950 resultados para Hardy Operators
Resumo:
Dissertação de mestrado integrado em Engenharia e Gestão Industrial
Resumo:
Dissertação de mestrado em Engenharia Industrial
Resumo:
COST Action TU1406 aims to address the European economic and societal needs by standardizing the condition assessment and maintenance level of roadway bridges. Currently, bridge quality control plans vary from country to country and, in some cases, within the same country. This therefore urges the establishment of a European guideline to surpass the lack of a standard methodology to assess bridge condition and to define quality control plans for roadway bridges. Such a guideline will comprise specific recommendations for assessing performance indicators as well as for the definition of performance goals, bringing together different stakeholders (e.g. universities, institutes, operators, consultants and owners) from various scientific disciplines (e.g. on-site testing, visual inspection, structural engineering, sustainability, etc.) in order to establish a common transnational language. COST Action TU1406 Workshops aim to facilitate the exchange of ideas and experiences between active researchers and practitioners as well as to stimulate discussions on new and emerging issues in line with the conference topics. This first Workshop essentially focuses on WG1 issues, namely, intends to address performance indicators, how these are assessed (e.g. visual inspection, nondestructive tests and monitoring systems), with what frequency and what values are generally obtained. The main outcomes, given in this eBook, were really important, not only for WG1 developments, but also for all the other WGs and for the Action itself.
Resumo:
Dissertação de mestrado em Engenharia Mecânica
Resumo:
Dissertação de mestrado em Engenharia Industrial
Resumo:
Dissertação de mestrado em Crime, Diferença e Desigualdade
Resumo:
Relatório de estágio de mestrado em Ensino de Informática
Resumo:
Dissertação de Mestrado em Comunicação Social – variante da comunicação estratégica
Resumo:
FUNDAMENTO: A maioria dos trabalhos tem descrito preditores de recorrência de fibrilação atrial após ablação por cateter, com tempos de seguimento relativamente curtos. OBJETIVO: Avaliar retrospectivamente, em longo prazo, os preditores de recorrência de fibrilação atrial paroxística (FA) em pacientes submetidos ao isolamento das veias pulmonares, após um único procedimento. MÉTODOS: Foram estudados 139 pacientes (102 homens com idade média de 55 ± 12 anos) submetidos à ablação por radiofreqüência, por meio das técnicas ostial ou extra-ostial de abordagem do átrio esquerdo, associadas ou não à ablação do istmo cavo-tricuspídeo (ICT). Variáveis pré, intra e pós-ablação foram avaliadas por análise uni e multivariada, para determinar os preditores de recorrência da FA após um procedimento. RESULTADOS: Após um seguimento de 33 ± 12 meses, observou-se que maior tempo de história de FA, uso de mais antiarrítmicos e recorrência de FA num período de sessenta dias pós-procedimento aumentaram o risco de recorrência de FA em longo prazo. Por sua vez, a associação de flutter atrial e a ablação concomitante do ICT reduziram o risco de recorrência. CONCLUSÃO: Variáveis clínicas como tempo de história de FA e maior quantidade de antiarrítmicos já utilizadas influenciam os resultados da ablação por cateter. Em pacientes com flutter atrial associado, a realização concomitante de linha de bloqueio no ICT reduziu significativamente a recorrência de fibrilação atrial em longo prazo.
Resumo:
FUNDAMENTO: A ocorrência de fibrilação atrial (FA) após a ablação com sucesso do flutter atrial istmo cavo-tricuspídeo (FLA-ICT) dependente consiste em um evento de importância clínica. Os fatores preditores dessa ocorrência ainda são controversos. OBJETIVO: Determinar a incidência de FA e os fatores preditores para a sua ocorrência nos pacientes submetidos a ablação do flutter atrial istmo cavo-tricuspídeo (FLA-ICT) dependente. MÉTODOS: Cinquenta e dois pacientes portadores de FLA-ICT foram submetidos à ablação no período de janeiro de 2003 a março de 2004, no InCor do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. RESULTADOS: Durante o seguimento médio de 26,2 (± 9,2) meses, 16 (30,8%) pacientes apresentaram FA. A análise univariada revelou duas variáveis clínicas como preditoras de ocorrência de FA após a ablação do FLA-ICT maior ou igual a três anos (RR: 3,00; P = 0,020). Na análise multivariada, esses fatores foram variáveis independentes associadas à ocorrência de FA após ablação do FLA-ICT. CONCLUSÃO: A FA é frequentemente observada durante o seguimento dos pacientes após ablação de FLA-ICT dependente. O FLA-ICT persistente e a história de arritmia maior que três anos são fatores preditores para a ocorrência de FA durante o seguimento clínico.
Resumo:
Due to the global crisis o f climate change many countries throughout the world are installing the renewable energy o f wind power into their electricity system. Wind energy causes complications when it is being integrated into the electricity system due its intermittent nature. Additionally winds intennittency can result in penalties being enforced due to the deregulation in the electricity market. Wind power forecasting can play a pivotal role to ease the integration o f wind energy. Wind power forecasts at 24 and 48 hours ahead of time are deemed the most crucial for determining an appropriate balance on the power system. In the electricity market wind power forecasts can also assist market participants in terms o f applying a suitable bidding strategy, unit commitment or have an impact on the value o f the spot price. For these reasons this study investigates the importance o f wind power forecasts for such players as the Transmission System Operators (TSOs) and Independent Power Producers (IPPs). Investigation in this study is also conducted into the impacts that wind power forecasts can have on the electricity market in relation to bidding strategies, spot price and unit commitment by examining various case studies. The results o f these case studies portray a clear and insightful indication o f the significance o f availing from the information available from wind power forecasts. The accuracy o f a particular wind power forecast is also explored. Data from a wind power forecast is examined in the circumstances o f both 24 and 48 hour forecasts. The accuracy o f the wind power forecasts are displayed through a variety o f statistical approaches. The results o f the investigation can assist market participants taking part in the electricity pool and also provides a platform that can be applied to any forecast when attempting to define its accuracy. This study contributes significantly to the knowledge in the area o f wind power forecasts by explaining the importance o f wind power forecasting within the energy sector. It innovativeness and uniqueness lies in determining the accuracy o f a particular wind power forecast that was previously unknown.
The appraisal of anaerobic digestion in Ireland to develop improved designs and operational practice
Resumo:
Mesophilic Anaerobic Digestion treating sewage sludge was investigated at five full-scale sewage treatment plants in Ireland. The anaerobic digestion plants are compared and evaluated in terms of design, equipment, operation, monitoring and management. All digesters are cylindrical, gas mixed and heated Continuously Stirred Tank Reactors (CSTR), varying in size from 130m3 to 800m3. Heat exchanger systems heat all digesters. Three plants reported difficulties with the heating systems ranging from blockages to insufficient insulation and design. Exchangers were modified and replaced within one year of operation at two plants. All but one plant had Combined Heat and Power (CHP) systems installed. Parameter monitoring is a problem at all plants mainly due to a lack of staff and knowledge. The plant operators consider pH and temperature the most important parameters to be measured in terms of successful monitoring of an anaerobic digester. The short time taken and the ease at which pH and temperature can be measured may favour these parameters. Three laboratory scale pilot anaerobic digesters were operated using a variety of feeds over at 144-day period. Two of the pilots were unmixed and the third was mechanically mixed. As expected the unmixed reactors removed more COD by retention of solids in the digesters but also produced greater quantities of biogas than the mixed digester, especially when low solids feed such as whey was used. The mixed digester broke down more solids due to the superior contact between the substrate and the biomass. All three reactors showed good performance results for whey and sewage solids. Scum formation occurred giving operational problems for mixed and unmixed reactors when cattle slurry was used as the main feed source. The pilot test was also used to investigate which parameters were the best indicators of process instability. These trials clearly indicated that total Volatile Fatty Acid (VFA) concentrations was the best parameter to show signs of early process imbalance, while methane composition in the biogas was good to indicate possible nutrient deficiencies in the feed and oxygen shocks. pH was found to be a good process parameter only if the wastewater being treated produced low bicarbonate alkalinities during treatment.
Resumo:
FUNDAMENTO: O polimorfismo AGT*M235T tem sido associado a elevados níveis séricos de angiotensinogênio (AGT), hipertensão arterial sistêmica e disfunção cardíaca (DC). OBJETIVO: Testar a hipótese de haver associação entre polimorfismo AGT*M235T e o risco de desenvolver disfunção cardíaca (insuficiência cardíaca ou disfunção sistólica ventricular esquerda assintomática) pós-síndrome coronariana aguda (SCA), durante o período de internação hospitalar. MÉTODOS: Foram estudados 363 pacientes (idade média 62 ± 12 anos), sendo 233 (64%) homens e 130 (36%) mulheres, todos da mesma coorte, internados por SCA. Compararam-se dados clínicos e genéticos dos 117 (32,2%) que evoluíram com disfunção cardíaca (grupo caso) com os dos 246 (67,8%), que não desenvolveram tal condição (grupo controle). O polimorfismo AGT*M235T foi determinado por análise de sequenciamento e estava em equilíbrio de Hardy-Weinberg. RESULTADOS: Houve diferença significativa na distribuição dos genótipos nas mulheres, com predomínio do genótipo *235MM no grupo controle (p = 0,001) e do alelo *235T no grupo caso. Em ambos os sexos, nos modelos de regressão logística, o diagnóstico de infarto de parede anterior na admissão foi fator de incremento no risco de DC, enquanto angina instável na admissão, ausência do alelo *235T, glicemia < 100 mg/dl, uso de betabloqueador, creatinina sérica < 1,5 mg/dl, faixa de frequência cardíaca > 60 e < 90 bpm e tabagismo atual foram fatores de redução do risco de DC. CONCLUSÃO: Este estudo sugere que a ausência do alelo *235T do AGT contribui para a redução do risco de disfunção cardíaca pós-síndrome coronariana aguda.
Polimorfismos beta1-adrenérgico associados com Fibrilação Atrial na Insuficiência Cardíaca Sistólica
Resumo:
FUNDAMENTO: O sistema nervoso simpático apresenta grande importância na patogênese da fibrilação atrial na insuficiência cardíaca sistólica. A identificação de polimorfismos no gene ADBR1 do receptor beta1-adrenérgico representa um importante passo no conhecimento dessa patogênese. OBJETIVO: Este estudo analisou a associação entre os dois polimorfismos funcionais do gene ADBR1 do receptor beta1-adrenérgico, Ser49Gly e Arg389Gly, e a presença da fibrilação atrial em pacientes com insuficiência cardíaca sistólica. MÉTODOS: Estudo caso-controle com 144 pacientes portadores de insuficiência cardíaca sistólica, dos quais 24 com fibrilação atrial (casos) e 120 sem fibrilação atrial (controles). O DNA genômico foi extraído de leucócitos do sangue periférico e os genótipos dos polimorfismos Ser49Gly e Arg389Gly foram identificados em todos os indivíduos por PCR/RFLP (polymerase chain reaction / restriction fragment length polymorphism). RESULTADOS: A média etária foi 59 ± 13 anos, 70% dos pacientes eram do sexo masculino, 42% apresentavam causa isquêmica e 74% apresentavam hipertensão arterial sistêmica. Os genótipos Ser49Ser e Arg389Arg apresentaram associação significativa com fibrilação atrial (p = 0,005 e p = 0,01; respectivamente). Por meio de regressão logística, ambos ajustados para o tamanho do átrio esquerdo e idade, mantiveram associação significativa (Arg389Arg - odds ratios: 2,78; intervalo de confiança de 95% = 1,02 - 7,56 e Ser49Ser - odds ratios: 8,02; intervalo de confiança de 95% = 1,02 - 63,82). CONCLUSÃO: Ambos os genótipos associaram-se com fibrilação atrial nos pacientes estudados, porém apenas o polimorfismo Ser49Gly apresentava-se em equilíbrio de Hardy-Weinberg.
Resumo:
FUNDAMENTO: Ablação por radiofrequência (ARF) em crianças consiste em uma prática cada vez mais frequente. OBJETIVO: Avaliar, em nossa instituição, os resultados da ARF em crianças com idade abaixo de 15 anos. MÉTODOS: Foram analisadas 125 crianças submetidas à ARF entre maio de 1991 a maio de 2010. RESULTADOS: Sessenta e sete (53,6%) crianças eram do sexo masculino, com idade entre 44 dias e 15 anos (média de 8,6 ± 3,3 anos) e peso mediano de 31 kg. Cardiopatia esteve presente em 21 (16,8%) pacientes. A ARF de vias acessórias (VA) foi o procedimento mais comum (62 crianças - 49,6%). A ARF de taquicardias por reentrada nodal (TRN) foi a segunda arritmia mais frequente, em 27 (21,6%), seguida de taquicardias atriais (TA), em 16 (12,8%) e de taquicardias ventriculares (TV) em 8 (6,4%) crianças. Os critérios de sucesso foram alcançados em 86,9%, 96,1%, 80% e 62,5% dos pacientes submetidos à ARF de VA, TRN, TA e TV, respectivamente. Os bloqueios atrioventriculares transitórios (BAVT) ocorreram durante a ARF em 4 (3,2%) e BRD em 7 (5,6%) crianças. Vinte e cinco crianças foram submetidos à nova ARF por insucesso inicial ou recorrência. Durante o seguimento médio de 5,5 ± 3,4 anos, 107 (88,4%) persistiram sem recorrência. Não houve diferença estatística em relação aos resultados e à idade em que o paciente se submeteu ao procedimento. Nenhuma criança apresentou BAVT persistente ou necessitou de marca-passo definitivo. CONCLUSÃO: A ablação por cateter é uma alternativa terapêutica segura e eficiente em crianças com taquicardias recorrentes refratárias ao tratamento clínico.