858 resultados para Green chromatography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of modular home made capillary electrophoresis equipment with spectrophotometric detection, at a visible region by means of a miniaturized linear charge coupled device, was evaluated for the determination of four food dyes. This system presents a simple but efficient home made cell detection scheme. A computer program that converts the spectral data after each run into the electropherograms was developed to evaluate the analytical parameters. The dyes selected for analytical evaluation of the system were Brilliant Blue FCF, Fast Green FCF, Sunset Yellow FCF, and Amaranth. Separation was carried out in a 29cm length and 75 mu m I.D fused silica capillary, using 10mmolL-1 borate buffer at pH 9, with separation voltage of 7.5kV. The detection limits for the dyes were between 0.3 and 1.5mgL-1 and the method presented adequate linearity over the ranges studied, with correlation coefficients greater than 0.99. The method was applied for determination and quantification of these dyes in fruit juices and candies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for the determination of pesticide residues in water and sediment was developed using the QuEChERS method followed by gas chromatography - mass spectrometry. The method was validated in terms of accuracy, specificity, linearity, detection and quantification limits. The recovery percentages obtained for the pesticides in water at different concentrations ranged from 63 to 116%, with relative standard deviations below 12%. The corresponding results from the sediment ranged from 48 to 115% with relative standard deviations below 16%. The limits of detection for the pesticides in water and sediment were below 0.003 mg L(-1) and 0.02 mg kg(-1), respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Colby Green is a campus expansion project which began in October of 2003. The construction would result in three new buildings, additional parking, and an elliptical 75,000-squarefoot green southeast of Mayflower Hill Drive. There were also plans for the construction of three run-off management and sediment ponds below the green, to manage flooding of the green. Three drains in the green transport water to the three retaining ponds which slowly disperse water into the surrounding environment. The ponds were created by constructing earthen dams around the drain outlets. The dams are composed of soil, cobbles, and boulders procured from the surrounding excavation site. Unfortunately, earthen dams are susceptible to many types of erosion which result in their failure. In this case the potential for clay and silt from the underlying Presumpscot Formation to mix with the soil in the earthen dams raised concerns with regards to frost action. In order to monitor the surface displacement of the dams I drove 92 poles into the ground in 8 straight lines across the faces of the dams in the fall of 2005. I returned to the sites during and after the spring thaw of 2006, to check for any signs of movement resulting from frost-heave, surface creep, or any other form of mass wasting. Fortunately, there was no recordable sign of movement in the stakes across any of the retaining ponds. The dams appear to be functioning as designed.