998 resultados para EXCITONIC ABSORPTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The TL, optical absorption (OA) and EPR properties of natural Brazilian alexandrite and chrysoberyl have been investigated. The TL measurements for natural alexandrite show five peaks between 100 and 450°C, with their emission spectrum having 370 and/or 570 nm components. The intensity of the 320°C TL peak was found to be enhanced with pre-annealing treatment, more prominently above 600°C. The OA and EPR measurements showed that this kind of heat treatment induces the Fe2→ Fe3+ conversion in the natural sample. Chrysoberyl samples exhibited the TL peaks at the same temperatures as alexandrite samples, but the glow curves were more than 200 times less intense than alexandrite ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optical limiting behavior and nonlinear optical properties of antimony and lead oxyhalide glasses were discussed. The large nonlinear absorption coefficients which range from 11 to 20 cm/GW was determined using standard Z-scan technique. The photodarkening in the samples were observed which suggested that they can also be useful for inscribing Bragg gratings using green lasers of moderate power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work it was developed a procedure for the determination of vanadium in urine samples by electrothermal atomic absorption spectrometry using successive injections for preconcentration into a preheated graphite tube. Three 60 μL volumes were sequentially injected into the atomizer preheated to a temperature of 110°C. Drying and pyrolysis steps were carried out after each injection. A chemical modifier, barium difluoride (100 mg L-1), and a surfactant, Triton X-100 (0.3% v v-1), were added to the urine sample. When injecting into a hot graphite tube, the sample flow-rate was 0.5 μL s-1. The limits of detection and quantification were 0.54 and 1.82 without preconcentration, and 0.11 and 0.37 μg L-1 with preconcentration, respectively. The accuracy of the procedure was evaluated by an addition-recovery experiment employing urine samples. Recoveries varied from 96.0 to 103% for additions ranging from 0.8 to 3.5 μg L-1 V. The developed procedure allows the determination of vanadium in urine without any sample pretreatment and with minimal dilution of the sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work shows the potentiality of As as internal standard to compensate errors from sampling of sparkling drinking water samples in the determination of selenium by graphite furnace atomic absorption spectrometry. The mixture Pd(NO 3) 2/Mg(NO 3) 2 was used as chemical modifier. All samples and reference solutions were automatically spiked with 500 μg l -1 As and 0.2% (v/v) HNO 3 by the autosampler, eliminating the need for manual dilutions. For 10 μl dispensed sample into the graphite tube, a good correlation (r=0.9996) was obtained between the ratio of analyte absorbance by the internal standard absorbance and the analyte concentrations. The relative standard deviations (R.S.D.) of measurements varied from 0.05 to 2% and from 1.9 to 5% (n=12) with and without internal standardization, respectively. The limit of detection (LD) based on integrated absorbance was 3.0 μg l -1 Se. Recoveries in the 94-109% range for Se spiked samples were obtained. Internal standardization (IS) improved the repeatability of measurements and increased the lifetime of the graphite tube in ca. 15%. © 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polysaccharicles, as alginate and chitosan, have been used to obtain modified release dosage forms. Alginate, due to its property of building gels during the complex formation with calcium ions, allows the building of capsules containing a core constituted by calcium alginate. This work had for objective to determine the appropriate calcium concentration for the preparation of alginate-chitosan capsules, by means of calcium quantification using atomic absorption spectrophotometry. The methodology of calcium quantification was validated through analysis of the limit of detection, precision, accuracy and recovery of the method. The capsules, containing or not the drug, were prepared by the complex coacervation/ionotropic gelification method. Calcium was quantified after samples mineralization and dilution in lantanium solution. The results showed that the amount of calcium incorporated into the capsules depends on the amount of calcium added to the medium, and this ratio increases until the concentration of 1.5% of initial calcium chloride and above this concentration there is a decrease in the proportion of calcium bonded. It was observed that the proportion of calcium that links to the polymer is inversely proportional to the amount of calcium added. The calcium amount incorporated depends on the concentration of the polymeric dispersions used as well as on the ratio between the two polymers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to evaluate absorption and translocation of the herbicide 2,4-D in plants of Memora peregrina. The herbicide 2,4-D was used alone with the formulation DMA 806 BR and associated with the herbicide picloram in the commercial product Padron. Levels of radioactivity on the treated leaves were determined in sample obtained after washing them with methanol and chloroform at different times after the application of the radiolabelled formulation (1, 2, 4, 8, 24, and 48 h). Translocation was evaluated by cutting plants between stem and root. The parts obtained were: root, stem, leaf treated, leaves above the leaf treated, leaves below the leaf treated, and leaf opposite of the leaf treated. These parts were weighted, dried, ground, burnt, and radioactivity in the samples was determined. The results suggest that the translocation of the radioactive herbicide 2,4-D was insignificant in plants of M. peregrina in the two treatments evaluated. Absorption of 14C 2,4-D in the treatment with DMA 806 BR and the mixture of DMA 806 BR plus Padron had the same behavior. These observations explain the inefficient control obtained with this herbicide in plant species under study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nile tilapia Oreochromis niloticus fingerlings were fed with purified or practical diets, supplemented with 150 Ing Zn/kg, from different sources. Dry matter (DM), crude protein (CP), ether extract (EE), and gross energy (GE) apparent digestibility coefficients (ADC), as well as zinc, copper, calcium, and phosphorus apparent absorption coefficients (AAC) were determined by the addition of 0.1% chromic oxide to the diets. The supplemental zinc sources utilized were commercial grade zinc sulfate monohydrate (ZnSO 4), zinc oxide (ZnO) and a zinc amino acid complex (Zn-AA). Analytical grade zinc sulfate heptahydrate was also utilized as a standard reference zinc source. There was a significant difference between purified (74.9%) and practical (41.3%) zinc AAC for the ZnO supplemented diets (P < 0.05). The supplemental zinc sources presented similar AAC when purified diets were utilized. However, ZnSO 4 was the best supplemental zinc source when practical type diets were used. There were no significant differences between supplemental zinc AAC from ZnS0 4 (68.9%), and supplemental zinc AAC from Zn-AA (61.3%) in practical diets, but Zn-AA diet showed a statistically lower zinc AAC when compared with the standard zinc source diet (75.6%). The practical diet supplemented with ZnO had the worst supplemental zinc AAC (41.3%). Dietary copper (74.21%), calcium (70.9%), and phosphorus (71.9%) AAC of the practical diets supplemented with ZnO were statistically lower (P < 0.05) than the respective AAC of the practical ZnSO 4 supplemented diets (83.6%, 84.1%, 87.1%).The ADC of the practical ZnO supplemented diet for DM (76.3%), CP (88.6%), EE (82.4%), and GE (81.6%) were statiscally lower than the respective ADC of the ZnSO 4 practical diet (86.0, 92.7, 93.6, 89.6%, respectively) and those ADC of the Zn-AA practical diet (84.7, 92.7, 93.7, 88.2%, respectively) (P < 0.05). Hence, these results indicate that ZnSO 4 and Zn-AA have equivalent intestinal absorption as supplemental zinc sources for Nile tilapia juveniles and both are superior to ZnO. © Copyright by the World Aquaculture Society 2005.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Knowledge about nonlinear absorption spectra of materials used in photonic devices is of paramount importance in determining their optimum operation wavelengths. In this work, we have investigated the two-photon absorption (2PA) degenerate cross-section spectrum for perylene derivatives using the Z-scan technique with femtosecond laser pulses. All perylene derivatives studied present large 2PA cross-sections, only comparable to the best ones reported in the literature. The results achieved in the present investigation indicate perylene derivatives as promising materials for two-photon applications. ©2005 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combination of x-ray absorption spectroscopy (XAS) with UV-Vis and Raman spectroscopies or with Differential Scanning Calorimetry (DSC) has been recently carried out on the D44 beamline of DCI-LURE. The different set-ups used to perform such combinations are described and examples of combined investigations belonging to different field of materials science (coordination chemistry, sol-gel and catalysis) are presented. © Physica Scripta 2005.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different modifiers (IrCl3, W+IrCl3, Zr+IrCl 3) and coatings (Ir, W-Ir, Zr-Ir) were evaluated for the simultaneous determination of arsenic, bismuth, lead, antimony, and selenium in milk by graphite furnace atomic absorption spectrometry using the 'end-capped' transversely heated graphite atomizer (THGA). Integrated platform, pretreated with Zr-Ir as permanent modifier, was elected as the optimum surface modification resulting in up to 250 firings. Two additional recoatings were possible without significant changes in the analytical performance (750 firings). For 20 μL of matrix-matched standard solutions using diluted (1:10) milk samples, typical correlation coefficients between integrated absorbance and analyte concentration (5.00-20.0 μg/L) was always better than 0.999. The levels of the analytes found in commercial milk samples were lower than the limit of detection: 2.9 μg/L As, 2.9 μg/L Bi, 1.8 μg/L Pb, 1.9 μg/L Sb, and 2.5 μg/L Se. Recoveries were found within the following intervals: 88-114% for As, 89-118% for Bi, 89-113% for Pb, 91-115% for Sb, and 92-115% for Se. The relative standard deviations (n = 12) were ≤2% (As), ≤ 5% (Bi), ≤ 1.4% (Pb), ≤ 3% (Sb), and 5% (Se), and the respective calculated characteristic masses were 54 pg As, 55 pg Bi, 40 pg Pb, 56 pg Sb, and 51 pg Se.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nonlinear (NL) optical properties of antimony oxide based glasses (AG) were characterized for excitation wavelengths from 800 to 1600 m. The NL refractive indices, n2, and the two-photon absorption (TPA) coefficient, β, have been evaluated using the Z-scan technique. Values of n2≈ 10-15 - 10-14 cm2/W of electronic origin were measured and negligible TPA coefficients (β < 0.003 cm/GW) were determined. The response time of the nonlinearity is faster than 100 fs as determined using the Kerr shutter technique. The figure-of-merit usually considered for all-optical switching, T = 2βλ/n2 , indicates that AG are very good materials for ultrafast switches at telecom wavelengths. © 2007 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new approach based on a N-a cluster photoabsorption model is proposed for the understanding of the puzzling steady increase behavior of the 90Zr (e, α) yield measured at the National Bureau of Standards (NBS) within the Giant Dipole Resonance and quasideuteron energy range. The calculation takes into account the pre-equilibrium emissions of protons, neutrons and alpha particles in the framework of an extended version of the multicollisional intranuclear cascade model (MCMC). Another Monte Carlo based algorithm describes the statistical decay of the compound nucleus in terms of the competition between particle evaporation (p, n, d, α, 3He and t) and nuclear fission. The results reproduce quite successfully the 90Zr (e,α) yield, suggesting that emissions of a particles are essential for the interpretation of the exotic increase of the cross sections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work develops and optimizes a method to determine copper in samples of feces and fish feed by graphite furnace atomic absorption spectrometry (GFAAS) through the direct introduction of slurries of the samples into the spectrometer's graphite tube coated internally with metallic rhodium and tungsten carbide that acts as chemical modifiers. The limits of detection (LOD) and quantification (LOQ) calculated for 20 readings of the blank of the standard slurries (0.50% m/v of feces or feed devoid of copper) were 0.24 and 0.79 μg L -1 for the standard feces slurries and 0.26 and 0.87 μg L -1 for the standard feed slurries. The proposed method was applied in studies of absorption of copper in different fish feeds and their results proved compatible with that obtained from samples mineralized by acid digestion using microwave oven. © Springer Science+Business Media, LLC 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Propolis is a natural product collected by honeybees and has a large range of pharmacological activity, including antimicrobial, antitumoral, antioxidant and anti-inflammatory. Its use as a popular medicine is increasing all over the world, creating a need for quality control of the commercial products. In this study the levels of calcium and magnesium in commercial hydroalcoholic propolis extracts from varies states of Brazil were determined by atomic absorption flame spectrophotometry and different values were obtained for northern and southern states. This study can be extended to the analysis of metals that are harmful to health. The results showed that the calibration curves were linear over a wide concentration range (0.5-4.0 μg.mL -1 for calcium and 0.05-0.4 μg.mL -1 for magnesium) with good correlation coefficients (0.999 and 0.988, respectively). Good analytical recovery (94%) was obtained. The proposed method showed adequate precision and relative standard deviation lower than 2 %. The method is accurate and precise as well as having advantages such as simplicity and speed.