940 resultados para Magnetic Resonance (mr)


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Magnetic Resonance Imaging (MRI) is one of the prominent medical imaging techniques. This process is time-consuming and can take several minutes to acquire one image. The aim of this research is to reduce the imaging process time of MRI. This issue is addressed by reducing the number of acquired measurements using theory of Compressive Sensing (CS). Compressive Sensing exploits sparsity in MR images. Randomly under sampled k-space generates incoherent noise which can be handled using a nonlinear image reconstruction method. In this paper, a new framework is presented based on the idea to exploit non-uniform nature of sparsity in MR images, where local sparsity constrains were used instead of traditional global constraint, to further reduce the sample set. Experimental results and comparison with CS using global constraint are demonstrated.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Magnetic Resonance Imaging (MRI) is an important imaging technique. However, it is a time consuming process. The aim of this study is to make the imaging process ef?cient. MR images are sparse in the sensing domain and Compressive Sensing exploits this sparsity. Locally sparsi?ed Compressed Sensing is a specialized case of CS which sub-divides the image and sparsi?es each region separately; later samples are taken based on sparsity level in that region. In this paper, a new structured approach is presented for de?ning the size and locality of sub-regions in image. Experiments were done on the regions de?ned by proposed framework and local sparsity constraints were used to achieve high sparsity level and to reduce the sample set. Experimental results and their comparison with global CS is presented in the paper.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Cognitive symptoms and impairment are central to schizophrenia and often an early sign of this condition. The present study investigated biological correlates of cognitive symptoms and performance in individuals at ultra-high risk (UHR) for psychosis. The study sample comprised 80 neuroleptic-naïve UHR individuals aged 13-25 years. Associations among erythrocyte membrane fatty acid levels, measured by gas chromatography, and cognitive functioning were investigated in UHR patients. Subjects were divided into terciles based on their scores on the cognitive factor of the Positive and Negative Syndrome Scale. The Zahlen-Verbindungs Test (ZVT) (the number-combination test) was also used as a measure of information-processing speed. Exploratory analysis was conducted to investigate the relationship between membrane fatty acid levels with the size of the intracranial area (ICA), a neurodevelopmental measure relevant to schizophrenia, in half of subjects (n=40) using magnetic resonance imaging. The adjusted analysis revealed that omega-9 eicosenoic and erucic acid levels were significantly higher, but omega-3 docosahexaenoic acid levels were significantly lower, in the cognitively impaired than in the cognitively intact group. We found a significant negative association of eicosenoic, erucic, and gamma-linoleic acids with ZVT scores. A negative association between ICA and membrane levels of eicosenoic acid was also found. This is the first study to demonstrate the relationship between membrane fatty acids and cognitive function in neuroleptic-naïve subjects at UHR for psychosis. The study findings indicate that abnormalities in membrane fatty acids may be associated with the neurodevelopmental disruption associated with the cognitive impairments of individuals at UHR for psychosis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Magnetic Resonance images (MRI) do not only exhibit sparsity but their sparsity take a certain predictable shape which is common for all kinds of images. That region based localised sparsity can be used to de-noise MR images from random thermal noise. This paper present a simple framework to exploit sparsity of MR images for image de-noising. As, noise in MR images tends to change its shape based on contrast level and signal itself, the proposed method is independent of noise shape and type and it can be used in combination with other methods.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fat accumulates in the bone marrow of lumbar vertebrae with bed rest. Exercise with or without whole body vibration may counter this effect. Our objectives were to measure 1) the vertebral fat fraction (VFF) of men subjected to bed rest who performed resistive exercises with (RVE, n = 7) or without whole body vibration(RE, n = 8) or no exercise (CTR, n = 9) using three MRI techniques; and 2) changes in peripheral blood counts. Twenty-four healthy men (age: 20-45 yr) underwent -6° head-down tilt (HDT) bed rest for 60 days. MRI was performed using three techniques (fat saturation, proton spectroscopy, and in and out of phase) to measure the fat fraction of L(3), L(4), and/or L(5) at baseline, mid-HDT, and end-HDT. Erythrocytes and leukocytes were counted at HDT days 19, 33, 47, 54, and 60. The mean absolute VFF was increased in the CTR group at mid-HDT and end-HDT (+3.9 ± 1.3 and +3.6 ± 1.2%, respectively, both P < 0.05). The RE group had a smaller VFF change than the CTR group at mid-HDT (-0.9 ± 1.2 vs. +3.9 ± 1.3%, P < 0.05). The RVE group had a smaller VFF change than the CTR group at end-HDT (-2.6 ± 1.9 vs. +3.5 ± 1.2%, P < 0.05). Erythrocyte counts were increased in all groups at HDT day 19 and HDT day 33 and in the RE group at HDT day 54 (all P < 0.05). Bed rest for 60 days at -6° HDT increased lumbar VFF in men beyond natural involution. RVE and RE regimens effectively prevented VFF accumulation. Higher erythrocyte counts were not altered by RVE or RE. Whole body vibration, along with RE administered to people with prolonged immobility, may prevent fat accumulation in their bone marrow.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

There is substantial controversy in literature about human dermatomes. In this work, C5 and C6 superior limb dermatomes were studied. The method consisted of comparing clinical signs and symptoms with conduction studies, electromyographical data, neurosurgical findings, and imaging findings obtained by computerized tomography (CT) or magnetic resonance imaging (MRI), for each patient. Data analysis from superior members in 18 patients suggests that C5 is located in the lateral aspect of the shoulder and arm, and C6 in the lateral aspect of the forearm and 1(st), 2(nd), and 3(rd) fingers. To our knowledge this is the first time that C5 and C6 human dermatomes have been studied by all the following methods together: clinical, electromyographical, CT and MR imaging, and surgical findings.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Gigahertz conductivity of pressed pellets of ClO4--doped poly( 3-methylthiophene) can be readily obtained from the asymmetry ratio (A / B) of the electron spin resonance line using Dyson's theory. The measurements were performed in three different frequencies, 1.3, 9.4, and 35 GHz. The temperature dependence of the gigahertz conductivity is sensitive to the heating rate, probably due to the ordering of the randomly assembled anions. (C) 1994 Academic Press, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Some synthetic metals show in addition to good conductivity, high microwave dielectric constants. In this work, it is shown how conduction-electron spin resonance(CESR) lineshape can be affected by these high constants. The conditions for avoiding these effects in the CESR measurements are discussed as well as a method for extracting microwave dielectric constants from CESR lines. (C) 1995 Academic Press, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Dysonian line in the limit d < or ∼ δ, where d is the thickness and 6 the skin depth, was fitted to a combination of absorption and dispersion Lorentzian lines. This procedure allows one to determine not only microwave conductivity from the Dysonian line but also the true g value, linewidth, and paramagnetic susceptibility by the measurement of five parameters of the ESR absorption-derivative Dysonian line. ©1990 Academic Press, inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Measurements of 1H Nuclear Magnetic Resonance (NMR) relaxation times, Electron Paramagnetic Resonance (EPR) and AC Impedance Spectroscopy (IS) are reported for composites based on PEO8:LiClO4 and carbon black (CB), prepared by two methods: solvent and fusion processing. Three nuclear relaxation processes were identified for 1H nuclei: (i) belonging to the polymer chains in the amorphous phase, loosely bound to the CB particles, whose dynamics is almost the same as for unfilled polymer, (ii) belonging to the polymer chains which are tightly attached to the CB particles, and (iii) belonging to the crystalline phase in the loose polymer chain. The paramagnetic electronic susceptibility of the composite samples, measured by EPR, was interpreted by assuming a contribution of localized spin states that follow a Curie law, and a Pauli-like contribution of delocalized spins. A significant change of the EPR linewidth was observed at 40 K, which is the temperature where the Curie and Pauli susceptibilities equally contribute to the paramagnetic electronic susceptibility. The electrical properties are very sensitive to the preparation methods of the composites, which conditions the interaction between carbon particle-carbon particle and carbon particle-polymer chain. Classical statistic models to describe the conductivity in these media were not satisfactory. © 1998 Published by Elsevier Science B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Ultrasonography (US), Computed Tomography (CT), and Magnetic Resonance imaging (MR) were compared for the staging of renal tumors. The differences between these imaging techniques were also studied for their ability to detect adenopathies, vascular invasion, distant intra-abdominal metastases, and particularly adjacent organ invasion. METHODS: Thirty-one patients with solid or complex renal masses were prospectively studied using US, CT, and MR. Differences between the results obtained were studied using the COCHRAN G test and the McNEMAR test. The sensitivity and specificity of each diagnostic technique were compared against a gold standard of the surgical and histopathological findings. RESULTS: The following sensitivities were obtained: For the detection of adenopathy, US 63.6%, CT and MR 90.9%. For vascular invasion, US 42.8%, CT and MR 85.7%. For the adjacent organ invasion, US 28.5%, CT 85.7%, and MR 71.4%. Some of the criteria that suggest invasion of adjacent structures include: the envelopment of the adjacent structures by the tumor, tumor extension into the adjacent structures with an irregular appearance, and alterations in shape, size, and density of adjacent structures. Loss of fat planes between the tumor and adjacent structures is not a sign of tumor invasion. CONCLUSIONS: Significant differences were found in the detection capacity of US in relation to CT and MR, which were similar. All three techniques were highly sensitive and specific only in the detection of distant abdominal metastases. In addition to the accuracy of these diagnostic modalities for the detection and staging of tumors, invasiveness, risks and cost should be considered in relation to relative costs and benefits.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Apert Syndrome, also called acrocephalosyndactylia type 1, is characterized by craniostenosis with early fusion of sutures of the vault and/ or cranial base, associated to mid-face hypoplasia, symmetric syndactylia of the hands and feet and other systemic malformations. CNS malformations and intracranial hypertension are frequently observed in these patients. Early surgical treatment aims to minimize the deleterious effects of intracranial hypertension. Fronto-orbital advancement, the usual surgical technique, increases the intracranial volume and improves the disposition of encephalic structures previously deformed by a short skull. This study analyzes CNS alterations revealed by magnetic resonance in 18 patients presenting Apert Syndrome, and the conformational alterations in the encephalic structures after surgical treatment. The patients' age in February 2001 ranged from 14 to 322 months (m=107). Image study included brain magnetic resonance showing ventricular enlargement in five cases (27.8%), corpus callosum hypoplasia in five cases (27.8%), septum pellucidum hypoplasia in five cases (27.8%), cavum vergae in two cases (11.1%) and, arachnoid cyst in the posterior fossa in two cases (11.1%). Absence of CNS alterations was noted in 44.4% of cases. A corpus callosum morphologic index was established by dividing its height by its length, which revealed values that ranged from 0.4409 to 1.0237. The values of this index were correlated to the occurrence or absence of surgical treatment (p=0.012; t=2.83). Data analysis allowed the conclusion that the corpus callosum morphologic measure quantified the conformational alterations of the cerebral structures determined by the surgical treatment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The use of multimodal neuroimaging techniques has been helpful in the investigation of epileptogenic zone in patients with refractory epilepsies. This work aims to describe an ictal event during EEG-fMRI performed simultaneously in a 39-year-old man with refractory epilepsy. The EEG data were recorded at a sampling rate of 5 kHz, using a BrainAmp (BrainProducts, München, Germany) amplifier, with 64 MR (magnetic resonance) compatible Ag/AgCl electrodes. MR images were acquired using a 3T scanner in 3 sequences of 6 minutes of echo-planar images (EPIs), with TR = 2s, being the last sequence stopped after the ictal event. The EEG was corrected for gradient and pulse artifacts using the Brain Vision Analyzer2 software (BrainProducts), and the functional images were realigned, slice-timing corrected, normalized and smoothed. The start of the ictal changes was used for the evaluation of the BOLD response in MR images, using a t-test with a minimum cluster of 5 voxels, p <0.005 (T>2.5). The patient had a partial complex seizure, as noted by neurologist. The fMRI data showed positive BOLD responses (activation) in dysplastic areas, but showed the most significant activation outside the lesion, in areas compatible with secondary spread of the epileptic focus, probably caused by motor reaction also observed during the seizure. As a conclusion, we note that the technique of EEG-fMRI can detect the epileptogenic zone in patients with refractory epilepsy, but areas of dissemination of primary epileptogenic focus may show significant activation, introducing additional difficulties to the interpretation of the results

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A renormalization-group calculation of the temperature-dependent nuclear spin relaxation rate for a magnetic impurity in a metallic host is reported. The calculation follows a simplified procedure, which produces accurate rates in the low-temperature Fermi-liquid regime, although yielding only qualitatively reliable results at higher temperatures. In all cases considered, as the temperature T diminishes, the rates peak before decaying linearly to zero in the Fermi-liquid range. For T → 0, the results agree very well with Shiba's expression relating the low-temperature coefficient of the relaxation rate to the squared zero-temperature susceptibility. In the Kondo limit, the enhanced susceptibility associated with the Kondo resonance produces a very sharp peak in the relaxation rate near the Kondo temperature. © 1991.