978 resultados para Electron beam tomography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of basis set superposition error (BSSE) on molecular complexes is analyzed. The BSSE causes artificial delocalizations which modify the first order electron density. The mechanism of this effect is assessed for the hydrogen fluoride dimer with several basis sets. The BSSE-corrected first-order electron density is obtained using the chemical Hamiltonian approach versions of the Roothaan and Kohn-Sham equations. The corrected densities are compared to uncorrected densities based on the charge density critical points. Contour difference maps between BSSE-corrected and uncorrected densities on the molecular plane are also plotted to gain insight into the effects of BSSE correction on the electron density

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantum molecular similarity (QMS) techniques are used to assess the response of the electron density of various small molecules to application of a static, uniform electric field. Likewise, QMS is used to analyze the changes in electron density generated by the process of floating a basis set. The results obtained show an interrelation between the floating process, the optimum geometry, and the presence of an external field. Cases involving the Le Chatelier principle are discussed, and an insight on the changes of bond critical point properties, self-similarity values and density differences is performed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The level of ab initio theory which is necessary to compute reliable values for the static and dynamic (hyper)polarizabilities of three medium size π-conjugated organic nonlinear optical (NLO) molecules is investigated. With the employment of field-induced coordinates in combination with a finite field procedure, the calculations were made possible. It is stated that to obtain reasonable values for the various individual contributions to the (hyper)polarizability, it is necessary to include electron correlation. Based on the results, the convergence of the usual perturbation treatment for vibrational anharmonicity was examined

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electronic coupling Vda is one of the key parameters that determine the rate of charge transfer through DNA. While there have been several computational studies of Vda for hole transfer, estimates of electronic couplings for excess electron transfer (ET) in DNA remain unavailable. In the paper, an efficient strategy is established for calculating the ET matrix elements between base pairs in a π stack. Two approaches are considered. First, we employ the diabatic-state (DS) method in which donor and acceptor are represented with radical anions of the canonical base pairs adenine-thymine (AT) and guanine-cytosine (GC). In this approach, similar values of Vda are obtained with the standard 6-31 G* and extended 6-31++ G* basis sets. Second, the electronic couplings are derived from lowest unoccupied molecular orbitals (LUMOs) of neutral systems by using the generalized Mulliken-Hush or fragment charge methods. Because the radical-anion states of AT and GC are well reproduced by LUMOs of the neutral base pairs calculated without diffuse functions, the estimated values of Vda are in good agreement with the couplings obtained for radical-anion states using the DS method. However, when the calculation of a neutral stack is carried out with diffuse functions, LUMOs of the system exhibit the dipole-bound character and cannot be used for estimating electronic couplings. Our calculations suggest that the ET matrix elements Vda for models containing intrastrand thymine and cytosine bases are essentially larger than the couplings in complexes with interstrand pyrimidine bases. The matrix elements for excess electron transfer are found to be considerably smaller than the corresponding values for hole transfer and to be very responsive to structural changes in a DNA stack

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iterative image reconstruction algorithms provide significant improvements over traditional filtered back projection in computed tomography (CT). Clinically available through recent advances in modern CT technology, iterative reconstruction enhances image quality through cyclical image calculation, suppressing image noise and artifacts, particularly blooming artifacts. The advantages of iterative reconstruction are apparent in traditionally challenging cases-for example, in obese patients, those with significant artery calcification, or those with coronary artery stents. In addition, as clinical use of CT has grown, so have concerns over ionizing radiation associated with CT examinations. Through noise reduction, iterative reconstruction has been shown to permit radiation dose reduction while preserving diagnostic image quality. This approach is becoming increasingly attractive as the routine use of CT for pediatric and repeated follow-up evaluation grows ever more common. Cardiovascular CT in particular, with its focus on detailed structural and functional analyses, stands to benefit greatly from the promising iterative solutions that are readily available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We diagnosed a non-small cell lung carcinoma in a 49-year-old female patient with the histopathological diagnosis of stage IIIB mixed bronchioloalveolar and papillary adenocarcinoma with extensive micropapillary feature, which was not visualized on the preoperative multimodality imaging with positron emission tomography (PET) and computed tomography (CT). The micropapillary component characterized by a unique growth pattern with particular morphological features can be observed in all subtypes of lung adenocarcinoma. Micropapillary component is increasingly recognized as a distinct entity associated with higher aggressiveness. Even the most modern multimodality PET/CT imaging technology may fail to adequately visualize this important component with highly relevant prognostic implications. Thus, the pathologist needs to consciously look for a micropapillary component in the surgical specimen or in preoperative biopsies or cytology. This may have potential future treatment implications, as adjuvant or neoadjuvant chemotherapy may be of relevance, even in the early stages of the disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and MRI are used for detecting liver metastases from uveal melanoma. The introduction of new treatment options in clinical trials might benefit from early response assessment. Here, we determine the value of FDG-PET/CT with respect to MRI at diagnosis and its potential for monitoring therapy. MATERIAL AND METHODS: Ten patients with biopsy-proven liver metastases of uveal melanoma enrolled in a randomized phase III trial (NCT00110123) underwent both FDG-PET coupled with unenhanced CT and gadolinium-diethylene triamine pentaacetic acid-enhanced liver MRI within 4 weeks. FDG-PET and MRI were evaluated blindly and then compared using the ratio of lesion to normal liver parenchyma PET-derived standardized uptake value (SUV). The influence of lesion size and response to chemotherapy were studied. RESULTS: Overall, 108 liver lesions were seen: 34 (31%) on both modalities (1-18 lesions/patient), four (4%) by PET/CT only, and 70 (65%) by MRI only. SUV correlated with MRI lesion size (r=0.81, P<0.0001). PET/CT detected 26 of 33 (79%) MRI lesions of more than or equal to 1.2 cm, whereas it detected only eight of 71 (11%) lesions of less than 1.2 cm (P<0.0001). MRI lesions without PET correspondence were small (0.6±0.2 vs. 2.1±1.1 cm, P<0.0001). During follow-up (six patients, 30 lesions), the ratio lesion-to-normal-liver SUV diminished in size-stable lesions (1.90±0.64-1.46±0.50, P<0.0001), whereas it increased in enlarging lesions (1.56±0.40-1.99±0.56, P=0.032). CONCLUSION: MRI outweighs PET/CT for detecting small liver metastases. However, PET/CT detected at least one liver metastasis per patient and changes in FDG uptake not related to size change, suggesting a role in assessing early therapy response.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Four different types of internal hernias (IH) are known to occur after laparoscopic Roux-en-Y gastric bypass (LRYGBP) performed for morbid obesity. We evaluate multidetector row helical computed tomography (MDCT) features for their differentiation. METHODS: From a prospectively collected database including 349 patients with LRYGBP, 34 acutely symptomatic patients (28 women, mean age 32.6), operated on for IH immediately after undergoing MDCT, were selected. Surgery confirmed 4 (11.6%) patients with transmesocolic, 10 (29.4%) with Petersen's, 15 (44.2%) with mesojejunal, and 5 (14.8%) with jejunojejunal IH. In consensus, 2 radiologists analyzed 13 MDCT features to distinguish the four types of IH. Statistical significance was calculated (p < 0.05, Fisher's exact test, chi-square test). RESULTS: MDCT features of small bowel obstruction (SBO) (n = 25, 73.5%), volvulus (n = 22, 64.7%), or a cluster of small bowel loops (SBL) (n = 27, 79.4%) were inconsistently present and overlapped between the four IH. The following features allowed for IH differentiation: left upper quadrant clustered small bowel loops (p < 0.0001) and a mesocolic hernial orifice (p = 0.0003) suggested transmesocolic IH. SBL abutting onto the left abdominal wall (p = 0.0021) and left abdominal shift of the superior mesenteric vessels (SMV) (p = 0.0045) suggested Petersen's hernia. The SMV predominantly shifted towards the right anterior abdominal wall in mesojejunal hernia (p = 0.0033). Location of the hernial orifice near the distal anastomosis (p = 0.0431) and jejunojejunal suture widening (p = 0.0005) indicated jejunojejunal hernia. CONCLUSIONS: None of the four IH seems associated with a higher risk of SBO. Certain MDCT features, such as the position of clustered SBL and hernial orifice, help distinguish between the four IH and may permit straightforward surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Les tumeurs de la paroi thoracique sont des pathologies graves dont le traitement principal consiste en une résection chirurgicale. L'enjeu majeur de cette intervention ontologique est de réséquer la totalité de la tumeur, ce qui nécessite une planification préopératoire minutieuse. Classiquement, l'identification et la localisation de la tumeur se fait à l'aide de la tomodensitométrie (computed tomography, CT) ou de l'imagerie par résonnance magnétique (1RM). Actuellement, l'imagerie nucléaire fonctionnelle par tomographie par émission de positons (positron emission tomography, PET) qui peut être couplée au CT (PET/CT) est de plus en plus appliquée aux patients présentant une tumeur maligne. Son efficacité a fréquemment été démontrée. Le but de la présente étude est d'évaluer la valeur du PET dans la planification de la résection des tumeurs de la paroi thoracique. Une analyse rétrospective de dix-huit patients opérés entre 2004 et 2006 a été réalisée; Dans ce groupe de patient, la taille de la tumeur mesurée sur la pièce opératoire réséquée a été comparée à la taille de la tumeur mesurée sur le CT et le PET. Les résultats démontrent que le CT surestimait de manière consistante la taille réelle de la tumeur par rapport au PET (+64% par rapport à +1%, P<0.001). De plus, le PET s'est avéré particulièrement performant pour prédire la taille des tumeurs de plus de 5.5 cm de diamètre par rapport au CT (valeur prédictive positive 80% par rapport à 44% et spécificité 93% par apport à 64%, respectivement). Cette étude démontre que le PET permettrait de mesurer la taille des tumeurs de la paroi thoracique de manière plus précise que le CT. Cette nouvelle modalité diagnostique s'avèrerait donc utile pour planifier les résections chirurgicales de telles tumeurs. A notre connaissance, aucune publication ne décrit la valeur du PET dans ce domaine. Les performances accrues du PET permettraient une meilleure délimitation des tumeurs ce qui améliorerait la précision de la résection chirurgicale. En conclusion, cette étude préliminaire rétrospective démontre la faisabilité du PET pour les tumeurs de la paroi thoracique. Ces résultats devraient être confirmés par une étude prospective incluant un plus grand nombre de patients avec la perspective de juger l'impact clinique réel du PET sur la prise en charge thérapeutique des patients.