906 resultados para Device architectures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the linear and nonlinear optical transfer characteristics of a multi-resonance device consisting of two optical ring resonators coupled one to the other and to an optical waveguide. The propagation effects displayed by the device are compared with those of a sequence of fundamental ring resonators coupled to a waveguide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present paper the results from designing of device, which is a part of the automated information system for counting, reporting and documenting the quantity of produced bottles in a factory for glass processing are presented. The block diagram of the device is given. The introduced system can be applied in other discrete productions for counting of the quantity of bottled production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problems of the cognitive development of subject “perception” are discussed in the thesis: from the object being studied and means of action till the single system “subject – modus operandi of subject – object”. Problems of increasing adequacy of models of “live” nature are analyzed. The concept of developing decisionmaking support systems as expert systems to decision-making support systems as personal device of a decisionmaker is discussed. The experience of the development of qualitative prediction on the basis of polyvalent dependences, represented by a decision tree, which realizes the concept of “plural subjective determinism”, is analyzed. The examples of applied systems prediction of ecological-economic and social processes are given. The ways of their development are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We introduce a robot-safety device system attended by two different repairmen. The twin system is characterized by the natural feature of cold standby and by an admissible “risky” state. In order to analyse the random behaviour of the entire system (robot, safety device, repair facility) we employ a stochastic process endowed with probability measures satisfying general Hokstad-type differential equations. The solution procedure is based on the theory of sectionally holomorphic functions, characterized by a Cauchy-type integral defined as a Cauchy principal value in double sense. An application of the Sokhotski-Plemelj formulae determines the long-run availability of the robot-safety device. Finally, we consider the particular but important case of deterministic repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a bi-metal coated (platinum and gold or silver), localized surface plasmon resonance fiber sensor with an index sensitivity exceeding 11,900 nm/RIU, yielding an index resolution of 2 × 10-5 in the aqueous index regime. This is one of the highest index sensitivities achieved with an optical fiber sensor. The coatings consist of arrays of bi-metal nano-wires (typically 36 nm in radius and 20 μm in length), supported by a silicon dioxide thin film on a thin substrate of germanium, the nano-wires being perpendicular to the longitudinal axis of the D-shaped fiber.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the area of Software Engineering, traceability is defined as the capability to track requirements, their evolution and transformation in different components related to engineering process, as well as the management of the relationships between those components. However the current state of the art in traceability does not keep in mind many of the elements that compose a product, specially those created before requirements arise, nor the appropriated use of traceability to manage the knowledge underlying in order to be handled by other organizational or engineering processes. In this work we describe the architecture of a reference model that establishes a set of definitions, processes and models which allow a proper management of traceability and further uses of it, in a wider context than the one related to software development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the principle of quasi-continuous filtering in a non-linear fibre, we propose an optical device for the simultaneous regeneration of sevaral channels at 40 Gbit/s. Simulations predict an improvement of the signal quality for four channels by more than 6.8 dB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Long term recording of biomedical signals such as ECG, EMG, respiration and other information (e.g. body motion) can improve diagnosis and potentially monitor the evolution of many widespread diseases. However, long term monitoring requires specific solutions, portable and wearable equipment that should be particularly comfortable for patients. The key-issues of portable biomedical instrumentation are: power consumption, long-term sensor stability, comfortable wearing and wireless connectivity. In this scenario, it would be valuable to realize prototypes using available technologies to assess long-term personal monitoring and foster new ways to provide healthcare services. The aim of this work is to discuss the advantages and the drawbacks in long term monitoring of biopotentials and body movements using textile electrodes embedded in clothes. The textile electrodes were embedded into garments; tiny shirt and short were used to acquire electrocardiographic and electromyographic signals. The garment was equipped with low power electronics for signal acquisition and data wireless transmission via Bluetooth. A small, battery powered, biopotential amplifier and three-axes acceleration body monitor was realized. Patient monitor incorporates a microcontroller, analog-to-digital signal conversion at programmable sampling frequencies. The system was able to acquire and to transmit real-time signals, within 10 m range, to any Bluetooth device (including PDA or cellular phone). The electronics were embedded in the shirt resulting comfortable to wear for patients. Small size MEMS 3-axes accelerometers were also integrated. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fullerene end-capped polymer-compatibilizer based on poly(3-hexylthiophene) (P3HT) was synthesized and demonstrated to have a remarkable effect on both the stability and efficiency of devices made from exemplar P3HT and [6,6]-phenyl C61-butyric acid methyl ester (PCBM). P3HT with ethynyl chain-ends and α-azido-ω-bromo-PS were prepared via Grignard metathesis (GRIM) and atom transfer radical polymerisation, respectively. “Click” chemistry resulted in the preparation of poly(3-hexylthiophene)-block-ω-bromo-polystyrene (P3HT-b-PS-Br), and subsequent atom transfer radical addition chemistry with fullerene (C60) yielded the donor–acceptor block copolymer P3HT-b-PS-C60. Both P3HT-b-PS-Br and P3HT-b-PS-C60 were considered as compatibilizers with P3HT/PCBM blends, with the study detailing effects on active-layer morphology, device efficiency and stability. When used at low concentrations, both P3HT-b-PS-Br (1%) and P3HT-b-PS-C60 (0.5%) resulted in considerable 28% and 35% increases in efficiencies with respect to devices made from P3HT/PCBM alone. Furthermore, P3HT-b-PS-C60 (0.5%) resulted in an important improvement in device stability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A successful and useful treatment for end-stage heart failure is Left ventricular assist device (LVAD). An important part - a hydrodynamically suspended impeller exposed to corrosive conditions, required to sealed hermetically into micro packages. Laser beam welded (LBW) Ti6Al4V alloy has been adopted in anti-corrosion micro packages for the impeller of a (LVAD). Thin and narrow welds were required for such medical equipment. Pulsed Nd:YAG welding was successfully adopted as sealing method for the impeller. ©2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We explored the potential of a carbon nanotube (CNT) coating working in conjunction with a recently developed localized surface plasmon (LSP) device (based upon a nanostructured thin film consisting of of nano-wires of platinum) with ultra-high sensitivity to changes in the surrounding index. The uncoated LSP sensor’s transmission resonances exhibited a refractive index sensitivity of Δλ/Δn ~ -6200nm/RIU and ΔΙ/Δn ~5900dB/RIU, which is the highest reported spectral sensitivity of a fiber optic sensor to bulk index changes within the gas regime. The complete device provides the first demonstration of the chemically specific gas sensing capabilities of CNTs utilizing their optical characteristics. This is proven by investigating the spectral response of the sensor before and after the adhesion of CNTs to alkane gases along with carbon dioxide. The device shows a distinctive spectral response in the presence of gaseous CO2 over and above what is expected from general changes in the bulk refractive index. This fiber device yielded a limit of detection of 150ppm for CO2 at a pressure of one atmosphere. Additionally the adhered CNTs actually reduce sensitivity of the device to changes in bulk refractive index of the surrounding medium. The polarization properties of the LSP sensor resonances are also investigated and it is shown that there is a reduction in the overall azimuthal polarization after the CNTs are applied. These optical devices offer a way of exploiting optically the chemical selectivity of carbon nanotubes, thus providing the potential for real-world applications in gas sensing in many inflammable and explosive environments. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interorganizational team research is a growing body of literature and research has started toexamine team related factors such as interorganizational trust (i.e. Stock, 2006) in theinterorganizational setting. This research applies insights from the intraorganizational teamfield into the interorganizational team setting in order to determine the team related factorspertaining to effective collaboration in medical device innovation projects.Interorganizational collaboration has been a persistent feature within the interorganizationalrelations literature, due to the added benefits that can come with working collaborativelytowards a common goal (Berg-Weger & Schnieder, 1998). While much research has exploredthe structures and performance outcomes of engaging in this cross-boundary working, theliterature is sparse with respect to interpersonal relationships, practices and processes leadingto effective collaboration (Bergenholtz & Waldstrom, 2011; Majchrzak, Jarvenpaa & Bargherz,2015). An interpretivist perspective has informed an exploratory mixed methods approach to datacollection, with contextual insights informing each phase of data collection. Three exploratoryphases of data collection have provided (1) qualitative ethnography data, (1i) qualitativeinterview data and (2) quantitative survey data. The NHS has recently set out agendas to increase innovative procurement (Department ofHealth, 2008), work more closely with industry and SMEs (Innovation and Procurement Plan:Department of Health, 2009) and to increase innovative practice (IHW: NHS, 2011). SMEsdeveloping novel medical devices require input from the NHS to ensure that their devices areclinically applicable and therefore will be adopted by the NHS. These contextual insightsprovide the backdrop for Studies 1i and 2. The findings suggest that the intraorganizational team literature can be extended into theinterorganizational collaboration literature, whilst also explaining the factors relating toeffectiveness and success of interorganizational team innovation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A szerzők tanulmányukban az információbiztonság egy merőben új, minőségi változást hozó találmányával, a kvantumkulcscserével (QKD-vel – quantum key distribution) foglalkoznak. Céljuk az, hogy az újdonságra mint informatikai biztonsági termékre tekintsenek, és megvizsgálják a bevezetéséről szóló vállalati döntés során felmerülő érveket, ellenérveket. Munkájuk egyaránt műszaki és üzleti szemléletű. Előbb elkülönítik a kvantumkulcscsere hagyományos eljárásokkal szembeni használatának motiváló tényezőit, és megállapítják, milyen körülmények között szükséges a napi működésben alkalmazni. Ezt követően a forgalomban is kapható QKD-termékek tulajdonságait és gyártóit szemügyre véve megfogalmazzák a termék széles körű elterjedésének korlátait. Végül a kvantumkulcscsere-termék bevezetéséről szóló vállalati döntéshozás különböző aspektusait tekintik át. Információbiztonsági és üzleti szempontból összehasonlítják az új, valamint a hagyományosan használt kulcscsereeszközöket. Javaslatot tesznek a védendő információ értékének becslésére, amely a használatbavétel költség-haszon elemzését támaszthatja alá. Ebből levezetve megállapítják, hogy mely szervezetek alkotják a QKD lehetséges célcsoportját. Utolsó lépésként pedig arra keresik a választ, melyik időpont lehet ideális a termék bevezetésére. _____ This study aims to illuminate Quantum Key Distribution (QKD), a new invention that has the potential to bring sweeping changes to information security. The authors’ goal is to present QKD as a product in the field of IT security, and to examine several pro and con arguments regarding the installation of this product. Their work demonstrates both the technical and the business perspectives of applying QKD. First they identify motivational factors of using Quantum Key Distribution over traditional methods. Then the authors assess under which circumstances QKD could be necessary to be used in daily business. Furthermore, to evaluate the limitations of its broad spread, they introduce the vendors and explore the properties of their commercially available QKD products. Bearing all this in mind, they come out with numerous factors that can influence corporate decision making regarding the installation of QKD. The authors compare the traditional and the new tools of key distribution from an IT security and business perspective. They also take efforts to estimate the value of the pieces of information to be protected. This could be useful for a subsequent cost–benefit analysis. Their findings try to provide support for determining the target audience of QKD in the IT security market. Finally the authors attempt to find an ideal moment for an organization to invest in Quantum Key Distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Software architecture is the abstract design of a software system. It plays a key role as a bridge between requirements and implementation, and is a blueprint for development. The architecture represents a set of early design decisions that are crucial to a system. Mistakes in those decisions are very costly if they remain undetected until the system is implemented and deployed. This is where formal specification and analysis fits in. Formal specification makes sure that an architecture design is represented in a rigorous and unambiguous way. Furthermore, a formally specified model allows the use of different analysis techniques for verifying the correctness of those crucial design decisions. ^ This dissertation presented a framework, called SAM, for formal specification and analysis of software architectures. In terms of specification, formalisms and mechanisms were identified and chosen to specify software architecture based on different analysis needs. Formalisms for specifying properties were also explored, especially in the case of non-functional properties. In terms of analysis, the dissertation explored both the verification of functional properties and the evaluation of non-functional properties of software architecture. For the verification of functional property, methodologies were presented on how to apply existing model checking techniques on a SAM model. For the evaluation of non-functional properties, the dissertation first showed how to incorporate stochastic information into a SAM model, and then explained how to translate the model to existing tools and conducts the analysis using those tools. ^ To alleviate the analysis work, we also provided a tool to automatically translate a SAM model for model checking. All the techniques and methods described in the dissertation were illustrated by examples or case studies, which also served a purpose of advocating the use of formal methods in practice. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorescence-enhanced optical imaging is an emerging non-invasive and non-ionizing modality towards breast cancer diagnosis. Various optical imaging systems are currently available, although most of them are limited by bulky instrumentation, or their inability to flexibly image different tissue volumes and shapes. Hand-held based optical imaging systems are a recent development for its improved portability, but are currently limited only to surface mapping. Herein, a novel optical imager, consisting primarily of a hand-held probe and a gain-modulated intensified charge coupled device (ICCD) detector, is developed towards both surface and tomographic breast imaging. The unique features of this hand-held probe based optical imager are its ability to; (i) image large tissue areas (5×10 sq. cm) in a single scan, (ii) reduce overall imaging time using a unique measurement geometry, and (iii) perform tomographic imaging for tumor three-dimensional (3-D) localization. Frequency-domain based experimental phantom studies have been performed on slab geometries (650 ml) under different target depths (1-2.5 cm), target volumes (0.45, 0.23 and 0.10 cc), fluorescence absorption contrast ratios (1:0, 1000:1 to 5:1), and number of targets (up to 3), using Indocyanine Green (ICG) as fluorescence contrast agents. An approximate extended Kalman filter based inverse algorithm has been adapted towards 3-D tomographic reconstructions. Single fluorescence target(s) was reconstructed when located: (i) up to 2.5 cm deep (at 1:0 contrast ratio) and 1.5 cm deep (up to 10:1 contrast ratio) for 0.45 cc-target; and (ii) 1.5 cm deep for target as small as 0.10 cc at 1:0 contrast ratio. In the case of multiple targets, two targets as close as 0.7 cm were tomographically resolved when located 1.5 cm deep. It was observed that performing multi-projection (here dual) based tomographic imaging using a priori target information from surface images, improved the target depth recovery over using single projection based imaging. From a total of 98 experimental phantom studies, the sensitivity and specificity of the imager was estimated as 81-86% and 43-50%, respectively. With 3-D tomographic imaging successfully demonstrated for the first time using a hand-held based optical imager, the clinical translation of this technology is promising upon further experimental validation from in-vitro and in-vivo studies.