958 resultados para Discrete heat source
Resumo:
This paper proposes a hybrid solar cooking system where the solar energy is brought to the kitchen. The energy source is a combination of the solar thermal energy and the Liquefied Petroleum Gas (LPG) that is in common use in kitchens. The solar thermal energy is transferred to the kitchen by means of a circulating fluid. The transfer of solar heat is a twofold process wherein the energy from the collector is transferred first to an intermediate energy storage buffer and the energy is subsequently transferred from the buffer to the cooking load. There are three parameters that are controlled in order to maximize the energy transfer from the collector to the load viz, the fluid flow rate from collector to buffer, fluid flow rate from buffer to load and the diameter of the pipes. This is a complex multi energy domain system comprising energy flow across several domains such as thermal, electrical and hydraulic. The entire system is modeled using the bond graph approach with seamless integration of the power flow in these domains. A method to estimate different parameters of the practical cooking system is also explained. Design and life cycle costing of the system is also discussed. The modeled system is simulated and the results are validated experimentally. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Context. Polar corona is often explored to find the energy source for the acceleration of the fast solar wind. Earlier observations show omni-presence of quasi-periodic disturbances, traveling outward, which is believed to be caused by the ubiquitous presence of outward propagating waves. These waves, mostly of compressional type, might provide the additional momentum and heat required for the fast solar wind acceleration. It has been conjectured that these disturbances are not due to waves but high speed plasma outflows, which are difficult to distinguish using the current available techniques. Aims. With the unprecedented high spatial and temporal resolution of AIA/SDO, we search for these quasi-periodic disturbances in both plume and interplume regions of the polar corona. We investigate their nature of propagation and search for a plausible interpretation. We also aim to study their multi-thermal nature by using three different coronal passbands of AIA. Methods. We chose several clean plume and interplume structures and studied the time evolution of specific channels by making artificial slits along them. Taking the average across the slits, space-time maps are constructed and then filtration techniques are applied to amplify the low-amplitude oscillations. To suppress the effect of fainter jets, we chose wider slits than usual. Results. In almost all the locations chosen, in both plume and interplume regions we find the presence of propagating quasi-periodic disturbances, of periodicities ranging from 10-30 min. These are clearly seen in two channels and in a few cases out to very large distances (approximate to 250 `') off-limb, almost to the edge of the AIA field of view. The propagation speeds are in the range of 100-170 km s(-1). The average speeds are different for different passbands and higher in interplume regions. Conclusions. Propagating disturbances are observed, even after removing the effects of jets and are insensitive to changes in slit width. This indicates that a coherent mechanism is involved. In addition, the observed propagation speed varies between the different passpands, implying that these quasi-periodic intensity disturbances are possibly due to magneto-acoustic waves. The propagation speeds in interplume region are higher than in the plume region.
Resumo:
This paper considers the design and analysis of a filter at the receiver of a source coding system to mitigate the excess Mean-Squared Error (MSE) distortion caused due to channel errors. It is assumed that the source encoder is channel-agnostic, i.e., that a Vector Quantization (VQ) based compression designed for a noiseless channel is employed. The index output by the source encoder is sent over a noisy memoryless discrete symmetric channel, and the possibly incorrect received index is decoded by the corresponding VQ decoder. The output of the VQ decoder is processed by a receive filter to obtain an estimate of the source instantiation. In the sequel, the optimum linear receive filter structure to minimize the overall MSE is derived, and shown to have a minimum-mean squared error receiver type structure. Further, expressions are derived for the resulting high-rate MSE performance. The performance is compared with the MSE obtained using conventional VQ as well as the channel optimized VQ. The accuracy of the expressions is demonstrated through Monte Carlo simulations.
Resumo:
A swarm is a temporary structure formed when several thousand honey bees leave their hive and settle on some object such as the branch of a tree. They remain in this position until a suitable site for a new home is located by the scout bees. A continuum model based on heat conduction and heat generation is used to predict temperature profiles in swarms. Since internal convection is neglected, the model is applicable only at low values of the ambient temperature T-a. Guided by the experimental observations of Heinrich (1981a-c, J. Exp. Biol. 91, 25-55; Science 212, 565-566; Sci. Am. 244, 147-160), the analysis is carried out mainly for non-spherical swarms. The effective thermal conductivity is estimated using the data of Heinrich (1981a, J. Exp. Biol. 91, 25-55) for dead bees. For T-a = 5 and 9 degrees C, results based on a modified version of the heat generation function due to Southwick (1991, The Behaviour and Physiology of Bees, PP 28-47. C.A.B. International, London) are in reasonable agreement with measurements. Results obtained with the heat generation function of Myerscough (1993, J. Theor. Biol. 162, 381-393) are qualitatively similar to those obtained with Southwick's function, but the error is more in the former case. The results suggest that the bees near the periphery generate more heat than those near the core, in accord with the conjecture of Heinrich (1981c, Sci. Am. 244, 147-160). On the other hand, for T-a = 5 degrees C, the heat generation function of Omholt and Lonvik (1986, J. Theor. Biol. 120, 447-456) leads to a trivial steady state where the entire swarm is at the ambient temperature. Therefore an acceptable heat generation function must result in a steady state which is both non-trivial and stable with respect to small perturbations. Omholt and Lonvik's function satisfies the first requirement, but not the second. For T-a = 15 degrees C, there is a considerable difference between predicted and measured values, probably due to the neglect of internal convection in the model.
Resumo:
Optimizing a shell and tube heat exchanger for a given duty is an important and relatively difficult task. There is a need for a simple, general and reliable method for realizing this task. The authors present here one such method for optimizing single phase shell-and-tube heat exchangers with given geometric and thermohydraulic constraints. They discuss the problem in detail. Then they introduce a basic algorithm for optimizing the exchanger. This algorithm is based on data from an earlier study of a large collection of feasible designs generated for different process specifications. The algorithm ensures a near-optimal design satisfying the given heat duty and geometric constraints. The authors also provide several sub-algorithms to satisfy imposed velocity limitations. They illustrate how useful these sub-algorithms are with several examples where the exchanger weight is minimized.
Resumo:
Interest in the applicability of fluctuation theorems to the thermodynamics of single molecules in external potentials has recently led to calculations of the work and total entropy distributions of Brownian oscillators in static and time-dependent electromagnetic fields. These calculations, which are based on solutions to a Smoluchowski equation, are not easily extended to a consideration of the other thermodynamic quantity of interest in such systems-the heat exchanges of the particle alone-because of the nonlinear dependence of the heat on a particle's stochastic trajectory. In this paper, we show that a path integral approach provides an exact expression for the distribution of the heat fluctuations of a charged Brownian oscillator in a static magnetic field. This approach is an extension of a similar path integral approach applied earlier by our group to the calculation of the heat distribution function of a trapped Brownian particle, which was found, in the limit of long times, to be consistent with experimental data on the thermal interactions of single micron-sized colloids in a viscous solvent.
Resumo:
The present work is a numerical study of heat transfer characteristics from the bottom tip of a cylinder spinning about a vertical axis in an infinitely saturated porous medium. The problem is axisymmetric. The non-dimensionalized governing equations are solved using the SIMPLER algorithm on a staggered grid. The influence of rotational Reynolds numbers and Darcy numbers on the heat transfer for a Grashof number of 104 and Prandtl number of 7.0 is studied. It is found that for very high Darcy numbers, over a wide range of rotational Reynolds numbers, the heat transfer takes place mainly due to conduction. The convective heat transfer takes place for lower Darcy numbers and for higher rotational Reynolds numbers. Moreover, there is a rapid increase in the overall Nusselt number below a certain Darcy number with increase in the rotational Reynolds numbers. The effect of the Darcy number and the rotational Reynolds number on the heat transfer and fluid flow in the porous medium is depicted in the form of streamline and isotherm plots. The variation of the overall Nusselt number with respect to the Darcy number for various rotational Reynolds numbers is plotted. The variation of the local Nusselt number with respect to the radial coordinate at the heated tip of the vertical cylinder is plotted for various Darcy and rotational Reynolds numbers.
Resumo:
Natural convection from an isothermal vertical surface to a thermally stratified fluid is studied numerically. A wide range of stratification levels is considered. It is shown that at high levels of ambient thermal stratification, a portion at the top of the plate absorbs heat, while a horizontal plume forms around a location where the plate temperature equals the ambient temperature. The plume is shown to be inherently unsteady, and its transient nature is investigated in detail. The effect of the temperature defect in striating the plume is discussed. Average Nusselt number data are presented for Pr = 6.0 and 0.7.
Resumo:
The present paper aims at studying the performance characteristics of a subspace based algorithm for source localization in shallow water such as coastal water. Specifically, we study the performance of Multi Image Subspace Algorithm (MISA). Through first-order perturbation analysis and computer simulation it is shown that MISA is unbiased and statistically efficient. Further, we bring out the role of multipaths (or images) in reducing the error in the localization. It is shown that the presence of multipaths is found to improve the range and depth estimates. This may be attributed to the increased curvature of the wavefront caused by interference from many coherent multipaths.
Resumo:
In an earlier work, we had proposed a two-band, non-grey radiative transfer model for heat transfer in forehearths with simultaneous optically thick and thin approximations for molten glass interiors and at boundaries. Here using the same model, the radiative interaction of the top-crown and bottom-refractory walls with interior layers of shallow molten glass is studied by varying the wall emissivities. The forehearth exit temperature profiles for higher wall emissivities (0.9) show better conditioning of the glass for white flint glasses (optically thin).
Resumo:
This paper presents the results of a thermodynamic cycle analysis of single stage resorption heat pump (RHP) and resorption heat transformer (RHT) cycles with the new working pairs R22-NMP and R22-DMA. The coefficients of performance (COP) are correlated with the low grade source temperature, temperature at which useful heat is obtained and ambient temperature. The COPs are in the range 1.20–1.60 for the RHP mode and 0.25–0.45 for the RHT mode. Absorber temperatures (useful temperatures) as high as 50°C in the RHP mode and 87°C in the RHT mode have been obtained. It is observed that absorption-resorption systems are inflexible in their range of operating temperature and necessitate a higher pump work as compared with simple single-stage absorption heating systems. However, single stage RHTs show higher temperature boosts than simple absorption heat transformers.
Resumo:
The source localization in shallow water is beset with problems arising from the presence of a large number of correlated multipaths. Nevertheless, given a complete knowledge of the water channel it is definitely possible to localize a source. A complete knowledge of the channel, however, is rarely available under most practical conditions. A new approach is proposed wherein the bottom reflection coefficients are not required; hence the bottom conditions need not be known. Further, because of the use of signal subspace for localization, the proposed approach is robust against the background noise (-20 dB) and channel depth uncertainty (10 lambda). All these nice features of the proposed approach are possible only when the array size is large (>40 sensors). (C) 1995 Acoustical Society of America.
Resumo:
Bulk glasses of Ge(20)Se(80-x)ln(x) (O less than or equal to x less than or equal to 18) have been used for measurements of heat capacity at constant pressure (C-p) using a differential scanning calorimeter. These measurements reveal the chemical threshold in these glasses as a function of composition. The results are discussed in the light of microscopic phase separation in these glasses.
Resumo:
Tower data collected during the Monsoon-Trough Boundary Layer Experiment (MONTBLEX-90) have been analysed to understand the observed structure of the surface layer over an arid region (Jodhpur) and a moist region (Kharagpur) during active and weak phases of the 1990 southwest monsoon. Turbulent heat and momentum fluxes are estimated by the eddy correlation method using sonic data. The turbulent momentum flux at both Jodhpur and Kharagpur was larger when the winds were stronger, reaching a maximum of the order of 0.5 N m(-2) on 5 and 6 August when a low pressure system was located over the region. The heat flux at Jodhpur is high during weak monsoon days, the maximum being 450 W m(-2), whereas during active days the flux never exceeds 200 W m(-2). At Kharagpur, the flux does not vary significantly between active and weak monsoon days, the maximum in either phase being 160 W m(-2) At Jodhpur, there is significant contrast in the near-surface air temperature, being higher during weak monsoon days as compared to active days. Cloud cover did not vary significantly in both the regions. The turbulent heat flux variation at both the sites appears to be correlated mainly with soil mixture, and less sensitive to cloud cover.