974 resultados para Claramonte y Corroy, Andrés de, d. 1626.
Resumo:
The energy flow, dE/d eta, is studied at large pseudorapidities in proton-proton collisions at the LHC, for centre-of-mass energies of 0.9 and 7 TeV. The measurements are made using the CMS detector in the pseudorapidity range 3:15 < vertical bar eta vertical bar < 4.9, for both minimum-bias events and events with at least two high-momentum jets. The data are compared to various pp Monte Carlo event generators whose theoretical models and input parameter values are sensitive to the energy-flow measurements. Inclusion of multiple-parton interactions in the Monte Carlo event generators is found to improve the description of the energy-flow measurements.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The ability of the conotoxin p-TIA, a 19-amino acid peptide isolated from the marine snail Conus tulipa, to antagonize contractions induced by noradrenaline through activation of alpha(1A)-adrenoceptors in rat vas deferens, alpha(1B)-adrenoceptors in rat spleen and alpha(ID)-adrenoceptors in rat aorta, and to inhibit the binding of [I-125]HEAT (2-[[beta-(4-hydroxyphenyl)ethyl]aminomethyl]-1-tetralone) to membranes of human embryonic kidney (HEK) 293 cells expressing each of the recombinant rat alpha(1)-adrenoceptors was investigated. p-TIA (100 nM to 1 muM) antagonized the contractions of vas deferens and aorta in response to noradrenaline without affecting maximal effects and with similar potencies (pA(2)similar to7.2, n=4). This suggests that p-TIA is a competitive antagonist of alpha(1A)- and alpha(1D)-adrenoceptors with no selectivity between these subtypes. Incubation of p-TIA (30 to 300 nM) with rat spleen caused a significant reduction of the maximal response to noradrenaline, suggesting that p-TIA is a non-competitive antagonist at alpha(1B)-adrenoceptors. After receptor inactivation with phenoxybenzamine, the potency of p-TIA in inhibiting contractions was examined with similar occupancies (similar to25%) at each subtype. Its potency (pIC(50)) was 12 times higher in spleen (8.3 +/- 0.1, n=4) than in vas deferens (7.2 +/- 0.1, n=4) or aorta (7.2 0.1, n=4). In radioligand binding assays, p-TIA decreased the number of binding sites (B,,,,,,) in membranes from HEK293 cells expressing the rat alpha(1B)-adrenoceptors without affecting affinity (K-D), In contrast, in HEK293 cells expressing rat alpha(1A)- or alpha(1D)-adrenoceptors, p-TTA decreased the KD without affecting the B-max. It is concluded that p-TIA will be useful for distinguishing the role of particular alpha(1)-adrenoceptor subtypes in native tissues. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The immobilization of the ruthenium moiety Ru(NH3)4SO3 by reaction of trans-[Ru(NH3)4SO2(H2O)]2+ with silica gel functionalized with 3-(1-imidazolyl)propyl groups is reported. A 60% surface coverage was obtained in the proportion of the resulting material [=Si(CH2)3imN-Ru(NH3)4SO3]. The anchored Ru(II) complex was characterized and its reactivity investigated. Derivatives of CO, pyrazine, and isonicotinamide have been prepared and characterized by electronic and vibrational spectroscopies, as well as by chemical means. The [=Si(CH2)3imN-Ru(NH3)4SO4]Cl, obtained through oxidation of the corresponding ruthenium(II) sulfite species, has been characterized and the aquo and the oxalate derivative have been synthesized.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/. c to 1 TeV/. c. The surface flux ratio is measured to be 1.2766±0.0032(stat.)±0.0032(syst.), independent of the muon momentum, below 100 GeV/. c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by deep-underground experiments. © 2010.
Resumo:
A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO4) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100 MeV, associated with low-momentum muons. The muon critical energy in PbWO4 is measured to be 160+5 -68 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS Collaboration conducted a month-long data-taking exercise known as the Cosmic Run At Four Tesla in late 2008 in order to complete the commissioning of the experiment for extended operation. The operational lessons resulting from this exercise were addressed in the subsequent shutdown to better prepare CMS for LHC beams in 2009. The cosmic data collected have been invaluable to study the performance of the detectors, to commission the alignment and calibration techniques, and to make several cosmic ray measurements. The experimental setup, conditions, and principal achievements from this data-taking exercise are described along with a review of the preceding integration activities. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were executed, and the trigger synchronisation. Using data from extended cosmic ray runs, the muon, electron/photon, and jet triggers have been validated, and their performance evaluated. Efficiencies were found to be high, resolutions were found to be good, and rates as expected. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS experiment uses self-triggering arrays of drift tubes in the barrel muon trigger to perform the identification of the correct bunch crossing. The identification is unique only if the trigger chain is correctly synchronized. In this paper, the synchronization performed during an extended cosmic ray run is described and the results are reported. The random arrival time of cosmic ray muons allowed several synchronization aspects to be studied and a simple method for the fine synchronization of the Drift Tube Local Trigger at LHC to be developed. © 2010 IOP Publishing Ltd and SISSA.