970 resultados para Measurement by laser beam


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A microchannel was inscribed in the fiber of a ring cavity which was constructed using two 0.1%:99.9% couplers and a 10-m fiber loop. Cavity ring down spectroscopy was used to measure the refractive index (RI) of gels infused into the microchannel. The ring down time discloses a nonlinear increase with respect to RI of the gel and sensitivity up to 300 µs/RI unit and an index resolution of 1.4 × 10 was obtained. © 2009 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A microchannel was inscribed in the fiber of a ring cavity which was constructed using two 0.1%:99.9% couplers and a 10-m fiber loop. Cavity ring down spectroscopy was used to measure the refractive index (RI) of gels infused into the microchannel. The ring down time discloses a nonlinear increase with respect to RI of the gel and sensitivity up to 300 µs/RI unit and an index resolution of 1.4 × 10 was obtained. © 2009 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Laser trackers have been widely used in many industries to meet increasingly high accuracy requirements. In laser tracker measurement, it is complex and difficult to perform an accurate error analysis and uncertainty evaluation. This paper firstly reviews the working principle of single beam laser trackers and state-of- The- Art of key technologies from both industrial and academic efforts, followed by a comprehensive analysis of uncertainty sources. A generic laser tracker modelling method is formulated and the framework of the virtual tracker is proposed. The VLS can be used for measurement planning, measurement accuracy optimization and uncertainty evaluation. The completed virtual laser tracking system should take all the uncertainty sources affecting coordinate measurement into consideration and establish an uncertainty model which will behave in an identical way to the real system. © Springer-Verlag Berlin Heidelberg 2010.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Measurements of neutrino oscillations using the disappearance of muon neutrinos from the Fermilab NuMI neutrino beam as observed by the two MINOS detectors are reported. New analysis methods have been applied to an enlarged data sample from an exposure of 7.25 x 10(20) protons on target. A fit to neutrino oscillations yields values of vertical bar Delta m(2)vertical bar = (2.32(-0.08)(+0.12) x 10(-3) eV(2) for the atmospheric mass splitting and sin(2)(2 theta) > 0.90 (90% C.L.) for the mixing angle. Pure neutrino decay and quantum decoherence hypotheses are excluded at 7 and 9 standard deviations, respectively.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Dissertation to obtain a Master degree in Biotechnology

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Long-range Terrestrial Laser Scanning (TLS) is widely used in studies on rock slope instabilities. TLS point clouds allow the creation of high-resolution digital elevation models for detailed mapping of landslide morphologies and the measurement of the orientation of main discontinuities. Multi-temporal TLS datasets enable the quantification of slope displacements and rockfall volumes. We present three case studies using TLS for the investigation and monitoring of rock slope instabilities in Norway: 1) the analysis of 3D displacement of the Oksfjellet rock slope failure (Troms, northern Norway); 2) the detection and quantification of rockfalls along the sliding surfaces and at the front of the Kvitfjellet rock slope instability (Møre og Romsdal, western Norway); 3) the analysis of discontinuities and rotational movements of an unstable block at Stampa (Sogn og Fjordane, western Norway). These case studies highlight the possibilities but also limitations of TLS in investigating and monitoring unstable rock slopes.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

SrMg^Rui-iOa thin films were made by using pulsed laser deposition on SrTiOa (100) substrates in either O2 or Ar atmosphere. The thin films were characterized by x-ray diffraction, energy dispersive x-ray microanalysis, dc resistivity measurement, and dc magnetization measurement. The effect of Mg doping was observed. As soon as the amount of Mg increased in SrMg-cRui-iOa thin films, the magnetization decreased, and the resistivity increased. It had little effect on the Curie temperature (transition temperature). The magnetization states of SrMgiRui-iOa thin films, for x < 0.15, are similar to SrRuOs films. X-ray diffraction results for SrMga-Rui-iOa thin films made in oxygen showed that the films are epitaxial. The thin films could not be well made in Ar atmosphere during laser ablation as there was no clear peak of SrMg^Rui-iOa in x-ray diffraction results. Substrate temperatures had an effect on the resistivity of the films. The residual resistivity ratios were increased by increasing substrate temperature. It was observed that the thickness of thin films are another factor for film quality: Thin films were epitaxial, but thicker films were not epitaxial.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In this paper, we report the in-plane and cross-plane measurements of the thermal diffusivity of double epitaxial layers of n-type GaAs doped with various concentrations of Si and a p-type Be-doped GaAs layer grown on a GaAs substrate by the molecular beam epitaxial method, using the laser-induced nondestructive photothermal deflection technique. The thermal diffusivity value is evaluated from the slope of the graph of the phase of the photothermal deflection signal as a function of pump-probe offset. Analysis of the data shows that the cross-plane thermal diffusivity is less than that of the in-plane thermal diffusivity. It is also seen that the doping concentration has a great influence on the thermal diffusivity value. Measurement of p-type Be-doped samples shows that the nature of the dopant also influences the effective thermal diffusivity value. The results are interpreted in terms of a phonon-assisted heat transfer mechanism and the various scattering process involved in the propagation of phonons.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In this paper, we report the in-plane and cross-plane measurements of the thermal diffusivity of double epitaxial layers of n-type GaAs doped with various concentrations of Si and a p-type Be-doped GaAs layer grown on a GaAs substrate by the molecular beam epitaxial method, using the laser-induced nondestructive photothermal deflection technique. The thermal diffusivity value is evaluated from the slope of the graph of the phase of the photothermal deflection signal as a function of pump-probe offset. Analysis of the data shows that the cross-plane thermal diffusivity is less than that of the in-plane thermal diffusivity. It is also seen that the doping concentration has a great influence on the thermal diffusivity value. Measurement of p-type Be-doped samples shows that the nature of the dopant also influences the effective thermal diffusivity value. The results are interpreted in terms of a phonon-assisted heat transfer mechanism and the various scattering process involved in the propagation of phonons

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In this paper, we report the in-plane and cross-plane measurements of the thermal diffusivity of double epitaxial layers of n-type GaAs doped with various concentrations of Si and a p-type Be-doped GaAs layer grown on a GaAs substrate by the molecular beam epitaxial method, using the laser-induced nondestructive photothermal deflection technique. The thermal diffusivity value is evaluated from the slope of the graph of the phase of the photothermal deflection signal as a function of pump-probe offset. Analysis of the data shows that the cross-plane thermal diffusivity is less than that of the in-plane thermal diffusivity. It is also seen that the doping concentration has a great influence on the thermal diffusivity value. Measurement of p-type Be-doped samples shows that the nature of the dopant also influences the effective thermal diffusivity value. The results are interpreted in terms of a phonon-assisted heat transfer mechanism and the various scattering process involved in the propagation of phonons

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The dual-beam thermal lens technique has been found to be very effective for the measurement of fluorescence quantum yields of dye solutions. The concentration-dependence of the quantum yield of rhodamine B in methanol is studied here using this technique. The observed results are in line with the conclusion that the reduction in the quantum yield in the quenching region is essentially due to the non-radiative relaxation of the absorbed energy. The thermal lens has been found to become abberated above 40 mW of pump laser power. This low value for the upper limit of pump power is due to the fact that the medium is a resonantly absorbing one.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

We demonstrate the possibility of realizing, all-optical switching in gold nanosol. Two overlapping laser beams are used for this purpose, due to which a low-power beam passing collinear to a high-power beam will undergo cross phase modulation and thereby distort the spatial profile. This is taken to advantage for performing logic operations. We have also measured the threshold pump power to obtain a NOT gate and the minimum response time of the device. Contrary to the general notion that the response time of thermal effects used in this application is of the order of milliseconds, we prove that short pump pulses can result in fast switching. Different combinations of beam splitters and combiners will lead to the formation of other logic functions too.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

*** Purpose – Computer tomography (CT) for 3D reconstruction entails a huge number of coplanar fan-beam projections for each of a large number of 2D slice images, and excessive radiation intensities and dosages. For some applications its rate of throughput is also inadequate. A technique for overcoming these limitations is outlined. *** Design methodology/approach – A novel method to reconstruct 3D surface models of objects is presented, using, typically, ten, 2D projective images. These images are generated by relative motion between this set of objects and a set of ten fanbeam X-ray sources and sensors, with their viewing axes suitably distributed in 2D angular space. *** Findings – The method entails a radiation dosage several orders of magnitude lower than CT, and requires far less computational power. Experimental results are given to illustrate the capability of the technique *** Practical implications – The substantially lower cost of the method and, more particularly, its dramatically lower irradiation make it relevant to many applications precluded by current techniques *** Originality/value – The method can be used in many applications such as aircraft hold-luggage screening, 3D industrial modelling and measurement, and it should also have important applications to medical diagnosis and surgery.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In this work we have studied pure and thulium- and chromium-doped ZBLAN glasses irradiated by ultra-short laser pulses. A Ti:sapphire CPA system was used, producing a 500 Hz train of pulses, centered at 830 nm, with 375 mu J of energy and 50 fs of duration (FWHM). The beam was focused by a 20 Him lens, producing a converging beam with a waist of 12 pin. The absorption spectra before and after laser irradiation were obtained showing production of color centers in pure, thulium-doped and chromium-doped ZBLAN glasses. A damage threshold of 9.56 TW/cm(2) was determined for ZBLAN. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

We investigated the IR absorption spectrum of 13CH3OH around the frequency of the 10R(20) CO2 laser line. We found two absorption lines which can be excited by 10R(20) and studied the FIR laser emissions excited by this pump line using a waveguide CO2 laser of 300 MHz tunability. We report two new FIR laser lines of large offset, not previously observed due to their weakness and closeness to other stronger lines. We measured the frequencies of five FIR laser lines for the first time by an accurate heterodyne technique and present the complete assignments of the IR-FIR laser systems relative to this pump line. Furthermore we present new frequency values for two FIR laser lines whose frequencies had been previously wrongly measured. Copyright © 1997 Elsevier Science Ltd.