932 resultados para Fallopian Tubes
Resumo:
The aim of this study was to evaluate the rat subcutaneous tissue reaction to calcium hydroxide-based intracanal medicaments, UltraCal XS (calcium hydroxide, barium sulphate, aqueous matrix), Hydropast (calcium hydroxide, barium sulphate, and propyleneglycol), and Calen (Calcium hydroxide, zinc oxide, colophony, and polyethyleneglycol), used as a control. Methods. Forty-eight rats (Rattus Norvegicus Holtzman) were distributed in three groups: Calen, UltraCal XS, and Hydropast. Polyethylene tubes filled with one of the medicaments were implanted in the dorsal subcutaneous. After 7 and 30 days, the implants were removed and the specimens were fixed and embedded in paraffin. Morphological and quantitative analyses were carried out in the HE-stained sections. The numerical density of inflammatory cells in the capsule was evaluated and statistical analyses were performed (P>/0.05). Results. At 7 days, all materials induced an inflammatory reaction in the subcutaneous tissue adjacent to the implants. In all groups, a significant reduction in the number of inflammatory cells and giant cells was verified in the period of 30 days. Conclusion. These results indicate that the calcium hydroxide-based medicaments evaluated present biocompatibility similar to Calen.
Resumo:
The aim of this study was to evaluate the antimicrobial activity and pH changes induced by Portland cement (PC) alone and in association with radiopacifiers. Methods. The materials tested were pure PC, PC + bismuth oxide, PC + zirconium oxide, PC + calcium tungstate, and zinc oxide and eugenol cement (ZOE). Antimicrobial activity was evaluated by agar diffusion test using the following strains: Micrococcus luteus, Streptococcus mutans, Enterococcus faecalis, Pseudomonas aeruginosa, and Candida albicans. After 24 hours of incubation at 37°C, inhibition of bacterial growth was observed and measured. For pH analysis, material samples (n=10) were placed in polyethylene tubes and immersed in 10 mL of distilled water. After 12, 24, 48, and 72 hours, the pH of the solutions was determined using a pH meter. Results. All microbial species were inhibited by the cements evaluated. All materials composed of PC with radiopacifying agents promoted pH increase similar to pure Portland cement. ZOE had the lowest pH values throughout all experimental periods. Conclusions. All Portland cement-based materials with the addition of different radiopacifiers (bismuth oxide, calcium tungstate, and zirconium oxide) presented antimicrobial activity and pH similar to pure Portland cement.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Aperfeiçoamento em equipamento para digestão de amostras por via úmida. É descrito um aperfeiçoamento em equipamento para digestão de amostras por via úmida que emprega tubos de digestão (20) fechados não encapsulados e aquecimento condutivo que possibilita a rápida decomposição de amostras botânicas, alimentícias, clínicas, ambientais e similares, promovendo um gradiente de temperatura em direção à parte superior do tubo de digestão, permitindo que a temperatura da fase gasosa seja inferior à da fase líquida, de forma que as digestões são realizadas à pressão pouco elevada e, consequentemente, os tubos de digestão utilizados podem ter paredes menos espessas, permitindo o rápido aquecimento e resfriamento das amostras, bem como baixo custo de operação e manutenção, simplicidade, alta frequência analítica,; redução do consumo de reagentes e diminuição da geração de resíduos, dito equipamento provido de um gabinete (10) que evita a contaminação da atmosfera do laboratório por vapores ácidos e a perda dos componentes voláteis da amostra durante o aquecimento
Resumo:
The Cell-dyn 3500 is a multiparameter flow cytometer, which may analyze samples from several species performing several simultaneous analyses. It is able to perform white blood cells, red blood cells and platelet counts, besides differential leukocyte counts, packed cell volume and hemoglobin determination. Cell-Dyn 3500 performs total leukocyte count both optically and by impedance. The equipment may choose one or other method, based on the reliability of the results. Erythrocyte and platelet counts are determined by impedance. Leukocyte differentiation is based on an optical principle, using separation in multiangular polarized light. The objective of this study was to compare the results of complete blood count of Zebu Nellore heifers from Cell-dyn 3500, with those obtained from a semi-automated cell counter (Celm CC 510) and the manual technique. Blood samples were collected from the jugular vein in 5 mL EDTA vacuum tubes from 58 Nellore heifers, at 24 months of age. Samples were processed in parallel in the three different techniques. Results were analyzed using paired t test, Pearson's correlation and the Bland-Altmann method. There was a strong correlation for all parameters analyzed by Cell-Dyn 3500, manual method and semi-automated cell counter, except for basophils and monocytes counts. These results confirm that this analyzer is reliable for blood samples analysis of zebu cattle.
Resumo:
This study aimed to characterize and evaluate the performance of four models self-compensating drippers commonly used in drip irrigation systems in Brazil. To perform the study it was taking a sample of 25 emitters of each model. Evaluating their tubes (b) coefficient of manufacturing variation (c) wall thickness, (d) characteristic equation of the dripper, (e) internal diameter of the pipe, (f) spacing between emitters, (g) resistance water pressure at ambient temperature and to 40°C and (h) the tensile strength of the pipe with tension of 160 N and 180 N. The analysis showed variation coefficient of less than 0.045 for all manufacturing drippers (0.07 is maximum according to ABNT NBR ISO 9261). The exponents x of the equation pressure versus discharge ranged from 0.0082 to 0.0691 classifying them as self-compensating. From the results obtained it is clear that the tested products which are used in Brazil and used by irrigators had a satisfactory hydraulic performance in accordance with the standard.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
We collected 50 samples of curasow feces from the Scientific and Cultural Breeding Center in the city of Poços de Caldas. The samples were enriched in broth medium Tetrationato and Cystine-selenite and plated on Salmonella Shigella (SS), Mac Conkey (MC), endo-C (EC), Brilliant Green (VB) and Eosyn Methilen Blue EMB, remaining at 37 °C for 24h. Colonies suspected of Salmonella were inoculated in tubes containing Agar Triple Sugar Iron (TSI) and again incubated at 37 ºC for 24h. Tubes with characteristic growth were submitted to slide agglutination test with polyvalent somatic and flagellar serum. The medium SS, MC and VB were the most efficient for growing, and 36% of samples were positive for Salmonella spp. As birds are important reservoirs of Salmonella spp and it may represent a high risk to human health, there is a need to implement a cleaning routine in enclosures avoiding contamination between the enclosures and the consequent entrainment of these micro-organisms, by the keepers until their homes or other venues. The presence of Salmonella in breeding centers may be responsible for lower hatchability of eggs, undermining the purpose of the entity, which is to study and maintain the various birds species.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Ciência Odontólogica - FOA
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS