910 resultados para ENDODERMAL INITIAL
Resumo:
This study evaluated the loss of the torque applied after use of new screws and after successive tightening. Four infrastructures (IE), using UCLA castable abutment type, were cast in cobalt-chromium alloy and new abutment screws (G1) were used in a first moment. Subsequently, the same abutment screws were used a second time (G2) and more than two times (G3). The values of the torques applied and detorques were measured with a digital torque wrench to obtain the values of initial tightening loss (%). Data were analyzed by ANOVA and Tukey's test (?=0.05). Significant differences were observed between the G1 (50.71% ± 11.36) and G2 (24.01% ± 3.33) (p=0.000) and between G1 (50.71% ± 11.36) and G3 (25.60% ± 4.64) (p=0.000). There was no significant difference between G2 and G3 (p=0.774). Within the limitations of the study, it may be concluded that the percentage of the initial torque loss is lower when screws that already suffered the application of an initial torque were used, remaining stable after application of successive torques.
Resumo:
This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100%) given to abutment screws. Pearson's correlation (α=0.05) between the misfit values (29.08 ± 8.78 µm) and the percentage of detorque (50.71 ± 11.37%) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.
Resumo:
OBJECTIVES: To evaluate the color stability and hardness of two denture liners obtained by direct and indirect techniques, after thermal cycling and immersion in beverages that can cause staining of teeth. MATERIAL AND METHODS: Seventy disc-shaped specimens (18 x 3 mm) processed by direct (DT) and indirect techniques (IT) were made from Elite soft (n=35) and Kooliner (n=35) denture liners. For each material and technique, 10 specimens were subjected to thermal cycling (3,000 cycles) and 25 specimens were stored in water, coffee, tea, soda and red wine for 36 days. The values of color change, Shore A hardness (Elite soft) and Knoop hardness (Kooliner) were obtained. The data were subjected to ANOVA, Tukey's multiple-comparison test, and Kruskal-Wallis test (P<0.05). RESULTS: The thermal cycling promoted a decrease on hardness of Kooliner regardless of the technique used (Initial: 9.09± 1.61; Thermal cycling: 7.77± 1.47) and promoted an increase in the hardness in the DT for Elite Soft (Initial: 40.63± 1.07; Thermal cycling: 43.53± 1.03); hardness of Kooliner (DT: 8.76± 0.95; IT: 7.70± 1.62) and Elite Soft (DT: 42.75± 1.54; IT=39.30± 2.31) from the DT suffered an increase after the immersion in the beverages. The thermal cycling promoted color change only for Kooliner in the IT. Immersion in the beverages did not promote color change for Elite in both techniques. The control group of the DT of Kooliner showed a significant color change. Wine and coffee produced the greatest color change in the DT only for Elite Soft when compared to the other beverages. CONCLUSION: The three variation factors promoted alteration on hardness and color of the tested denture lining materials.
Resumo:
This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35% hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1% significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38±0.66ºC). The LED unit produced the lowest temperature increase (0.29±0.13ºC); but there was no significant difference between LED unit and LED-laser system (0.35±0.15ºC) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41±0.64ºC), and LED-laser system the lowest (0.33±0.12ºC); however, there was no difference between LED-laser system and LED unit (0.44±0.11ºC). LED and LED-laser system did not differ significantly from each other regardless the temperature rise occurred with or without bleaching agent application. It may be concluded that during light-activated tooth bleaching, with or without the bleaching agent, halogen light promoted higher pulp chamber temperature rise than LED unit and LED-laser system. The tested light-curing units provided increases in the pulp chamber temperature that were compatible with pulpal health.
Resumo:
OBJETIVO: determinar as medidas lineares dos estágios de desenvolvimento da dentição permanente humana, usando tomografia computadorizada de feixe cônico (TCFC). MÉTODOS: este estudo foi desenvolvido a partir de bancos de dados de clínicas radiológicas privadas, envolvendo 18 pacientes (13 do sexo masculino, 5 do sexo feminino, com idades variando entre 3 e 20 anos). As imagens das TCFC foram obtidas por meio do sistema i-CAT e medidas com uma função específica do programa desse mesmo sistema. Duzentos e trinta e oito dentes foram analisados, em diferentes estágios de desenvolvimento, nos planos coronal e sagital. O método foi baseado na delimitação e mensuração das distâncias entre pontos anatômicos correspondentes ao desenvolvimento das coroas e raízes dentárias. A partir dos valores obtidos, pôde-se desenvolver um modelo quantitativo para se avaliar os estágios inicial e final de desenvolvimento para todos os grupos dentários. RESULTADOS E CONCLUSÕES: as medidas obtidas dos diferentes grupos dentários estão de acordo com as estimativas das investigações publicadas previamente. As imagens por TCFC dos diferentes estágios de desenvolvimento podem contribuir no diagnóstico, planejamento e resultado dos tratamentos em diversas especialidades odontológicas. As dimensões das coroas e das raízes dentárias podem ter importantes aplicações clínicas e em pesquisas, constituindo uma técnica não invasiva que contribui com estudos in vivo. Entretanto, mais estudos são recomendados a fim de minimizar possíveis variáveis metodológicas.
Resumo:
OBJECTIVE: This study evaluated the influence of light sources and immersion media on the color stability of a nanofilled composite resin. MATERIAL AND METHODS: Conventional halogen, high-power-density halogen and high-power-density light-emitting diode (LED) units were used. There were 4 immersion media: coffee, tea, Coke® and artificial saliva. A total of 180 specimens (10 mm x 2 mm) were prepared, immersed in artificial saliva for 24 h at 37±1ºC, and had their initial color measured with a spectrophotometer according to the CIELab system. Then, the specimens were immersed in the 4 media during 60 days. Data from the color change and luminosity were collected and subjected to statistical analysis by the Kruskall-Wallis test (p<0.05). For immersion time, the data were subjected to two-way ANOVA test and Fisher's test (p<0.05). RESULTS: High-power-density LED (ΔE=1.91) promoted similar color stability of the composite resin to that of the tested halogen curing units (Jet Lite 4000 plus - ΔE=2.05; XL 3000 - ΔE=2.28). Coffee (ΔE=8.40; ΔL=-5.21) showed the highest influence on color stability of the studied composite resin. CONCLUSION: There was no significant difference in color stability regardless of the light sources, and coffee was the immersion medium that promoted the highest color changes on the tested composite resin.
Resumo:
This study investigated the influence of cervical preflaring with different rotary instruments on determination of the initial apical file (IAF) in mesiobuccal roots of mandibular molars. Fifty human mandibular molars whose mesial roots presented two clearly separated apical foramens (mesiobuccal and mesiolingual) were used. After standard access opening and removal of pulp tissue, the working length (WL) was determined at 1 mm short of the root apex. Five groups (n=10) were formed at random, according to the type of instrument used for cervical preflaring. In group 1, the size of the IAF was determined without preflaring of the cervical and middle root canal thirds. In groups 2 to 5, preflaring was performed with Gates-Glidden drills, ProTaper instruments, EndoFlare instruments and LA Axxes burs, respectively. Canals were sized manually with K-files, starting with size 08 K-files, inserted passively up to the WL. File sizes were increased until a binding sensation was felt at the WL and the size of the file was recorded. The instrument corresponding to the IAF was fixed into the canal at the WL with methylcyanoacrylate. The teeth were then sectioned transversally 1 mm short of the apex, with the IAF in position. Cross-sections of the WL region were examined under scanning electron microscopy and the discrepancies between canal diameter and the diameter of IAF were calculated using the tool "rule" (FEG) of the microscope's proprietary software. The measurements (µm) were analyzed statistically by Kruskal-Wallis and Dunn's tests at 5% significance level. There were statistically significant differences among the groups (p<0.05). The non-flared group had the greatest discrepancy (125.30 ± 51.54) and differed significantly from all flared groups (p<0.05). Cervical preflaring with LA Axxess burs produced the least discrepancies (55.10 ± 48.31), followed by EndoFlare instruments (68.20 ± 42.44), Gattes Glidden drills (68.90 ± 42.46) and ProTaper files (77.40 ± 73.19). However, no significant differences (p>0.05) were found among the rotary instruments. In conclusion, cervical preflaring improved IAF fitting to the canals at the WL in mesiobuccal roots of maxillary first molars. The rotary instruments evaluated in this study did not differ from each other regarding the discrepancies produced between the IAF size and canal diameter at the WL.
Resumo:
The purpose of this study was to evaluate the flexural strength of a direct composite, for indirect application, that received heat treatment, with or without investment. One indirect composite was used for comparison. For determination of the heat treatment temperature, thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) were performed, considering the initial weight loss temperature and glass transition temperature (Tg). Then, after photoactivation (600 mW/cm² - 40 s), the specimens (10 x 2 x 2 mm) were heat-treated following these conditions: 170ºC for 5, 10 or 15 min, embedded or not embedded in investment. Flexural strength was assessed as a means to evaluate the influence of different heat treatment periods and investment embedding on mechanical properties. The data were analyzed by ANOVA and Tukey's test (α = 0.05). TGA showed an initial weight loss temperature of 180ºC and DSC showed a Tg value of 157°C. Heat treatment was conducted in an oven (Flli Manfredi, Italy), after 37°C storage for 48 h. Flexural strength was evaluated after 120 h at 37°C storage. The results showed that different periods and investment embedding presented similar statistical values. Nevertheless, the direct composite resin with treatments presented higher values (178.7 MPa) compared to the indirect composite resin (146.0 MPa) and the same direct composite submitted to photoactivation only (151.7 MPa). Within the limitations of this study, it could be concluded that the heat treatment increased the flexural strength of the direct composite studied, leading to higher mechanical strength compared to the indirect composite.
Resumo:
The aim of this in vitro study was to evaluate four different approaches to the decision of changing or not defective amalgam restorations in first primary molar teeth concerning the loss of dental structure. Ditched amalgam restorations (n = 11) were submitted to four different treatments, as follows: Control group - polishing and finishing of the restorations were carried out; Amalgam group - the ditched amalgam restorations were replaced by new amalgam restorations; Composite resin group - the initial amalgam restorations were replaced by composite resin restorations; Flowable resin group - the ditching around the amalgam restorations was filled with flowable resin. Images of the sectioned teeth were made and the area of the cavities before and after the procedures was determined by image analysis software to assess structural loss. The data were submitted to ANOVA complemented by the Student Newman Keuls test (p < 0.05). The cavities in all the groups presented significantly greater areas after the procedures. However, the amalgam group showed more substantial dental loss. The other three groups presented no statistically significant difference in dental structure loss after the re-treatments. Thus, replacing ditched amalgam restorations by other similar restorations resulted in a significant dental structure loss while maintaining them or replacing them by resin restorations did not result in significant loss.
Resumo:
The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with 10 specimens each. In the wet groups, the inner threads of the implants were filled with artificial saliva. All abutments were fastened with a Torqtite screw under 32 Ncm. Ten detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean detorque values were calculated and compared by a Student's t test (?=0.05). The wet condition presented significantly higher mean detorque than the dry condition (31.5 ± 1.2 versus 27.5 ± 1.5 Ncm, respectively; p=0.0000024). In conclusion, there was always a loss in the initial torque values when the removal torque was measured under both conditions. The wet condition presented higher mean torque than the dry condition. Better preload values were established in the wet group, suggesting that the abutment screw must be lubricated in saliva to avoid further loosening.
Resumo:
The goals of this research were to estimate the phenotypic correlations among various meat quality traits from a male broiler line and to describe the relation among these variables. Phenotypical correlations were determined among quality traits, isolating the effects of slaughter date, the age of the mother and sex. The evaluated traits were pH measurements taken at time 0 and at 6 and 24 hours after slaughtering, color parameters, water loss due to exudation, thawing and cooking of the meat, and shear force. Important associations (P<0.01) were found to be significant and, in most cases, weak or moderate, varying from -0.35 to 0.28. The initial pH of the meat was not associated (P>0.05) to the other traits of the meat, whereas the pH at 24 hours after slaughter was able of directly interfering with the attributes of the meat, since this trait was inversely related with lightness and water losses, which indicates an effect of pH fall along 24h after slaughtering on protein denaturation. This study demonstrates that the variables of poultry meat quality are related and that there is a phenotypical association between lightness and cooking losses and the other attributes of the meat. The pH at 24 hours after slaughtering, lightness and cooking losses could be efficient meat quality indicators in this broiler line.
Resumo:
Um experimento foi conduzido com o objetivo de avaliar os efeitos da inclusão de ácido benzoico (Vevovitall®) na dieta sobre o desempenho e a morfologia intestinal do duodeno de leitões de 28 a 70 dias de idade. Foram utilizados 160 leitões Dalland × Penarlan desmamados aos 21 dias de idade, separados por sexo. O experimento foi dividido em fases pré-inicial 1 (28 a 35 dias de idade), pré-inicial 2 (36 a 46 dias de idade) e fase inicial (47 a 70 dias idade). Utilizou-se o delineamento experimental tipo blocos ao acaso com 5 tratamentos, cada um com 8 repetições de 4 animais, totalizando 40 unidades experimentais. Foram utilizados quatro níveis de ácido benzoico (0; 0,25; 0,50 e 0,75%) e um tratamento testemunha com ácido fumárico. Abateram-se, aos 70 dias de idade, dois animais por repetição para coleta de amostras do duodeno e estudo da morfologia intestinal e um animal por repetição para estudo de lesões gástricas. Foram avaliadas as características de desempenho (ganho de peso, consumo de ração e conversão alimentar) para cada fase e para o período total. Como características morfológicas, foram avaliadas a altura das vilosidades, a profundidade de criptas e a relação altura de vilosidades/profundidade de criptas. Avaliou-se ainda a incidência de diarreia. No período de 28 a 70 dias, o uso de ácido benzoico influencia o desempenho de suínos, que neste estudo foi melhor os níveis de 0,50 e 0,75%, e reduz a incidência de diarreia. Animais alimentados com dietas contendo ácido benzoico apresentam maior altura de vilosidade e profundidade de criptas.
Resumo:
Um experimento foi conduzido com o objetivo de avaliar os efeitos de duas fontes de vitamina D e três níveis de vitamina C sobre as características de desempenho, a qualidade interna e externa dos ovos, os níveis de cálcio total e iônico séricos e a resistência óssea de poedeiras. Foram utilizadas 288 galinhas da linhagem ISA Babcock B300® com 23 semanas de idade, durante um período experimental de 12 semanas. Utilizou-se o delineamento inteiramente ao acaso em arranjo fatorial 2 × 3, com os fatores: fontes de vitamina D (colecalciferol e 25-hidroxicolecalciferol - 25(OH)D3) e de vitamina C (0, 100 e 200 ppm), totalizando seis tratamentos com oito repetições de seis aves. O nível basal de colecalciferol foi de 2.756 UI/kg, correspondendo a 5,51 g do produto comercial Hy.D®/t de ração, como fonte de 25(OH)D3. Os fatores estudados não influenciaram o consumo de ração, a produção, o peso e a massa de ovos. Observou-se efeito da interação de fontes de vitamina sobre a conversão alimentar, que foi melhor quando utilizado metabólito 25(OH)D3 na ausência de vitamina C. Interações foram observadas para porcentagem de albúmen e porcentagem de gema, que aumentaram na presença de 200 ppm de vitamina C. O peso específico dos ovos, as concentrações de cálcio sérico, cinzas ósseas e a resistência à quebra não foram influenciadas pelas fontes de vitamina D e C. Houve interação para porcentagem e espessura de casca, cujos maiores valores foram obtidos com a suplementação de vitamina C na presença de 25(OH)D3. Em poedeiras na fase inicial de produção, a conversão alimentar é melhor com a utilização do 25(OH)D3 e a espessura e porcentagem de casca também melhoram com a utilização de 25(OH)D3 e a suplementação de vitamina C nas dietas (100 ou 200 ppm, respectivamente).
Resumo:
Este estudo teve como objetivo avaliar a influência da lavagem e da adição de eritorbato de sódio e tripolifosfato de sódio na estabilidade de Carne Mecanicamente Separada (CMS) de tilápia de Nilo (Oreochromis niloticus) durante 6 meses de armazenamento a -18 ºC. A CMS obtida por meio de máquina separadora de carne e ossos foi dividida em quatro tratamentos (CMS lavada com e sem aditivos, e CMS não lavada com e sem aditivos) e mantida sob congelamento a -18 ºC, por 180 dias. A estabilidade foi avaliada por meio de análises microbiológicas e determinações de nitrogênio não proteico (NNP), bases nitrogenadas voláteis (BNV), substâncias reativas ao ácido tiobarbitúrico (TBARS), pH e drip (perda de água no descongelamento). O processo de lavagem causou redução de aproximadamente 41, 44 e 66% nos teores de proteína bruta, lipídios e cinzas, respectivamente, reduzindo também os valores iniciais de NNP, BNV e TBARS. Durante o armazenamento, foram observados aumentos (p < 0,05) nos teores de NNP, BNV e pH em praticamente todos os tratamentos, exceto na CMS lavada com aditivos, que não apresentou aumentos significativos nos teores de NNP e pH. O uso de aditivos nas CMS diminuiu o drip ao longo do armazenamento, mas não alterou (p > 0,05) os teores de TBARS. Os parâmetros microbiológicos avaliados não ultrapassaram os limites permitidos pela legislação. As CMS permaneceram estáveis e em boas condições de utilização, independentemente da inclusão de aditivo, sendo viável sua estocagem a -18 ºC por 180 dias.
Resumo:
O objetivo deste trabalho foi determinar as características de qualidade da carne de suínos de diferentes linhagens genéticas, em diferentes pesos de abate. Neste estudo foram utilizados 88 suínos por linhagem, fêmeas e machos castrados, com idade e peso médio iniciais de 74 dias e 30kg, respectivamente, pertencentes a três linhagens genéticas distintas, designadas de AgroceresPic, Dalland e Seghers. A etapa experimental foi dividida em quatro fases (Crescimento I, Crescimento II, Terminação I e Terminação II). Ao final de cada etapa, foram abatidos 60 animais (10 por linhagem/sexo), para as análises de qualidade da carne. O pH e a temperatura foram determinados a 1 e 24 horas post mortem. Foram retiradas amostras para as determinações de cor, perda de água por exsudação (PAE), perda de água por cocção (PAC) e força de Cisalhamento. As amostras provenientes das carcaças dos animais da linhagem AgroceresPic e Dalland apresentaram valores médios de PAE superiores aos da linhagem Seghers. Os valores médios de PAC foram diferentes entre as diferentes fases. Na fase Crescimento II, as carnes provenientes das carcaças das fêmeas Dalland foram mais duras, ou seja, com maiores valores de força de cisalhamento, que as carnes dos machos. Entretanto, na linhagem Seghers, as carnes dos machos foram mais duras. Observou-se diferença de L* entre os sexos da linhagem AgroceresPic nas fases Terminação I e II e, na linhagem Dalland, na Terminação II. As linhagens Dalland e Seghers apresentaram carnes com resultados superiores de a*, parâmetro característico da cor vermelha (a*>0). Pode-se concluir, portanto, que as características de qualidade da carne de suínos (pH, perda de água por exsudação, cor e maciez) podem variar entre grupos genéticos, entre sexos e entre diferentes pesos ao abate.