935 resultados para Fundição odontológica - Revestimento


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the treatment of extrusive luxation cases, it is important that the repositioning of extruded tooth in the socket is done as soon as possible. If this does not occur, periapical clot becomes organized and makes replantation difficult reposition. In this article the patient referred to the Clinics for dental trauma sustaining extrusive luxation of the maxillary right central incisor. The patient reported having suffered a bicycle accident 12 days before, which caused traumatic tooth injuries. The repositioning was attempted without success and an alternative form of treatment was necessary to solve the case. Intentional tooth replantation, which is the deliberate extraction of the tooth and its replantation, was indicated. This technique allows clot removal and correct repositioning of the extruded tooth. Care should be taken as endodontic treatment is required for the prevention of subsequent infection-related resorption. Intracanal dressing with calcium hydroxide was used for 30 days before final root filling. Splint, systemic antibiotics and avoidance of further damage to the root surface is also important. After 49 months, showed clinical and radiographic characteristics of normality and demonstrates the availability of this technique to adversity in trauma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to analyze the relationship between oral diseases and their impact on the daily performance of adult and elderly Brazilians, verify the association of oral diseases with socioeconomic and demographic features, and compare the standard estimate of need with the sociodental assessment of these same needs. The authors evaluated data from 17,398 Brazilians aged between 35-44 years and 65-74 years, taken from the cross-sectional Brazilian Oral Health Survey (Saúde Bucal Brasil - SBBrasil). Regression models were applied to assess associations among impacts on daily performance and income, schooling, gender, region, use of dental services, health perception and dental disease status. McNemar’s test was applied to compare standard versus impact-related estimates of need. The prevalence ratio of these impacts was associated with the sociodemographic versus health perceptions (p < 0.001) of adults and the elderly. Adults also had impacts associated with loss of periodontal attachment (p < 0.001). The prevalence of normative needs was 95.39% for adults and 99.76% for the elderly, whereas the impact-related estimate of need was 50.92% and 43.71%, respectively. The impacted-related approach had a statistically significant association with the normative estimate of need (p < 0.001). This study showed a relationship between oral impact on daily performance of adults and educational level. Sociodemographic features were also related to the impacts on both adults and the elderly, and to health perception. The impacts among the adults were related to the loss of periodontal attachment. In addition, the authors found a sizable difference between the standard versus the sociodental approach, in that the sociodental assessment needs were lower than the needs identified by the standard estimate of need.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the 12-month clinical performance of glass ionomer restorations in teeth with MIH. First permanent molars affected by MIH (48) were restored with glass ionomer cement (GIC) and evaluated at baseline, at 6 and at 12 months, by assessing tooth enamel breakdown, GIC breakdown and caries lesion associations. The data were analyzed using the chi-square test and actuarial survival analysis. The likelihood of a restored tooth remaining unchanged at the end of 12 months was 78%. No statistically significant difference was observed in the association between increased MIH severity and caries at baseline (p > 0.05) for a 6-month period, or between increased MIH severity and previous unsatisfactory treatment at baseline (p > 0.05) for both a 6- and 12-month period. A statistically significant difference was observed in the association between increased MIH severity and extension of the restoration, involving 2 or more surfaces (p < 0.05) at both periods, and between increased MIH severity and caries at baseline (p < 0.05) at a 12-month period. Because the likelihood of maintaining the tooth structures with GIC restorations is high, invasive treatment should be postponed until the child is sufficiently mature to cooperate with the treatment, mainly of teeth affected on just one face.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the fracture resistance of simulated immature teeth after different intra-radicular treatments. Crowns and roots of bovine incisors were cut transversally and removed to simulate immature teeth. Root canal preparation and flaring were performed using a bur in crown-apex and apex-crown direction. The samples were distributed into 5 groups (n=10): Positive control (PoC) - no root canal flaring or filling; Negative control (NeC) - teeth were sectioned and their root canals were flared; Direct anatomical glass fiber post (RaP) - #2 Reforpost main glass fiber post relined with composite resin; Double tapered conical glass fiber posts (ExP) - #3 Exacto glass fiber post; and #2 Reforpost main glass fiber + Reforpin accessory glass fiber posts (RrP). In RaP, ExP and RrP, 4.0-mm apical plugs were done with MTA Angelus. The specimens were embedded in polystyrene resin inside cylinders and the periodontal ligament was simulated with a polyether-based impression material. The specimens were submitted to compressive fracture strength test (0.5 mm/min at 135° relative to the long axis of the tooth) in a servo-hydraulic mechanical testing machine MTS 810. Data were subjected to one-way ANOVA and Dunnett's C or Tukey's tests (α=0.05). The control groups (PoC and NeC) showed lower fracture strength than the experimental groups. NeC presented the lowest resistance and ExP presented the highest resistance among the experimental groups. The flaring procedures produced a detrimental effect on the fracture resistance of the bovine teeth. Glass fiber intra-radicular posts increased significantly the fracture resistance of simulated immature teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study aimed to assess the influence of curing distance on the loss of irradiance and power density of four curing light devices. The behavior in terms of power density of four different dental curing devices was analyzed (Valo, Elipar 2, Radii-Cal, and Optilux-401) using three different distances of photopolymerization (0 mm, 4 mm, and 8 mm). All devices had their power density measured using a MARC simulator. Ten measurements were made per device at each distance. The total amount of energy delivered and the required curing time to achieve 16 J/cm2 of energy was also calculated. Data were statistically analyzed with one-way analysis of variance and Tukey’s tests (p < 0.05). The curing distance significantly interfered with the loss of power density for all curing light devices, with the farthest distance generating the lowest power density and consequently the longer time to achieve an energy density of 16 J/cm2 (p < 0.01). Comparison of devices showed that Valo, in extra power mode, showed the best results at all distances, followed by Valo in high power mode, Valo in standard mode, Elipar 2, Radii-Cal, and Optilux-401 halogen lamp (p < 0.01). These findings indicate that all curing lights induced a significant loss of irradiance and total energy when the light was emitted farther from the probe. The Valo device in extra power mode showed the highest power density and the shortest time to achieve an energy density of 16 J/cm2 at all curing distances.