967 resultados para Extraoral Traction Appliances


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study compared the effectiveness of topical benzocaine 20% versus a combination of lidocaine, tetracaine, and phenylephrine in providing sufficient analgesia for the placement of orthodontic temporary anchorage devices (TADs). The 2 topical anesthetics were tested against each other bilaterally using a randomized, double-blind, crossover design. The agents were left in place for the amount of time prescribed by the manufacturer. The TAD was then placed, and each subject rated the degree of pain on a Heft-Parker visual analogue scale. A pulse oximeter was used to record the preoperative and postoperative pulse rates. Statistically significant differences in perceived pain (P < .05) and success rate (P < .01) between drugs were seen, but no significant difference in pulse rate change between the topical anesthetics was observed (P > .05). It was concluded that when the efficacy of topical benzocaine and of a combination product was compared as the sole anesthetic to facilitate acceptable pain control for placement of orthodontic temporary anchorage devices, the combination product was considerably more efficacious.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Orb-weaving spiders (Araneidae) are commonly regarded as generalist insect predators but resources provided by plants such as pollen may be an important dietary supplementation. Their webs snare insect prey, but can also trap aerial plankton like pollen and fungal spores. When recycling their orb webs, the spiders may therefore also feed on adhering pollen grains or fungal spores via extraoral digestion. In this study we measured stable isotope ratios in the bodies of two araneid species (Aculepeira ceropegia and Araneus diadematus), their potential prey and pollen to determine the relative contribution of pollen to their diet. We found that about 25% of juvenile orb-weaving spiders’ diet consisted of pollen, the other 75% of flying insects, mainly small dipterans and hymenopterans. The pollen grains in our study were too large to be taken up accidentally by the spiders and had first to be digested extraorally by enzymes in an active act of consumption. Therefore, pollen can be seen as a substantial component of the spiders’ diet. This finding suggests that these spiders need to be classified as omnivores rather than pure carnivores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE Geographic atrophy (GA) is the end-stage manifestation of atrophic age-related macular degeneration (AMD). The disease progresses slowly over time, eventually causing loss of central vision. Its cause and pathomechanism are not fully known. Previous studies have suggested that vitreoretinal traction (VRT) may contribute to the progression of neovascular AMD. The aim of this study was to examine whether an association between changes at the vitreoretinal interface (VRI), in particular traction (VRT), and the characteristics and progression of GA in eyes with dry AMD can be established. DESIGN Clinic-based prospective cohort study. PARTICIPANTS A total of 97 patients (age range, 61-90 years; mean, 78.4 years) with GA secondary to dry AMD were enrolled. Patients exhibiting neovascular signs on fluorescein angiography in either eye were excluded. METHODS The VRI changes were examined using spectral-domain optical coherence tomography (SD-OCT). Characteristics of GA were examined using fundus autofluorescence (FAF) imaging. All imaging was performed using a Spectralis SLO+OCT device (Heidelberg Engineering, Heidelberg, Germany); GA area was measured using the Region Finder (Heidelberg Engineering) software native to the Spectralis platform. MAIN OUTCOME MEASURES Area and increase in area of GA. RESULTS A total of 97 eyes were examined. Vitreoretinal traction was found in 39 eyes (40%). The GA area at baseline was 6.65±5.64 mm(2) in eyes with VRT and 5.73±4.72 mm(2) in eyes with no VRT. The annual rate of progression of GA area progression was 2.99±0.66 mm(2) in eyes with VRT and 1.45±0.67mm(2) in eyes without VRT. Differences between groups in both parameters were statistically significant (n = 97 total number of eyes; P<0.001). Multiple regression analysis confirmed this finding (B = 0.714, P<0.001; F3,93 = 72.542, P<0.001; adjusted R(2) = 0.691) CONCLUSIONS: Our results indicate an association between VRT and an increased rate of progression of GA area in dry AMD. Monitoring VRT may contribute to an improved estimate of the prospective time of visual loss and to a better timing of emerging therapies in dry AMD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study is to determine if quality of care, symptoms of depression, disease characteristics and quality of life of patients with amyotrophic lateral sclerosis (ALS) are related to requesting euthanasia or physician-assisted suicide (EAS) and dying due to EAS. Therefore, 102 ALS patients filled out structured questionnaires every 3 months until death and the results were correlated with EAS. Thirty-one percent of the patients requested EAS, 69 % of whom eventually died as a result of EAS (22 % of all patients). Ten percent died during continuous deep sedation; only one of them had explicitly requested death to be hastened. Of the patients who requested EAS, 86 % considered the health care to be good or excellent, 16 % felt depressed, 45 % experienced loss of dignity and 42 % feared choking. These percentages do not differ from the number of patients who did not explicitly request EAS. The frequency of consultations of professional caregivers and availability of appliances was similar in both groups. Our findings do not support continuous deep sedation being used as a substitute for EAS. In this prospective study, no evidence was found for a relation between EAS and the quality and quantity of care received, quality of life and symptoms of depression in patients with ALS. Our study does not support the notion that unmet palliative care needs are related to EAS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the fabrication, functionalization and testing of microdevices for cell culture and cell traction force measurements in three-dimensions (3D). The devices are composed of bent cantilevers patterned with cell-adhesive spots not lying on the same plane, and thus suspending cells in 3D. The cantilevers are soft enough to undergo micrometric deflections when cells pull on them, allowing cell forces to be measured by means of optical microscopy. Since individual cantilevers are mechanically independent of each other, cell traction forces are determined directly from cantilever deflections. This proves the potential of these new devices as a tool for the quantification of cell mechanics in a system with well-defined 3D geometry and mechanical properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The aim of the survey was to obtain information on the treatment plan preferences, mechanics and characteristics of temporary anchorage device (TAD) application using a single case presented to orthodontists in Switzerland. METHODS A structured questionnaire to be completed by all study participants with case-specific (treatment plan including mechanics and TAD usage) and general questions (general fixed appliance and TAD usage as well as professional, educational and demographic questions) together with an orthodontic borderline case was utilised. The case was a female adult with dental Class II/2, deep bite and maxillary anterior crowing, who had been treated in childhood with extraction of four premolars and fixed appliance followed by wisdom tooth extraction. RESULTS The response rate was 24.4% (108 out of 443). The majority (96.3%, 104) proposed comprehensive treatment, while 3.7% (4) planned only alignment of maxillary teeth. 8.3% (9) included a surgical approach in their treatment plan. An additional 0.9% (1) combined the surgical approach with Class II mechanics. 75.1% (81) decided on distalization on the maxilla using TADs, 7.4% (8) planned various types of Class II appliances and 3.7% (4) combined distalization using TADs or headgear with Class II appliances and surgery. Palatal implants were the most popular choice (70.6%, 60), followed by mini-screws (22.4%, 19) and mini-plates on the infrazygomatic crests (7.0%, 6). The preferred site of TAD insertion showed more variation in sagittal than in transversal dimension, and the median size of mini-screws used was 10.0-mm long (interquartile range (IQR) 2.3 mm) and 2.0-mm wide (IQR 0.3 mm). CONCLUSIONS Distalization against palatal implants and then distalization against mini-screws were the most popular treatment plans. Preferred site for TAD insertion varied depending on type and size but varied more widely in the sagittal than in the transversal dimension.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate potential occurrence of bacteremia in orthodontic patients after removal of miniscrews.The study group comprised 30 healthy subjects (17 males, 13 females) with a mean age of 24.1 years treated with self-ligating fixed appliances and mini-implant anchorage. Two 20 ml venous blood samples were obtained prior to and 30-60 seconds after miniscrew explantation following an aseptic technique. Blood culturing in aerobic and anaerobic conditions was carried out by means of the BACTEC blood culture analyzer. Microbiological analysis showed that none of the pre- and post-operative samples exhibited detectable bacteremia. Future research should be focused on determining the collective bacteremic effect of a sequence of orthodontic procedures including miniscrew placement or removal, typically performed during a single treatment session.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-ray imaging is one of the most commonly used medical imaging modality. Albeit X-ray radiographs provide important clinical information for diagnosis, planning and post-operative follow-up, the challenging interpretation due to its 2D projection characteristics and the unknown magnification factor constrain the full benefit of X-ray imaging. In order to overcome these drawbacks, we proposed here an easy-to-use X-ray calibration object and developed an optimization method to robustly find correspondences between the 3D fiducials of the calibration object and their 2D projections. In this work we present all the details of this outlined concept. Moreover, we demonstrate the potential of using such a method to precisely extract information from calibrated X-ray radiographs for two different orthopedic applications: post-operative acetabular cup implant orientation measurement and 3D vertebral body displacement measurement during preoperative traction tests. In the first application, we have achieved a clinically acceptable accuracy of below 1° for both anteversion and inclination angles, where in the second application an average displacement of 8.06±3.71 mm was measured. The results of both applications indicate the importance of using X-ray calibration in the clinical routine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM Preparation of the lamina during osteo-odonto-keratoprosthesis (OOKP) design is complex, and its longevity and watertightness important. To date, only acrylic bone cements have been used for bonding the optical cylinder to the tooth dentine. Our aim was to evaluate different dental adhesives for OOKP preparation. METHODS Specimens of bovine teeth were produced by preparing 1.5-mm thick dentine slices with holes having a diameter of 3.5 mm. Each group (n=10 per group) was luted with either classic poly-(methyl methacrylate) (PMMA) bone cement, universal resin cement or glass ionomer cement. All specimens underwent force measurement using a uniaxial traction machine. RESULTS The highest mean force required to break the bond was measured for PMMA bone cement (128.2 N) followed by universal resin cement (127.9 N), with no statistically significant difference. Glass ionomer cement showed significantly lower force resistance (78.1 N). CONCLUSIONS Excellent bonding strength combined with easy application was found for universal resin cement, and thus, it is a potential alternative to acrylic bone cement in OOKP preparation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS The aims of this double-blind, controlled, crossover study were to assess the influence of food preservatives on in situ dental biofilm growth and vitality, and to evaluate their influence on the ability of dental biofilm to demineralize underlying enamel over a period of 14 days. MATERIALS AND METHODS Twenty volunteers wore appliances with six specimens each of bovine enamel to build up intra-oral biofilms. During four test cycles of 14 days, the subjects had to place the appliance in one of the assigned controls or active solutions twice a day for a minute: negative control 0.9 % saline, 0.1 % benzoate (BA), 0.1 % sorbate (SA) and 0.2 % chlorhexidine (CHX positive control). After 14 days, the biofilms on two of the slabs were stained to visualize vital and dead bacteria to assess biofilm thickness (BT) and bacterial vitality (BV). Further, slabs were taken to determine mineral loss (ML), by quantitative light-induced laser fluorescence (QLF) and transversal microradiography (TMR), moreover the lesion depths (LD). RESULTS Nineteen subjects completed all test cycles. Use of SA, BA and CHX resulted in a significantly reduced BV compared to NaCl (p < 0.001). Only CHX exerted a statistically significant retardation in BT as compared to saline. Differences between SA and BA were not significant (p > 0.05) for both parameters. TMR analysis revealed the highest LD values in the NaCl group (43.6 ± 44.2 μm) and the lowest with CHX (11.7 ± 39.4 μm), while SA (22.9 ± 45.2 μm) and BA (21.4 ± 38.5 μm) lay in between. Similarly for ML, the highest mean values of 128.1 ± 207.3 vol% μm were assessed for NaCl, the lowest for CHX (-16.8 ± 284.2 vol% μm), while SA and BA led to values of 83.2 ± 150.9 and 98.4 ± 191.2 vol% μm, respectively. With QLF for both controls, NaCl (-33.8 ± 101.3 mm(2) %) and CHX (-16.9 ± 69.9 mm(2) %), negative values were recorded reflecting a diminution of fluorescence, while positive values were found with SA (33.9 ± 158.2 mm(2) %) and BA (24.8 ± 118.0 mm(2) %) depicting a fluorescence gain. These differences were non-significant (p > 0.05). CONCLUSION The biofilm model permited the assessment of undisturbed oral biofilm formation influenced by antibacterial components under clinical conditions for a period of 14 days. An effect of BA and SA on the demineralization of enamel could be demonstrated by TMR and QLF, but these new findings have to be seen as a trend. As part of our daily diet, these preservatives exert an impact on the metabolism of the dental biofilm, and therefore may even influence demineralization processes of the underlying dental enamel in situ.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Several biologically plausible mechanisms have been proposed to mediate the association between periodontitis and atherosclerotic vascular disease (AVD), including adverse effects on vascular endothelial function. Circulating endothelial progenitor cells (cEPCs) are known to contribute to vascular repair, but limited data are available regarding the relationship between cEPC levels and periodontitis. The aims of this cross-sectional study are to investigate the levels of hemangioblastic and monocytic cEPCs in patients with periodontitis and periodontally healthy controls and to associate cEPC levels with the extent and severity of periodontitis. METHODS A total of 112 individuals (56 patients with periodontitis and 56 periodontally healthy controls, aged 26 to 65 years; mean age: 43 years) were enrolled. All participants underwent a full-mouth periodontal examination and provided a blood sample. Hemangioblastic cEPCs were assessed using flow cytometry, and monocytic cEPCs were identified using immunohistochemistry in cultured peripheral blood mononuclear cells. cEPC levels were analyzed in the entire sample, as well as in a subset of 50 pairs of patients with periodontitis/periodontally healthy controls, matched with respect to age, sex, and menstrual cycle. RESULTS Levels of hemangioblastic cEPCs were approximately 2.3-fold higher in patients with periodontitis than periodontally healthy controls, after adjustments for age, sex, physical activity, systolic blood pressure, and body mass index (P = 0.001). A non-significant trend for higher levels of monocytic cEPCs in periodontitis was also observed. The levels of hemangioblastic cEPCs were positively associated with the extent of bleeding on probing, probing depth, and clinical attachment loss. Hemangioblastic and monocytic cEPC levels were not correlated (Spearman correlation coefficient 0.03, P = 0.77), suggesting that they represent independent populations of progenitor cells. CONCLUSION These findings further support the notion that oral infections have extraoral effects and document that periodontitis is associated with a mobilization of EPCs from the bone marrow, apparently in response to systemic inflammation and endothelial injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the effectiveness of fluorescence-based methods (DIAGNOdent, LF; DIAGNOdent pen, LFpen, and VistaProof fluorescence camera, FC) in detecting demineralization and remineralization on smooth surfaces in situ. Ten volunteers wore acrylic palatal appliances, each containing 6 enamel blocks that were demineralized for 14 days by exposure to a 20% sucrose solution and 3 of them were remineralized for 7 days with fluoride dentifrice. Sixty enamel blocks were evaluated at baseline, after demineralization and 30 blocks after remineralization by two examiners using LF, LFpen and FC. They were submitted to surface microhardness (SMH) and cross-sectional microhardness analysis. The integrated loss of surface hardness (ΔKHN) was calculated. The intraclass correlation coefficient for interexaminer reproducibility ranged from 0.21 (FC) to 0.86 (LFpen). SMH, LF and LFpen values presented significant differences among the three phases. However, FC fluorescence values showed no significant differences between the demineralization and remineralization phases. Fluorescence values for baseline, demineralized and remineralized enamel were, respectively, 5.4 ± 1.0, 9.2 ± 2.2 and 7.0 ± 1.5 for LF; 10.5 ± 2.0, 15.0 ± 3.2 and 12.5 ± 2.9 for LFpen, and 1.0 ± 0.0, 1.0 ± 0.1 and 1.0 ± 0.1 for FC. SMH and ΔKHN showed significant differences between demineralization and remineralization phases. There was a negative and significant correlation between SMH and LF and LFpen in the remineralization phase. In conclusion, LF and LFpen devices were effective in detecting demineralization and remineralization on smooth surfaces provoked in situ.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lumbar spinal instability (LSI) is a common spinal disorder and can be associated with substantial disability. The concept of defining clinically relevant classifications of disease or 'target condition' is used in diagnostic research. Applying this concept to LSI we hypothesize that a set of clinical and radiological criteria can be developed to identify patients with this target condition who are at high risk of 'irreversible' decompensated LSI for whom surgery becomes the treatment of choice. In LSI, structural deterioration of the lumbar disc initiates a degenerative cascade of segmental instability. Over time, radiographic signs become visible: traction spurs, facet joint degeneration, misalignment, stenosis, olisthesis and de novo scoliosis. Ligaments, joint capsules, local and distant musculature are the functional elements of the lumbar motion segment. Influenced by non-functional factors, these functional elements allow a compensation of degeneration of the motion segment. Compensation may happen on each step of the degenerative cascade but cannot reverse it. However, compensation of LSI may lead to an alleviation or resolution of clinical symptoms. In return, the target condition of decompensation of LSI may cause the new occurrence of symptoms and pain. Functional compensation and decompensation are subject to numerous factors that can change which makes estimation of an individual's long-term prognosis difficult. Compensation and decompensation may influence radiographic signs of degeneration, e.g. the degree of misalignment and segmental angulation caused by LSI is influenced by the tonus of the local musculature. This conceptual model of compensation/decompensation may help solve the debate on functional and psychosocial factors that influence low back pain and to establish a new definition of non-specific low back pain. Individual differences of identical structural disorders could be explained by compensated or decompensated LSI leading to changes in clinical symptoms and pain. Future spine surgery will have to carefully define and measure functional aspects of LSI, e.g. to identify a point of no return where multidisciplinary interventions do not allow a re-compensation and surgery becomes the treatment of choice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. For accurate resection of nonpalpable malignant breast lesions with a tumor-free resection rim, an exact and stable wire localization is essential. We tested the resistance towards traction force of different localization devices used in our clinic for breast lesions in two types of tissue. Materials and Methods. Eight different commercially available hook-wire devices were examined for resistance towards traction force using an analogue spring scale. Results. Most systems showed a high level of movement already under small traction force. Retractable systems with round hooks such as the Bard DuaLok , the Fil d'Ariane, and the RPLN Breast Localization Device withstood less traction force than the other systems. However, the Bard DuaLok system was very resistant towards a small traction force of 50 g when compared to the other systems. The Ultrawire Breast Localization Device withstood the most traction force in softer tissue and Kopans Breast Lesion Localization Needle withstood the most force in harder tissue. Conclusion. The Ultrawire Breast Localization Device and Kopans Breast Lesion Localization Needle withstood the most traction force. In general retractable systems withstand less traction force than nonretractable systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To assess the in vivo amount of BPA released from a visible light-cured orthodontic adhesive, immediately after bracket bonding. METHODS 20 orthodontic patients were recruited after obtaining informed consent. All patients received 24 orthodontic brackets in both dental arches. In Group A (11 patients), 25 ml of tap water were used for mouth rinsing, whereas in Group B (9 patients) a simulated mouth rinse formulation was used: a mixture of 20 ml de-ionized water plus 5 ml absolute ethanol. Rinsing solutions were collected before, immediately after placing the orthodontic appliances and after washing out the oral cavity and were then stored in glass tubes. Rinsing was performed in a single phase for 60s with the entire volume of each liquid. The BPA analysis was performed by gas chromatography-mass spectrometry. RESULTS An increase in BPA concentration immediately after the 1st post-bonding rinse was observed, for both rinsing media, which was reduced after the 2nd post-bonding rinse. Water exhibited higher levels of BPA concentration than water/ethanol after 1st and 2nd post-bonding rinses. Two-way mixed Repeated Measures ANOVA showed that the primary null hypothesis declaring mean BPA concentration to be equal across rinsing medium and rinsing status was rejected (p-value <0.001). The main effects of the rinsing medium and status, as well as their interaction were found to be statistically significant (p-values 0.048, <0.001 and 0.011 respectively). SIGNIFICANCE A significant pattern of increase of BPA concentration, followed by a decrease that reached the initial values was observed. The amount of BPA was relatively low and far below the reference limits of tolerable daily intake.