913 resultados para Kirby and Bauer method
Resumo:
Superparamagnetic iron oxide nanoparticles (SPIONs) are applied in stem cell labeling because of their high magnetic susceptibility as compared with ordinary paramagnetic species, their low toxicity, and their ease of magnetic manipulation. The present work is the study of CD133(+) stem cell labeling by SPIONs coupled to a specific antibody (AC133), resulting in the antigenic labeling of the CD133+ stem cell, and a method was developed for the quantification of the SPION content per cell, necessary for molecular imaging optimization. Flow cytometry analysis established the efficiency of the selection process and helped determine that the CD133 cells selected by chromatographic affinity express the transmembrane glycoprotein CD133. The presence of antibodies coupled to the SPION, expressed in the cell membrane, was observed by transmission electron microscopy. Quantification of the SPION concentration in the marked cells using the ferromagnetic resonance technique resulted in a value of 1.70 x 10 (13) mol iron (9.5 pg) or 7.0 x 10 (6) nanoparticles per cell ( the measurement was carried out in a volume of 2 mu L containing about 6.16 x 10 5 pg iron, equivalent to 4.5 x 10 (11) SPIONs). (c) 2008 Elsevier Inc. All rights reserved.
Resumo:
Objective: To assess the rate of comorbidities and the functional impairment associated with the social anxiety disorder (SAD), with an emphasis on the so-called subthreshold clinical signs and symptoms. Method: Psychiatric comorbidities and psychosocial functioning were evaluated in 355 volunteers (college students) who had been diagnosed as SAD (n = 141), Subthreshold SAD (n = 92) or Controls (n = 122). Results: The rate of comorbidities was 71.6% in the SAD group and 50% in subjects with Subthreshold SAD, both significantly greater than Controls (28.7%). Concerning psychosocial functioning, the SAD group had higher impairment than the other two groups in all domains evaluated, and subjects with Subthreshold SAD presented intermediate values. Conclusion: The rates of psychiatric comorbidities and the impairment of psychosocial functioning increase progressively along the spectrum of social anxiety. The fact that Subthreshold SAD causes considerable disability and suffering in comparison with control subjects justifies a review of the validity of the diagnostic criteria.
Resumo:
BACKGROUND: Mesenchymal stem cells (MSCs) have been considered for human regenerative therapy applications, and safe culture and expansion protocols are needed especially in the context of interspecies contamination. Human platelet lysate (PL) has been proposed as animal serum substitute during in vitro MSC expansion. In this work, a simplified and efficient method to obtain autologous PL to replace animal serum in cell culture applications is described. STUDY DESIGN AND METHODS: PL obtained by freezing and centrifugation procedures was tested as medium supplement for human adipose mesenchymal stem cell (hASC) culture. Differential proliferation, immunophenotypic changes, and differentiation under PL or fetal bovine serum (FBS) were assessed. RESULTS: In contrast to 10% FBS supplementation, cell population doubling time was significantly lower when hASCs were cultured with the same concentration of PL ( PL 22.9 +/- 1.5 hr vs. FBS 106.7 +/- 6.5 hr, t test, p < 0.05). Furthermore, hASCs maintained with 2.5% PL supplementation also showed satisfactory results. Immunophenotypic analysis revealed no differences between hASCs cultivated with PL or FBS supplementation and both cultures retained the potential to differentiate into adipose cells. These results demonstrate that autologous PL obtained from the same donor can be used as animal serum substitute in hASC culture. CONCLUSIONS: Taken together, evidence is provided that platelets provided by a single donor are sufficient to obtain PL for hASC propagation for clinical-scale applications mitigating the potential untoward side effects associated with the use of animal-derived reagents.
Resumo:
Background. The pericardial biopsy has opened a new perspective for the etiologic diagnosis of pericardial effusions, because adequate pericardial visualization via the use of a video camera can provide more accurate results. We assessed the usefulness of videopericardioscopy for the diagnosis and treatment of pericardial effusion of indeterminate origin. Methods. We conducted a retrospective study of clinical data from patients who underwent videopericardioscopy examination for pericardial effusion without an established diagnosis. The video-assisted pericardioscopy procedure was performed through a small incision in the xiphoid area. Results. From January 1998 to January 2007, 101 consecutive patients underwent videopericardioscopy evaluation for pericardial effusion. Ten patients were excluded because of lack of data. Fifty men and 41 women were included ( mean age, 50 years; range, 14-76 years). All of the patients had moderate or significant pericardial effusion as demonstrated by echocardiography or computed tomography. The following diagnoses for the pericardial effusions were established: nonspecific inflammation, 50 cases ( 54.94%); neoplastic disorders, 22 cases ( 24.17%); tuberculous, 11 cases ( 12.08%); bacterial inflammatory process, 3 cases ( 3.29%); chylopericardial, 2 cases ( 2.19%); fungal infection, 2 cases ( 2.19%); and viral infection, 1 case ( 1.09%). Pericardioscopy evaluation provided the definitive diagnosis via the pericardial biopsy in 36.26% of the cases and via the results of fluid analyses in 13.18% of the cases; the use of both methods established the definitive diagnosis in 45.05% of the cases in this group of patients. The overall morbidity rate was 4.3%, and the most common complication was arrhythmia due to intraoperative manipulation, which ceased with the removal of the instruments from the pericardial cavity. We had 1 death, by cardiac tamponade, in the perioperative period. Conclusion. Videopericardioscopy is a safe and efficient method for obtaining a better diagnosis of and satisfactory therapeutic results for pericardial effusions of indeterminate cause, and such results are obtained via an improved exploration of the pericardial cavity.
Resumo:
Total scalp avulsion is a devastating injury in clinical practice. It often occurs in female adults, being rare in children. The standard treatment for scalp avulsion is microsurgical replantation, when feasible. Coverage becomes a major problem when replantation fails or is contraindicated, resulting in significant morbidity and requiring multiple procedures. In this article, in addition to reviewing the literature, we report a historical method for obtaining skin coverage after failure of replantation. The authors report a case of a 10-year-old girl who had her scalp totally avulsed by an agricultural machine, including her right auricle. Microsurgery scalp replantation was attempted immediately after fluid resuscitation. The surgery failed probably due to the long time interval between trauma and surgery, which resulted in total ischemic time of 11 h and consequently made vascular microanastomosis impracticable. Multiple trephination of the calvarium was performed in order to expose the diploe. After 4 weeks, granulation tissue from the holes began to cover the defect, allowing the formation of a vascular bed suitable for skin grafting. Total scalp avulsion in children is seldom reported in the literature. Therefore, its management is both difficult and challenging. The exposure of the diploe with multiple burr holes is a safe and effective method for treating this injury. It may be considered, along with skin grafting, a good therapeutic alternative to be used when microsurgical replantation fails or is not feasible.
Resumo:
Since circulating leukocytes, mainly B and T cells, continuously maintain vigilant and comprehensive immune surveillance, these cells could be used as reporters for signs of infection or other pathologies, including cancer. Activated lymphocyte clones trigger a sensitive transcriptional response, which could be identified by gene expression profiling. To assess this hypothesis, we conducted microarray analysis of the gene expression profile of lymphocytes isolated from immunocompetent BALB/c mice subcutaneously injected with different numbers of tumorigenic B61 fibrosarcoma cells. Flow cytometry demonstrated that the number of circulating T (CD3(+)CD4(+) or CD3(+)CD8(+)) or B (CD19(+)) cells did not change. However, the lymphocytes isolated from tumor cell-injected animals expressed a unique transcriptional profile that was identifiable before the development of a palpable tumor mass. This finding demonstrates that the transcriptional response appears before alterations in the main lymphocyte subsets and that the gene expression profile of peripheral lymphocytes can serve as a sensitive and accurate method for the early detection of cancer. Exp Biol Med 234:802-812, 2009
Resumo:
Deficiency of the lysosomal glucocerebrosidase (GCR) enzyme results in Gaucher`s disease, the most common inherited storage disorder. Treatment consists of enzyme replacement therapy by the administration of recombinant GCR produced in Chinese hamster ovary cells. The production of anti-GCR antibodies has already been described with placenta-derived human GCR that requires successive chromatographic procedures. Here, we report a practical and efficient method to obtain anti-GCR polyclonal antibodies against recombinant GCR produced in Escherichia coli and further purified by a single step through nickel affinity chromatography. The purified GCR was used to immunize BALB/c mice and the induction of anti-GCR antibodies was evaluated by enzyme-linked immunosorbent assay. The specificity of the antiserum was also evaluated by western blot analysis against recombinant GCR produced by COS-7 cells or against endogenous GCR of human cell lines. GCR was strongly recognized by the produced antibodies, either as cell-associated or as secreted forms. The detected molecular masses of 59-66 kDa are in accordance to the expected size for glycosylated GCR. The GCR produced in E. coli would facilitate the production of polyclonal (shown here) and monoclonal antibodies and their use in the characterization of new biosimilar recombinant GCRs coming in the near future.
Resumo:
Purpose: To investigate in vitro the effect of retentive grooves, GIC type and insertion method on the fracture resistance of Class II glass-ionomer cement (GIC) restorations. Methods: Premolars were divided into 12 groups (n=10) according to three variables: retentive grooves [presence (PR) or absence AR)], GICs type [Ketac-Molar (KM), Fuji VIII (F8) and RelyX Luting (RX)], and insertion method [syringe injector (SI) or spoon excavator (SE)]. The specimens were subjected to fracture resistance test. Data were submitted to three-way ANOVA and multiple comparisons were performed using a Tukey test (P < 0.05). Results: Mean fracture resistance values (Kgf) +/- standard deviations (SD) were: KM (PR+SI) 65.66 +/- 2.5; KM (PR+SE) = 62.58 +/- 2.1; KM (AR+SI) = 57.11 +/- 1.9; KM (AR+SE) = 51.94 +/- 2.3; F8 (PR+SI) = 63.05 +/- 2.1; F8 (PR+SE) = 60.12 +/- 2.3; F8 (AR+SI) = 55.11 +/- 1.9; F8(AR+SE)=49.20 +/- 1.6; RX (PR+SI)=50.99 +/- 2.4; RX (PR+SE)=48.81 +/- 2.5; RX (AR+SI)=45.53 +/- 2.6; RX (AR+SE)=41.88 +/- 3.0. Statistically significant differences were observed among all the groups tested (P=0.001). There was significant difference when pooled means for GIC type were compared with retentive grooves (P=0.01) and when pooled means for retentive grooves were compared with insertion method (P=0.01).
Resumo:
Dry socket is one of the most studied complications in dentistry, and a great number of studies have searched for an effective and safe method for its prevention and treatment. One of the great clinical challenges since the first case was reported has been the inconsistency and differences in the various definitions of dry socket and the criteria used for diagnosis. The pathophysiology, etiology, prevention, and treatment of dry socket are very important in the practice of oral surgery. The aim of the present report was to review and discuss each aspect. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:1922-1932, 2010
Resumo:
In this paper, an attempt was made to investigate a fundamental problem related to the flexural waves excited by rectangular transducers. Due to the disadvantages of the Green's function approach for solving this problem, a direct and effective method is proposed using a multiple integral transform method and contour integration technique. The explicit frequency domain solutions obtained from this newly developed method are convenient for understanding transducer behavior and theoretical optimization and experimental calibration of rectangular transducers. The time domain solutions can then be easily obtained by using the fast Fourier transform technique. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Large chemical libraries can be synthesized on solid-support beads by the combinatorial split-and-mix method. A major challenge associated with this type of library synthesis is distinguishing between the beads and their attached compounds. A new method of encoding these solid-support beads, 'colloidal bar-coding', involves attaching fluorescent silica colloids ('reporters') to the beads as they pass through the compound synthesis, thereby creating a fluorescent bar code on each bead. In order to obtain sufficient reporter varieties to bar code extremely large libraries, many of the reporters must contain multiple fluorescent dyes. We describe here the synthesis and spectroscopic analysis of various mono- and multi-fluorescent silica particles for this purpose. It was found that by increasing the amount of a single dye introduced into the particle reaction mixture, mono- fluorescent silica particles of increasing intensities could be prepared. This increase was highly reproducible and was observed for six different fluorescent dyes. Multi-fluorescent silica particles containing up to six fluorescent dyes were also prepared. The resultant emission intensity of each dye in the multi-fluorescent particles was found to be dependent upon a number of factors; the hydrolysis rate of each silane-dye conjugate, the magnitude of the inherent emission intensity of each dye within the silica matrix, and energy transfer effects between dyes. We show that by varying the relative concentration of each silane-dye conjugate in the synthesis of multi-fluorescent particles, it is possible to change and optimize the resultant emission intensity of each dye to enable viewing in a fluorescence detection instrument.
Resumo:
The detection of Neisseria gonorrhoeae by the polymerase chain reaction (PCR) is now recognized as a sensitive and specific method of diagnosing infection by the organism. In this Study 152 urine specimens were examined for N. gonorrhoeae by a real-time PCR method using the LightCycler platform and results were compared to an in-house PCR assay using an ELISA-based detection method. N. gonorrhoeae DNA was detected in 29 (19%) specimens by LightCycler PCR (LC-PCR) and in 31 (20%) specimens by the in house PCR method. The LightCycler assay proved to be specific and 94% sensitive when compared to the in house PCR method. These features combined with the rapid turn-around time for results makes the LC-PCR particularly suitable for the detection of N. gonorrhoeae in a routine clinical laboratory. (C) 2002 Elsevier Science Inc. All rights reserved.
Resumo:
Radio-frequency (RF) coils are a necessary component of magnetic resonance imaging (MRI) systems. When used in transmit operation, they act to generate a homogeneous RF magnetic field within a volume of interest and when in receive operation, they act to receive the nuclear magnetic resonance signal from the RF-excited specimen. This paper outlines a procedure for the design of open RF coils using the time-harmonic inverse method. This method entails the calculation of an ideal current density on a multipaned planar surface that would generate a specified magnetic field within the volume of interest. Because of the averaging effect of the regularization technique in the matrix solution, the specified magnetic field is shaped within an iterative procedure until the generated magnetic field matches the desired magnetic field. The stream-function technique is used to ascertain conductor positions and a method of moments package is then used to finalize the design. An open head/neck coil was designed to operate in a clinical 2T MRI system and the presented results prove the efficacy of this design methodology.
Resumo:
Quantification of stress echocardiography may overcome the training requirements and subjective nature of visual wall motion score (WMS) assessment, but quantitative approaches may be difficult to apply and require significant time for image processing. The integral of long-axis myocardial velocity is displacement, which may be represented as a color map over the left ventricular myocardium. This study was designed to explore the feasibility and accuracy of measuring long-axis myocardial displacement, derived from tissue Doppler, for the detection of coronary artery disease (CAD) during dobutamine stress echocardiography (DBE). One hundred thirty patients underwent standard DBE, including 30 patients at low risk of CAD, 30 patients with normal coronary angiography (both groups studied to define normal ranges of displacement), and 70 patients who underwent coronary angiography in whom the accuracy of normal ranges was tested. Regional myocardial displacement was obtained by analysis of color tissue Doppler apical images acquired at peak stress. Displacement was compared with WMS, and with the presence of CAD by angiography. The analysis time was 3.2 +/- 1.5 minutes per patient. Segmental displacement was correlated with wall motion (normal 7.4 +/- 3.2 mm, ischemia 5.8 +/- 4.2 mm, viability 4.6 +/- 3.0 mm, scar 4.5 +/- 3.5 mm, p <0.001). Reversal of normal base-apex displacement was an insensitive (19%) but specific (90%) marker of CAD. The sum of displacements within each vascular territory had a sensitivity and specificity of 89% and 79%, respectively, for prediction of significant CAD, compared with 86% and 78%, respectively, for WMS (p = NS). The displacements in the basal segments had a sensitivity and specificity of 83% and 78%, respectively (p = NS). Regional myocardial displacement during DBE is feasible and offers a fast and accurate method for the diagnosis of CAD. (C),2002 by Excerpta Medica, Inc.
Resumo:
We present an efficient and robust method for calculating state-to-state reaction probabilities utilising the Lanczos algorithm for a real symmetric Hamiltonian. The method recasts the time-independent Artificial Boundary Inhomogeneity technique recently introduced by Jang and Light (J. Chem. Phys. 102 (1995) 3262) into a tridiagonal (Lanczos) representation. The calculation proceeds at the cost of a single Lanczos propagation for each boundary inhomogeneity function and yields all state-to-state probabilities (elastic, inelastic and reactive) over an arbitrary energy range. The method is applied to the collinear H + H-2 reaction and the results demonstrate it is accurate and efficient in comparison with previous calculations. (C) 2002 Elsevier Science B.V. All rights reserved.