871 resultados para Impaired Awareness


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Contrast sensitivity (CS) provides important information on visual function. This study aimed to assess differences in clinical expediency of the CS increment-matched new back-lit and original paper versions of the Melbourne Edge Test (MET) to determine the CS of the visually impaired. Methods: The back-lit and paper MET were administered to 75 visually impaired subjects (28-97 years). Two versions of the back-lit MET acetates were used to match the CS increments with the paper-based MET. Measures of CS were repeated after 30 min and again in the presence of a focal light source directed onto the MET. Visual acuity was measured with a Bailey-Lovie chart and subjects rated how much difficulty they had with face and vehicle recognition. Results: The back-lit MET gave a significantly higher CS than the paper-based version (14.2 ± 4.1 dB vs 11.3 ± 4.3 dB, p < 0.001). A significantly higher reading resulted with repetition of the paper-based MET (by 1.0 ± 1.7 dB, p < 0.001), but this was not evident with the back-lit MET (by 0.1 ± 1.4 dB, p = 0.53). The MET readings were increased by a focal light source, in both the back-lit (by 0.3 ± 0.81, p < 0.01) and paper-based (1.2 ± 1.7, p < 0.001) versions. CS as measured by the back-lit and paper-based versions of the MET was significantly correlated to patients' perceived ability to recognise faces (r = 0.71, r = 0.85 respectively; p < 0.001) and vehicles (r = 0.67, r = 0.82 respectively; p < 0.001), and with distance visual acuity (both r =-0.64; p < 0.001). Conclusions: The CS increment-matched back-lit MET gives higher CS values than the old paper-based test by approximately 3 dB and is more repeatable and less affected by external light sources. Clinically, the MET score provides information on patient difficulties with visual tasks, such as recognising faces. © 2005 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To examine the use of real-time, generic edge detection, image processing techniques to enhance the television viewing of the visually impaired. Design: Prospective, clinical experimental study. Method: One hundred and two sequential visually impaired (average age 73.8 ± 14.8 years; 59% female) in a single center optimized a dynamic television image with respect to edge detection filter (Prewitt, Sobel, or the two combined), color (red, green, blue, or white), and intensity (one to 15 times) of the overlaid edges. They then rated the original television footage compared with a black-and-white image displaying the edges detected and the original television image with the detected edges overlaid in the chosen color and at the intensity selected. Footage of news, an advertisement, and the end of program credits were subjectively assessed in a random order. Results: A Prewitt filter was preferred (44%) compared with the Sobel filter (27%) or a combination of the two (28%). Green and white were equally popular for displaying the detected edges (32%), with blue (22%) and red (14%) less so. The average preferred edge intensity was 3.5 ± 1.7 times. The image-enhanced television was significantly preferred to the original (P < .001), which in turn was preferred to viewing the detected edges alone (P < .001) for each of the footage clips. Preference was not dependent on the condition causing visual impairment. Seventy percent were definitely willing to buy a set-top box that could achieve these effects for a reasonable price. Conclusions: Simple generic edge detection image enhancement options can be performed on television in real-time and significantly enhance the viewing of the visually impaired. © 2007 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

here is an increasing number of reports of propylene glycol (PG) toxicity in the literature, regardless of its inclusion on the Generally Recognized as Safe List (GRAS).1 PG is an excipient used in many medications as a solvent for water-insoluble drugs. Polypharmacy may increase PG exposure in vulnerable PICU patients who may accumulate PG due to compromised liver and renal function. The study aim was to quantify PG intake in PICU patients and attitudes of clinicians towards PG. Method A snapshot of 50 PICU patients oral or intravenous medication intake was collected. Other data collected included age, weight, diagnosis, lactate levels and renal function. Manufacturers were contacted for PG content and then converted to mg/kg. Excipients in formulations that compete with the PG metabolism pathway were recorded. The Intensivists' opinions on PG intake was sought via e-survey. Results The 50 patients were prescribed 62 drugs and 83 formulations, 43/83 (52%) were parenteral formulations. Median weight of the patients was 5.5 kg (range 2–50 kg), ages ranged from 1 day to 13 years of age. Eleven of the patients were classed as renally impaired (defined as 1.5 times the baseline creatinine). Sixteen formulations contained PG, 2/16 were parenteral, 6/16 unlicensed preparations. Thirty-eight patients received at least one prescription containing PG and 29/38 of these patients were receiving formulations that contained excipients that may have competed with the metabolic pathways of PG. PG intake ranged from 0.002 mg/kg/day to 250 mg/kg/day. Total intake was inconclusive for 2 patients due to a of lack of availability of information from the manufacturer; these formulations were licensed but used in for off-label indications. Five commonly used formulations contributed to higher intakes of PG, namely co-trimoxazole, dexamethasone, potassium chloride, dipyridamole and phenobarbitone. Lactate levels were difficult to interpret due to the underlying conditions of the patients. One of the sixteen intensivist was aware of PG content in drugs, 16/16 would actively change therapy if intake was above European Medicines Agency recommendations. Conclusions Certain formulations used on PICU can considerably increase PG exposure to patients. Due to a lack of awareness of PG content, these should be highlighted to the clinician to assist with making informed decisions regarding risks versus benefits in continuing that drug, route of administration or formulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Prescribing magnification is typically based on distance or near visual acuity. this presumes a constant minimum angle of visual resolution with working distance and therefore enlargement of an object moved to a shorter working distance (relative distance enlargement). this study examines this premise in a visually impaired population. methods: distance letter visual acuity was measured prospectively for 380 low vision patients (distance visual acuity between 0.3 and 2.1 logmar) over the age of 57 years, along with near word visual acuity at an appropriate distance for near lens additions from +4 d to +20 D. demographic information, the disease causing low vision, contrast sensitivity, visual field and psychological status were also recorded. results: distance letter acuity was significantly related to (r = 0.84) but on average 0.1 ± 0.2 logmar better (1 ± 2 lines on a logmar chart) than near word acuity at 25 cm with a +4 d lens addition. in 39. 8 per cent of patients, near word acuity was more than 0.1 logmar worse than distance letter acuity. in 11.0 per cent of subjects, near visual acuity was more than 0.1 logmar better than distance letter acuity. the group with near word acuity worse than distance letter acuity also had lower contrast sensitivity. the group with near word acuity better than distance letter acuity was less likely to have age-Related macular degeneration. smaller print size could be read by reducing working distance (achieved by using higher near lens additions) in 86. 1 per cent, although not by as much as predicted by geometric progression in 14. 5 per cent. discussion: although distance letter and near word acuity are highly related, they are on average 1 logmar line different and this varies significantly between individuals. near word acuity did not increase linearly with relative distance enlargement in approximately one in seven visually impaired, suggesting that the measurement of visual resolution over a range of working distances will assist appropriate prescribing of magnification aids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an increasing number of reports of propylene glycol (PG) toxicity in the literature, regardless of its inclusion on the Generally Recognized as Safe List (GRAS).1 PG is an excipient used in many medications as a solvent for water-insoluble drugs. Polypharmacy may increase PG exposure in vulnerable PICU patients who may accumulate PG due to compromised liver and renal function. The study aim was to quantify PG intake in PICU patients and attitudes of clinicians towards PG. Method A snapshot of 50 PICU patients oral or intravenous medication intake was collected. Other data collected included age, weight, diagnosis, lactate levels and renal function. Manufacturers were contacted for PG content and then converted to mg/kg. Excipients in formulations that compete with the PG metabolism pathway were recorded. The Intensivists' opinions on PG intake was sought via e-survey. Results The 50 patients were prescribed 62 drugs and 83 formulations, 43/83 (52%) were parenteral formulations. Median weight of the patients was 5.5 kg (range 2–50 kg), ages ranged from 1 day to 13 years of age. Eleven of the patients were classed as renally impaired (defined as 1.5 times the baseline creatinine). Sixteen formulations contained PG, 2/16 were parenteral, 6/16 unlicensed preparations. Thirty-eight patients received at least one prescription containing PG and 29/38 of these patients were receiving formulations that contained excipients that may have competed with the metabolic pathways of PG. PG intake ranged from 0.002 mg/kg/day to 250 mg/kg/day. Total intake was inconclusive for 2 patients due to a of lack of availability of information from the manufacturer; these formulations were licensed but used in for off-label indications. Five commonly used formulations contributed to higher intakes of PG, namely co-trimoxazole, dexamethasone, potassium chloride, dipyridamole and phenobarbitone. Lactate levels were difficult to interpret due to the underlying conditions of the patients. One of the sixteen intensivist was aware of PG content in drugs, 16/16 would actively change therapy if intake was above European Medicines Agency recommendations. Conclusions Certain formulations used on PICU can considerably increase PG exposure to patients. Due to a lack of awareness of PG content, these should be highlighted to the clinician to assist with making informed decisions regarding risks versus benefits in continuing that drug, route of administration or formulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research study illustrates the importance of sustainable purchasing practices for organizations in the U.S. distribution industry and answers several important questions: what is the current awareness of U.S. organizations regarding sustainable purchasing practices; to what extent are U.S. organizations evaluating, selecting, and retaining suppliers based upon sustainable purchasing practices; and to what extent are sustainable purchasing practices being implemented by the U.S. organizations under study? With an ever increasing global economy, is it critically important for organizations to put in place sustainability practices; the biggest impact organizations can make is often in an organization’s purchasing department. The researcher begins by explaining the reasoning for conducting the research, and then builds the readers’ understanding of sustainability in a supply chain environment. It then moves to the subject of how sustainable purchasing can be an advantageous method for bringing about “triple bottom line” savings to an organization. This section is followed by the researcher’s methodology and ending results for a survey conducted to examine the current awareness and implementation of sustainable purchasing practices among U.S. plumbing, heating, cooling and piping (PHCP) distribution firms who participated in the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To develop a short, enhanced functional ability Quality of Vision (faVIQ) instrument based on previous questionnaires employing comprehensive modern statistical techniques to ensure the use of an appropriate response scale, items and scoring of the visual related difficulties experienced by patients with visual impairment. METHODS Items in current quality-of-life questionnaires for the visually impaired were refined by a multi-professional group and visually impaired focus groups. The resulting 76 items were completed by 293 visually impaired patients with stable vision on two occasions separated by a month. The faVIQ scores of 75 patients with no ocular pathology were compared to 75 age and gender matched patients with visual im pairm ent. RESULTS Rasch analysis reduced the faVIQ items to 27. Correlation to standard visual metrics was moderate (r=0.32-0.46) and to the NEI-VFQ was 0.48. The faVIQ was able to clearly discriminate between age and gender matched populations with no ocular pathology and visual impairment with an index of 0.983 and 95% sensitivity and 95% specificity using a cut off of 29. CONCLUSION The faVIQ allows sensitive assessm ent of quality-of-life in the visually im paired and should support studies which evaluate the effectiveness of low vision rehabilitation services. © Copyright International Journal of Ophthalmology Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnification can be provided to assist those with visual impairment to make the best use of remaining vision. Electronic transverse magnification of an object was first conceived for use in low vision in the late 1950s, but has developed slowly and is not extensively prescribed because of its relatively high cost and lack of portability. Electronic devices providing transverse magnification have been termed closed-circuit televisions (CCTVs) because of the direct cable link between the camera imaging system and monitor viewing system, but this description generally refers to surveillance devices and does not indicate the provision of features such as magnification and contrast enhancement. Therefore, the term Electronic Vision Enhancement Systems (EVES) is proposed to better distinguish and describe such devices. This paper reviews current knowledge on EVES for the visually impaired in terms of: classification; hardware and software (development of technology, magnification and field-of-view, contrast and image enhancement); user aspects (users and usage, reading speed and duration, and training); and potential future development of EVES. © 2003 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To examine whether objective performance of near tasks is improved with various electronic vision enhancement systems (EVES) compared with the subject's own optical magnifier. DESIGN: Experimental study, randomized, within-patient design. METHODS: This was a prospective study, conducted in a hospital ophthalmology low-vision clinic. The patient population comprised 70 sequential visually impaired subjects. The magnifying devices examined were: patient's optimum optical magnifier; magnification and field-of-view matched mouse EVES with monitor or head-mounted display (HMD) viewing; and stand EVES with monitor viewing. The tasks performed were: reading speed and acuity; time taken to track from one column of print to the next; follow a route map, and locate a specific feature; and identification of specific information from a medicine label. RESULTS: Mouse EVES with HMD viewing caused lower reading speeds than stand EVES with monitor viewing (F = 38.7, P < .001). Reading with the optical magnifier was slower than with the mouse or stand EVES with monitor viewing at smaller print sizes (P < .05). The column location task was faster with the optical magnifier than with any of the EVES (F = 10.3, P < .001). The map tracking and medicine label identification task was slower with the mouse EVES with HMD viewing than with the other magnifiers (P < .01). Previous EVES experience had no effect on task performance (P > .05), but subjects with previous optical magnifier experience were significantly slower at performing the medicine label identification task with all of the EVES (P < .05). CONCLUSIONS: Although EVES provide objective benefits to the visually impaired in reading speed and acuity, together with some specific near tasks, some can be performed just as fast using optical magnification. © 2003 by Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to explore the relationship between electroencephalographic (EEG) activity in the gamma frequency range and conscious awareness of a visual stimulus. EEG was recorded from subjects while they were shown backward-masked words only some of which they were able to discriminate correctly. The results showed that activity in the gamma frequency range increase with reported awareness of a word independently of whether it was correctly discriminated or not. It is concluded that gamma power is associated with awareness-dependent visual processing but not with processing that occurs in the absence of awareness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are around 285 million visually impaired people worldwide, and around 370,000 people are registered as blind or partially sighted in the UK. Ongoing advances in information technology (IT) are increasing the scope for IT-based mobile assistive technologies to facilitate the independence, safety, and improved quality of life of the visually impaired. Research is being directed at making mobile phones and other handheld devices accessible via our haptic (touch) and audio sensory channels. We review research and innovation within the field of mobile assistive technology for the visually impaired and, in so doing, highlight the need for successful collaboration between clinical expertise, computer science, and domain users to realize fully the potential benefits of such technologies. We initially reflect on research that has been conducted to make mobile phones more accessible to people with vision loss. We then discuss innovative assistive applications designed for the visually impaired that are either delivered via mainstream devices and can be used while in motion (e.g., mobile phones) or are embedded within an environment that may be in motion (e.g., public transport) or within which the user may be in motion (e.g., smart homes). © 2013 Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel computing systems are increasingly being composed of large numbers of heterogeneous components, each with potentially different goals or local perspectives, and connected in networks which change over time. Management of such systems quickly becomes infeasible for humans. As such, future computing systems should be able to achieve advanced levels of autonomous behaviour. In this context, the system's ability to be self-aware and be able to self-express becomes important. This paper surveys definitions and current understanding of self-awareness and self-expression in biology and cognitive science. Subsequently, previous efforts to apply these concepts to computing systems are described. This has enabled the development of novel working definitions for self-awareness and self-expression within the context of computing systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines the contribution of early phonological processing (PP) and language skills on later phonological awareness (PA) and morphological awareness (MA), as well as the links among PA, MA, and reading. Children 4-6 years of age with poor PP at the start of school showed weaker PA and MA 3 years later (age 7-9), regardless of their language skills. PA and phonological and morphological strategies predict reading accuracy, whereas MA predicts reading comprehension. Our findings suggest that children with poor early PP are more at risk of developing deficits in MA and PA than children with poor language. They also suggest that there is a direct link between PA and reading accuracy and between MA and reading comprehension that cannot be accounted for by strategy use at the word level.