are being developed. The quantitative buffy coat (OBC) method, using microhaematocrit tubes and acridine orange staining allows rapid and quicker diagnosis of B. bigemina and other blood parasites compared to light microscopic examination of stained smears. Parasite specific monoclonal antibodies have been used in antigen/antibody capture enzymelinked immunosorbent assays with grater sensitivity and specificity than previously described serological tests. Similary, DNA probes, derived from a repetitive sequence of the B. bigemina genome, offer a method of detecting very small numbers of parasites which are undetectable by conventional microscopy. An extrachromosomal DNA element, present in all the tick-borne protozoan parasites so far tested, provides an accurate means of diferentiating mixed parasite populations in infected animals. These improved methods will greatly facilitate epidemiological studies.
Resumo:
We construct a new family of semi-discrete numerical schemes for the approximation of the one-dimensional periodic Vlasov-Poisson system. The methods are based on the coupling of discontinuous Galerkin approximation to the Vlasov equation and several finite element (conforming, non-conforming and mixed) approximations for the Poisson problem. We show optimal error estimates for the all proposed methods in the case of smooth compactly supported initial data. The issue of energy conservation is also analyzed for some of the methods.
Resumo:
Quality control in health care should be performed by health professionals. To do so they must define indicators, set up studies aimed at measuring and analyzing quality of care, and implement quality assurance programs in health care systems. The elements of a quality improvement program of this kind are described, with special emphasis on the contribution of epidemiology in this field.
Resumo:
When using a polynomial approximating function the most contentious aspect of the Heat Balance Integral Method is the choice of power of the highest order term. In this paper we employ a method recently developed for thermal problems, where the exponent is determined during the solution process, to analyse Stefan problems. This is achieved by minimising an error function. The solution requires no knowledge of an exact solution and generally produces significantly better results than all previous HBI models. The method is illustrated by first applying it to standard thermal problems. A Stefan problem with an analytical solution is then discussed and results compared to the approximate solution. An ablation problem is also analysed and results compared against a numerical solution. In both examples the agreement is excellent. A Stefan problem where the boundary temperature increases exponentially is analysed. This highlights the difficulties that can be encountered with a time dependent boundary condition. Finally, melting with a time-dependent flux is briefly analysed without applying analytical or numerical results to assess the accuracy.
Resumo:
BACKGROUND: As the diversity of the European population evolves, measuring providers' skillfulness in cross-cultural care and understanding what contextual factors may influence this is increasingly necessary. Given limited information about differences in cultural competency by provider role, we compared cross-cultural skillfulness between physicians and nurses working at a Swiss university hospital. METHODS: A survey on cross-cultural care was mailed in November 2010 to front-line providers in Lausanne, Switzerland. This questionnaire included some questions from the previously validated Cross-Cultural Care Survey. We compared physicians' and nurses' mean composite scores and proportion of "3-good/4-very good" responses, for nine perceived skillfulness items (4-point Likert-scale) using the validated tool. We used linear regression to examine how provider role (physician vs. nurse) was associated with composite skillfulness scores, adjusting for demographics (gender, non-French dominant language), workplace (time at institution, work-unit "sensitized" to cultural-care), reported cultural-competence training, and cross-cultural care problem-awareness. RESULTS: Of 885 questionnaires, 368 (41.2%) returned the survey: 124 (33.6%) physicians and 244 (66.4%) nurses, reflecting institutional distribution of providers. Physicians had better mean composite scores for perceived skillfulness than nurses (2.7 vs. 2.5, p < 0.005), and significantly higher proportion of "good/very good" responses for 4/9 items. After adjusting for explanatory variables, physicians remained more likely to have higher skillfulness (β = 0.13, p = 0.05). Among all, higher skillfulness was associated with perception/awareness of problems in the following areas: inadequate cross-cultural training (β = 0.14, p = 0.01) and lack of practical experience caring for diverse populations (β = 0.11, p = 0.04). In stratified analyses among physicians alone, having French as a dominant language (β = -0.34, p < 0.005) was negatively correlated with skillfulness. CONCLUSIONS: Overall, there is much room for cultural competency improvement among providers. These results support the need for cross-cultural skills training with an inter-professional focus on nurses, education that attunes provider awareness to the local issues in cross-cultural care, and increased diversity efforts in the work force, particularly among physicians.
Resumo:
OBJECTIVE: To reach a consensus on the clinical use of ambulatory blood pressure monitoring (ABPM). METHODS: A task force on the clinical use of ABPM wrote this overview in preparation for the Seventh International Consensus Conference (23-25 September 1999, Leuven, Belgium). This article was amended to account for opinions aired at the conference and to reflect the common ground reached in the discussions. POINTS OF CONSENSUS: The Riva Rocci/Korotkoff technique, although it is prone to error, is easy and cheap to perform and remains worldwide the standard procedure for measuring blood pressure. ABPM should be performed only with properly validated devices as an accessory to conventional measurement of blood pressure. Ambulatory recording of blood pressure requires considerable investment in equipment and training and its use for screening purposes cannot be recommended. ABPM is most useful for identifying patients with white-coat hypertension (WCH), also known as isolated clinic hypertension, which is arbitrarily defined as a clinic blood pressure of more than 140 mmHg systolic or 90 mmHg diastolic in a patient with daytime ambulatory blood pressure below 135 mmHg systolic and 85 mmHg diastolic. Some experts consider a daytime blood pressure below 130 mmHg systolic and 80 mmHg diastolic optimal. Whether WCH predisposes subjects to sustained hypertension remains debated. However, outcome is better correlated to the ambulatory blood pressure than it is to the conventional blood pressure. Antihypertensive drugs lower the clinic blood pressure in patients with WCH but not the ambulatory blood pressure, and also do not improve prognosis. Nevertheless, WCH should not be left unattended. If no previous cardiovascular complications are present, treatment could be limited to follow-up and hygienic measures, which should also account for risk factors other than hypertension. ABPM is superior to conventional measurement of blood pressure not only for selecting patients for antihypertensive drug treatment but also for assessing the effects both of non-pharmacological and of pharmacological therapy. The ambulatory blood pressure should be reduced by treatment to below the thresholds applied for diagnosing sustained hypertension. ABPM makes the diagnosis and treatment of nocturnal hypertension possible and is especially indicated for patients with borderline hypertension, the elderly, pregnant women, patients with treatment-resistant hypertension and patients with symptoms suggestive of hypotension. In centres with sufficient financial resources, ABPM could become part of the routine assessment of patients with clinic hypertension. For patients with WCH, it should be repeated at annual or 6-monthly intervals. Variation of blood pressure throughout the day can be monitored only by ABPM, but several advantages of the latter technique can also be obtained by self-measurement of blood pressure, a less expensive method that is probably better suited to primary practice and use in developing countries. CONCLUSIONS: ABPM or equivalent methods for tracing the white-coat effect should become part of the routine diagnostic and therapeutic procedures applied to treated and untreated patients with elevated clinic blood pressures. Results of long-term outcome trials should better establish the advantage of further integrating ABPM as an accessory to conventional sphygmomanometry into the routine care of hypertensive patients and should provide more definite information on the long-term cost-effectiveness. Because such trials are not likely to be funded by the pharmaceutical industry, governments and health insurance companies should take responsibility in this regard.