934 resultados para Evaluation of effectiveness bioinstrumental
Resumo:
OBJECTIVE To develop a model for evaluating the efficacy of drug-dispensing service in primary health care. METHODS An efficacy criterion was adopted to determine the level of achievement of the service objectives. The evaluation model was developed on the basis of a literature search and discussions with experts. The applicability test of the model was conducted in 15 primary health care units in the city of Florianópolis, state of Santa Catarina, in 2010, and data were recorded in structured and pretested questionnaires. RESULTS The model developed was evaluated using five dimensions of analysis for analysis. The model was suitable for evaluating service efficacy and helped to identify the critical points of each service dimension. CONCLUSIONS Adaptations to the data collection technique may be required to adjust for the reality and needs of each situation. The evaluation of the drug-dispensing service should promote adequate access to medications supplied through the public health system.
Resumo:
OBJECTIVE To assess the validity of dengue fever reports and how they relate to the definition of case and severity. METHODS Diagnostic test assessment was conducted using cross-sectional sampling from a universe of 13,873 patients treated during the fifth epidemiological period in health institutions from 11 Colombian departments in 2013. The test under analyses was the reporting to the National Public Health Surveillance System, and the reference standard was the review of histories identified by active institutional search. We reviewed all histories of patients diagnosed with dengue fever, as well as a random sample of patients with febrile syndromes. The specificity and sensitivity of reports were estimated for this purpose, considering the inverse of the probability of being selected for weighting. The concordance between reporting and the findings of the active institutional search was calculated using Kappa statistics. RESULTS We included 4,359 febrile patients, and 31.7% were classified as compatible with dengue fever (17 with severe dengue fever; 461 with dengue fever and warning signs; 904 with dengue fever and no warning signs). The global sensitivity of reports was 13.2% (95%CI 10.9;15.4) and specificity was 98.4% (95%CI 97.9;98.9). Sensitivity varied according to severity: 12.1% (95%CI 9.3;14.8) for patients presenting dengue fever with no warning signs; 14.5% (95%CI 10.6;18.4) for those presenting dengue fever with warning signs, and 40.0% (95%CI 9.6;70.4) for those with severe dengue fever. Concordance between reporting and the findings of the active institutional search resulted in a Kappa of 10.1%. CONCLUSIONS Low concordance was observed between reporting and the review of clinical histories, which was associated with the low reporting of dengue fever compatible cases, especially milder cases.
Resumo:
For musicians, the impact of noise exposure is not yet fully characterized. Some inconsistencies can be found in the methodology used to evaluate noise exposure. This study aims to analyze the noise exposure of musicians in a symphonic orchestra to understand their risk for hearing loss, applying the methodology proposed by ISO 9612:2009. Noise levels were monitored among musicians during the rehearsal of eight different repertoires. Test subjects were selected according to their instrument and position in the orchestra. Participants wore noise dosimeters throughout the rehearsals. A sound meter was used to analyze the exposure of the conductor. The results showed that musicians are exposed to high noise levels that can damage hearing. Brass, woodwind and percussion and timpani musicians were exposed to noise levels in excess of the upper exposure action level of 85 dB (A), while the other instrumental groups had a lower exposure action level of 80 dB (A). Percussion musicians were exposed to high peak noise levels of 135 dB (C). Sound levels varied by instrument, repertoire and position. Octave frequency analyses showed differences among musicians. This study suggests that musicians are at risk for hearing loss. There is a need for more effective guidelines applicable to all countries, which should define standardized procedures for determining musician noise exposure and should allow exposure level normalization to the year, including different repertoires.
Resumo:
An experimental and Finite Element study was performed on the bending behaviour of wood beams of the Pinus Pinaster species repaired with adhesively-bonded carbon–epoxy patches, after sustaining damage by cross-grain failure. This damage is characterized by crack growth at a small angle to the beams longitudinal axis, due to misalignment between the wood fibres and the beam axis. Cross-grain failure can occur in large-scale in a wood member when trees that have grown spirally or with a pronounced taper are cut for lumber. Three patch lengths were tested. The simulations include the possibility of cohesive fracture of the adhesive layer, failure within the wood beam in two propagation planes and patch interlaminar failure, by the use of cohesive zone modelling. The respective cohesive properties were estimated either by an inverse method or from the literature. The comparison with the tests allowed the validation of the proposed methodology, opening a good perspective for the reduction of costs in the design stages of these repairs due to extensive experimentation.
Resumo:
The widespread employment of carbon-epoxy laminates in high responsibility and severely loaded applications introduces an issue regarding their handling after damage. Repair of these structures should be evaluated, instead of their disposal, for cost saving and ecological purposes. Under this perspective, the availability of efficient repair methods is essential to restore the strength of the structure. The development and validation of accurate predictive tools for the repairs behaviour are also extremely important, allowing the reduction of costs and time associated to extensive test programmes. Comparing with strap repairs, scarf repairs have the advantages of a higher efficiency and the absence of aerodynamic disturbance. This work reports on a numerical study of the tensile behaviour of three-dimensional scarf repairs in carbon-epoxy structures, using a ductile adhesive (Araldite® 2015). The finite elements analysis was performed in ABAQUS® and Cohesive Zone Modelling was used for the simulation of damage onset and growth in the adhesive layer. Trapezoidal cohesive laws in each pure mode were used to account for the ductility of the specific adhesive mentioned. A parametric study was performed on the repair width and scarf angle. The use of over-laminating plies covering the repaired region at the outer or both repair surfaces was also tested as an attempt to increase the repairs efficiency. The obtained results allowed the proposal of design principles for repairing composite structures.
Resumo:
The disturbing emergence of multidrug-resistant strains of Mycobacterium tuberculosis (Mtb) has been driving the scientific community to urgently search for new and efficient antitubercular drugs. Despite the various drugs currently under evaluation, isoniazid is still the key and most effective component in all multi-therapeutic regimens recommended by the WHO. This paper describes the QSAR-oriented design, synthesis and in vitro antitubercular activity of several potent isoniazid derivatives (isonicotinoyl hydrazones and isonicotinoyl hydrazides) against H37Rv and two resistant Mtb strains. QSAR studies entailed RFs and ASNNs classification models, as well as MLR models. Strict validation procedures were used to guarantee the models' robustness and predictive ability. Lipophilicity was shown not to be relevant to explain the activity of these derivatives, whereas shorter N-N distances and lengthy substituents lead to more active compounds. Compounds I, 2, 4, 5 and 6, showed measured activities against H37Rv higher than INH (i.e., MIC <= 0.28 mu M), while compound 9 exhibited a six fold decrease in MIC against the katG (S315T) mutated strain, by comparison with INH (Le., 6.9 vs. 43.8 mu M). All compounds were ineffective against H37Rv(INH) (Delta katG), a strain with a full deletion of the katG gene, thus corroborating the importance of KatG in the activation of INH-based compounds. The most potent compounds were also shown not to be cytotoxic up to a concentration 500 times higher than MIC. (C) 2014 Elsevier Masson SAS. All rights reserved.
Resumo:
The effect of intracellular reduced glutathione (GSH) in the lead stress response of Saccharomyces cerevisiae was investigated. Yeast cells exposed to Pb, for 3 h, lost the cell proliferation capacity (viability) and decreased intracellular GSH level. The Pb-induced loss of cell viability was compared among yeast cells deficient in GSH1 (∆gsh1) or GSH2 (∆gsh2) genes and wild-type (WT) cells. When exposed to Pb, ∆gsh1 and ∆gsh2 cells did not display an increased loss of viability, compared with WT cells. However, the depletion of cellular thiols, including GSH, by treatment of WT cells with iodoacetamide (an alkylating agent, which binds covalently to thiol group), increased the loss of viability in Pb-treated cells. In contrast, GSH enrichment, due to the incubation of WT cells with amino acids mixture constituting GSH (l-glutamic acid, l-cysteine and glycine), reduced the Pb-induced loss of proliferation capacity. The obtained results suggest that intracellular GSH is involved in the defence against the Pb-induced toxicity; however, at physiological concentration, GSH seems not to be sufficient to prevent the Pb-induced loss of cell viability.
Resumo:
This paper proposes an online mechanism that can evaluate the sensitivity of single event upsets (SEUs) of field programmable gate arrays (FPGAs). The online detection mechanism cyclically reads and compares the values form the external and internal configuration memories, taking into account the mask information. This remote detection method also signals any mismatch as a result of a SEU that affects both used and not-used FPGA parts, which maximizes the monitored area. By utilizing an external, Web-accessible controller that is connected to the test infrastructure, the possibility of running the same operation in a remote manner is enabled. Moreover, the need for a local memory to store the mask values is also eliminated.
Resumo:
OBJECTIVE To analyze if size, administrative level, legal status, type of unit and educational activity influence the hospital network performance in providing services to the Brazilian Unified Health System.METHODS This cross-sectional study evaluated data from the Hospital Information System and the Cadastro Nacional de Estabelecimentos de Saúde (National Registry of Health Facilities), 2012, in Sao Paulo, Southeastern Brazil. We calculated performance indicators, such as: the ratio of hospital employees per bed; mean amount paid for admission; bed occupancy rate; average length of stay; bed turnover index and hospital mortality rate. Data were expressed as mean and standard deviation. The groups were compared using analysis of variance (ANOVA) and Bonferroni correction.RESULTS The hospital occupancy rate in small hospitals was lower than in medium, big and special-sized hospitals. Higher hospital occupancy rate and bed turnover index were observed in hospitals that include education in their activities. The hospital mortality rate was lower in specialized hospitals compared to general ones, despite their higher proportion of highly complex admissions. We found no differences between hospitals in the direct and indirect administration for most of the indicators analyzed.CONCLUSIONS The study indicated the importance of the scale effect on efficiency, and larger hospitals had a higher performance. Hospitals that include education in their activities had a higher operating performance, albeit with associated importance of using human resources and highly complex structures. Specialized hospitals had a significantly lower rate of mortality than general hospitals, indicating the positive effect of the volume of procedures and technology used on clinical outcomes. The analysis related to the administrative level and legal status did not show any significant performance differences between the categories of public hospitals.
Resumo:
It is already more than 10 years that weblabs are seen as important resources to provide the experimental work required in engineering education. Several weblabs have been applied in engineering courses, but there are still unsolved problems related to the development of their infrastructures. For solving some of those problems, it was implemented a weblab with a reconfigurable infrastructure compliant with the IEEE1451.0 Std. and supported by Field Programmable Gate Array (FPGA) technology. This paper presents the referred weblab, and provides and analyses a set of researchers' opinions about the implemented infrastructure, and the adopted methodology for the conduction of real experiments.
Resumo:
Thesis submitted to the Faculdade de Ciências e Tecnologia to obtain the Master’s degree in Environmental Engineering, profile in Ecological Engineering
Resumo:
The main goals of the present work are the evaluation of the influence of several variables and test parameters on the melt flow index (MFI) of thermoplastics, and the determination of the uncertainty associated with the measurements. To evaluate the influence of test parameters on the measurement of MFI the design of experiments (DOE) approach has been used. The uncertainty has been calculated using a "bottom-up" approach given in the "Guide to the Expression of the Uncertainty of Measurement" (GUM). Since an analytical expression relating the output response (MFI) with input parameters does not exist, it has been necessary to build mathematical models by adjusting the experimental observations of the response variable in accordance with each input parameter. Subsequently, the determination of the uncertainty associated with the measurement of MFI has been performed by applying the law of propagation of uncertainty to the values of uncertainty of the input parameters. Finally, the activation energy (Ea) of the melt flow at around 200 degrees C and the respective uncertainty have also been determined.
Resumo:
Drilling of carbon fibre/epoxy laminates is usually carried out using standard drills. However, it is necessary to adapt the processes and/or tooling as the risk of delamination, or other damages, is high. These problems can affect mechanical properties of produced parts, therefore, lower reliability. In this paper, four different drills – three commercial and a special step (prototype) – are compared in terms of thrust force during drilling and delamination. In order to evaluate damage, enhanced radiography is applied. The resulting images were then computational processed using a previously developed image processing and analysis platform. Results show that the prototype drill had encouraging results in terms of maximum thrust force and delamination reduction. Furthermore, it is possible to state that a correct choice of drill geometry, particularly the use of a pilot hole, a conservative cutting speed – 53 m/min – and a low feed rate – 0.025 mm/rev – can help to prevent delamination.
Resumo:
Additional apple juice extraction with pulsed electric field pretreated apple cubes towards control samples is evaluated. Monopolar and bipolar shaped pulses are compared and their effect is studied with variation of electric field, pulse width and number of pulses. Variation of electric field strength is ranged from 100 V/cm to 1300 V/cm, pulse width from 20 mu s to 300 mu s and number of pulses from 10 to 200, at frequency of 200Hz. Two pulse trains separated by 1 second are applied to all samples. Bipolar pulses showed higher apple juice yields with all studied parameters. Calculation of specific energies consumed was assessed and a threshold where higher energy inputs do not increase juice yield is found for a number of used parameters. Qualitative parameters of total soluble matter (Brix) and absorbance at 390 nm wavelength were determined for each sample and results show that no substantial differences are found for PEF pre-treated and control samples.