931 resultados para Document segmentation
Resumo:
An expert multidisciplinary panel in the treatment of type B aortic dissection reviewed available literature to develop treatment algorithms using a consensus method. Data from 63 studies published from 2006 to 2012 were retrieved for a total of 1,548 patients treated medically, 1,706 patients who underwent open surgery, and 3,457 patients who underwent thoracic endovascular repair (TEVAR). For acute (first 2 weeks) type B aortic dissection, the pooled early mortality rate was 6.4% with medical treatment and increased to 10.2% with TEVAR and 17.5% with open surgery, mostly for complicated cases. Limited data for treatment of subacute (2 to 6 weeks after onset) type B aortic dissection showed an early mortality rate of 2.8% with TEVAR. In chronic (after 6 weeks) type B aortic dissection, 5-year survival of 60% to 80% was expected with medical therapy because complications were likely. If interventional treatment was applied, the pooled early mortality rate was 6.6% with TEVAR and 8.0% with open surgery. Medical treatment of uncomplicated acute, subacute, and chronic type B aortic dissection is managed with close image monitoring. Hemodynamic instability, organ malperfusion, increasing periaortic hematoma, and hemorrhagic pleural effusion on imaging identify patients with complicated acute type B aortic dissection requiring urgent aortic repair. Recurrence of symptoms, aortic aneurysmal dilation (>55 mm), or a yearly increase of >4 mm after the acute phase are predictors of adverse outcome and need for delayed aortic repair ("complicated chronic aortic dissections"). The expert panel is aware that this consensus document provides proposal for strategies based on nonrobust evidence for management of type B aortic dissection, and that literature results were largely heterogeneous and should be interpreted cautiously.
Resumo:
Speech is typically a multimodal phenomenon, yet few studies have focused on the exclusive contributions of visual cues to language acquisition. To address this gap, we investigated whether visual prosodic information can facilitate speech segmentation. Previous research has demonstrated that language learners can use lexical stress and pitch cues to segment speech and that learners can extract this information from talking faces. Thus, we created an artificial speech stream that contained minimal segmentation cues and paired it with two synchronous facial displays in which visual prosody was either informative or uninformative for identifying word boundaries. Across three familiarisation conditions (audio stream alone, facial streams alone, and paired audiovisual), learning occurred only when the facial displays were informative to word boundaries, suggesting that facial cues can help learners solve the early challenges of language acquisition.
Resumo:
The task considered in this paper is performance evaluation of region segmentation algorithms in the ground-truth-based paradigm. Given a machine segmentation and a ground-truth segmentation, performance measures are needed. We propose to consider the image segmentation problem as one of data clustering and, as a consequence, to use measures for comparing clusterings developed in statistics and machine learning. By doing so, we obtain a variety of performance measures which have not been used before in image processing. In particular, some of these measures have the highly desired property of being a metric. Experimental results are reported on both synthetic and real data to validate the measures and compare them with others.
Resumo:
PURPOSE: We evaluated the impact of premature extrauterine life on brain maturation. PATIENTS AND METHODS: Twelve neonates underwent MR imaging at 40 (39.64 +/- 0.98) weeks (full term). Fifteen premature infants underwent 2 MR imaging examinations, after birth (preterm at birth) and at 40 weeks (41.03 +/- 1.33) (preterm at term). A 3D MR imaging technique was used to measure brain volumes compared with intracranial volume: total brain volume, cortical gray matter, myelinated white matter, unmyelinated white matter, basal ganglia (BG), and CSF. RESULTS: The average absolute volume of intracranial volume (269.8 mL +/- 36.5), total brain volume (246.5 +/- 32.3), cortical gray matter (85.53 mL +/- 22.23), unmyelinated white matter (142.4 mL +/-14.98), and myelinated white matter (6.099 mL +/-1.82) for preterm at birth was significantly lower compared with that for the preterm at term: the average global volume of intracranial volume (431.7 +/- 69.98), total brain volume (391 +/- 66,1), cortical gray matter (179 mL +/- 41.54), unmyelinated white matter (185.3 mL +/- 30.8), and myelinated white matter (10.66 mL +/- 3.05). It was also lower compared with that of full-term infants: intracranial volume (427.4 mL +/- 53.84), total brain volume (394 +/- 49.22), cortical gray matter (181.4 +/- 29.27), unmyelinated white matter (183.4 +/- 27.37), and myelinated white matter (10.72 +/- 4.63). The relative volume of cortical gray matter (30.62 +/- 5.13) and of unmyelinated white matter (53.15 +/- 4.8) for preterm at birth was significantly different compared with the relative volume of cortical gray matter (41.05 +/- 5.44) and of unmyelinated white matter (43.22 +/- 5.11) for the preterm at term. Premature infants had similar brain tissue volumes at 40 weeks to full-term infants. CONCLUSION: MR segmentation techniques demonstrate that cortical neonatal maturation in moderately premature infants at term and term-born infants was similar.
Resumo:
Motivation: Array CGH technologies enable the simultaneous measurement of DNA copy number for thousands of sites on a genome. We developed the circular binary segmentation (CBS) algorithm to divide the genome into regions of equal copy number (Olshen {\it et~al}, 2004). The algorithm tests for change-points using a maximal $t$-statistic with a permutation reference distribution to obtain the corresponding $p$-value. The number of computations required for the maximal test statistic is $O(N^2),$ where $N$ is the number of markers. This makes the full permutation approach computationally prohibitive for the newer arrays that contain tens of thousands markers and highlights the need for a faster. algorithm. Results: We present a hybrid approach to obtain the $p$-value of the test statistic in linear time. We also introduce a rule for stopping early when there is strong evidence for the presence of a change. We show through simulations that the hybrid approach provides a substantial gain in speed with only a negligible loss in accuracy and that the stopping rule further increases speed. We also present the analysis of array CGH data from a breast cancer cell line to show the impact of the new approaches on the analysis of real data. Availability: An R (R Development Core Team, 2006) version of the CBS algorithm has been implemented in the ``DNAcopy'' package of the Bioconductor project (Gentleman {\it et~al}, 2004). The proposed hybrid method for the $p$-value is available in version 1.2.1 or higher and the stopping rule for declaring a change early is available in version 1.5.1 or higher.
Resumo:
OBJECTIVES: To determine the accuracy of automated vessel-segmentation software for vessel-diameter measurements based on three-dimensional contrast-enhanced magnetic resonance angiography (3D-MRA). METHOD: In 10 patients with high-grade carotid stenosis, automated measurements of both carotid arteries were obtained with 3D-MRA by two independent investigators and compared with manual measurements obtained by digital subtraction angiography (DSA) and 2D maximum-intensity projection (2D-MIP) based on MRA and duplex ultrasonography (US). In 42 patients undergoing carotid endarterectomy (CEA), intraoperative measurements (IOP) were compared with postoperative 3D-MRA and US. RESULTS: Mean interoperator variability was 8% for measurements by DSA and 11% by 2D-MIP, but there was no interoperator variability with the automated 3D-MRA analysis. Good correlations were found between DSA (standard of reference), manual 2D-MIP (rP=0.6) and automated 3D-MRA (rP=0.8). Excellent correlations were found between IOP, 3D-MRA (rP=0.93) and US (rP=0.83). CONCLUSION: Automated 3D-MRA-based vessel segmentation and quantification result in accurate measurements of extracerebral-vessel dimensions.
Resumo:
OBJECTIVE: To develop a novel application of a tool for semi-automatic volume segmentation and adapt it for analysis of fetal cardiac cavities and vessels from heart volume datasets. METHODS: We studied retrospectively virtual cardiac volume cycles obtained with spatiotemporal image correlation (STIC) from six fetuses with postnatally confirmed diagnoses: four with normal hearts between 19 and 29 completed gestational weeks, one with d-transposition of the great arteries and one with hypoplastic left heart syndrome. The volumes were analyzed offline using a commercially available segmentation algorithm designed for ovarian folliculometry. Using this software, individual 'cavities' in a static volume are selected and assigned individual colors in cross-sections and in 3D-rendered views, and their dimensions (diameters and volumes) can be calculated. RESULTS: Individual segments of fetal cardiac cavities could be separated, adjacent segments merged and the resulting electronic casts studied in their spatial context. Volume measurements could also be performed. Exemplary images and interactive videoclips showing the segmented digital casts were generated. CONCLUSION: The approach presented here is an important step towards an automated fetal volume echocardiogram. It has the potential both to help in obtaining a correct structural diagnosis, and to generate exemplary visual displays of cardiac anatomy in normal and structurally abnormal cases for consultation and teaching.