994 resultados para Flatness deviation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The efficiency of XAD®-2 resin in sampling the pesticides α and β-endosulfan from air contaminated in the laboratory was evaluated. Sampling efficiency ranged from 87 to 108% for α-endosulfan and from 71 to 84% for β-endosulfan with relative standard deviation lower than 19%. The pesticides were not detected in the second section of the cartridge showing the good retention capacity of XAD®-2 for these analytes. Method quantification limits were 0.32 and 0.34 µg m-3 for α and β-endosulfan, respectively. These results suggest that the proposed method may be useful for evaluating occupational exposure to these compounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We developed a simple, rapid, and solventless method for analyzing trihalomethanes in beer samples using headspace solid-phase microextraction. The effects of varying experimental parameters, such as extraction temperature and time, addition of sodium chloride, and agitation speed, on extraction yield were studied using a univariate experimental design. Limits of detection between 0.22 and 0.46 µg L- 1 and wide linear ranges were achieved for trihalomethanes. We measured the trihalomethane recoveries and precision (as the standard deviation of repeat measurements) and demonstrated the applicability of the proposed method by analyzing 32 beer samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and fast approach for solid phase extraction is herein described, and used to determine trace amounts of Pb2+ and Cu2+ metal ions. The solid phase support is sodium dodecyl sulfate (SDS)-coated γ-alumina modified with bis(2-hydroxy acetophenone)-1,6-hexanediimine (BHAH) ligand. The adsorbed ions were stripped from the solid phase by 6 mL of 4 M nitric acid as eluent. The eluting solution was analyzed by flame atomic absorption spectrometry (FAAS). The sorption recovery of metal ions was investigated with regard to the effects of pH, amount of ligand, γ-alumina and surfactant and the amount and type of eluent. Complexation of BHAH with Pb2+ or Cu2+ ions was examined via spectrophotometry using the HypSpec program. The detection limit for Cu2+ was 7.9 µg L-1 with a relative standard deviation of 1.67%, while that for Pb2+ was 6.4 µg L-1 with a relative standard deviation of 1.64%. A preconcentration factor of 100 was achieved for these ions. The method was successfully applied to determine analyte concentrations in samples of liver, parsley, cabbage, and water.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Simple and sensitive procedures for the extraction/preconcentration of molybdenum based on vortex-assisted solidified floating organic drop microextraction (VA-SFODME) and cloud point combined with flame absorption atomic spectrometry (FAAS) and discrete nebulization were developed. The influence of the discrete nebulization on the sensitivity of the molybdenum preconcentration processes was studied. An injection volume of 200 µL resulted in a lower relative standard deviation with both preconcentration procedures. Enrichment factors of 31 and 67 and limits of detection of 25 and 5 µg L-1 were obtained for cloud point and VA-SFODME, respectively. The developed procedures were applied to the determination of Mo in mineral water and multivitamin samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Capsaicinoids (CAPS) are substances responsible for pungency in Capsicum. It is important to quantify these types of compounds owing to their broad application in food, pharmaceuticals, cosmetics and chemical weapons. In this work, we developed an indirect spectrophotometric method based on the colorimetric reaction between CAPS, Co(II) 3.10×10-5 mol L-1 and 4-(2-pyridylazo) resorcinol (PAR) 6.23×10-5 and, in cachaça:water 92:8v/v solutions, for quantification of total CAPS in Capsicum peppers. The product of the reaction is CoPAR2CAPS2 and its absorption in aquo-ethanolic solution at 510 nm is proportional to the total CAPS concentration from 0.60 to 17.94 mg L-1. The values of limit of detection and limit of quantification were 0.0004 and 0.001 mg of CAPS/g of pepper, respectively, with 4% relative standard deviation. The developed method yielded similar results to those obtained from high performance liquid chromatography, with 95% of confidence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dispersive liquid-liquid microextraction procedure coupled to spectrophotometry is described for the determination of the trace levels of Sudan Blue II. Analytical parameters, such as pH, volume of extraction solvent (carbon tetrachloride), volume of dispersant (ethanol), volume of sample, and extraction time, were optimized. Matrix effects were also investigated. Preconcentration factor was found to be 200. Detection limit and relative standard deviation (RSD) were 0.55 µg L-1 and 3.9%, respectively. The procedure was successfully used for the determination of trace levels of Sudan Blue II in food, ink, antifreeze, and industrial waste-water samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An improved method based on reverse flow injection is proposed for determining sulfate concentration in the wet-process of phosphoric acid (WPA). The effect of reagent composition, flow rate, temperature, acid concentration, length of the reaction coil, and linear response range on the flow system is discussed in detail. Optimal conditions are established for determining sulfate in the WPA samples. Baseline drift is avoided by a periodic washing step with EDTA in an alkaline medium. A linear response is observed within a range of 20 - 360 mg L-1, given by the equation A = 0.0020C (mg L-1) + 0.0300, R² = 0.9991. The detection limit of the proposed method for sulfate analysis is 3 mg L-1, and the relative standard deviation (n = 12) of sulfate absorbance peak is less than 1.60%. This method has a rate of up to 29 samples per hour, and the results compare well with those obtained with gravimetric method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this research, scanometry was used as a new, simple, fast and inexpensive method for a colorimetric determination of Mn2+ ion in water samples and thermocouple wire through the use of periodate reagent in an acidic medium. The results showed the oxidization of colorless Mn2+ ion by periodate and the formation of a purplish MnO4- ion. The system had a linear range of 1.0 to 70.0 µg mL-1 Mn2+ ion with a detection limit of 0.314 µg mL-1 and a relative standard deviation of 2.77% for G color value. This method has the capability to determine low levels of Mn2+ ion in thermocouple wire and water samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple preconcentration method of silicon based on coprecipitation with aluminum hydroxide prior to its flame atomic absorption (FAAS) determination was established. The recovery values of analyte ion was higher than 95%. The parameters including types of hydroxide ion source for precipitation, acid type for dissolution step, amount of aluminum ion as collector, pH, temperature, standing and centrifuge time, and sample volume were optimized for the quantitative recovery of the analyte. The influences of matrix ions were also examined. The relative standard deviation was found to be 3.2%. The limit of detection was calculated as (0.1 mg L-1). The preconcentration factor is 100 for (200 mL) solution. The proposed method was successfully applied for the determination of silicon in some water and alloy samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the evaluation of simple and fast solubilization methods for the determination of Ca, Mg, and K in glycerin samples from biodiesel production by atomic spectrometry. The solubilization in water was compared with two other methods: solubilization in formic acid and solubilization in ethanol. Using solubilization in water, determination of the three analytes was possible; the values of limits of detection for Ca, K, Mg were 0.31, 0.06, and 0.16 mg kg−1, respectively. Because no adequate reference material was available, the accuracy was evaluated by assessing the recoveries tests with both solubilization methods; the evaluation ranged from 90% to 115%, with values of relative standard deviation >8%, indicating good accuracy of the measure. Four crude glycerin samples obtained from biodiesel plants of Rio Grande do Sul were analyzed after treatment with the different methods of solubilization, and the obtained results of Ca, Mg, and K concentration were in agreement with the values obtained from both solubilization methods. Therefore, solubilization in water is concluded to be a simpler, faster, and viable method for sample preparation of glycerin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to monitor 11 organophosphorus pesticides in samples of papaya, bell pepper, and banana, commercialized in the metropolitan area of Vitória (ES, Brazil). The pesticides were determined by an optimized and validated method using high performance liquid chromatography with tandem mass spectrometry (HPLC-MS/MS). All three samples exhibited a matrix effect for most of the pesticides, mainly with signal suppression, and therefore the calibration curves were produced in matrices. Linearity revealed coefficients of determination (r2) greater than 0.9895 for all pesticides and recovery results ranged from between 76% and 118% with standard deviation no greater than 16%. Precision showed relative standard deviation values lower than 19% and HorRat values lower than 0.7, considering all pesticides. Limits of quantification were less than 0.01 mg/kg for all pesticides. Regarding analysis of the samples (50 of each), none of the pesticides exceeded the maximum residue limit determined by Brazilian legislation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An evaluation of the pesticides extracted from the soil matrix was conducted using a citrate-buffered solid phase dispersion sample preparation method (QuEChERS). The identification and quantitation of pesticide compounds was performed using gas chromatography-mass spectrometry. Because of the occurrence of the matrix effect in 87% of the analyzed pesticides, the quantification was performed using matrix-matched calibration. The method's quantification limits were between 0.01 and 0.5 mg kg-1. Repeatability and intermediate precision, expressed as a relative standard deviation percentage, were less than 20%. The recoveries in general ranged between 62% and 99%, with a relative standard deviation < 20%. All the responses were linear, with a correlation coefficient (r) ≥0.99.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractThis work describes the development of a biosensor based on the tyrosinase enzyme (Tyr) for the determination of phenol (PHEN) in laboratory effluent samples derived from ammoniacal nitrogen analysis of the water samples from the Muquém dam in the city of Cariús, CE, using square-wave voltammetry (SWV). The electrode modification consisted of the immobilization of gold nanoparticles, multi-walled carbon nanotubes, cobalt phthalocyanine, and Tyr on a glassy carbon electrode. The electrolyte, pH, enzyme quantity, and voltammetric parameters were optimized to detect PHEN. The analytical curves presented a linear range from 4.97 × 10-6 mol L-1 to 6.10 × 10-5 mol L-1, and the detection limit (DL) and quantitation limit (QL) values were 4.81 × 10-6 mol L-1 and 4.97 × 10-6mol L-1, respectively. The repetition of measurements with the same biosensor and repetition for three other prepared biosensors exhibited a relative standard deviation (RSD) of 5.50 and 1.75%, respectively. The percentage recovery of PHEN in effluent samples varied from 86.40 to 105.04%. The stability of the biosensor was evaluated (at 21 days) with satisfactory results, showing 97.86% of the initial response. Moreover, the DL and recovery percentages agreed with the established values from CONAMA and ABNT, respectively. Thus, the electrode configuration developed seems a promising tool in the detection and quantification of PHEN in complex samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Having inventory to cover from all possible problems would increase the inventory level indefinitely in accordance with the standard deviation. If the materials in stock are not used, but kept just to be on the safe side, they are waste. The main objective of this study was to find out, how much inventory is required to cover the requirements, without causing delivery problems towards the end-customers, and how the inventory could be controlled efficiently. Several improvements were made in the controlling principles, and the inventory level was quickly decreased by more than 30 %, and kept on the reached level. The suitability of kanban control was investigated, and it was eventually taken into some use. A great advantage was found in the new procedures in securing the supply. The requests for quotations were diversified, and the faulty basis was corrected. Thus, the inventory surplus would later be avoided, and at the same time, a lot of valuable time was saved from daily routines to further improvement projects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this paper was to evaluate the potential of neural networks (NN) as an alternative method to the basic epidemiological approach to describe epidemics of coffee rust. The NN was developed from the intensities of coffee (Coffea arabica) rust along with the climatic variables collected in Lavras-MG between 13 February 1998 and 20 April 2001. The NN was built with climatic variables that were either selected in a stepwise regression analysis or by the Braincel® system, software for NN building. Fifty-nine networks and 26 regression models were tested. The best models were selected based on small values of the mean square deviation (MSD) and of the mean prediction error (MPE). For the regression models, the highest coefficients of determination (R²) were used. The best model developed with neural networks had an MSD of 4.36 and an MPE of 2.43%. This model used the variables of minimum temperature, production, relative humidity of the air, and irradiance 30 days before the evaluation of disease. The best regression model was developed from 29 selected climatic variables in the network. The summary statistics for this model were: MPE=6.58%, MSE=4.36, and R²=0.80. The elaborated neural networks from a time series also were evaluated to describe the epidemic. The incidence of coffee rust at four previous fortnights resulted in a model with MPE=4.72% and an MSD=3.95.