861 resultados para Electronic voting


Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARY There is interest in the potential of companion animal surveillance to provide data to improve pet health and to provide early warning of environmental hazards to people. We implemented a companion animal surveillance system in Calgary, Alberta and the surrounding communities. Informatics technologies automatically extracted electronic medical records from participating veterinary practices and identified cases of enteric syndrome in the warehoused records. The data were analysed using time-series analyses and a retrospective space-time permutation scan statistic. We identified a seasonal pattern of reports of occurrences of enteric syndromes in companion animals and four statistically significant clusters of enteric syndrome cases. The cases within each cluster were examined and information about the animals involved (species, age, sex), their vaccination history, possible exposure or risk behaviour history, information about disease severity, and the aetiological diagnosis was collected. We then assessed whether the cases within the cluster were unusual and if they represented an animal or public health threat. There was often insufficient information recorded in the medical record to characterize the clusters by aetiology or exposures. Space-time analysis of companion animal enteric syndrome cases found evidence of clustering. Collection of more epidemiologically relevant data would enhance the utility of practice-based companion animal surveillance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antimicrobial drugs may be used to treat diarrheal illness in companion animals. It is important to monitor antimicrobial use to better understand trends and patterns in antimicrobial resistance. There is no monitoring of antimicrobial use in companion animals in Canada. To explore how the use of electronic medical records could contribute to the ongoing, systematic collection of antimicrobial use data in companion animals, anonymized electronic medical records were extracted from 12 participating companion animal practices and warehoused at the University of Calgary. We used the pre-diagnostic, clinical features of diarrhea as the case definition in this study. Using text-mining technologies, cases of diarrhea were described by each of the following variables: diagnostic laboratory tests performed, the etiological diagnosis and antimicrobial therapies. The ability of the text miner to accurately describe the cases for each of the variables was evaluated. It could not reliably classify cases in terms of diagnostic tests or etiological diagnosis; a manual review of a random sample of 500 diarrhea cases determined that 88/500 (17.6%) of the target cases underwent diagnostic testing of which 36/88 (40.9%) had an etiological diagnosis. Text mining, compared to a human reviewer, could accurately identify cases that had been treated with antimicrobials with high sensitivity (92%, 95% confidence interval, 88.1%-95.4%) and specificity (85%, 95% confidence interval, 80.2%-89.1%). Overall, 7400/15,928 (46.5%) of pets presenting with diarrhea were treated with antimicrobials. Some temporal trends and patterns of the antimicrobial use are described. The results from this study suggest that informatics and the electronic medical records could be useful for monitoring trends in antimicrobial use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four new tetrathiafulvalene (TTF)-based dyes featured with a donor–bridge–acceptor (D–π–A) structure were synthesized and characterized. All of them undergo two reversible oxidations to form stable radical cation and dication species. The electronic interactions between the TTF donor and the cyanoacrylic acid acceptor through the different π-linkers have been demonstrated by the presence of a photo-induced intramolecular charge-transfer (ICT) absorption band in the visible region. A red shift of the ICT state can be finely tuned by the degree of aromaticity and extended conjugation of π-bridges. To some extent, the oxidation potentials of these dyes are affected by the nature of π-bridges. They have been applied in organic dye-sensitized solar cells, showing relatively low power conversion efficiencies of up to 0.87% due to substantial charge recombination losses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.