978 resultados para Laser-plasma interaction
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Subjects taking a hydrogen pump blocking agent (omeprazole) develop bacterial overgrowth of the small intestine. We tested the hypothesis that this bacterial overgrowth produces menaquinones, which would meet the Vitamin requirement in situations of vitamin K deficiency. In a crossover-type design, 13 healthy Volunteers eating a phylloquinone-restricted diet for 35 d were randomly assigned to take omeprazole during the first period of study or starting on day 15 until the end of the study. Coagulation times, serum osteocalcin [total osteocalcin and undercarboxylated osteocalcin (ucOC)], plasma phylloquinone, urinary gamma-carboxyglutamic acid, and plasma undercarboxylated prothrombin (PIVKA-II) were measured. Plasma phylloquinone concentrations declined 82% with dietary phylloquinone restriction (P < 0.05) and were not significantly different in the period when the diet was combined with omeprazole treatment (P > 0.05), the mean value for PIVKA-II during the phylloquinone-restricted diet significantly increased 5.7-fold from baseline (P < 0.05); however, the combination of omeprazole treatment and the phylloquinone-restricted diet significantly reduced PIVKA-II values by 21% (P < 0.05) compared with the diet period alone. There were no alterations in total or percentage ucOC concentrations during the phylloquinone-restricted diet or during the period of diet plus omeprazole treatment. Our data support the hypothesis that bacterial overgrowth results in the synthesis and absorption of menaquinones. These menaquinones contribute to vitamin K nutriture during dietary phylloquinone restriction, but not enough to restore normal vitamin K status.
Resumo:
Annexin 1 (ANX-A1) exerts antimigratory actions in several models of acute and chronic inflammation, This is related to its ability to mimic the effect of endogenous ANX-A1 that is externalized on neutrophil adhesion to the postcapillary endothelium. In the present study we monitored ANX-A1 expression and localization in intravascular and emigrated neutrophils, using a classical model of rat peritonitis, For this purpose, a pair of antibodies raised against the ANX-A1 N-terminus tie, able to recognize intact ANX-A1) or the whole protein tie, able to interact with all ANX-A1 isoforms) was used by immunofluorescence and immunocytochemistry analyses. The majority (similar to 50%) of ANX-A1 on the plasma membrane of intravascular neutrophils was intact. Extravasation into the subendothelial matrix caused loss of this pool of intact protein (to similar to6%), concomitant with an increase in total amount of the protein; only similar to 25% of the total protein was now recognized by the antibody raised against the N-terminus tie, it was intact). In the cytoplasm of these cells, ANX-A1 was predominantly associated with large vacuoles, possibly endosomes, In situ hybridization confirmed de novo synthesis of ANX-A1 in the extravasated cells. In conclusion, biochemical pathways leading to the externalization, proteolysis, and synthesis of ANX-A1 are activated during the process of neutrophil extravasation.
Resumo:
Reports in the literature have shown that acute or chronic zinc administration may cause hyperglycemia, with a fall in serum or insular insulin occurring in experimental animals. on the other hand, under conditions of both acute and chronic hyperglycemia, an increase, a decrease, or a normal level of blood zinc has been observed in studies conducted on humans. Thus, the objective of the investigation described here was to determine the relationship existing among zinc, glucose, and insulin under acute conditions. Thirty-six subjects of both sexes (mean age, 23 yr) were tested at 7:00 A.M. after a 12-h fast. Two antecubital veins of both forearms were punctured and maintained with physiological saline. Three experiments were performed in which zinc was administered orally, and hypertonic glucose and tolbutamid were administered intravenously. Blood samples were then collected over a period ranging from 93 to 240 min after the basal times of - 30 and 0 min. Hyperzincemia did not cause changes in plasma glucose or insulin either in the absence of or during perfusion of glucose. Hyperglycemia, hypoglycemia, and hyperinsulinemia did not modify serum zinc levels. These results demonstrate that acute zinc administration did not change carbohydrate metabolism and that sudden variations in glucose and insulin levels did not modify the serum profile of zinc.
Resumo:
This study was conducted to analyze the ablation rate and micromorphological aspects of microcavities in enamel and dentin of primary and permanent teeth using a Er:YAG laser system. Micromorphological evaluation has been performed in terms of permanent teeth; however, little information about Er: YAG laser interaction with primary teeth can be found in the literature. Because children have been the most beneficiary patients with laser therapy in our offices, it is extremely necessary to compare the effects of this kind of laser system on the enamel and dentin of permanent and primary teeth. In this study, we used eleven intact primary anterior exfoliated teeth and six extracted permanent molar teeth. We used a commercial laser system: a Er: YAG Twin Light laser system (Fotona Medical Lasers, Slovenia) at 2940 nm, changing average energy levels per pulse ( 100, 200, 300, and 400 mJ) producing 48 microcavities in enamel and dentin of primary and permanent teeth. Primary teeth are more easily ablated than are permanent teeth, when related to enamel or dentin. However, while this laser system is capable of slowly revealing the enamel's microstructure, in dentin only the lowest laser energies permit this kind of observation, more easily decomposing the original tissue aspect, when related to primary or permanent teeth. Statistically, the only different factor at the 5% level was an energy per pulse of 400 mJ, confirming the results found in SEM. Our results showed that dentin in both primary and permanent teeth is less resistant to Er: YAG laser ablation; this fact is easily observed under SEM observation and through the ablation rate evaluation.
Resumo:
Thin polymer films were grown in radio frequency discharges containing C2H2. Actinometry revealed the trend in the plasma concentration of the CH species as a function of the operating pressure. The C-H bond density in the films, revealed by infrared analysis, was found to increase with the pressure of C2H2 in a similar way to that of the concentration of the CH species in the discharge. From transmission ultraviolet-visible spectroscopy data, optical parameters of the polymers, namely, the refractive index and the optical gap, were calculated. For the range of pressure studied, the refractive index decreased from 1.73 to 1.63 and the optical gap increased from 2.4 to 3.3 eV. Finally, measurements of the residual stress of the polymer films were carried out by the bending beam method, using a He-Ne laser, yielding values from 0.05 to 0.3 GPa. (C) 1995 American Vacuum Society.
Resumo:
Surface modifications have been applied in endosteal bone devices in order to improve the osseointegration through direct contact between neoformed bone and the implant without an intervening soft tissue layer. Surface characteristics of titanium implants have been modified by addictive methods, such as metallic titanium, titanium oxide and hydroxyapatite powder plasma spray, as well as by subtractive methods, such as acid etching, acid etching associated with sandblasting by either AlO2 or TiO2, and recently by laser ablation. Surface modification for dental and medical implants can be obtained by using laser irradiation technique where its parameters like repetition rate, pulse energy, scanning speed and fluency must be taken into accounting to the appropriate surface topography. Surfaces of commercially pure Ti (cpTi) were modified by laser Nd:YVO4 in nine different parameters configurations, all under normal atmosphere. The samples were characterized by SEM and XRD refined by Rietveld method. The crystalline phases alpha Ti, beta Ti, Ti6O, Ti3O and TiO were formed by the melting and fast cooling processes during irradiation. The resulting phases on the irradiated surface were correlated with the laser beam parameters: the aim of the present work was to control titanium oxides formations in order to improve implants osseointegration by using a laser irradiation technique which is of great importance to biomaterial devices due to being a clean and reproducible process. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
The results described in this work are part of a systematic search for long wavelength laser lines to be used in high magnetic field EPR applications and in plasma diagnostic. Four new far-infrared laser lines of CH2 = CF2 (1,1 difluoroethylene), optically pumped by a waveguide CO2 laser, have been discovered and characterized in wavelength, polarization relative to the pumping radiation and offset relative to the CO2 center frequency. New measurements of polarization and offset of 5 already known laser lines are also reported. A table of all of the known CO2 pumped FIR laser lines from this molecule is given.
Resumo:
Atrophic gastritis patients have intestinal bacterial overgrowth which could produce menaquinones. The aim of this study was to evaluate the interaction between a diet low in phylloquinone and minidoses of warfarin in subjects with and without bacterial overgrowth. Subjects with atrophic gastritis (indicated by serum pepsinogen ratio) and healthy volunteers were studied while fed a restrictive phylloquinone diet and while receiving a minidose of warfarin. Coagulation times, serum osteocalcin, serum undercarboxylated osteocalcin, plasma phylloquinone, plasma K-epoxide, plasma undercarboxylated prothrombin (PIVKA)-II and urinary gamma-carboxyglutamic acid (Gla) were measured. At baseline, there were no differences between groups for any variable measured. Comparisons between baseline and post intervention in both groups, showed significant increases in circulating levels of K-epoxide, PIVKA II and undercarboxylated osteocalcin. However, no differences were observed when comparisons were made between groups. Our data do not support the hypothesis that bacterial synthesis of menaquinones in patients with bacterial overgrowth due to atrophic gastritis confers considerable resistance to the effect of warfarin.
Resumo:
Most studies on the antioxidants, lipoic acid (LA) and ascorbic acid (AA), focused on species that, unlike teleost fish, are not scurvy-prone, and are able to synthesize AA. The antioxidant properties of LA may make it useful in aquaculture nutrition, but several effects must first be investigated, and we address here plasma free amino acids (FAA). In mammals, LA and AA in high doses were claimed to alter plasma FAA profile; to our knowledge, however, no data are available in fish. We therefore studied the effects of dietary LA and AA on plasma FAA in the South American teleost fish pacu, which is being used increasingly in aquaculture. LA treatment decreased concentrations of 18 of 23 individual FAA; specifically, dispensable and total FAA were significantly affected. Ornithine was elevated (+26%) in LA-treated fish and significantly decreased ratios of plasma [Arg]/[Orn] and other individual [FAA]/[Orn] were observed. LA and AA both affected sulfur FAA concentrations. Plasma cystine levels were significantly increased in the LA-supplemented groups. AA had little effect on most amino acids, and no interaction with LA was detected. AA supplementation did, however, significantly lower taurine (-42%) and cystathionine (-31%) levels in plasma. No effect on the branched chain:aromatic amino acid ratios was observed. The data indicate that at the dietary level studied, LA and AA independently affect selected plasma FAA in pacu, and suggest that any use of LA in particular as a dietary supplement should take into account an altered plasma FAA profile.
Resumo:
This study aimed to evaluate the effectiveness of low intensity laser therapy (LILT) in 30 patients presenting temporomandibular joint (TMJ) pain and mandibular dysfunction in a random and double-blind research design. The sample, divided into experimental group (1) and placebo group (2), was submitted to the treatment with infrared laser (780 nm, 30 mW, 10 s, 6.3 J/cm2) at three TMJ points. The treatment was evaluated throughout six sessions and 15, 30 and 60 days after the end of the therapy, through visual analogue scale (VAS), range of mandibular movements and TMJ pressure pain threshold. The results showed a reduction in VAS (p < 0.001) and through the ANOVA with repeated measures it was observed that the groups did not present statistically significant differences (P = 0.2060), as the averages of the evaluation times (P = 0.3955) and the interaction groups evaluation times (P = 0.3024), considering the MVO. The same occurred for RLE (P = 0.2988, P = 0.1762 and P = 0.7970), LLE (P = 0.3265, P = 0.4143 and P = 0.0696), PPTD (P = 0.1558, P = 0.4695 and P = 0.0737) and PPTE (P = 0.2376, P = 0.3203 and P = 0.0624). For PE, there were not statistically significant differences for groups (P = 0.7017) and the interaction groups evaluation times (P = 0.6678), even so in both groups the PE varied with time (P = 0.0069). © 2005 Blackwell Publishing Ltd.
Resumo:
The purpose of the present study was to evaluate, using a biomechanical test, the force needed to remove implants with surface modification by laser (Nd:YAG) in comparison with implants with machined surfaces. Twenty-four rabbits received one implant with each surface treatment in the tibia, machined surface (MS) and laser-modified surface (LMS). After 4, 8 and 12 weeks of healing, the removal torque was measured by a torque gauge. The surfaces studied were analyzed according to their topography, chemical composition and roughness. The average removal torque in each period was 23.28, 24.0 and 33.85 Ncm for MS, and 33.0, 39.87 and 54.57 Ncm for LMS, respectively. The difference between the surfaces in all periods of evaluation was statistically significant (p < 0.05). Surface characterization showed that a deep and regular topography was provided by the laser conditioning, with a great quantity of oxygen ions when compared to the MS. The surface micro-topography analysis showed a statistical difference (p < 0.01) between the roughness of the LMS (R a = 1.38 ± 0.23 μm) when compared to that of the MS (R a = 0.33 ± 0.06 μm). Based on these results, it was possible to conclude that the LMS implants' physical-chemical properties increased bone-implant interaction when compared to the MS implants. © 2009 Sociedade Brasileira de Pesquisa Odontológica.
Resumo:
The aim of this study was to evaluate the effect of specific parameters of low-level laser therapy (LLLT) on biofilms formed by Streptococcus mutans, Candida albicans or an association of both species. Single and dual-species biofilms - SSB and DSB - were exposed to laser doses of 5, 10 or 20 J/cm 2 from a near infrared InGaAsP diode laser prototype (LASERTable; 780 ± 3 nm, 0.04 W). After irradiation, the analysis of biobilm viability (MTT assay), biofilm growth (cfu/mL) and cell morphology (SEM) showed that LLLT reduced cell viability as well as the growth of biofilms. The response of S. mutans (SSB) to irradiation was similar for all laser doses and the biofilm growth was dose dependent. However, when associated with C. albicans (DSB), S. mutans was resistant to LLLT. For C. albicans, the association with S. mutans (DSB) caused a significant decrease in biofilm growth in a dose-dependent fashion. The morphology of the microorganisms in the SSB was not altered by LLLT, while the association of microbial species (DSB) promoted a reduction in the formation of C. albicans hyphae. LLLT had an inhibitory effect on the microorganisms, and this capacity can be altered according to the interactions between different microbial species.
Resumo:
The purpose of this study was to evaluate commercially pure titanium implant surfaces modified by laser beam (LS) and LS associated with sodium silicate (SS) deposition, and compare them with machined surface (MS) and dual acid-etching surfaces (AS) modified. Topographic characterization was performed by scanning electron microscopy-X-ray energy dispersive spectroscopy (SEM-EDX), and by mean roughness measurement before surgery. Thirty rabbits received 60 implants in their right and left tibias. One implant of each surface in each tibia. The implants were removed by reverse torque for vivo biomechanical analysis at 30, 60, and 90 days postoperative. In addition, the surface of the implants removed at 30 days postoperative was analyzed by SEM-EDX. The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of LS and SS were statistically higher than AS and MS. At 30 days, values removal torque LS and SS groups showed a statistically significant difference (p < 0.05) when compared with MS and AS. At 60 days, groups LS and SS showed statistically significant difference (p < 0.05) when compared with MS. At 90 days, only group SS presented statistically higher (p < 0.05) in comparison with MS. The authors can conclude that physical chemistry properties and topographical of LS and SS implants increases bone-implant interaction and provides higher degree of osseointegration when compared with MS and AS. © 2012 Wiley Periodicals, Inc.
Resumo:
In the present study, different freezing systems (Styrofoam box and Mini Digitcool ZH 400) and storage volumes (0.5- and 0.25-mL straws) were compared with regard to sperm kinetics and plasma membrane integrity of frozen and thawed semen. For that, three ejaculates from four animals were frozen in Styrofoam box and Mini Digitcool ZH 400 machine. The 0.5-mL straws were thawed at 46°C for 20 seconds, and the 0.25-mL straws were thawed at 46°C for 12 seconds. Statistical analysis was performed using program R of descriptive analysis box plot, followed by analysis of variance using PROC MIXED of SAS 9.1 package. Variances of 5% were considered as different. There was no interaction between the straw sizes and volumes; however, statistical differences were observed between the semen storage volumes. The 0.5-mL straws had higher total motility (%), progressive motility (%), average path velocity (μm/s), straight-line velocity (μm/s), curvilinear velocity (μm/s), and rapid sperm percentage (%) than the 0.25-mL straws. However, plasma membrane integrity analysis did not differ between the two straws. Thus, it is possible to conclude that equine sperm cryopreserved in 0.5-mL straws has better sperm kinetics than when stored in 0.25-mL straws. Additionally, it is possible to conclude that automated systems that enable faster freezing rates result in a seminal quality that is similar to the one obtained by the conventional system using Styrofoam boxes. © 2013 Elsevier Inc.