947 resultados para Intermittent microwave


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability of cryogenic photonic crystals to carry out high performance microwave signal processing operations has been developed into systems that can: rapidly record broadband microwave spectra with fine resolution and high dynamic range; search for patterns in 40 gigabits per second data streams; and communicate via spread- spectrum signals that are well below the noise floor. The basic concepts of the technology and its many applications, along with an overview of university-industry partnerships and the growing photonics industry in Bozeman, will be presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the hypothesis that the need for clean intermittent self-catheterization after botulinum neurotoxin type A injections is outweighed by the efficacy of this treatment, so that clean intermittent self-catheterization is not a burden for patients with refractory idiopathic detrusor overactivity. METHODS: Women undergoing intradetrusor injections of 200 units botulinum neurotoxin type A for refractory idiopathic detrusor overactivity were evaluated prospectively. Clean intermittent self-catheterization was discussed with all patients and its possible need after botulinum neurotoxin type A treatment. As indicator of quality of life, lower urinary tract symptom distress and effect on daily activities were assessed using the validated Urogenital Distress Inventory (UDI-6) and Incontinence Impact Questionnaire (IIQ-7) before and 4 weeks after receiving botulinum neurotoxin type A injections. RESULTS: Mean age of the 65 women was 51 years, and all voided spontaneously before botulinum neurotoxin type A injections. After botulinum neurotoxin type A treatment, 28 (43%) required clean intermittent self-catheterization. Mean UDI-6 and IIQ-7 scores reduced from 61 to 33 (P<.001) and 62 to 30 (P<.001) in women performing clean intermittent self-catheterization and from 60 to 28 (P<.001) and 64 to 25 (P<.001) in those who did not, respectively. Comparison of quality of life in women performing clean intermittent self-catheterization and in those who did not revealed no significant differences before and after botulinum neurotoxin type A treatment. CONCLUSION: Clean intermittent self-catheterization after botulinum neurotoxin type A intradetrusor injections did not impair quality of life in appropriately informed and selected women in the short term. All patients should be informed of the potential need for clean intermittent self-catheterization after botulinum neurotoxin type A injections, and a willingness to do so should be a prerequisite for this still unlicensed off-label treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To assess patients' perception of clean intermittent self-catheterization (CISC) for voiding dysfunction. PATIENTS AND METHODS: A total of 101 patients performing CISC because of voiding dysfunction were invited to participate in this questionnaire survey. The response rate was 91% (92/101). RESULTS: The mean time over which CISC was performed was 5 years (standard deviation (SD) +/- 6.3) and the mean frequency of CISC per day was three times (SD +/- 2). Almost 80% (72/92) of the patients perceived CISC as easy or very easy and CISC did not interfere at all or interfered a little bit with work or other regular daily activities in more than 80% (76/92). Almost 90% (80/92) reported no or minimal pain while performing CISC. This did not interfere at all or interfered a little bit with work or other regular daily activities in almost 90% (80/92). Quality of life improved considerably due to CISC in more than 60% (56/92) and 12% (11/92) complained of a deterioration. In multivariable analysis, severe pain performing CISC (odds ratio 20.9, 95% confidence interval 1.7-259.9, P = 0.018) was the only factor that predicted poor quality of life. CONCLUSIONS: The majority of patients considered CISC to be an easy and painless procedure which did not interfere with daily activities. Consequently, quality of life improved in more than 60% of the patients. Therefore, CISC does not appear to be a burden for the patient and, from a patient's perspective, can be recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intermittent and continuous renal replacement therapies (RRTs) are available for the treatment of acute renal failure (ARF) in the intensive care unit (ICU). Although at present there are no adequately powered survival studies, available data suggest that both methods are equal with respect to patient outcome. Therefore, cost comparison between techniques is important for selecting the modality. Expenditures were prospectively assessed as a secondary end point during a controlled, randomized trial comparing intermittent hemodialysis (IHD) with continuous venovenous hemodiafiltration (CVVHDF). The outcome of the primary end points of this trial, that is, ICU and in-hospital mortality, has been previously published. One hundred twenty-five patients from a Swiss university hospital ICU were randomized either to CVVHDF or IHD. Out of these, 42 (CVVHDF) and 34 (IHD) were available for cost analysis. Patients' characteristics, delivered dialysis dose, duration of stay in the ICU or hospital, mortality rates, and recovery of renal function were not different between the two groups. Detailed 24-h time and material consumption protocols were available for 369 (CVVHDF) and 195 (IHD) treatment days. The mean daily duration of CVVHDF was 19.5 +/- 3.2 h/day, resulting in total expenditures of Euro 436 +/- 21 (21% for human resources and 79% for technical devices). For IHD (mean 3.0 +/- 0.4 h/treatment), the costs were lower (Euro 268 +/- 26), with a larger proportion for human resources (45%). Nursing time spent for CVVHDF was 113 +/- 50 min, and 198 +/- 63 min per IHD treatment. Total costs for RRT in ICU patients with ARF were lower when treated with IHD than with CVVHDF, and have to be taken into account for the selection of the method of RRT in ARF on the ICU.