979 resultados para Electric power company


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Some changes in the application of the numeric trapezoidal integration are analyzed for applications considering pi circuits. It is considered numeric and computational proceedings for improving the numeric results obtained with associations of pi circuits. In numeric integration solutions of the linear systems, it is common to represent these associations of pi circuits by only one matrix. This representation introduces undesirable numeric oscillations in simulations of the dynamics of wave propagation in electrical systems. The proposed changes improve the results of application of cascades of pi circuits associated to the trapezoidal integration, avoiding that the numerical oscillations, or Gibb's oscillations, have high values and are slowly damped. For the carried out simulations, different number of pi circuits and voltage sources are checked, confirming the reduction of the influence of the numeric oscillations on the obtained results. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEB

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cogeneration may be defined as the simultaneous production of electric power and useful heat from the burning of a single fuel. This technique of combined heat and power production has been applied in both the industrial and tertiary sectors. It has been mainly used because of its overall efficiency, and the guarantee of electricity with a low level of environmental impact. The compact cogeneration systems using internal combustion engine as prime movers are thoroughly applied because of the good relationship among cost and benefit obtained in such devices. The cogeneration system of this study consists of an internal combustion engine using natural gas or biogas as fuel, combined with two heat exchangers and an absorption chiller utilising water-ammonia as working mixture. This work presents an energetic and economic comparison between natural gas and biogas as fuel used for the system proposed. The results are useful to identify the feasible applications for this system, such as residential sector in isolated areas, hotels, universities etc. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The transmission expansion planning problem in modern power systems is a large-scale, mixed-integer, nonlinear and non-convex problem. this paper presents a new mathematical model and a constructive heuristic algorithm (CHA) for solving transmission expansion planning problem under new environment of electricity restructuring. CHA finds an acceptable solution in an iterative process, where in each step a circuit is chosen using a sensitivity index and added to the system. The proposed model consider multiple generation scenarios therefore the methodology finds high quality solution in which it allows the power system operate adequacy in an environment with multiple generators scenarios. Case studies and simulation results using test systems show possibility of using Constructive heuristic algorithm in an open access system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper considers the congestion effects on emission and consumers' allocated cost. In order to consider some environmental and operational effects of congestion, an environmental constrained active-reactive optimal power flow (AROPF) considering capability curve is presented. On outage conditions, the total cost of the system will increase. On the other hand in power systems, the operating cost and system emission have conflicted objectives, then it may be concluded that the outage in the system may lead to a total emission decrease. In this paper the famous Aumann-Shapley method is used as a pricing methodology. Two case studies such as 14-bus and US-bus IEEE test systems are conducted. Results demonstrate that, although the line outage in power systems leads to increase the total cost, the amount of emission depending on the place where the outage occurs can be more than, less than or equal to the normal conditions' emission. Also results show that although from power sellers' standpoint the well-known Aumann-Shapley method is a precise pricing method to cover the incurred cost with an acceptable error that can show the real effect of congestion on consumers' cost, from consumers' standpoint it is not a good method for cost allocation, because some consumers will face with an increase in cost and the others will face with a decrease on their cost.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Faced with an imminent restructuring of the electric power system, over the past few years many countries have invested in a new paradigm known as Smart Grid. This paradigm targets optimization and automation of electric power network, using advanced information and communication technologies. Among the main communication protocols for Smart Grids we have the DNP3 protocol, which provides secure data transmission with moderate rates. The IEEE 802.15.4 is another communication protocol also widely used in Smart Grid, especially in the so-called Home Area Network (HAN). Thus, many applications of Smart Grid depends on the interaction of these two protocols. This paper proposes modeling, in the traditional network simulator NS-2, the integration of DNP3 protocol and the IEEE 802.15.4 wireless standard for low cost simulations of Smart Grid applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The process of electric arc welding with shielding gas (GMAW) is being increasingly used in various industrial applications. This process occurs by which an electric arc is established between the work piece and a consumable in the form of wire, the arc melts the wire continuously as it is fed to the weld pool. The weld metal is protected from the atmosphere by flowing a gas (or gas mixture) inert or active. This paper presents a study of the welding process GMAW - MIG on aluminum tubes, alloy 6101 - T6, used in the manufacture of armored busbar, intended for driving electric power plants. 5(five) were welded specimens, changing certain welding parameters at each time was monitored welding joint as well as the interpass temperature. Tests were performed bending, tensile and macrographical analysis of body-of-evidence and through its results was possible to reach a better welding condition, which minimizes the appearance of pores, since the porosity has great influence on the mechanical strength and electrical conductivity of welded pipes

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electrical energy is present in the lives of all people and is extremely important that it be delivered to end users with plenty of quality, safety and low costs. The electric power substations are responsible for transmission and distribution of electricity generating sources to consumers, and with technological advances and the subsequent automation of same, the electricity began to be delivered with greater continuity and reliability. Protection systems in substations are largely responsible for making the electricity reaches the final consumer with quality, since their function is to prevent the spread of any type of failure occurred at any point of transmission to the load centers. These systems consist primarily by the current transformers and potential, by the protective relays and circuit breakers and switchgear. The processors send the necessary data to the relays and, if those detect any abnormality in the system, operate the opening command of the branch circuit breakers to isolate where the fault. Therefore, it is essential to better understand the operation of such equipment, as well as the overall system. This work aims to study the main substation equipment, current transformers and potential and, especially, protection relays, in order to obtain the advantages that automated systems can provide

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper are compared two methods of deploying electrical substations, conventional type, when installed at open areas (Air Insulated Switchgear - AIS), and compact gas-insulated (Gas Insulated Switchgear - GIS) when installed inside buildings. With the expansion of urban centers, areas available for deployment of conventional substations become increasingly difficult to find in these locations. Also due to speculation in urban areas, it becomes feasible to install Gas Insulated Switchgear. This paper presents and evaluates criteria with advantages and disadvantages for application of the two methodologies, aiming to assist in decisionmaking moment of choice in deployment of Electric Power Substations in two scenarios. It is expected that at the end of this work, the criteria evaluated assist in this decision making

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present work assessment materials can be used as fuel cells electrocatalysts. The alkaline fuel cell though was less studied, has some advantages compared to the acid configuration. The materials assesment were Au polycrystalline and intermetallics ordered phases of AuIn, AuSn and AuSb2. Your electrocatalytic properties were studied across cyclic voltametry and chronoamperometry techniques in Sodium Hydroxide 0,15M and Metanol 0,15M solution. The results obtained show a more efficiency to intermetallic AuIn as electrocatalyst for the oxidation reaction of methanol in alkaline medium, it showed high levels of current density and on set potential less positive compared to Au polycrystalline. The intermetallic AuSn showed activity just higher concentrations of methanol. Except AuSb2, who represented himself unstable in alkaline media, the intermetallics AuIn and AuSn present a promising future as anode materials for the oxidation in alkaline medium