936 resultados para Implant removal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Recent clinical studies have described maxillary sinus floor augmentation by simply elevating the maxillary sinus membrane without the use of adjunctive grafting materials. Purpose: This experimental study aimed at comparing the histologic outcomes of sinus membrane elevation and simultaneous placement of implants with and without adjunctive autogenous bone grafts. The purpose was also to investigate the role played by the implant surface in osseointegration under such circumstances. Materials and Methods: Four tufted capuchin primates had all upper premolars and the first molar extracted bilaterally. Four months later, the animals underwent maxillary sinus membrane elevation surgery using a replaceable bone window technique. The schneiderian membrane was kept elevated by insertion of two implants (turned and oxidized, Brånemark System®, Nobel Biocare AB, Göteborg, Sweden) in both sinuses. The right sinus was left with no additional treatment, whereas the left sinus was filled with autogenous bone graft. Implant stability was assessed through resonance frequency analysis (Osstell™, Integration Diagnostics AB, Göteborg, Sweden) at installation and at sacrifice. The pattern of bone formation in the experimental sites and related to the different implant surfaces was investigated using fluorochromes. The animals were sacrificed 6 months after the maxillary sinus floor augmentation procedure for histology and histomorphometry (bone-implant contact, bone area in threads, and bone area in rectangle). Results: The results showed no differences between membrane-elevated and grafted sites regarding implant stability, bone-implant contacts, and bone area within and outside implant threads. The oxidized implants exhibited improved integration compared with turned ones as higher values of bone-implant contact and bone area within threads were observed. Conclusions: The amount of augmented bone tissue in the maxillary sinus after sinus membrane elevation with or without adjunctive autogenous bone grafts does not differ after 6 months of healing. New bone is frequently deposited in contact with the schneiderian membrane in coagulum-alone sites, indicating the osteoinductive potential of the membrane. Oxidized implants show a stronger bone tissue response than turned implants in sinus floor augmentation procedures. © 2006 Blackwell Publishing, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This article reports preliminary clinical results of the Speed Master system, a method for immediate loading of implants for the treatment of mandibular edentulism. Materials and Methods: Fifteen patients with edentulous mandibles were consecutively included in the study. Each received 4 implants between the mental foramina placed using the system's surgical guides. Permanent fixed prostheses fabricated over premanufactured titanium bars were attached to the implants on the day of implant placement. The patients were followed for 15 to 27 months (mean, 19 months). Peri-implant tissues were periodically evaluated. Marginal bone loss was monitored with periapical radiographs using a computerized technique. Satisfaction was assessed by means of a questionnaire. Results: The overall implant and prosthetic survival rates were 100%. At the time of the final follow-up visit, mean marginal bone loss was 1.11 mm, and bleeding on probing was not observed. Only 6.7% of the patients reported any discomfort during treatment, and all patients would recommend the procedure to others. Discussion: The immediate loading of implants placed in the edentulous mandible with the Speed Master surgical and prosthetic protocol reduces treatment time and number of surgical procedures in comparison to classic delayed loading protocols. Conclusion: The rehabilitation of the mandible with an immediately delivered occlusally loaded hybrid prosthesis supported by 4 implants does not appear to jeopardize the success of the osseointegration and represents a viable treatment option.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Comparison of the clinical efficacy of 4% articaine in relation to 2% mepivacaine, both with 1:100,000 epinephrine, in the prevention of postoperative pain after lower third molar removal. Study design: Twenty patients underwent removal of bilateral lower third molars under local anesthesia (articaine or mepivacaine) in 2 separate appointments, in a double-blind, randomized, and crossed manner. Objective and subjective parameters were recorded for paired comparison of postoperative courses. Results: Duration of analgesia provided by articaine and mepivacaine was 198.00 ± 25.86, and 125.40 ± 13.96 min, respectively (P = .02), whereas the duration of anesthesia was 273.80 ± 15.94 and 216.85 ± 20.15 min, respectively (P = .06). Both solutions exerted no important effects upon arterial pressure, heart rate, or oxygen saturation (P > .05). Conclusions: Articaine provides a longer period of analgesic effect and a tendency for a longer period of anesthesia as compared to mepivacaine. The presence of a vasoconstrictor agent in local anesthetic solutions does not seem to influence hemodynamic parameters during lower third molar removal in healthy subjects. © 2006 Mosby, Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of teeth-implant, mucosa-supported removable dentures for rehabilitation of partially edentulous patients involves highly complex biomechanical aspects. This type of prosthesis associates 3 kinds of support that react differently to the functional and parafunctional forces developed in the oral cavity. Although the construction of removable partial dentures may seem paradoxical when osseointegrated implants are placed, in some cases, this option is an excellent alternative to solve difficulties related to the anatomic, biologic, psychomotor, and financial conditions of the patient. This article reports on a case in which a teeth-implant, mucosa-supported removable partial denture was the option of choice for a patient with financial and anatomic limitations, having a large structural loss of the residual alveolar ridge caused by trauma by a gunshot injury at the mandible. The 5-year follow-up did not reveal any type of biomechanical or functional problem. Copyright © 2006 by Lippincott Williams and Wilkins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effectiveness of subgingival application of Carisolv™ gel as an adjunctive therapy to scaling and root planing (SRP) on calculus removal compared to conventional instrumentation. Forty-five teeth requiring extraction due to severe periodontal disease were randomized to the following treatments: 1) SRP alone; 2) placebo gel + SRP; 3) Carisolv™ gel + SRP. Either test or placebo gel was applied subgingivally for 1 min and then the root were instrumented until a smooth and calculus-free surface was achieved. Instrumentation time and the number of strokes required were recorded. After extraction, the efficacy of root surface instrumentation was measured by percentage of remaining calculus. There was no statistically significant difference (p>0.05) between the treatment groups regarding either time required for instrumentation or the percentage of residual calculus. The subgingival application of Carisolv™ gel prior to SRP did not provide any additional benefit to root instrumentation compared to scaling and root planing alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to compare the accuracy of two working cast fabrication techniques using strain-gauge analysis. Methods: Two working cast fabrication methods were evaluated. Based on a master model, 20 working casts were fabricated by means of an indirect impression technique using polyether after splinting the square transfer copings with acrylic resin. Specimens were assigned to 2 groups (n=10): Group A (GA): type IV dental stone was poured around the abutment analogs in the conventional way; Group B (GB), the dental stone was poured in two stages. Spacers were used over the abutment analogs (rubber tubes) and type IV dental stone was poured around the abutment analogs in the conventional way. After the stone had hardened completely, the spacers were removed and more stone was inserted in the spaces created. Six strain-gauges (Excel Ltd.), positioned in a cast bar, which was dimensionally accurate (perfect fit) to the master model, recorded the microstrains generated by each specimen. Data were analyzed statistically by the variance analysis (ANOVA) and Tukey's test (α= 5%). Results: The microstrain values (με) were (mean±SD): GA: 263.7±109.07με, and GB: 193.73±78.83με. Conclusion: There was no statistical difference between the two methods studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study carried out an in vitro evaluation and comparison of the occurrence of marginal leakage in bonded restorations using mechanical or chemical-mechanical (Carisolv) removal of carious tissue. For that purpose, 40 extracted decayed human molars were divided into 4 groups: GI (burs + Prime & Bond NT + TPH), GII (Carisolv + Prime & Bond NT + TPH), GIII (burs + SBMP + Z100) and GIV (Carisolv + SBMP + Z100). After accomplishment of the restorations and thermal cycling, the teeth were exposed to dye, sectioned and qualitatively evaluated. The results demonstrated that the system of removal of carious tissue did not influence the results of microleakage at any of the cavity margins. At dentinal margins, use of the Prime & Bond NT + TPH restorative system allowed the occurrence of less microleakage than the SBMP + Z100 system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to survey radiographic measurement estimation in the assessment of dental implant length according to dentists' confidence. A 19-point questionnaire with closed-ended questions was used by two graduate students to interview 69 dentists during a dental implant meeting. Included were 12 questions related to over- and underestimation in three radiographic modalities: panoramic (P), conventional tomography (T), and computerized tomography (CT). The database was analyzed by Epi-Info 6.04 software and the values from two radiographic modalities, P and T, were compared using a chi2 test. The results showed that 38.24% of the dentists' confidence was in the overestimation of measurements in P, 30.56% in T, and 0% in CT. On the other hand, considering the underestimated measurements, the percentages were 47.06% in P, 33.33% in T, and 1.92% in CT. The frequency of under- and overestimation were statistically significant (chi2 = 6.32; P = .0425) between P and T. CT was the radiographic modality with higher measurement precision according to dentists' confidence. In conclusion, the interviewed dentists felt that CT was the best radiographic modality when considering the measurement estimation precision in preoperative dental implant assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this experiment, 18 hybrid steers, from the ages between 16 and 20 months, were submitted to the removal of the penis apical ligament to provoke a penis deviation. After passed 30 days, to be tested, the animals were put together to the females that were in heat. It was verified the formation of the ventral and right lateral penis deviation with incapacity of the copula. The bovines were submitted to the autologous implant from the one following superficial portion tendon from the superficial flexor fingers muscle, on the top of albuginea tunic, replacing the apical penis ligament removed. The material implanted was well tolerated, appearance a few inflammatory cells and formation of the fibrous conjunctive tissue, causing resistant adherence and capacity of sustaining the free penis extremity. The bovines, when were among the females that were in heat, did not show a penis deviation nor sexual behavior modification. The method revealed itself satisfactory and it can be indicated to correct ventral and right lateral penis deviation in bovines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Smear layer removal and collagen fiber exposure may improve periodontal treatment and regeneration. This in vitro study assessed smear layer removal and collagen fiber exposure after tetracycline hydrochloride (TTC) application on root surfaces using scanning electron microscopy (SEM). Methods and Materials: Root cementum was removed with diamond burs followed by scaling and root planning. Four hundred fifty samples were divided into ten groups: a control (saline application) and nine different TTC concentrations were applied at doses of 10, 25, 50, 75, 100, 125, 150, 200, and 250 mg/ml. The TTC application was performed in all groups in three different ways (passive, brushing, and burnishing) and at three different periods of conditioning (1, 2, and 3 minutes). A previously trained, calibrated, and blind examiner evaluated photomicrographs of the samples using Sampaio's index (2005). Statistical analysis was performed using the Kruskal-Wallis' and Dunn's tests. Results: The concentrations of 50 mg/mL and 75 mg/mL applied by burnishing were the most effective in smear layer removal and collagen fiber exposure. Both the passive mode of application (p=0.0001) and 1 minute period of application (p=0.002) were the least effective. Conclusions: The concentrations of 50 mg/mL and 75 mg/mL applied by burnishing during 2 or 3 minutes were the most effective. Clinical Significance: These parameters may be applied in periodontal procedures involving TTC root conditioning to optimize results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate a bone morphogenetic protein (BMP) implant with and without platelet-rich plasma (PRP), which is supposed to accelerate fracture consolidation in the orbit fracture treatment. Methods: Thirty-six white rabbits were subjected to orbital fracture and treated in three groups: BMP implant fracture repair (G1), BMP plus PRP implant fracture repair (G2), and fracture and spontaneous repair (G3). The animals were sacrificed at 7, 30, 90, and 180 days after surgery. A radiology evaluation was carried out on the 7th day after the fracture and at the sacrifice moments. After the animals' death, the orbital content material was removed and prepared for morphological and morphometric analysis. Results: Radiology suggested intramembranous and progressive cavitation and ossification without a reduction in implant size and with signs of calcium deposition; these events were confirmed by histological analysis, which showed a lymphomononuclear inflammatory reaction in G1 and G2, more intense 7 days after surgery and reducing after 30 days. Associating PRP with BMP did not accelerate bone induction. Conclusion: BMP implant promotes bone induction, integration at fracture site, scarce inflammatory reaction, and may be a good alternative in orbit fracture reconstruction. The addition of PRP to the BMP plate did not accelerate the resolution, and its use is not necessary. Copyright © Informa Healthcare USA, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Previous studies have shown that membrane elevation results in predictable bone formation in the maxillary sinus provided that implants can be placed as tent poles. In situations with an extremely thin residual crest which impairs implant placement, it is possible that a space-making device can be used under the sinus membrane to promote bone formation prior to placement of implants. Purpose: The present study was conducted to test the hypothesis that the use of a space-making device for elevation of the sinus membrane will result in predictable bone formation at the maxillary sinus floor to allow placement of dental implants. Materials and Methods: Eight tufted capuchin primates underwent bilateral sinus membrane elevation surgery, and a bioresorbable space-making device, about 6 mm wide and 6 mm in height, was placed below the elevated membrane on the sinus floor. An oxidized implant (Nobel Biocare AB, Gothenburg, Sweden) was installed in the residual bone protruding into the created space at one side while the other side was left without an implant. Four animals were sacrificed after 6 months of healing. The remaining four animals received a second implant in the side with a space-making device only and followed for another 3 months before sacrifice. Implant stability was assessed through resonance frequency analysis (RFA) using the Osstell™ (Osstell AB, Gothenburg, Sweden) at installation, 6 months and 9 months after the first surgery. The bone-implant contact (BIC) and bone area inside the threads (BA) were histometrically evaluated in ground sections. Results: Histologically there were only minor or no signs of bone formation in the sites with a space-making device only. Sites with simultaneous implant placement showed bone formation along the implant surface. Sites with delayed implant placement showed minor or no bone formation and/or formation of a dense fibrous tissue along the apical part of the implant surface. In the latter group the apical part of the implant was not covered with the membrane but protruded into the sinus cavity. Conclusions: The use of a space-making device, with the design used in the present study, does not result in bone formation at the sinus floor. However, membrane elevation and simultaneous placement of the device and an implant does result in bone formation at the implant surface while sites with implants placed 6 months after membrane elevation show only small amounts of bone formation. It is suggested that lack of stabilization of the device and/or a too extensive elevation of the membrane may explain the results. © 2009, Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of oral rehabilitation with immediately loaded fixed implant-supported mandibular prostheses on chewing and swallowing in elderly individuals. Materials and Methods: Fifteen completely edentulous patients aged more than 60 years (10 women and rive men), wearing removable dentures in both arches, had a mandibular denture replaced by an implant-supported prosthesis. All individuals were evaluated before surgery and again 3, 6, and 18 months later with regard to mastication and swallowing conditions. Examinations entailed an interview, evaluation of tactile sensitivity of the face, and observation of food intake, masticatory type, formations of bolus, and pain during mastication. The swallowing evaluation comprised observation of clinical signs related to the oral and pharyngeal stages of swallowing, as well as the presence of oral residue. The findings of different evaluations before and 3, 6, and 18 months after the surgical-prosthetic procedure were statistically compared by analysis of variance for repeated measurements at a significance level of 5%. Results: The questionnaire revealed a reduction in complaints of masticatory and swallowing disturbances, a decreased need for liquid ingestion, and reduced choking and coughing. Clinical evaluations showed improved oral function and bolus propulsion for both solid and paste-consistency foods; pain during mastication was also resolved. Conclusion: Treatment with mandibular implant-supported dentures had positive effects on the clinical aspects of mastication and swallowing in elderly individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Despite the antibacterial properties of dental materials, the survival of residual bacteria under restorations has been demonstrated after incomplete caries removal. The aim of this study was to evaluate the genetic polymorphism of Streptococcus mutans strains isolated from deep dentinal lesions before and three months after incomplete caries removal. Methods: Samples of carious dentin were collected from 33 primary and/or permanent molars before and after indirect pulp treatment and processed for microbiological isolation of mutans streptococci (MS). After three months of the dental treatment, positive cultures for MS were detected in only ten of these teeth. DNA of MS isolates were obtained and subjected to polymerase chain reaction (PCR) for identification of S mutans. The arbitrary primed-PCR method (primer OPA-13) was used to detect the genetic polymorphism of S. mutans strains. Results: Identical or highly related S. mutans genotypes were observed in each tooth, regardless of the collect. Considering each tooth separately, a maximum of nine genotypic patterns were found in each tooth from all the collects. In addition, at least one genotypic pattern was repeated in the three collects. Genetic diversity was observed among the S. mutans isolates, obtained from different teeth after three months of the dental treatment. Conclusions: The persistence of identical genotypic patterns and the genetic similarity among the isolates, from the same tooth in distinct collects, showed the resistance of some S. mutans strains after incomplete caries removal treatment.