883 resultados para DEEP VEIN THROMBOSIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The venom of Lonomia obliqua caterpillar may induce a hemorrhagic syndrome in humans, and blood incoagulability by afibrinogenemia when intravenously injected in laboratory animals. The possible antithrombotic and thrombolytic activities of L. obliqua caterpillar bristle extract (LOCBE) were evaluated in this study. The minimal intravenous dose of the extract necessary to induce afibrinogenemia and anticoagulation was 3.0 and 10.0 µg protein/kg body weight for rabbits and rats, respectively. In rabbits, this dose induced total blood incoagulability for at least 10 h and did not reduce the weight of preformed venous thrombi, in contrast to streptokinase (30,000 IU/kg). In rats, pretreatment with 5.0 and 10.0 µg/kg LOCBE prevented the formation of thrombi induced by venous stasis or by injury to the venous endothelium. The dose of 5.0 µg/kg LOCBE did not modify blood coagulation assay parameters but increased bleeding time and decreased plasma factor XIII concentration. When the extract was administered to rats at the dose of 10.0 µg/kg, the blood was totally incoagulable for 6 h. These data show that LOCBE was effective in preventing experimental venous thrombosis in rats, justifying further studies using purified fractions of the extract to clarify the mechanisms of this effect.
Resumo:
O emprego da trombectomia na angioplastia primária demonstra bons resultados clínicos e angiográficos imediatos, por meio de redução da embolização distal e do fenômeno do no-reflow e otimização da perfusão miocárdica. Essa técnica, principalmente usada em artérias coronárias, em raras oportunidades é descrita quando empregada em pontes de safena aortocoronarianas. Relatamos o caso de um paciente de 67 anos com infarto agudo do miocárdio relacionado a oclusão de ponte de safena e submetido a trombectomia com bons resultados.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Doppler ultrasonography is an important tool for evaluating hepatic portal hemodynamics. However, no study in dogs of different body weights, in the range encountered in routine clinical veterinary practice, has been reported. It can be difficult to obtain an ideal insonation angle when evaluating the main portal vein, so evaluation of the right portal vein branch has been described in humans as an alternative. The aim of this study was to analyze, through Doppler ultrasonography, the hemodynamics in the right portal vein branch in dogs of different body weights.Methods: Thirty normal dogs were divided in three groups by weight, in order to establish normal values for mean velocity, flow volume and portal congestion index of the right portal vein branch by means of Doppler ultrasonography.Results: In all dogs ideal insonation angles were obtained for the right portal vein branch. The average velocity was similar in the three groups, but the portal congestion index and the flow volume differed, showing that the weight of the dog can influence these values.Conclusion: Doppler ultrasonography for the evaluation of flow in the right branch of the portal vein could be a viable alternative, or complement, to examining the main vessel segment. This is especially so in those animals in which an ideal insonation angle for examination of the main portal vein is hard to obtain. In addition, the weight of the dog must be considered for the correct evaluation of the portal system hemodynamics, particularly for portal blood flow and the congestion index.
Resumo:
Objectives. To evaluate the response of the pulpo-dentin complex following application of a resin-modified glass-ionomer cement or an adhesive system in deep cavities performed in human teeth.Methods. Deep class V cavities were prepared on the buccal surface of 26 premolars. In Group I the cavity walls (dentin) and enamel were conditioned with 32% phosphoric acid and the dentin adhesive system One Step (Bisco, Inc., Itasca, IL, USA) was applied. In Groups 2 and 3, before total etching and application of bonding agent, the cavity floor was lined with the resin-modified glass-ionomer cement-Vitrebond (3M ESPE Dental Products Division, St. Paul, MN, USA) or the calcium hydroxide cement-Dycal (control group, Dentsply, Mildford, DE, USA), respectively. The cavities were restored using light-cured Z-100 composite resin (3M ESPE). The teeth were extracted between 5 and 30 days and prepared for microscopic assessment. Serial sections were stained with H/E, Masson's trichrome, and Brown and Brenn techniques.Results. In Group 1, the inflammatory response was more evident than in Groups 2 and 3. Diffusion of dental material components across dentinal tubules was observed only in Group 1, in which the intensity of the pulp response increased as the remaining dentin thickness decreased. Bacteria were evidenced in the lateral walls of two samples (Group 2) which exhibited no inflammatory response or tissue disorganization.Conclusions. Based on the experimental conditions, it was concluded total acid etching followed by application of One Step bonding agent cannot be recommended as adequate procedures. In this clinical condition the cavity walls should be lined with a biocompatible dental material, such as Vitrebond or Dycal. 2003 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives: To evaluate the pulpo-dentin complex response to a dentin adhesive application in deep cavities performed in human teeth.Methods: Deep class V cavities were prepared on the buccal surface of 46 premolars. The remaining dentin of the axial wall received 10% phosphoric acid and dentin adhesive (group DA), or was protected before the acid and dentin adhesive application with calcium hydroxide cement (group CH). Half of the teeth, which received the acid application directly over the axial wall, were contaminated prior to the procedures with dental plaque collected from the patient's own teeth (group DAC). The plaque was placed on the dentin for 5 min and then the cavity was washed. All teeth were restored with a light-cured composite resin. The teeth were extracted after 7, 30 or 60 days and prepared according to normal histologic techniques. Serial sections were stained with WE, Masson's trichrome and Brown & Brenn technique for demonstration of bacteria.Results: the histopathologic evaluation showed that in groups DA and DAC, the inflammatory response was more evident than in group CH. Also, the intensity of the pulp reaction increased as the remaining dentin thickness decreased. There was no statistical difference in the inflammatory response between the groups DA and DAC.Conclusion: Based on the experimental conditions, we concluded that the All Bond 2 adhesive system, when applied on dentin in deep cavities, showed an acceptable biocompatibility. However, the intensity of the pulpo-dentin complex response depends on the remaining dentin thickness. (C) 1999 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives. The aim of this in vivo study was to evaluate the human dental pulp response when a one-bottle adhesive system was applied on etched or unetched deep dentine.Methods. Eighteen class V deep cavity preparations were divided in three groups: group 1-total etching + two coats of single bond (SB) + composite resin (Z-100); group 2-enamel etching + two coats of SB + Z-100, group 3-cavity floor lined with a calcium hydroxide liner (Dycal) + acid-etching of enamel and lateral walls + two coats of SB + Z-100. Two teeth were used as intact control group. After 30 days the teeth were extracted and processed through H and E, Masson's trichrome and Brown and Brenn staining techniques.Results. Moderate inflammatory response, disorganization of pulp tissue, as well as, deposition of thin layer of reactionary dentin were observed in group 1 teeth in which the remaining dentin thickness (RDT) was less than 300 mum. These histological findings appear to be related to long resin tags formation and bonding agent diffusion through dentinal tubules. In group 2, slight inflammatory response was observed only in one tooth in which the RDT was 162 mum. In group 3, all the teeth showed normal histological characteristics which were similar to the intact control group. Presence of bacteria was not correlated with the intensity of pulpal response. The patients reported no symptoms during the experiment. Radiographic evaluation showed no periapical pathology for any of the teeth,Significance and conclusions. Acid-etched deep dentin (RDT less than 300 mum) lined with SB causes more intense pulpal response than unetched deep dentin. Based on the results observed in the present study and the conditions in which it was carried out, we recommend the application of a biocompatible liner before etching deep dentin and applying SB. (C) 2002 Academy of Dental Materials. Published by Elsevier B.V. Ltd. All rights reserved.
Resumo:
Although veins and arteries present similar wall structures, there are differences which may be relevant in peripheral nerve reconstruction. Inside-out vein grafts (IOVG) have been satisfactorily used to repair both motor and sensitive nerves. However, the inside-out artery graft (IOAG) is a new technique and not fully investigated. Our study presents comparative morphological data on nerve regeneration achieved with IOVG and IOAG in the repair of Wistar rat sciatic nerves. Jugular veins and aorta arteries were harvested from donor animals and used inside-out to bridge a 10-mm gap. Animals were sacrificed at 10 weeks to evaluate nerve regeneration. Both techniques presented great variability in nervous tissue, though some animals showed satisfactory results. Different intensities of scarring processes might have interfered with nerve regeneration. Although IOVG and IOAG techniques showed similar morphometric results, in general, IOVG presented a closer-to-normal nerve organization than IOAG.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)