945 resultados para Computerized Axial Tomography
Resumo:
Introduction Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship. Methods Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared. Results Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort. Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion. When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions. Conclusions The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.
Resumo:
We prospectively investigated the potential of positron emission tomography (PET) using the somatostatin receptor (SSTR) analogue ⁶⁸Ga-DOTATATE and 2-deoxy-2[¹⁸F]fluoro-D-glucose (¹⁸F-FDG) in diffuse parenchymal lung disease (DPLD). Twenty-six patients (mean age 68.9 ± 11.0 years) with DPLD were recruited for ⁶⁸Ga-DOTATATE and ¹⁸F-FDG combined PET/high-resolution computed tomography (HRCT) studies. Ten patients had idiopathic pulmonary fibrosis (IPF), 12 patients had nonspecific interstitial pneumonia (NSIP), and 4 patients had other forms of DPLD. Using PET, the pulmonary tracer uptake (maximum standardized uptake value [SUV(max)]) was calculated. The distribution of PET tracer was compared to the distribution of lung parenchymal changes on HRCT. All patients demonstrated increased pulmonary PET signal with ⁶⁸Ga-DOTATATE and ¹⁸F-FDG. The distribution of parenchymal uptake was similar, with both tracers corresponding to the distribution of HRCT changes. The mean SUV(max) was 2.2 ± 0.7 for ⁶⁸Ga-DOTATATE and 2.8 ± 1.0 (t-test, p = .018) for ¹⁸F-FDG. The mean ⁶⁸Ga-DOTATATE SUV(max) in IPF patients was 2.5 ± 0.9, whereas it was 2.0 ± 0.7 (p = .235) in NSIP patients. The correlation between ⁶⁸Ga-DOTATATE SUV(max) and gas transfer (transfer factor of the lung for carbon monoxide [TLCO]) was r = -.34 (p = .127) and r = -.49 (p = .028) between ¹⁸F-FDG SUV(max) and TLCO. We provide noninvasive in vivo evidence in humans showing that SSTRs may be detected in the lungs of patients with DPLD in a similar distribution to sites of increased uptake of ¹⁸F-FDG on PET.
Resumo:
The determination of root canal length is a significant outcome predictor for endodontic treatments. The aim of this prospective, controlled clinical study was to analyze endodontic working length measurements in preexisting cone-beam computed tomography (CBCT) scans and to compare them with clinical root canal length determination by using an electronic apex locator (EAL).
Resumo:
Foreign bodies are common findings in the maxillofacial region, most commonly the result of accidents and physical aggression. Among the objects frequently found in the orofacial tissues are fragments of metal, plastic, wood, and glass. Visualization and exact identification of the location of these objects can be challenging but is of major importance prior to surgical removal. The present case report describes the use of cone beam computed tomography to locate, visualize, and surgically remove glass particles in the oral cavity.
Resumo:
The purpose of the present study was to compare conventional intraoral periapical radiographs (PA) with limited cone beam computed tomography (CBCT) for evaluation of mandibular molars prior to apical surgery. The apical extent and homogeneity of the root canal fillings (RCF) as well as the number of root canals were examined.
Resumo:
This retrospective radiographic study analyzed the dimensions of the alveolar bone in the posterior dentate mandible based on cone beam computed tomography (CBCT) images. A total of 56 CBCT images met the inclusion criteria, resulting in a sample size of 122 cross sections showing posterior mandibular teeth (premolars and molars). The thickness of the buccal and lingual bone walls was measured at two locations: 4 mm apical to the cementoenamel junction (measurement point 1, MP1) and at the middle of the root (measurement point 2, MP2). Further, alveolar bone width was assessed at the level of the most coronal buccal bone detectable (alveolar bone width 1, BW1) and at the superior border of the mandibular canal (alveolar bone width 2, BW2). The vertical distance between the two as well as the presence of a lingual undercut were also analyzed. There was a steady increase in buccal bone wall thickness from the first premolar to the second molar at both MP1 and MP2. BW1 at the level of the premolars was significantly thinner than that for molars. Alveolar bone height was constant for all teeth examined. For the selection of an appropriate postextraction treatment approach, analysis of the alveolar bone dimensions at the tooth to be extracted by means of CBCT can offer valuable information concerning bone volume and morphology at the future implant site.
Resumo:
The purpose of the present study was to evaluate the thickness and the anatomic characteristics of the Schneiderian membrane and cortical bone using limited cone beam computed tomography (CBCT) scannning in patients referred for planning of apical surgery of maxillary molars.
Resumo:
The objective of this study was to describe the use of a titanium 1.5 mm locking plate in the stabilization of atlantoaxial pathology in three toy breed dogs. Two dogs with atlantoaxial subluxation and another dog with an axial fracture, confirmed by diagnostic imaging, were stabilized via a ventral approach with a 1.5 mm titanium 5-hole locking butterfly-plate. Surgical reduction and stabilization were assessed by computed tomography and radiography after surgery. Follow-up evaluation for resolution of neurological signs and possible complications was performed in all three dogs. For long-term assessment, a telephone follow-up was performed. A considerable improvement of neurological signs occurred within two to four weeks after surgery. An excellent clinical outcome was identified in all three patients. Adequate stabilization and resolution of neurological signs in all three dogs was achieved. The stabilization of atlantoaxial surgical conditions in toy breeds with the 1.5 mm titanium 5-hole butterfly locking plate appears to be an effective means of surgical treatment.
Resumo:
OBJECTIVE: To analyze the biomechanical changes induced by partial lateral corpectomy (PLC) and a combination of PLC and hemilaminectomy in a T13-L3 spinal segment in nonchondrodystrophic dogs. STUDY DESIGN: In vitro biomechanical cadaveric study. SAMPLE POPULATION: T13-L3 spinal segments (n = 10) of nonchondrodystrophic dogs (weighing, 25-38 kg). METHODS: A computed tomography (CT) scan of each T13-L3 spinal segment was performed. A loading simulator for flexibility analysis was used to determine the range of motion (ROM) and neutral zone (NZ) during flexion/extension, lateral bending, and axial rotation. A servohydraulic testing machine was used to determine the changes in stiffness during compression, dorsoventral, and lateral shear. All spines were tested intact, after PLC in the left intervertebral space of L1-L2, and after a combination of PLC and hemilaminectomy. RESULTS: Statistically significant increases in ROM and NZ (P < .05) were detected during flexion/extension and lateral bending when PLC was performed. A significant increase in ROM (P < .001) was noted during axial rotation and flexion after PLC and hemilaminectomy. Stiffness decreased significantly during compression and dorsoventral shear after each procedure. Decreased stiffness during lateral shear was only significant after a combination of both procedures. CONCLUSION: PLC might lead to some spinal instability; these changes are enhanced when a hemilaminectomy is added.
Resumo:
Objective To develop an ultrasound-guided technique for retrobulbar nerve block in horses, and to compare the distribution of three different volumes of injected contrast medium (CM) (4, 8 and 12 mL), with the hypothesis that successful placement of the needle within the retractor bulbi muscle cone would lead to the most effective dispersal of CM towards the nerves leaving the orbital fissure. Study design Prospective experimental cadaver study. Animals Twenty equine cadavers. Methods Ultrasound-guided retrobulbar injections were performed in 40 cadaver orbits. Ultrasound visualization of needle placement within the retractor bulbi muscle cone and spread of injected CM towards the orbital fissure were scored. Needle position and destination of CM were then assessed using computerized tomography (CT), and comparisons performed between ultrasonographic visualization of orbital structures and success rate of injections (intraconal needle placement, CM reaching the orbital fissure). Results Higher scores for ultrasound visualization resulted in a higher success rate for intraconal CM injection, as documented on the CT images. Successful intraconal placement of the needle (22/34 orbits) resulted in CM always reaching the orbital fissure. CM also reached the orbital fissure in six orbits where needle placement was extraconal. With 4, 8 and 12 mL CM, the orbital fissure was reached in 16/34, 23/34 and 28/34 injections, respectively. Conclusion and clinical relevance The present study demonstrates the use of ultrasound for visualization of anatomical structures and needle placement during retrobulbar injections in equine orbits. However, this approach needs to be repeated in controlled clinical trials to assess practicability and effectiveness in clinical practice.
Resumo:
Minor brain injury is a frequent condition. Validated clinical decision rules can help in deciding whether a computed tomogram (CT) of the head is required. We hypothesized that institutional guidelines are not frequently used, and that psychological factors are a common reason for ordering an unnecessary CT.