892 resultados para Energy consumption -- Computer simulation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy auditing can be an important contribution for identification and assessment of energy conservation measures (ECMs) in buildings. Numerous tools and software have been developed, with varying degree of precision and complexity and different areas of use.   This paper evaluates PHPP as a versatile, easy-to-use energy auditing tool and gives examples of how it has been compared to a dynamic simulation tool, within the EU-project iNSPiRe. PHPP is a monthly balance energy calculation tool based on EN13790. It is intended for assisting the design of Passive Houses and energy renovation projects and as guidance in the choice of appropriate ECMs.   PHPP was compared against the transient simulation software TRNSYS for a single family house and a multi-family house. It should be mentioned that dynamic building simulations might strongly depend on the model assumptions and simplifications compared to reality, such as ideal heating or real heat emission system. Setting common boundary conditions for both PHPP and TRNSYS, the ideal heating and cooling loads and demands were compared on monthly and annual basis for seven European locations and buildings with different floor area, S/V ratio, U-values and glazed area of the external walls.   The results show that PHPP can be used to assess the heating demand of single-zone buildings and the reduction of heating demand with ECMs with good precision. The estimation of cooling demand is also acceptable if an appropriate shading factor is applied in PHPP. In general, PHPP intentionally overestimates heating and cooling loads, to be on the safe side for system sizing. Overall, the agreement with TRNSYS is better in cases with higher quality of the envelope as in cold climates and for good energy standards. As an energy auditing tool intended for pre-design it is a good, versatile and easy-to-use alternative to more complex simulation tools.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract—With the proliferation of Software systems and the rise of paradigms such the Internet of Things, Cyber- Physical Systems and Smart Cities to name a few, the energy consumed by software applications is emerging as a major concern. Hence, it has become vital that software engineers have a better understanding of the energy consumed by the code they write. At software level, work so far has focused on measuring the energy consumption at function and application level. In this paper, we propose a novel approach to measure energy consumption at a feature level, cross-cutting multiple functions, classes and systems. We argue the importance of such measurement and the new insight it provides to non-traditional stakeholders such as service providers. We then demonstrate, using an experiment, how the measurement can be done with a combination of tools, namely our program slicing tool (PORBS) and energy measurement tool (Jolinar).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente trabalho realizou-se no âmbito do Projeto Galp 20-2020 implementado na empresa Sanindusa, em parceira com a Universidade de Aveiro. Como principal objetivo pretendia-se estudar o consumo de energia durante o processo de cozedura das peças cerâmicas com o intuito de avaliar a viabilidade da substituição do refratário existente na empresa. Uma vez que esta medida implicaria um tempo de retorno do investimento demasiado elevado, optou-se por estudar o consumo de energia associado a uma placa horizontal, de massa unitária, de qualquer tipo de material refratário. Para tal, foi desenvolvido um Modelo Teórico capaz de calcular o calor absorvido por uma placa de refratário ao longo de todo o percurso dentro do Forno Túnel 2, existente na empresa e utilizado no processo de produção das peças cerâmicas. Através deste estudo foi possível concluir que o Modelo Teórico é bastante útil na medida em que permite a criação de vários cenários, através da alteração de diversas variáveis, permitindo conhecer qual o impacto de cada uma no consumo de energia neste equipamento. Como trabalho futuro propõe-se o desenvolvimento do Modelo Teórico apresentado para o estudo da transferência de calor bidimensional. Esta melhoria permitiria analisar o consumo de energia associado a diferentes formas de material refratário utilizado no processo de cozedura de peças cerâmicas (o que não é possível quando se aplica o conceito de transferência de calor unidimensional).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis aims to describe and demonstrate the developed concept to facilitate the use of thermal simulation tools during the building design process. Despite the impact of architectural elements on the performance of buildings, some influential decisions are frequently based solely on qualitative information. Even though such design support is adequate for most decisions, the designer will eventually have doubts concerning the performance of some design decisions. These situations will require some kind of additional knowledge to be properly approached. The concept of designerly ways of simulating focuses on the formulation and solution of design dilemmas, which are doubts about the design that cannot be fully understood nor solved without using quantitative information. The concept intends to combine the power of analysis from computer simulation tools with the capacity of synthesis from architects. Three types of simulation tools are considered: solar analysis, thermal/energy simulation and CFD. Design dilemmas are formulated and framed according to the architect s reflection process about performance aspects. Throughout the thesis, the problem is investigated in three fields: professional, technical and theoretical fields. This approach on distinct parts of the problem aimed to i) characterize different professional categories with regards to their design practice and use of tools, ii) investigate preceding researchers on the use of simulation tools and iii) draw analogies between the proposed concept, and some concepts developed or described in previous works about design theory. The proposed concept was tested in eight design dilemmas extracted from three case studies in the Netherlands. The three investigated processes are houses designed by Dutch architectural firms. Relevant information and criteria from each case study were obtained through interviews and conversations with the involved architects. The practical application, despite its success in the research context, allowed the identification of some applicability limitations of the concept, concerning the architects need to have technical knowledge and the actual evolution stage of simulation tools

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente relatório resulta de um estágio realizado no âmbito da eficiência energética assente no programa Galp 20-20-20 que tem por génese uma parceria entre a Universidade de Aveiro e a empresa de coberturas cerâmicas, CS – Coelho da Silva S.A. A Fábrica alvo de estudo é uma consumidora intensiva de energia, despendeu no ano de 2013 cerca de 3.768 tep. Devido aos seus processos de cozedura e secagem, apresenta uma elevada dependência de Gás Natural, representando pouco mais de 78% do consumo global da fábrica. Deste consumo de energia térmica, 83% respeita ao forno e os restantes 17% encontram-se alocados ao secador, pelo que as medidas de eficiência energética presentes neste relatório centram-se da redução deste vetor energético. São então propostas três medidas para a redução da dependência deste vetor. A primeira, incide na recuperação de calor residual presente nos gases de exaustão através da instalação de um permutador de calor. Esta medida permite uma redução do consumo na ordem dos 10% e conta com um payback de 2,3 anos resultante de uma economia anual de 150.000 €. Para este estudo foi desenvolvido um modelo dinâmico em excel que permite a simulação de diversos cenários. São também propostas mais duas intervenções que incidem na alteração do circuito térmico. Estas medidas têm um impacte mais reduzido no que respeita ao percentual de redução energético, ambas com menos de 1% de redução do consumo global da fábrica. Contudo são medidas bastante interessantes dada a sua simplicidade e contam com poupanças anuais na ordem dos 6.000 € que resultam num payback inferior a 2 meses. Paralelamente executaram-se dois estudos para a iluminação, o primeiro sugere a instalação de um modelador de tensão que reduz a potência de iluminação em 36%, implicando uma redução da iluminância de cerca de 5%. A redução da potência resulta numa economia energética na ordem dos 0,4% da energia global da instalação. Este equipamento poderá ser adquirido por completo ou em renting. Ao optar pela compra integral, o investimento será apenas ressarcido em 2,8 anos resultante de uma poupança anula de perto de 6.500 €. Caso seja por renting este não tem qualquer custo adicional e as economias monetárias são partilhadas entre a empresa que fornece o equipamento e a CS-Coelho da Silva, S.A. Por fim é sugerida a substituição de parte da iluminação atual da fábrica por tecnologia LED, com esta medida reduz-se o consumo global em 0,76%. Esta medida gera uma economia monetária na ordem dos 11.500 € sendo ressarcida em 2,1 anos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Public Lightning is an important part of municipality’s nighttime landscape. Lighting can be used to enhance public safety and security while improving the aesthetic appeal of the surrounding properties but with the current global financial crisis, such lighting systems must also be sustainable. Most climate policy efforts focus on the state and international level, however national governments won’t be able to meet their international commitments without local action. In Portugal, the Public Lighting is responsible for 3% of energy consumption. The problem is that the trend is to increase (about 4-5% per year) which represents very high costs for the municipal authorities. In terms of numbers are analyzed in this thesis 45 of 278 existent in Continental Portugal what represents only 16,2 % of the counties. This where the local authorities in Portugal that had a Sustainable Energy Action Plan (SEAP) that had been accepted and made available in the Covenant of Mayors website until the end of year 2013. It is important that the Covenant of Mayors will increase the local authorities awareness for energy efficiency and especially to public lighting because there is still a long way to go in terms of energy consumption reduction. In future works it would be interesting to see the payback of the EolGreen post in a real scenario due to lack of energy consumption from the grid it would allow to have a pretty high initial investment even with the maintenance that those technologies need.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The building envelope is the principal mean of interaction between indoors and environment, with direct influence on thermal and energy performance of the building. By intervening in the envelope, with the proposal of specific architectural elements, it is possible to promote the use of passive strategies of conditioning, such as natural ventilation. The cross ventilation is recommended by the NBR 15220-3 as the bioclimatic main strategy for the hot and humid climate of Natal/RN, offering among other benefits, the thermal comfort of occupants. The analysis tools of natural ventilation, on the other hand, cover a variety of techniques, from the simplified calculation methods to computer fluid dynamics, whose limitations are discussed in several papers, but without detailing the problems encountered. In this sense, the present study aims to evaluate the potential of wind catchers, envelope elements used to increase natural ventilation in the building, through CFD simplified simulation. Moreover, it seeks to quantify the limitations encountered during the analysis. For this, the procedure adopted to evaluate the elements implementation and efficiency was the CFD simulation, abbreviation for Computer Fluid Dynamics, with the software DesignBuilder CFD. It was defined a base case, where wind catchers were added with various settings, to compare them with each other and appreciate the differences in flows and air speeds encountered. Initially there has been done sensitivity tests for familiarization with the software and observe simulation patterns, mapping the settings used and simulation time for each case simulated. The results show the limitations encountered during the simulation process, as well as an overview of the efficiency and potential of wind catchers, with the increase of ventilation with the use of catchers, differences in air flow patterns and significant increase in air speeds indoors, besides changes found due to different element geometries. It is considered that the software used can help designers during preliminary analysis in the early stages of design

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The high performance computing community has traditionally focused uniquely on the reduction of execution time, though in the last years, the optimization of energy consumption has become a main issue. A reduction of energy usage without a degradation of performance requires the adoption of energy-efficient hardware platforms accompanied by the development of energy-aware algorithms and computational kernels. The solution of linear systems is a key operation for many scientific and engineering problems. Its relevance has motivated an important amount of work, and consequently, it is possible to find high performance solvers for a wide variety of hardware platforms. In this work, we aim to develop a high performance and energy-efficient linear system solver. In particular, we develop two solvers for a low-power CPU-GPU platform, the NVIDIA Jetson TK1. These solvers implement the Gauss-Huard algorithm yielding an efficient usage of the target hardware as well as an efficient memory access. The experimental evaluation shows that the novel proposal reports important savings in both time and energy-consumption when compared with the state-of-the-art solvers of the platform.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current energy market requires urgent revision for the introduction of renewable, less-polluting and inexpensive energy sources. Biohydrogen (bioH2) is considered to be one of the most appropriate options for this model shift, being easily produced through the anaerobic fermentation of carbohydrate-containing biomass. Ideally, the feedstock should be low-cost, widely available and convertible into a product of interest. Microalgae are considered to possess the referred properties, being also highly valued for their capability to assimilate CO2 [1]. The microalga Spirogyra sp. is able to accumulate high concentrations of intracellular starch, a preferential carbon source for some bioH2 producing bacteria such as Clostridium butyricum [2]. In the present work, Spirogyra biomass was submitted to acid hydrolysis to degrade polymeric components and increase the biomass fermentability. Initial tests of bioH2 production in 120 mL reactors with C. butyricum yielded a maximum volumetric productivity of 141 mL H2/L.h and a H2 production yield of 3.78 mol H2/mol consumed sugars. Subsequently, a sequential batch reactor (SBR) was used for the continuous H2 production from Spirogyra hydrolysate. After 3 consecutive batches, the fermentation achieved a maximum volumetric productivity of 324 mL H2/L.h, higher than most results obtained in similar production systems [3] and a potential H2 production yield of 10.4 L H2/L hydrolysate per day. The H2 yield achieved in the SBR was 2.59 mol H2/mol, a value that is comparable to those attained with several thermophilic microorganisms [3], [4]. In the present work, a detailed energy consumption of the microalgae value-chain is presented and compared with previous results from the literature. The specific energy requirements were determined and the functional unit considered was gH2 and MJH2. It was possible to identify the process stages responsible for the highest energy consumption during bioH2 production from Spirogyra biomass for further optimisation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Urban retrofit is becoming increasingly established as one of the most effective solutions to contain the energy consumption of the existing building stock, to reduce vulnerability to natural and man-made risk and generally improve the quality of built space. However, the planning of retrofit interventions at urban scale should take account of the actual feasibility of measures lest they remain only on paper. This contribution supplies an overview of the many issues related to the subject of urban regeneration, proposing a procedure to identify practical interventions to minimize costs and maximize benefits, in terms of energy efficiency, an increase in resilience and improvement in the quality of the building stock. This procedure was applied to a case study of a neighborhood in the city of Naples, a high-density urban area which is particularly vulnerable to volcanic and seismic risk, and to risks due to climate change.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Traditional air delivery to high-bay buildings involves ceiling level supply and return ducts that create an almost-uniform temperature in the space. Problems with this system include potential recirculation of supply air and higher-than-necessary return air temperatures. A new air delivery strategy was investigated that involves changing the height of conventional supply and return ducts to have control over thermal stratification in the space. A full-scale experiment using ten vertical temperature profiles was conducted in a manufacturing facility over one year. The experimental data was utilized to validated CFD and EnergyPlus models. CFD simulation results show that supplying air directly to the occupied zone increases stratification while holding thermal comfort constant during the cooling operation. The building energy simulation identified how return air temperature offset, set point offset, and stratification influence the building’s energy consumption. A utility bill analysis for cooling shows 28.8% HVAC energy savings while the building energy simulation shows 19.3 – 37.4% HVAC energy savings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We apply Agent-Based Modeling and Simulation (ABMS) to investigate a set of problems in a retail context. Specifically, we are working to understand the relationship between human resource management practices and retail productivity. Despite the fact we are working within a relatively novel and complex domain, it is clear that intelligent agents do offer potential for developing organizational capabilities in the future. Our multi-disciplinary research team has worked with a UK department store to collect data and capture perceptions about operations from actors within departments. Based on this case study work, we have built a simulator that we present in this paper. We then use the simulator to gather empirical evidence regarding two specific management practices: empowerment and employee development.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The evolution of wireless communication systems leads to Dynamic Spectrum Allocation for Cognitive Radio, which requires reliable spectrum sensing techniques. Among the spectrum sensing methods proposed in the literature, those that exploit cyclostationary characteristics of radio signals are particularly suitable for communication environments with low signal-to-noise ratios, or with non-stationary noise. However, such methods have high computational complexity that directly raises the power consumption of devices which often have very stringent low-power requirements. We propose a strategy for cyclostationary spectrum sensing with reduced energy consumption. This strategy is based on the principle that p processors working at slower frequencies consume less power than a single processor for the same execution time. We devise a strict relation between the energy savings and common parallel system metrics. The results of simulations show that our strategy promises very significant savings in actual devices.