961 resultados para FREE-RANGING CATS
Resumo:
The Free Open Source Software (FOSS) seem far from the military field but in some cases, some technologies normally used for civilian purposes may have military applications. These products and technologies are called dual-use. Can we manage to combine FOSS and dual-use products? On one hand, we have to admit that this kind of association exists - dual-use software can be FOSS and many examples demonstrate this duality - but on the other hand, dual-use software available under free licenses lead us to ask many questions. For example, the dual-use export control laws aimed at stemming the proliferation of weapons of mass destruction. Dual-use export in United States (ITAR) and Europe (regulation 428/2009) implies as a consequence the prohibition or regulation of software exportation, involving the closing of source code. Therefore, the issues of exported softwares released under free licenses arises. If software are dual-use goods and serve for military purposes, they may represent a danger. By the rights granted to licenses to run, study, redistribute and distribute modified versions of the software, anyone can access the free dual-use software. So, the licenses themselves are not at the origin of the risk, it is actually linked to the facilitated access to source codes. Seen from this point of view, it goes against the dual-use regulation which allows states to control these technologies exportation. For this analysis, we will discuss about various legal questions and draft answers from either licenses or public policies in this respect.
Resumo:
Softcatalà is a non-profit associationcreated more than 10 years ago to fightthe marginalisation of the Catalan languagein information and communicationtechnologies. It has led the localisationof many applications and thecreation of a website which allows itsusers to translate texts between Spanishand Catalan using an external closed-sourcetranslation engine. Recently,the closed-source translation back-endhas been replaced by a free/open-sourcesolution completely managed by Softcatalà: the Apertium machine translationplatform and the ScaleMT web serviceframework. Thanks to the opennessof the new solution, it is possibleto take advantage of the huge amount ofusers of the Softcatalà translation serviceto improve it, using a series ofmethods presented in this paper. In addition,a study of the translations requestedby the users has been carriedout, and it shows that the translationback-end change has not affected theusage patterns.
Resumo:
Metallic foreign bodies are rarely found in the maxillary sinus, and usually they have a dental origin.Potential complications related to foreign bodies include recurrent sinusitis, rhinolith formation, cutaneous fistula,chemical poisoning, facial neuralgic pain and even malignancies.Two main surgical approaches are currently used for the removal of foreign bodies in the maxillary sinus: the bone flap and the endoscopic sinus techniques. We are reporting two unusual cases of large high-velocity foreign bodies removed by a modified maxillary lateral antrotomy,with free bone flap repositioning and fixation with a titanium miniplate.
Resumo:
rejection can lead to loss of function. Histological reading of endomyocardial biopsy remains the "gold standard" for guiding immunosuppression, despite its methodological limitations (sampling error and interobserver variability). The measurement of the T2 relaxation time has been suggested for detection of allograft rejection, on the pathophysiological basis that the T2 relaxation time prolongs with local edema resulting from acute allograft rejection. Using breath-held cardiac magnetic resonance T2 mapping at 1.5 T, Usman et al. (CircCardiovascImaging2012) detected moderate allograft rejection (grade 2R, ISHLT 2004). With modern immunosuppression grade 2R rejection has become a rare event, but the need remains for a technique that permits the discrimination of absent (grade 0R) and mild rejection (grade 1R). We therefore investigated whether an increase of magnetic field strength to 3T and the use of real-time navigator-gated respiration compensation allow for an increase in the sensitivity of T2 relaxation time detection that is necessary to achieve this discrimination. Methods: Eighteen patients received EMB (Tan et al., ArchPatholLabMed2007) and cardiac T2 mapping on the same day. Reading of T2 maps was blinded to the histological results. For final analysis, 3 cases with known 2R rejection at the time of T2 mapping were added, yielding 21 T2 mapping sessions. A respiration-navigator-gated radial gradient-recalled-echo pulse sequence (resolution 1.17 mm2, matrix 2562, trigger time 3 heartbeats, T2 preparation duration TET2 Prep = 60/30/0 ms) was applied to obtain 3 short-axis T2 maps (van Heeswijk et al., JACCCardiovascImaging2012), which were segmented according to AHA guidelines (Cerqueira et al, Circulation2001). The highest segmental T2 values were grouped according to histological rejection grade and differences were analyzed by Student's t-test, except for the non-blinded cases with 2R rejection. The degree of discrimination was determined using the Spearman's ranked correlation test. Results: The high-quality T2 maps allowed for visual differentiation of the rejection degrees (Figure 1), and the correlation of T2 mapping with the histological grade of acute cellular rejection was significant (Spearman's r = 0.56, p = 0.007). The 0R (n = 15) and 1R (n = 3) degrees demonstrated significantly different T2 values (46.9 ± 5.0 and 54.3 ± 3.0 ms, p = 0.02, Figure 2). Cases with 2R rejection showed clear T2 elevation (T2 = 60.3 ± 16.2 ms). Conclusions: This pilot study demonstrates that non-invasive free-breathing cardiac T2 mapping at 3T discriminates between no and mild cardiac allograft rejection. Confirmation of these encouraging results in a larger cohort should consider a study able to show equivalency or superiority of T2 mapping.
Resumo:
Työn tavoitteena oli selvittää tilannetta Euroopan automaattiteräsmarkkinoilla ja sen perusteella arvioida Imatra Steelin mahdollisuuksia kilpailla kyseessä olevilla markkinoilla. Tärkein tavoite oli kokonaismarkkinapotentiaalin arvioiminen Saksan, Ruotsin, Englannin ja Suomen markkinoilla. Lisäksi selvitettiin käytetyt automaattiteräslajit ja mitta-alue, hintataso sekä koneistukseenliittyviä teknisiä yksityiskohtia.Tavoitteena oli myös kartoittaa asenteita ja mielipiteitä mahdollisesta lyijyn käytön kieltämisestä teräksen seosaineena tulevaisuudessa. Paremman kokonaiskuvan saamiseksi analysoitiin myös kilpailutilannetta Euroopassa. Työn teoriakehyksessä tutkittiin teollisuustuotteiden markkinatutkimuksen suorittamisen erityispiirteitä, markkinapotentiaalin määrittämiseen liittyviä käsitteitä ja kilpailija-analyysin suorittamista. Empiirinen tutkimus suoritettiin pääasiassa asiantuntijoiden haastattelujen ja kyselyjen avulla. Haastateltavina oli tukkureita ja loppukäyttäjiä. Kilpailutilanteen kartoittaminen perustuu lähinnä sekundääriseen tietoon, Internet-sivuihin ja myyntikonttoreiden aikaisemmin keräämään tietoon.Automaattiterästen kokonaispotentiaaliksi Euroopassa arvioitiin miljoona tonnia ja suurin osa kaupasta käydään tutkituilla markkina-alueilla. Suurimmat volyymit sijoittuvat pienemmille mitta-alueille, Æ 12 - 50 mm. Markkinoita hallitsee muutama suuri teräksen valmistaja. Imatra Steel kohtuullisen pienenä toimittajana ei pysty kilpailemaan volyymilla ja tuotevalikoimallaan suurten teräsjättien kanssa. Imatra Steelin mahdollinen strategiavaihtoehto olisi yrittää löytää ne kapeat segmentit ja markkinaraot, joilla sen tuotteet jatietotaito tuovat asiakkaalle suurimman mahdollisen hyödyn verrattuna kilpailijoihin.
Resumo:
We study all the symmetries of the free Schr odinger equation in the non-commu- tative plane. These symmetry transformations form an infinite-dimensional Weyl algebra that appears naturally from a two-dimensional Heisenberg algebra generated by Galilean boosts and momenta. These infinite high symmetries could be useful for constructing non-relativistic interacting higher spin theories. A finite-dimensional subalgebra is given by the Schröodinger algebra which, besides the Galilei generators, contains also the dilatation and the expansion. We consider the quantization of the symmetry generators in both the reduced and extended phase spaces, and discuss the relation between both approaches.
Resumo:
We study all the symmetries of the free Schrödinger equation in the non-commu- tative plane. These symmetry transformations form an infinite-dimensional Weyl algebra that appears naturally from a two-dimensional Heisenberg algebra generated by Galilean boosts and momenta. These infinite high symmetries could be useful for constructing non-relativistic interacting higher spin theories. A finite-dimensional subalgebra is given by the Schröodinger algebra which, besides the Galilei generators, contains also the dilatation and the expansion. We consider the quantization of the symmetry generators in both the reduced and extended phase spaces, and discuss the relation between both approaches.
Resumo:
RATIONALE:We investigated the impact of canakinumab, a fully human anti-interleukin-1b monoclonal antibody on inflammation and HRQoL in gouty arthritis patients.METHODS: In this 8-week, single-blind, dose-ranging study, patients with acute gouty arthritis flares, unresponsive/intolerant or contraindicated to NSAIDs and/or colchicine were randomized to single subcutaneous canakinumab (10, 25, 50, 90, or 150mg, N5143) or single intramuscular triamcinolone acetonide (TA, 40mg, N557). Patients assessed pain (Likert scale), physicians assessed clinical signs of joint inflammation, and HRQoL was recorded using SF-36.RESULTS: At baseline, 98% patients had moderate-to-extreme pain, 85% had moderate/severe joint swelling, 64-79% had elevated inflammatory markers and HRQoL scores indicated impaired physical function. Percentage of patients with no/mild pain was numerically greater in most canakinumab groups vs. TA, 24-72h post-dose; difference significant for 150mg group at these time-points (P<0.05). Canakinumab 150mg was associated with significantly lower Likert scores for tenderness [OR, 3.2; 95% CI, 1.27-7.89; P50.014] and swelling (OR, 2.7; 95% CI, 1.09-6.50, P50.032) at 72h vs. TA; erythema was not different. Median CRP and SAA levels normalized by 7 days post-dose in most canakinumab groups, but remained elevated in TA. Physical function improved at 7 days postdose in all groups, highest improvement for canakinumab 150mg. SF-36 scores for physical functioning and bodily pain with canakinumab 150mg approached US general population scores by 7 days post-dose and exceeded normal values by 8 weeks post-dose.CONCLUSION: Canakinumab 150mg produced significantly greater and rapid pain-relief and improvements in HRQoL vs. TAin acute gouty arthritis patients.
Resumo:
The ratio of resting metabolic rate (RMR) to fat-free mass (FFM) is often used to compare individuals of different body sizes. Because RMR has not been well described over the full range of FFM, a literature review was conducted among groups with a wide range of FFM. It included 31 data sets comprising a total of 1111 subjects: 118 infants and preschoolers, 323 adolescents, and 670 adults; FFM ranged from 2.8 to 106 kg. The relationship of RMR to FFM was found to be nonlinear and average slopes of the regression equations of the three groups differed significantly (P less than 0.0001). For only the youngest group did the intercept approach zero. The lower slopes of RMR on FFM, at higher measures of FFM, corresponded to relatively greater proportions of less metabolically active muscle mass and to lesser proportions of more metabolically active nonmuscle organ mass. Because the contribution of FFM to RMR is not constant, an arithmetic error is introduced when the ratio of RMR to FFM is used. Hence, alternative methods should be used to compare individuals with markedly different FFM.
Resumo:
Breathing-induced bulk motion of the myocardium during data acquisition may cause severe image artifacts in coronary magnetic resonance angiography (MRA). Current motion compensation strategies include breath-holding or free-breathing MR navigator gating and tracking techniques. Navigator-based techniques have been further refined by the applications of sophisticated 2D k-space reordering techniques. A further improvement in image quality and a reduction of relative scanning duration may be expected from a 3D k-space reordering scheme. Therefore, a 3D k-space reordered acquisition scheme including a 3D navigator gated and corrected segmented k-space gradient echo imaging sequence for coronary MRA was implemented. This new zonal motion-adapted acquisition and reordering technique (ZMART) was developed on the basis of a numerical simulation of the Bloch equations. The technique was implemented on a commercial 1.5T MR system, and first phantom and in vivo experiments were performed. Consistent with the results of the theoretical findings, the results obtained in the phantom studies demonstrate a significant reduction of motion artifacts when compared to conventional (non-k-space reordered) gating techniques. Preliminary in vivo findings also compare favorably with the phantom experiments and theoretical considerations. Magn Reson Med 45:645-652, 2001.
Resumo:
Main goal of this thesis was to implement a localization system which uses sonars and WLAN intensity maps to localize an indoor mobile robot. A probabilistic localization method, Monte Carlo Localization is used in localization. Also the theory behind probabilistic localization is explained. Two main problems in mobile robotics, path tracking and global localization, are solved in this thesis. Implemented system can achieve acceptable performance in path tracking. Global localization using WLAN received signal strength information is shown to provide good results, which can be used to localize the robot accurately, but also some bad results, which are no use when trying to localize the robot to the correct place. Main goal of solving ambiguity in office like environment is achieved in many test cases.
Resumo:
Electronic canopy characterization is an important issue in tree crop management. Ultrasonic and optical sensors are the most used for this purpose. The objective of this work was to assess the performance of an ultrasonic sensor under laboratory and field conditions in order to provide reliable estimations of distance measurements to apple tree canopies. To this purpose, a methodology has been designed to analyze sensor performance in relation to foliage ranging and to interferences with adjacent sensors when working simultaneously. Results show that the average error in distance measurement using the ultrasonic sensor in laboratory conditions is ±0.53 cm. However, the increase of variability in field conditions reduces the accuracy of this kind of sensors when estimating distances to canopies. The average error in such situations is ±5.11 cm. When analyzing interferences of adjacent sensors 30 cm apart, the average error is ±17.46 cm. When sensors are separated 60 cm, the average error is ±9.29 cm. The ultrasonic sensor tested has been proven to be suitable to estimate distances to the canopy in field conditions when sensors are 60 cm apart or more and could, therefore, be used in a system to estimate structural canopy parameters in precision horticulture.
Resumo:
PURPOSE: To combine weighted iterative reconstruction with self-navigated free-breathing coronary magnetic resonance angiography for retrospective reduction of respiratory motion artifacts. METHODS: One-dimensional self-navigation was improved for robust respiratory motion detection and the consistency of the acquired data was estimated on the detected motion. Based on the data consistency, the data fidelity term of iterative reconstruction was weighted to reduce the effects of respiratory motion. In vivo experiments were performed in 14 healthy volunteers and the resulting image quality of the proposed method was compared to a navigator-gated reference in terms of acquisition time, vessel length, and sharpness. RESULT: Although the sampling pattern of the proposed method contained 60% more samples with respect to the reference, the scan efficiency was improved from 39.5 ± 10.1% to 55.1 ± 9.1%. The improved self-navigation showed a high correlation to the standard navigator signal and the described weighting efficiently reduced respiratory motion artifacts. Overall, the average image quality of the proposed method was comparable to the navigator-gated reference. CONCLUSION: Self-navigated coronary magnetic resonance angiography was successfully combined with weighted iterative reconstruction to reduce the total acquisition time and efficiently suppress respiratory motion artifacts. The simplicity of the experimental setup and the promising image quality are encouraging toward future clinical evaluation. Magn Reson Med 73:1885-1895, 2015. © 2014 Wiley Periodicals, Inc.