998 resultados para Implante dentales
Resumo:
The objective of this study was to evaluate the impact of replacing conventional mandibular complete dentures by complete fixed dentures on the oral health-related quality of life and kinesiographic parameters of maxillary edentulous patients. Material and Methods: edentulous patients (n = 16) received one set of new complete dentures and after the intraoral adjustments and adaptation period (30 days), the Brazilian version of Oral Health Impact Profile for assessing edentulous subjects (Ohip-Edent) was used to evaluate the oral health-related quality of life (OHQOL) of the participants. Additionally, the kinesiograph instrument K6-I (Myotronics Research Inc., Seattle, WA) was used to record opening and closure range of movement, mandibular movement, and the pattern of maxillary complete denture movement on chewing. Afterwards, the patients had their mandibular complete dentures replaced by a complete fixed denture and the same evaluation protocol was performed after 3 and 6 months. Ohip-Edent responses were analyzed using Wilcoxon's test for repeated measures (α = .05) and Kinesiographic data using the Student´s t test (α = .05). Results: The Ohip-Edent showed an improvement of general oral health-related quality of life after 3 and 6 months of the treatment with complete fixed dentures. Kinesiographic recordings revealed a significant increase on maximum mandibular movements of vertical opening and no differences for the movement of the maxillary complete denture on chewing after treatment with complete fixed dentures was observed. Conclusion: the installation of complete fixed dentures improved the OHQOL and changed mandibular movements, with increases in vertical amplitude of maximal opening.
Resumo:
The contemporary implant dentistry is in constant technological development, improving the oral rehabilitation process of partial or totally edentulous patients. On the other hand, anatomical limitations, such as the maxillary sinus and the mandibular canal in the posterior region of the jaws can limit the implant placement. Furthermore, due to the absence of dental elements, alveolar ridge atrophy is frequently observed. This aspect represents a loss either in quantity or quality of the bone tissue available for the dental implant rehabilitation. To make possible the dental implant rehabilitation even in adverse conditions, some solutions have been considered, such as the use of short implants (≤ 10 mm length) and/or small diameter implants (2,8; 3,3 and 3,5 mm width). The aim of this study is to present a literature review considering the use of short implants in oral rehabilitation, presenting the currently view of the matter. Based on the literature review, the use of short implants produced similar clinical success to conventional implants (greater than 10 mm in length). Therefore, its use can be considered a viable alternative, where anatomical limitations are present.
Resumo:
The continuing advances in technology, dental materials and equipment have contributed significantly to improve the level of esthetic dentistry today. Among these innovations, development of pure ceramic restorations has evolved to give different alternatives. Dental ceramics have presented a rapidly technological changing to improve mechanical and optical properties. Currently there are several systems of metal free ceramics with excellent mechanical and optical properties, for making crowns and plurals. These modern systems are presented with various compositions and different preparation techniques, making these more versatile. Within this perspective, the dental market offers a huge range of new indirect and metal-free materials for prostheses, providing new options, plus also new questions to decide among the available alternatives. The aim of this review is take a view of the different ceramic systems in terms of its composition and different techniques of production.
Resumo:
The demand for cosmetic dentistry, including teeth whitening, has increased in recent years. The home teeth whitening and in-office, are widely used in dental practice. The mechanism by which it works is by oxidation of the chromogenic existing tooth structure. This is an effective and minimally invasive procedure that achieves tooth lighten the color, however, may cause alterations in the enamel surface, such as a dental permeability increase. Another effect caused by this procedure is tooth sensitivity, being the most common side effect, up to 65% of individuals have had a secondary effect at least once during treatment. This sensitivity and gingival irritation caused by bleaching may vary depending on the patient and used bleaching product
Resumo:
The possibilities of treatment with dental implants have revolutionized the field of oral rehabilitation in recent years, bringing a number of advantages over conventional prostheses. For years, a surgical protocol was followed that called for maintaining the implant without load for a certain period for osseointegration, but experimental studies have shown that immediate loading of implants also leads to the formation of peri-implant bone tissue along the time, similarly to that observed for conventionally loaded implants. This study aimed to conduct a literature review regarding the use of this alternative rehabilitation with single implants. The immediate loading of single-tooth replacements is presented as an excellent treatment alternative.
Resumo:
As an alternative to improve the adaptation of prefabricated posts in flared canals and weakened roots, the option is for relining prefabricated pin, known as a technique of anatomical post. This technique, which can be made with composite resin increases the adjustment post to the walls of the canal and reduces the cementing line, causing the retaining post is less dependent on the mechanical properties of the cementing agent. This article aims to provide an overview of anatomical posts, specifically in the last two decades, based on studies extracted from Scielo, Scopus and Pubmed, referring to the following terms of MeSH Data Base: custom made fiber post, indirect fiber glass posts, root canal therapy and post and core tecnique. According to the literature review in this article, it can be concluded that this technique has been used by several authors and has been shown effective and promising, it creates an individualized retainer with better adaptation and decreased mechanical imbrication cementing line .
Resumo:
Periodontitis is a chronic inflammatory disease that results in the destruction of teeth and their supporting tissues with subsequent tooth loss. The replacement of missing teeth for implant-supported restorations has proven to be a highly predictable treatment method with good long-term prognosis. However, some consequences of tooth loss prevents dental implant placement in an ideal position, where regenerative procedures are necessary for this type of rehabilitation. Less invasive procedures such as conventional prosthesis emerge as a therapeutic option in cases where there is enough bone structure for implants and patient´s non-acceptance for invasive procedures. Thus, this paper aims to present the resolution of rehabilitation through a noninvasive and multidisciplinary treatment. One female patient referred to the clinic presented maladaptive bilateral mandibular fixed prostheses, endodontic lesions, gingival recession, and root sensitivity. For proper resolution of this case, an association among osseointegrated implants, fixed partial prosthesis, tooth extraction, and aesthetic periodontal procedures with the use of subepithelial connective tissue graft was proposed. After two years, the patient shows excellent aesthetics and chewing. Within the limits of this scenario, this paper discusses the various factors that may affect the choice of a particular treatment modality for the rehabilitation of edentulous single spaces.
Resumo:
This report shows the resolution of a case study whose aim was promote the aesthetic and functional rehabilitation of upper left hemi-arch over endosseous and needle implant prostheses. To improve the position of the needle implants, we performed the bucco-palatal bending of needles splinting them with composite resin; we removed the screwed implant prosthesis in the regions of the premolars (24 and 25) and molar (26). The mini-abutments of the last two implants were replaced, and in the first premolar and canine, we used cemented abutments due to implant angulation having planned soldering because of implant size and contact with one needle implant that could interfere with intimate contact bone/implant damaging biomechanics. Pick-up impressions were performed with an open tray, using a retractor cord in the needle implants and respective transfer copings. Therefore, models were related on semi-adjustable articulator after a face-bow recording and interocclusal indexes. After working cast fabrication and try-in of infra-structures, these were adjusted and related into the articulator again. Then, after ceramic build-up, adjustments, finishing, and torque, chemically-activated resin cement was applied on units 21 to 24. At the end of the case, we concluded that a good aesthetic and functional rehabilitation depends on thorough knowledge of techniques for each clinical situation.
Resumo:
Osseointegration involves a cascade of biological events, which can be accelerated by modifying the micro and/or nanometric topography of dental implant surfaces. Considering that different treatment types modify the titanium surface giving it a more pronounced rough topography, and physicochemical changes that appear to positively influence the osseointegration process, a literature review was made on the main types of surface treatments and their influence on the biological and cellular aspects of osseointegration, with publications dating from 1969 until the present moment. Although the precise role of the implant surface on the osseointegration of dental implants is not completely clear, the specific effects of implant surface on bone regeneration, initial kinetics, and evolution of mechanical properties have shown to be quite promising. Thus, based on dental implant surface modifications, osseointegration can be defined as a process by which rigid asymptomatic fixation of an alloplastic material can be achieved and kept in close contact with bone tissue, being resistant to early and late functional loads. This process can be modulated by an appropriate treatment of the alloplastic material surface.
Resumo:
Objetive: Evaluate the deformations caused in the cutting edges in the K-file #25 (LK), subjected to pre-beinding of the apcial third using the following methods: finder-bending, cotton-pliers bendin and Flexobend, observed under scanning electron microscopy (SEM). Material and methods: Forty-eight LK#25 were divides into 4 groups (n=12); G1, control; G2, finger-bending; G3, cotton-plier bending, G4, Flexobend. The curvature was standardized in the apical segment of the file at 2 mm of D!. Was constructed a model of acrylic resin that correspond to a canal of 20º of curvature. The files were examined under SEM (260X). Data were analyzed using Fisher´s statistical test with a significance level of 5%. Results: The images showed no alterations in the LK, similar to G3, with no statistical difference. G3 and G4 were statistically different form the other groups (p<0.05). Conclusions: the finger-bending method to curve apical third of LK #25 did not alter the cutting edges, the cotton-pliers bending and Flexobend did alter the cutting edges of the files (AU)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The purpose of this study was to evaluate the macroscopy and microstructure of a double setting alpha-tricalcium phosphate bone cement sphere provided with interconnection channels (alpha-TCP-i), as well as the integration of the implant with the rabbits' orbital tissue, through macroscopic analysis and histopathology. The external and internal surfaces of the alpha-TCP-i were evaluated macroscopically and by electron microscopy. Twelve New Zealand rabbits received 12mm implants of alpha-TCP-i following enucleation of the left eye. The clinical assessment was undertaken daily during the first 15 days, followed by fortnightly assessment until the end of the study period. For the morphological analysis, exenteration was performed in 3 animals per experimental period (15, 45, 90 and 180 days). The external and internal surfaces of the implant appeared solid, smooth and compact, with six channels which interconnected centrally. The micro-architecture was characterized by the formation of columns of hexagonal crystals. No signs of infection, exposure, dehiscence of sutures or extrusion of the implant were noted in any of the animals during the entire period of the study. The morphological evaluation demonstrated the presence of a thin capsule around the implant, from whence appeared fibro-vascular projections, which penetrated it through the interconnecting channels. In the first days after the insertion of the implant, an intense inflammatory reaction was noted. At 180 days, however, there were no signs of inflammation. The alpha-tricalcium phosphate cement implant was well tolerated in this rabbit model and appeared to be relatively inert with some fibrovascular ingrowth through the large channels.
Resumo:
In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.
Resumo:
Pós-graduação em Ciência Odontólogica - FOA