995 resultados para Implantation ionique


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To study the factors associated with choice of therapy and prognosis in octogenarians with severe symptomatic aortic stenosis (AS). STUDY DESIGN Prospective, observational, multicenter registry. Centralized follow-up included survival status and, if possible, mode of death and Katz index. SETTING Transnational registry in Spain. SUBJECTS We included 928 patients aged ≥80 years with severe symptomatic AS. INTERVENTIONS Aortic-valve replacement (AVR), transcatheter aortic-valve implantation (TAVI) or conservative therapy. MAIN OUTCOME MEASURES All-cause death. RESULTS Mean age was 84.2 ± 3.5 years, and only 49.0% were independent (Katz index A). The most frequent planned management was conservative therapy in 423 (46%) patients, followed by TAVI in 261 (28%) and AVR in 244 (26%). The main reason against recommending AVR in 684 patients was high surgical risk [322 (47.1%)], other medical motives [193 (28.2%)], patient refusal [134 (19.6%)] and family refusal in the case of incompetent patients [35 (5.1%)]. The mean time from treatment decision to AVR was 4.8 ± 4.6 months and to TAVI 2.1 ± 3.2 months, P < 0.001. During follow-up (11.2-38.9 months), 357 patients (38.5%) died. Survival rates at 6, 12, 18 and 24 months were 81.8%, 72.6%, 64.1% and 57.3%, respectively. Planned intervention, adjusted for multiple propensity score, was associated with lower mortality when compared with planned conservative treatment: TAVI Hazard ratio (HR) 0.68 (95% confidence interval [CI] 0.49-0.93; P = 0.016) and AVR HR 0.56 (95% CI 0.39-0.8; P = 0.002). CONCLUSION Octogenarians with symptomatic severe AS are frequently managed conservatively. Planned conservative management is associated with a poor prognosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 49-year-old woman, without known cardiovascular risk factors. Hoarseness of voice caused by a paralysis of left vocal cord. She was admitted to hospital because of acute coronary syndrome, associated to resuscitated cardiac arrest (asystolia documented) without later neurology sequels. Physical examination was anodyne. Echocardiographic study demonstrated a compatible image with a large left sinus of Valsalva aneurysm (SVA) (Panel A) and mild aortic regurgitation. Cardiac catheterization confirmed the presence of left SVA (Panel B) that produced extrinsic compression of the left main coronary artery (Panels C and D). Repair surgery was made by means of closing the aneurysmal orifice with a patch of dacron. Intra-operatory echocardiographic control study found severe aortic regurgitation, so valvular replacement with 19 mm mechanical prosthesis and extension of the valve annulus with patch of dacron was performed, associated with bypass with safena vein graft to left coronary artery. SVA is a very infrequent cardiac anomaly, generally with silent clinical course until it ruptures. Myocardial ischaemia caused by coronary artery compression is unusual. We described the case of a patient diagnosed of left SVA, whose initial clinical manifestation was the appearance of resuscitated sudden cardiac death in the context of an acute coronary syndrome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Popliteal pseudoaneurysm is a rare but important complication of knee arthroplasties. To our knowledge, this complication has not been reported previously in the literature after unicompartmental knee arthroplasty. Apart from intraoperatively caused arterial injuries, obese patients and other previous cardiovascular diseases may be potential factors of risks for pseudoaneurysm in knee surgeries. As it is an uncommon complication and it has inconspicuous symptoms, both diagnosis and treatment can be delayed. This means that a high level of suspicion is necessary to prevent serious complications derived from pseudoaneurysms. LEVEL OF EVIDENCE Level IV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this experimental study is to evaluate the feasibility and the outcome of total endovascular stent implantation in the aortic arch. Indications for this operation-technique would be acute or chronic dissection of the aortic arch (non-A-non-B dissection) or type B dissection with retrograde extension. Four pigs were canulated via the distal abdominal aorta and a retrograde placement of a Djumbodis arch stent (4-9 cm) was controlled by using intravascular ultrasound and intracardiac ultrasound by the inferior cava vein and under radioscopic control. Cerebral perfusion, by using a flow meter placed on one prepared carotid artery, were controlled before, immediate post-procedural (<1 min), and in the early follow-up after aortic arch stent implantation. During the implantation process, especially during balloon inflation and deflation, mean carotid perfusion decreases slightly. A reactive increase of carotid perfusion after stent placements indicates transitory cerebral hypo-perfusion. Non-covered aortic arch stent implantation is technically feasible and could be a potential treatment option in otherwise inoperable arch dissections. The time required for balloon inflation and deflation causes an important risk of cerebral ischemia. The latter can be reduced by transaxillary perfusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: In patients with lateral osteoarthritis of the knee, use of external unicompartmental knee arthroplasty it is a well known surgical alternative, used by the minor trauma involved, short hospital stay and rapid recovery. The purpose of this study is to show the clinical outcomes to short-medium term of patients undergoing this procedure. Methods: we describe the technique used and the peculiarities of the prosthesis (A Mobile-bearing lateral unicompartmental knee replacement, Oxford Domed ®). This is an observational retrospective longitudinal study, of 15 arthroplasties performed in 13 women and 2 men, between 2010 and 2013, with a mean age of 60’7 years, with a diagnosis of lateral osteoarthritis of the knee, without involvement of the medial or patellofemoral compartment and cruciate ligaments functionally intact, with a mean follow up of 25 months. All patients complete the Oxford Knee Score and Visual Analog Scale (VAS) during the study. Results: The results are favorable, with an improvement of 6.60 points on the EVA, 3.73 for 1 in the postoperatory funcionality, the OKS very satisfactory with an average of 38 points over 50 and without any postoperative function surgical revision. Anserine tendinitis was observed in 20% of cases. Conclusions: The benefits of this surgery against their alternatives are assessed, and their potential drawbacks. External unicompartmental knee arthroplasty is an effective alternative in cases of knee osteoarthritis of the lateral compartment with no other associated injuries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The purpose of the present study is to translate and validate the "Hip and Knee Outcomes Questionnaire", developed in English, into Spanish. The 'Hip and Knee Outcomes Questionnaire is a questionnaire planned to evaluate the impact in quality of life of any problem related to the human musculoskeletal system. 10 scientific associations developed it. METHODS The questionnaire underwent a validated translation/retro-translation process. Patients undergoing primary knee arthroplasty, before and six months postoperative, tested the final version in Spanish. Psychometric properties of feasibility, reliability, validity and sensitivity to change were assessed. Convergent validity with SF-36 and WOMAC questionnaires was evaluated. RESULTS 316 patients were included. Feasibility: a high number of missing items in questions 3, 4 and 5 were observed. The number of patients with a missing item was 171 (51.35%) in the preoperative visit and 139 (44.0%) at the postoperative. Internal validity: revision of coefficients in the item-rest correlation recommended removing question 6 during the preoperative visit (coefficient <0.20). Convergent validity: coefficients of correlation with WOMAC and SF-36 scales confirm the questionnaire's validity. Sensitivity to change: statistically significant differences were found between the mean scores of the first visit compared to the postoperative. CONCLUSION The proposed translation to Spanish of the 'Hip and Knee Questionnaire' is found to be reliable, valid and sensible to changes produced at the clinical practice of patients undergoing primary knee arthroplasty. However, some changes at the completion instructions are recommended. LEVEL OF EVIDENCE Level I. Prognostic study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Total knee replacement (TKR) is an operation that has radically improved the quality of life of millions of people during the last decades. However, some technical details, concerning the surgical procedure, are still a matter of a strong debate. In this review of the literature, we have included the best evidence available of the last decade, related to TKR surgery like the use of tourniquet during operation, patellar resufacing, all-polyethilene tibial component, cemented or cementless fixation, mobile bearings, or posterior-stabilized versus cruciate-retaining prosthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: Assess the clinical utility of plain radiography in the first postoperative outpatient visit after total knee arthroplasty. Patients and Methods: 200 patients which underwent a total knee arthroplasty from January to May 2012 were analyzed retrospectively, they had two previous control radiographs at hospital discharge and two more at 4-6 weeks after surgery, which were compared, seeking for radiographics signs that would induce a therapeutic changes in the patient’s clinical course. Results: No radiographics signs were observed in the cases studied in the first postoperative visit one month after the surgery, consequently the patient’s treatment plan had no change. Discussion: Our results support those of other authors who have recognized the benefits of reducing the number of postoperative radiographs, improve the cost effectiveness of outpatients care and avoid an extra damage to the patient’s health. We believe that repeated use of serial radiographs in outpatient is simply a custom that has become law, to calm down the patient, and his surgeon, with no scientific evidence to support it use. Conclusions: Our results suggest that the plain AP and L radiographic projection at the first visit, one month later after a TKA, does not provide any clinic information, adds substantial cost to the heath-care system and unnecessary harms the patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To study the factors associated with choice of therapy and prognosis in octogenarians with severe symptomatic aortic stenosis (AS). STUDY DESIGN Prospective, observational, multicenter registry. Centralized follow-up included survival status and, if possible, mode of death and Katz index. SETTING Transnational registry in Spain. SUBJECTS We included 928 patients aged ≥80 years with severe symptomatic AS. INTERVENTIONS Aortic-valve replacement (AVR), transcatheter aortic-valve implantation (TAVI) or conservative therapy. MAIN OUTCOME MEASURES All-cause death. RESULTS Mean age was 84.2 ± 3.5 years, and only 49.0% were independent (Katz index A). The most frequent planned management was conservative therapy in 423 (46%) patients, followed by TAVI in 261 (28%) and AVR in 244 (26%). The main reason against recommending AVR in 684 patients was high surgical risk [322 (47.1%)], other medical motives [193 (28.2%)], patient refusal [134 (19.6%)] and family refusal in the case of incompetent patients [35 (5.1%)]. The mean time from treatment decision to AVR was 4.8 ± 4.6 months and to TAVI 2.1 ± 3.2 months, P < 0.001. During follow-up (11.2-38.9 months), 357 patients (38.5%) died. Survival rates at 6, 12, 18 and 24 months were 81.8%, 72.6%, 64.1% and 57.3%, respectively. Planned intervention, adjusted for multiple propensity score, was associated with lower mortality when compared with planned conservative treatment: TAVI Hazard ratio (HR) 0.68 (95% confidence interval [CI] 0.49-0.93; P = 0.016) and AVR HR 0.56 (95% CI 0.39-0.8; P = 0.002). CONCLUSION Octogenarians with symptomatic severe AS are frequently managed conservatively. Planned conservative management is associated with a poor prognosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The use of remote follow-up (RF) of people with pacemakers (PM) is limited in comparison to the hospital modality (HS), being still poor the scientific evidence that shows their comparative effectiveness. The aim of this study was to compare the quality of life in individuals with different modalities of follow-up. METHODS Controlled, not randomized nor masked clinical trial, with data collection at pre and post-implantation of pacemakers during the 6 months follow-up. All patients over 18 years-old who were implanted a PM during the study period were selected (n = 83), and they were assigned to RF (n = 30) or HF (n = 53) groups according to their personal characteristics and patient's preferences. Baseline characteristics and number of visits to the hospital were analysed, the EuroQol-5D (EQ5D) questionnaire was administered to evaluate the health-related quality of life, and Duke Activity Status Index (DASI) to assess the functional capacity. RESULTS There were no significant differences between both groups in relation to the baseline analysis, EQ5D (RF:0.7299; HF:0.6769) and DASI (RF:21.41; HF:19.99). At 6 months the quality of life was improved in both groups (EQ5D RF:0.8613; HF:0.8175; p = 0,439) still without significant differences between them. DASI score was similar to baseline (20.51 vs 21.80). RF group performed less transmissions/visits per patient (1.57) than hospital group (1.96; relative reduction 31%; p = 0.015). CONCLUSIONS Remote follow-up of people with pacemakers might be considered as an equivalent option to the hospital follow-up in relation to the quality of life and it reduces the number of hospital visits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The Contegra bioprosthesis (valved heterologous bovine jugular vein) is used for reconstruction of the right ventricular outflow tract (RVOT) in congenital heart malformations and pulmonary valve replacement in different settings. Compared to pulmonary homografts, the Contegra conduit is readily available 'on the shelf'. So far, its use was mainly described in children. The aim of this study is to evaluate the feasibility and the outcome of Contegra graft implantation in the adult. METHODS: Between November 1999 and December 2007, a total of 32 Contegra grafts were implanted in 31 patients (24 men and 7 women), with a mean age of 35.7+/-10.5 years (range 18-54 years). All operations have been completed through median sternotomy with cardiopulmonary bypass. Indications included: Ross procedure for aortic valve disease (n=22); re-operation of corrected Fallot-tetralogy (n=5); isolated pulmonary valve disease (n=2); re-operation of double outlet right ventricle (DORV) (n=1); pulmonary stenosis in congenital dilated cardiomyopathy (DCM) (n=1). Conduit sizes included 22 mm (n=31), 20 mm (n=1). RESULTS: There was no hospital mortality and no valved conduit related early morbidity. In the median follow-up of 38 months (range 1-99 months) of 28 patients there was one late death, not conduit related (total mortality 3.6%). Re-operation for symptomatic graft stenosis was realised in two patients, 7 and 16 months after primo-implantation, corresponding to graft related late morbidity of 7.1%. CONCLUSIONS: In this small review of 32 operations using the Contegra graft for RVOT reconstruction in adult cardiac surgery for different indications, we observed good postoperative mid-term results concerning conduit function. Mean transpulmonary pressure gradients remain low (13.3+/-6.6 mmHg postoperative, 14.5+/-7.9 mmHg at follow-up). The use of the Contegra graft seems to be a good alternative to the homograft with low operative mortality and morbidity. Long-term outcome data are not available and further investigations must be performed to evaluate results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is an ever-growing trend towards less-invasive procedures in all fields of medicine. We designed an animal study to prove the concept that trans-apical aortic valve replacement from an incision within the umbilicus through a single channel for instruments is feasible, which would be a major leap towards no-scar cardiac surgery. In three adult pigs, after creating a single 3-cm incision at a place where the human umbilicus would be, we introduced a 30F sheath through a tunnel created by an endoscopic vein-harvesting device up to the cardiac apex, through it and up to the left ventricle simulating the approach for trans-apical aortic valve replacement. We used a standard Amplatz nitinol occluder to seal the defect in ventricle wall later. The animals were followed up for 1h. Blood loss was minimal, and no tamponade occurred in any of the animals. In addition, we performed a test with water column static pressure to evaluate the impact of preclotting on the sealing properties of the occluders: 1 min flow-through was 2860+/-176 ml for the standard occluders and 348+/-56 ml for preclotted occluders (p<0.001).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Painful total hip replacement remains a challenging problem because of the large amount of possible diagnoses. We report about a 64-year-old female patient who was misdiagnosed during 4 years as psychiatric. She suffered of excruciating left retrotrochanteric pain after the implantation of a cementless total hip replacement and revision because of recurrent hip dislocations. Walking was limited to short distances using two crutches. The work-up at this time included the usual diagnoses and remained unsuccessful. No loosening, infection or malposition of the prosthesis could be found, and she had no neurologic deficits in her operated leg. An MRI was obtained to visualize the retrotrochanteric soft tissues and showed a tight scar surrounding the sciatic nerve, which was also compressed by an adjacent lipoma. Therefore, she was reoperated on to remove the lipoma and the scar tissue around the sciatic nerve. To decrease the risk of recurrent scarring around the sciatic nerve, an adhesion barrier was applied before closure. One year after the operation, the patient has no neurologic deficit, no more pain and is able to walk unlimited distances without crutches. Scar tissue around the sciatic nerve is frequently observed during revision surgery. However, we feel that sciatic nerve entrapment by scar tissue should be a part of the differential diagnosis of painful THR. MRI may be a useful tool to achieve this diagnosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: IOL centration and stability after cataract surgery is of high interest for cataract surgeons and IOL-producing companies. We present a new imaging software to evaluate the centration of the rhexis and the centration of the IOL after cataract surgery.Methods: We developed, in collaboration with the Biomedical Imaging Group (BIG), EPFL, Lausanne, a new working tool in order to assess precisely outcomes after IOL-implantation, such as ideal capsulorhexis and IOL-centration. The software is a plug-in of ImageJ, a general-purpose image processing and image-analysis package. The specifications of this software are: evaluation of the rhexis-centration and evaluation the position of the IOL in the posterior chamber. The end points are to analyze the quality of the centration of a rhexis after cataract surgery, the deformation of the rhexis with capsular bag retraction and the centration of the IOL after implantation.Results: This software delivers tools to interactively measure the distances between limbus, IOL and capsulorhexis and its changes over time. The user is invited to adjust nodes of three radial curves for the limbus, rhexis and the optic of the IOL. The radial distances of the curves are computed to evaluate the IOL implantation. The user is also able to define patterns for ideal capsulorhexis and optimal IOL-centration. We are going to present examples of calculations after cataract surgery.Conclusions: Evaluation of the centration of the rhexis and of the IOL after cataract surgery is an important end point for optimal IOL implantation after cataract surgery. Especially multifocal or accommodative lenses need a precise position in the bag with a good stability over time. This software is able to evaluate these parameters just after the surgery but also its changes over time. The results of these evaluations can lead to an optimizing of surgical procedures and materials.