937 resultados para DISK REFINING


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of the equatorial ligand on the electrochemical oxidation of the compounds [H3CCo(chel)B], where chel is bis (dimethylglyoximato), (DH)2; bis(salicylaldehyde)ethylenediimine, salen; bis(salicylaldehyde) o-phenylenediimine, salophen; bis(salicylaldehyde)cyclohexylenediimine, salcn; bis(acetylacetone) ethylenediimine, bae; and where B is pyridine when chel is (DH2), and dimethylformamide (DMF) when chel represents a Schiff base (salen, salcn, salophen and bae), was studied by means of cyclic voltammetry in DMF, 0.2 M in tetraethylammonium perchlorate, between 25 and -25°C, with a platinum disk working electrode. Absorption spectra in the visible and near ultraviolet regions for these compounds in DMF at 25°C were obtained. The complexes exhibit a reversible one-electron oxidation, at -20°C with scan rates >0.5 V s-; chemical reactions following electron transfer are not detected under these conditions. At slower potential or higher temperatures, the oxidized product decomposes chemically in a solvent-assisted (or nucleophile-assisted) reaction, yielding products which are electroactive in the applied potential range. The behavior of the [H3CCo (DH2)py] derivative is better described as a quasi-reversible charge transfer followed by an irreversible chemical reaction. Experimental evidence suggests that in the case of the [H3CCo(bae)] derivative at -20°C, the reactive -species is pentacoordinated and weakly adsorbed at the electrode surface. The value of E 1 2 and the energies of the first two absorption bands in the visible spectra reveal the ability of the studied complexes to donate and to delocalize electronic charge. © 1982.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this article a new technique for thermal neutron detection using pyroelectric ceramics is described. The detector system is basically constituted of a PZT (lead zirconate titanate) ceramic attached to an uranium disk. The energy released in the uranium fission gives rise to an electrical signal in the detector which is amplified by a lock-in system. The neutron beam impinging on the uranium disk was modulated with a cadmium chopper. Thermal neutron fluxes within the interval of 103 to 106 n/cm2 s have been detected using a U3O8 pellet with 20% enrichment in 235U. © 1992.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two hundred and seventy-seven multidrug resistant clinical isolates [K. pneumoniae, (N = 87); E coli, (N = 30); Salmonella typhimurium (N = 100); P. aeruginosa, (N = 30); S. aureus, (N = 30)] from hospitalized patients specimens, were tested in vitro for sensitivity to Ciprofloxacin. Application of the disk diffusion test and determination of the minimal inhibitory concentration by the microdilution method indicated that, almost all isolates were sensitive to the drug. Overall, S. aureus and P. aeruginosa were the less sensitive organisms. Ciprofloxacin-resistant mutants occurred at frequencies of > or = 10(-5)/CFU.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The articular disc of the temporomandibular joint was studied in fetuses (16 to 39 weeks of intrauterine life), infants (up to 4 months of age), dentulous adults (aged 30 to 39 years), and completely edentulous adults (aged 60 to 69 years) by scanning electron microscopy. The constituent bundles of collagen fibers were stratified and were oriented anteroposteriorly, laterolaterally, and obliquely in the middle portion of the disc. A ring of laterolateral bundles constituted the main feature of the thick posterior portion. In the anterior portion of the disc, the fibers were anteroposteriorly and obliquely oriented. On the superior and inferior surfaces of the disc, a thin layer of perpendicularly arranged collagen fibers covered the underlying, thick, laterolateral oriented collagen fibers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Essential oils from, Salvia officinalis L. (SO), Mentha sylvestris L. (MS), Casearia sylvestris Sw. (CS), Mentha piperita L. (MP), Ocimum micrantum Willd. (OM) and Mentha arvensis L. (MA), plants used in Brazilian popular medicine were extracted using method I, as described in the Brazilian Pharmacopoeia, in order to obtain the phytochemical profile and to evaluate their antimicrobial activity against the following microorganisms: Bacillus subtilis, Staphylococcus aureus, Micrococcus luteus, Escherichia coli, Serratia marcescens, Candida albicans and Aspergilus oryzae. Test was made by means of the disk-plaque diffusion test in liquid medium using 1% essential oil. In the disk-plaque diffusion test, all the essential oils exhibited activity against B. subtilis, but OM showed the greatest inhibition zone and was the only one to show activity against S. aureus. Samples of SO, MS, MP, OM and MA were active against M. luteus, E. coli and S. marcescens, while A. oryzae was sensitive to MS, MP, OM and MA. No sample, however, was active against C. albicans. In the liquid medium test, significant results were observed for OM and MA, which inhibited the growth of all microorganisms for 24 hours, and OM continued active against E. coli and A. oryzae until the last reading.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study of articular sounds using a computerized system (SonoPAK) in patients with temporomandibular disorders (TMD) of inflammatory origin revealed an increase of vibratory energy when compared to asymptomatic individuals. The following conclusions were reached: 1. The amount of vibratory energy registered in these patients ranged from 8.50 to 57.61 Hz. The major vibrations occurred in the middle of the mandibular opening cycle; 2. The mean vibratory energy measured at less than 300 Hz was between 5.70 and 48.64 Hz and at higher than 300 Hz was between 3.70 and 8.99 Hz; 3. The peak amplitude in the patients with inflammation ranged from 0.35 to 3.96 Pascal and the peak of frequency from 83.20 to 120.20 Hz.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Enterobacter spp. are considered important causing agents of infection, specially in hospitalized individuals. The natural resistance of these microorganisms and the great facility to develop resistance to new antimicrobial agents make this genus an important object of study. In this work, 176 strains isolated from various clinical samples were used from hospitalized patients (University Hospital Domingos Leonardo Cerávolo) and from clinic patients (Clinical Laboratory from Unoeste), both situated in Presidente Prudente - SP. E. cloacae (78.9%), E. aerogenes (7.9%) and E. (pantoea) agglomerans (3.9%) were the ones more frequently isolated. Eleven antimicrobial agents were tested by the disk diffusion method and around 90% of the strains presented resistance to the cephalotin, ampicillin and cefaclor. Strains of E. (pantoea) agglomerans presented wide profile of sensibility However one strain of E. cloacae presented resistance to all the antimicrobial agents. The antimicrobial agents with greater inhibitory activity were imipenem and cefepime, for this reason these antimicrobial agents could be the treatment of choice in emergencial therapeutic. This emergencial therapy can be applied with relative security, whereas the data obtained in this study show homogeneity in the profile of sensibility to these antimicrobial agents, independent of the infection site and from the isolated species. The ESBL enzyme could not be detected in no one of the strains by the double diffusion test.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow-injection system with a glassy carbon disk electrode modified with Prussian Blue film is proposed for the determination of persulfate in commercial samples of hair bleaching boosters by amperometry. The detection was obtained by chronoamperometric technique and the sample is injected into the electrochemical cell in a wall jet configuration. Potassium chloride at concentration of 0.1 mol L-1 acted as sample carrier at a flow rate of 4.0 mL min-1 and supporting-electrolyte. For 0.025 V (vs. Ag/AgCl) applied voltage, the proposed system handles ca. 160 samples per hour (1.0 10-4 - 1.0 10-3 mol L-1 of persulfate), consuming about 200 μL sample and 11 mg KCl per determination. Typical linear correlations between electrocatalytic current and persulfate concentration was ca. 0.9998. The detection limit is 9.0 10-5 mol L-1 and the calculated amperometric sensibility 3.6 103 μA L mol -1. Relative standard deviation (n =12) of a 1.0 10-4 mol L-1 sample is about 2.2%. The method was applied to persulfate determination in commercial hair-bleaching samples and results are in agreement with those obtained by titrimetry at 95% confidence level and good recoveries (95 - 112%) of spiked samples were found. © 2003 by MDPI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Before epídural steroids were used in chronic lumbar pain, subarachnoid injection of these agents was the treatment of choice. Although still preconized by some authors, this technique may lead to severe complications with neurological sequelae. This report aimed at describing a case of accidental subarachnoid injection of steroid associated to local anesthetics during epidural puncture to treat lumbar pain. CASE REPORT: Male patient, 46 years old, followed byneuro-surgery for presenting right sciatic pain for 9 month, refractory to clinical treatment due to L 4-L 5 disk protrusion confirmed by CT scan, without neurological deficit. Epidural puncture for pain treatment was performed in L 4-L 5 with 17G needle and 10 mL solution were injected containing 4 mL of 0.25% bupivacaine, 80 mg methylprednisolone and 4 mL of 0.9% saline. Although there has not been CSF reflux, 5 minutes after injection there were sensory block in T 4 and motor block in T 6, associated to blood pressure and heart rate decrease. CONCLUSIONS: Accidental subarachnoid injections with the association of steroids for pain relief may cause adverse effects. There are several risks, varying from mild transient symptoms to nervous injuries, including spinal cord injuries. Our patient had no sequelae from the accidental subarachnoid injection, probably because it has been a single injection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The objective of this study was to test the following hypothesis: the silica coating on ceramic surface increases the bond strength of resin cement to a ceramic. Materials and Methods: In-Ceram Alumina blocks were made and the ceramic surface was treated: G1 - sandblasting with 110-μm aluminum oxide particles; G2 - Rocatec System: tribochemicai silica coating (Rocatec-Pre powder + Rocatec-Plus powder + Rocatec-Sil); G3 - CoJet System: silica coating (CoJet-Sand) + ESPE-Sil. The ceramic blocks were cemented to composite blocks with Panavia F resin cement (under a load of 750 g/1 min). The cemented blocks were stored in distilled water at 37°C for 7 days and sectioned along the x and y axes with a diamond disk. Samples with an adhesive area of ca 0.8 mm 2 (n = 45) were obtained. The samples were attached to an adapted device for the microtensile test, which was performed in a universal testing machine (EMIC) at a crosshead speed of 1 mm/min. Results: The obtained results were submitted to ANOVA and Tukey's test. Mean values of tensile strength (MPa) and standard deviation values were: (G1) 16.8 ± 3.2; (G2) 30.6 ± 4.5; (G3) 33.0 ± 5.0. G2 and 63 presented greater tensile strength than G1. There was no significant difference between G2 and G3. All the failures took place at the ceramic/resin cement interface. Conclusion: The silica coating (Rocatec or CoJet systems) of the ceramic surface increased the bond strength between the Panavia F resin cement and alumina-based ceramic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study tested the hypothesis that the tribochemical silica coating on ceramic surfaces increases the bond strength of resin cement to a glass-infiltrated zirconium-based ceramic. Materials and Methods: Fifteen blocks of In-Ceram Zirconia from CEREC InLab (5 per group) and 15 composite blocks (Z-250) 5 mm x 5 mm x 4 mm were made. The ceramic surfaces were polished, and the blocks were divided into three groups: (1) airborne abrasion with 110-μm aluminum oxide particles; (2) Rocatec system, tribochemical silica coating; and (3) CoJet system, tribochemical silica coating. The ceramic blocks were cemented to the composite blocks using Panavia F according to the manufacturer's specifications. All samples were stored in 37°C distilled water for 7 days and later sectioned in two axes using a diamond disk under cooling to obtain specimens with a cross-sectional area of approximately 1 mm2 (n = 45). Each specimen was then attached with cyanoacrylate glue to an adapted device for the microtensile test, which was carried out on a universal testing machine. Results: The results were subjected to ANOVA and Tukey's test. Group 2 (23.0 ± 6.7 MPa) and group 3 (26.8 ± 7.4 MPa) showed greater bond strength than group 1 (15.1 ± 5.3 MPa). There was no significant difference between groups 2 and 3. All failures were in the adhesive zone. Conclusion: The hypothesis was confirmed - the tribochemical systems increased the bond strength between Panavia F and In-Ceram Zirconia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multiresistant Staphylococcus aureus constitutes an important public health problem, especially in view of its possible spread in nosocomial environments. In the present work, we analyzed the susceptibility profile of 80 S. aureus stains from human infections resistant to at least 10 drugs. For this study, the techniques used were the disk method and minimum inhibitory concentration (MIC) of the following drugs: cefuroxime, ciprofloxacin, clindamycin, erythromycin, gentamycin, imipenem, oxacillin, rifampicin, tetracycline and vancomycin, according the criteria of the National Committee for Clinical Laboratory Standards (NCCLS). Methicillin was included in the antibiogram as a marker, which is usually used in drugs selection for the treatment of staphylococcal infections. Results indicated that the most effective drug was vancomycin. For the other 10 drugs, the percentage of resistant strains ranged from 85% to 93.75%. In relation to the MICs, it was observed that vancomycin (MIC 90% = 0.615ug/ml) was the most effective drug; followed by rifampicin (MIC 90% = 2.6ug/ml) and ciprofloxacin (MIC 90% = 26.6ug/ml). The drugs that showed the least effective activity were cefuroxime, clindamycin, erythromycin, gentamycin, and oxacillin. On the other hand, observation of β-lactamase production revealed that most of the methicillin-resistant strains produced β-lactamase (83.7%), potentiating the risks of nosocomial infections. In general, vancomycin still continues to be one of the most effective drugs for staphylococcal infections therapy.