1000 resultados para Métodos das ondas de tensão


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this review recent methods developed and applied to solve criminal occurences related to documentoscopy, ballistic and drugs of abuse are discussed. In documentoscopy, aging of ink writings, the sequence of line crossings and counterfeiting of documents are aspects to be solved with reproducible, fast and non-destructive methods. In ballistic, the industries are currently producing ''lead-free'' or ''nontoxic'' handgun ammunitions, so new methods of gunshot residues characterization are being presented. For drugs analysis, easy ambient sonic-spray ionization mass spectrometry (EASI-MS) is shown to provide a relatively simple and selective screening tool to distinguish m-CPP and amphetamines (MDMA) tablets, cocaine and LSD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid lipid nanoparticles have been extensively investigated as drug delivery systems. These colloidal systems have major advantages compared to others more traditional. Reported advantages include sustained release, ability to solubilize lipophilic drugs, increased physical and chemical stability of labile molecules, decreased unwanted side-effects showing lower toxicity, and scale up facilities. This paper aims at reviewing the traditional methods of solid lipid nanoparticles production, such as fusion-emulsification (hot and cold), solvent evaporation-emulsification and microemulsion, dealing with the main technological parameters that influence the quality properties of solid lipid nanoparticles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work applied a 2² factorial design to the optimization of the extraction of seven elements (calcium, magnesium, potassium, iron, zinc, copper and manganese) in brachiaria leaves, determined by flame atomic absorption spectrometry. The factors sample mass and digestion type were evaluated at two levels: 200/500 mg, and dry/wet, respectively. Principal component analysis allowed simultaneous discrimination of all the significant effects in one biplot. Wet digestion and mass of 200 mg were considered the best conditions. The decrease of 60% in sample mass allowed to save costs and reagents. The method was validated through the estimation of figures of merit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two methods for the determination of Ivermectin in veterinarian medications were developed and compared. One of the methods was based on UV spectrometry and the other on HPLC-UV. The former method was shown to be positively biased regarding the nominal concentrations of Ivermectin in different medications. The method of standard addition was unable to correct this bias, indicating significant matrix effects. The HPLC-UV method showed good linearity, throughput, recovery and limits of detection and quantitation adequate for its application in the evaluation of Ivermectin in medications. Several medications were evaluated and good agreement between our results and their nominal concentrations was found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work consists of the development and validation of analytical method for evaluation of glycyrrhizic acid, salicylic acid, and caffeine in chitosan-alginate nanoparticles by high performance liquid chromatography. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The methods were applied to nanoparticles suspensions containing the drugs and were able to determine the entrapment efficiency successfully. The best entrapment efficiency was achieved with the glycyrrhizic acid (95.4%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the evaluation of extraction strategies for the treatment of medicine samples to determine chromium and nickel by GFAAS. Different approaches for extraction were evaluated and the most efficient involved magnetic stirring. The metals were quantitatively extracted by stirring 0.20 g samples with 25 mL of 2.0 mol L-1 HCl solution for 60 min. The developed method was successfully applied for the determination of Cr and Ni in tablets containing antibiotics and raw materials, with cephalexin and ciprofloxacin as active ingredients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microwave synthesis is considered a breakthrough in the field of chemistry due to its benefits over conventional heating methods. We describe, for the first time, the total synthesis of phenytoin adapted for a microwave reactor, proposed as an experiment for undergraduate courses. When carried out with microwaves, the synthetic route provided phenytoin in 6 min and 30 s, while for conventional heating the total time was 170 min. The experiment also involves rapid identification of compounds by TLC, ¹H NMR, FT-IR and melting points determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Rancimat and accelerated stove tests were used to determine the oxidative stability of B100 biodiesel mixed with synthetic antioxidants. The predictive equations, with process variable, were obtained by applying a simplex-centroid design. Regardless of the antioxidant used, all assays carried out with the accelerated stove test presented storage time longer than 177.88 d, the greatest value obtained by applying the Rancimat test. The t test, applied to the parameters containing the process variable, showed a statistically significant difference (at the level of 5%) between the methods used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a green chemistry experiment for the synthesis of Erlenmeyer-Plöchl azalactones mediated by microwave irradiation, employing both dedicated and domestic equipment. Hippuric acid was reacted with equimolar amounts of benzaldehyde, p-chloro-benzaldehyde or p-N,N-dimethyl-benzaldehyde in acetic anhydride as the solvent. Acid hydrolysis of obtained 4-benzylidene-2-phenyloxazol-5(4H)-one under microwave and convectional heating afforded Z-α-(benzoylamino)cinnamic acid at a 51-61.5% yield. The UV-Vis molecular spectra of 4-benzylidene-2-phenyloxazol-5(4H)-one and 4-(4'-N,N-dimethylbenzylidene)-2-phenyloxazol-5(4H)-one were obtained in ethanol, CH2Cl2 and DMSO and bathochromic shift was observed for the latter azalactone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the use of both simple and sophisticated models in the study of electronic transitions was explored for a set of molecular systems: C2H4, C4H4, C4H6, C6H6, C6H8, "C8", C60, and [H2NCHCH(CHCH)kCHNH2]+, where k = 0 to 4. The simple model of the free particle (1D, 2D, and 3D boxes, rings or spherical surfaces), considering the boundary conditions, was found to yield similar results to the sophisticated theoretical methods such as EOM-CCSD/6-311++G** or TD(NStates=5,Root=1)-M06-2X/6-311++G**.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two methods using headspace solid-phase microextraction and gas chromatography - mass spectrometry were developed for the determination of polycyclic aromatic hydrocarbons (PAH) and BTEX. Best results were obtained using DVB/CAR/PDMS fiber, with 10 min extraction at 25 °C and 0.15 min desorption at 260 °C (BTEX), and PDMS/DVB fiber, with 60 min extraction at 90 °C, 10% NaCl and 5 min desorption at 270 °C (PAH). LOD intervals were 3x10-2 - 5x10-2 µg L-1 (BTEX) and 1.6x10-3 - 1.4 µg L-1 (PAH). The methods were applied to forty-five groundwater samples from monitoring wells of gas stations and only benzene level exceeded the limit established by Brazilian regulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a three-week mini-project for an Experimental Organic Chemistry course. The activities include N-C cross-coupling synthesis of N-(4-methoxyphenyl) benzamide in an adapted microwave oven by a copper catalyst (CuI). Abilities and concepts normally present in practical organic chemistry courses are covered: use of balances, volumetric glassware, separation of mixtures (liquid-liquid extraction and filtration), chromatographic techniques, melting point determination and stoichiometric calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports a practical case based on the use of microwave-assisted derivatization and GC-MS for the analysis of glucose. Using two different methods for derivatization, one reference compound and the calculated dipole moment, all the isomers of glucose were identified. Identification was corroborated for the assignment of structures using the mass spectra. With this work, students are expected to associate different types of information to solve the complex problem of the analysis of glucose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This aim of this work was to compare two methods for copper determination in insulating oils from power transformers by GFAAS. The first method was extraction induced by emulsion breaking, which determined the preconcentration of copper in an aqueous solution and exhibited a limit of quantification of 0.27 µg L-1. Also, a second method based on the direct introduction of samples into GFAAS in the form of detergent emulsions, prepared with Triton X-114 and HNO3, was investigated. In this case, the limit of quantification was 1.7 µg L-1. Seven samples of used oils were successfully analyzed by both methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method based on microwave-induced combustion (MIC) was applied for the decomposition of different types of edible seaweed (Nori, Hijiki and Wakame) for subsequent determination of bromine and iodine by inductively coupled plasma mass spectrometry (ICP-MS). Decomposition of 500 mg of each sample was achieved in less than 30 min. A single and diluted solution (150 mmol L-1 (NH4)2CO3) was used for the absorption of both analytes and a reflux step of 5 min was applied to improve analyte recoveries. Accuracy was evaluated using certified reference materials and agreement was between 103 and 108% for both elements.