952 resultados para Chromatography liquid with fluorescence detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The diagnosis of a periprosthetic joint infection (PJI) can be challenging, either because of the variable clinical presentation or because of previous antimicrobial treatment interfering with the detection of the pathogen. In recent years, various means to diagnose PJI have been analyzed. These include invasive and non-invasive laboratory tests, imaging procedures, and novel techniques such as sonication of implants and the use of molecular microbiology. In this review, both established and novel diagnostic procedures are presented. An algorithm for detecting PJI in patients with acute and chronic symptoms is proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A confocal imaging and image processing scheme is introduced to visualize and evaluate the spatial distribution of spectral information in tissue. The image data are recorded using a confocal laser-scanning microscope equipped with a detection unit that provides high spectral resolution. The processing scheme is based on spectral data, is less error-prone than intensity-based visualization and evaluation methods, and provides quantitative information on the composition of the sample. The method is tested and validated in the context of the development of dermal drug delivery systems, introducing a quantitative uptake indicator to compare the performances of different delivery systems is introduced. A drug penetration study was performed in vitro. The results show that the method is able to detect, visualize and measure spectral information in tissue. In the penetration study, uptake efficiencies of different experiment setups could be discriminated and quantitatively described. The developed uptake indicator is a step towards a quantitative assessment and, in a more general view apart from pharmaceutical research, provides valuable information on tissue composition. It can potentially be used for clinical in vitro and in vivo applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Telomeres have emerged as crucial cellular elements in aging and various diseases including cancer. To measure the average length of telomere repeats in cells, we describe our protocols that use fluorescent in situ hybridization (FISH) with labeled peptide nucleic acid (PNA) probes specific for telomere repeats in combination with fluorescence measurements by flow cytometry (flow FISH). Flow FISH analysis can be performed using commercially available flow cytometers, and has the unique advantage over other methods for measuring telomere length of providing multi-parameter information on the length of telomere repeats in thousands of individual cells. The accuracy and reproducibility of the measurements is augmented by the automation of most pipetting (aspiration and dispensing) steps, and by including an internal standard (control cells) with a known telomere length in every tube. The basic protocol for the analysis of nucleated blood cells from 22 different individuals takes about 12 h spread over 2-3 days.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Invasive exotic plants have altered natural ecosystems across much of North America. In the Midwest, the presence of invasive plants is increasing rapidly, causing changes in ecosystem patterns and processes. Early detection has become a key component in invasive plant management and in the detection of ecosystem change. Risk assessment through predictive modeling has been a useful resource for monitoring and assisting with treatment decisions for invasive plants. Predictive models were developed to assist with early detection of ten target invasive plants in the Great Lakes Network of the National Park Service and for garlic mustard throughout the Upper Peninsula of Michigan. These multi-criteria risk models utilize geographic information system (GIS) data to predict the areas at highest risk for three phases of invasion: introduction, establishment, and spread. An accuracy assessment of the models for the ten target plants in the Great Lakes Network showed an average overall accuracy of 86.3%. The model developed for garlic mustard in the Upper Peninsula resulted in an accuracy of 99.0%. Used as one of many resources, the risk maps created from the model outputs will assist with the detection of ecosystem change, the monitoring of plant invasions, and the management of invasive plants through prioritized control efforts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapid diagnostic tests (RDT) are sometimes recommended to improve the home-based management of malaria. The accuracy of an RDT for the detection of clinical malaria and the presence of malarial parasites has recently been evaluated in a high-transmission area of southern Mali. During the same study, the cost-effectiveness of a 'test-and-treat' strategy for the home-based management of malaria (based on an artemisinin-combination therapy) was compared with that of a 'treat-all' strategy. Overall, 301 patients, of all ages, each of whom had been considered a presumptive case of uncomplicated malaria by a village healthworker, were checked with a commercial RDT (Paracheck-Pf). The sensitivity, specificity, and positive and negative predictive values of this test, compared with the results of microscopy and two different definitions of clinical malaria, were then determined. The RDT was found to be 82.9% sensitive (with a 95% confidence interval of 78.0%-87.1%) and 78.9% (63.9%-89.7%) specific compared with the detection of parasites by microscopy. In the detection of clinical malaria, it was 95.2% (91.3%-97.6%) sensitive and 57.4% (48.2%-66.2%) specific compared with a general practitioner's diagnosis of the disease, and 100.0% (94.5%-100.0%) sensitive but only 30.2% (24.8%-36.2%) specific when compared against the fulfillment of the World Health Organization's (2003) research criteria for uncomplicated malaria. Among children aged 0-5 years, the cost of the 'test-and-treat' strategy, per episode, was about twice that of the 'treat-all' (U.S.$1.0. v. U.S.$0.5). In older subjects, however, the two strategies were equally costly (approximately U.S.$2/episode). In conclusion, for children aged 0-5 years in a high-transmission area of sub-Saharan Africa, use of the RDT was not cost-effective compared with the presumptive treatment of malaria with an ACT. In older patients, use of the RDT did not reduce costs. The question remains whether either of the strategies investigated can be made affordable for the affected population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The epithelial calcium channel TRPV6 is upregulated in breast carcinoma compared with normal mammary gland tissue. The selective estrogen receptor modulator tamoxifen is widely used in breast cancer therapy. Previously, we showed that tamoxifen inhibits calcium uptake in TRPV6-transfected Xenopus oocytes. In this study, we examined the effect of tamoxifen on TRPV6 function and intracellular calcium homeostasis in MCF-7 breast cancer cells transiently transfected with EYFP-C1-TRPV6. TRPV6 activity was measured with fluorescence microscopy using Fura-2. The basal calcium level was higher in transfected cells compared with nontransfected cells in calcium-containing solution but not in nominally calcium-free buffer. Basal influxes of calcium and barium were also increased. In transfected cells, 10 mumol/L tamoxifen reduced the basal intracellular calcium concentration to the basal calcium level of nontransfected cells. Tamoxifen decreased the transport rates of calcium and barium in transfected cells by 50%. This inhibitory effect was not blocked by the estrogen receptor antagonist, ICI 182,720. Similarly, a tamoxifen-induced inhibitory effect was also observed in MDA-MB-231 estrogen receptor-negative cells. The effect of tamoxifen was completely blocked by activation of protein kinase C. Inhibiting protein kinase C with calphostin C decreased TRPV6 activity but did not alter the effect of tamoxifen. These findings illustrate how tamoxifen might be effective in estrogen receptor-negative breast carcinomas and suggest that the therapeutic effect of tamoxifen and protein kinase C inhibitors used in breast cancer therapy might involve TRPV6-mediated calcium entry. This study highlights a possible role of TRPV6 as therapeutic target in breast cancer therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With prenatal detection of hydronephrosis and technological advances in surgical equipment, the management of lower urinary tract obstruction has evolved to include prenatal surgical intervention. Surgical intervention, was based upon the rationale that restoring amniotic fluid to normal levels by shunting fetal urine from the obstructed urinary system to the amniotic space would prevent lung hypoplasia and, thus, improve neonatal survival. Inaddition, relief of the obstruction would also reduce back pressure and reduce injury to the developing nephron, thus improving long-term renal function postnatally. However, this remains investigational, and the vast majority of affected infants are treated soon after birth. We have experience since 1991 with prenatal treatment of megacystis. In 23 cases of 50 detected megacystis with oligohydramnion in male and without other abnormalities a prenatal intervention by bladderpunction and in 12 cases additional vesicoamniotic shunt placement was performed. The prognosis of megacystis with oligohydramnion is stated with a survival rate of 10-30%. In our group 54% (13 children) survived. Also we want present 56 cases of urethral valves with a postnatal transurethral intervention. With a follow up time from 8.6 (3 to 15) years we attend 34 children (60%) with normal renal function, 21% (12) with mild or moderate renal insufficiency and there was a kidney transplantation in 6 cases necessary. With our multidisciplinary presentation we want to discuss the indication, interdisciplinary aspects,risks and the follow up of pre- and postnatal intervention in such cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since tako-tsubo syndrome (TS) frequently appears soon after stroke (usually stroke involving the insular cortex), it is believed to be a consequence rather than a cause of stroke. Herein, we describe a 70-year-old woman presenting with a left middle cerebral artery stroke (involving the insular cortex) who developed a further contralateral ischemic stroke with concomitant detection of a transient intracardiac mural thrombus attributable to TS. It can reasonably be maintained that that in our patient insular stroke triggered the TS, which in turn became the embolic cause of a further stroke. Given the association between TS and the risk of embolic stroke, congestive heart failure and sudden death, stroke physicians need to promptly detect and appropriately manage this condition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-resolution chemical depth profiling measurements of copper films are presented. The 10 μm thick copper test samples were electrodeposited on a Si-supported Cu seed under galvanostatic conditions in the presence of particular plating additives (SPS, Imep, PEI, and PAG) used in the semiconductor industry for the on-chip metallization of interconnects. To probe the trend of these plating additives toward inclusion into the deposit upon growth, quantitative elemental mass spectrometric measurements at trace level concentration were conducted by using a sensitive miniature laser ablation ionization mass spectrometer (LIMS), originally designed and developed for in situ space exploration. An ultrashort pulsed laser system (τ ∼ 190 fs, λ = 775 nm) was used for ablation and ionization of sample material. We show that with our LIMS system, quantitative chemical mass spectrometric analysis with an ablation rate at the subnanometer level per single laser shot can be conducted. The measurement capabilities of our instrument, including the high vertical depth resolution coupled with high detection sensitivity of ∼10 ppb, high dynamic range ≥10(8), measurement accuracy and precision, is of considerable interest in various fields of application, where investigations with high lateral and vertical resolution of the chemical composition of solid materials are required, these include, e.g., wafers from semiconductor industry or studies on space weathered samples in space research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND A precise detection of volume change allows for better estimating the biological behavior of the lung nodules. Postprocessing tools with automated detection, segmentation, and volumetric analysis of lung nodules may expedite radiological processes and give additional confidence to the radiologists. PURPOSE To compare two different postprocessing software algorithms (LMS Lung, Median Technologies; LungCARE®, Siemens) in CT volumetric measurement and to analyze the effect of soft (B30) and hard reconstruction filter (B70) on automated volume measurement. MATERIAL AND METHODS Between January 2010 and April 2010, 45 patients with a total of 113 pulmonary nodules were included. The CT exam was performed on a 64-row multidetector CT scanner (Somatom Sensation, Siemens, Erlangen, Germany) with the following parameters: collimation, 24x1.2 mm; pitch, 1.15; voltage, 120 kVp; reference tube current-time, 100 mAs. Automated volumetric measurement of each lung nodule was performed with the two different postprocessing algorithms based on two reconstruction filters (B30 and B70). The average relative volume measurement difference (VME%) and the limits of agreement between two methods were used for comparison. RESULTS At soft reconstruction filters the LMS system produced mean nodule volumes that were 34.1% (P < 0.0001) larger than those by LungCARE® system. The VME% was 42.2% with a limit of agreement between -53.9% and 138.4%.The volume measurement with soft filters (B30) was significantly larger than with hard filters (B70); 11.2% for LMS and 1.6% for LungCARE®, respectively (both with P < 0.05). LMS measured greater volumes with both filters, 13.6% for soft and 3.8% for hard filters, respectively (P < 0.01 and P > 0.05). CONCLUSION There is a substantial inter-software (LMS/LungCARE®) as well as intra-software variability (B30/B70) in lung nodule volume measurement; therefore, it is mandatory to use the same equipment with the same reconstruction filter for the follow-up of lung nodule volume.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Field deployments of the Aerodyne Aerosol Mass Spectrometer (AMS) have significantly advanced real-time measurements and source apportionment of non-refractory particulate matter. However, the cost and complex maintenance requirements of the AMS make its deployment at sufficient sites to determine regional characteristics impractical. Furthermore, the negligible transmission efficiency of the AMS inlet for supermicron particles significantly limits the characterization of their chemical nature and contributing sources. In this study, we utilize the AMS to characterize the water-soluble organic fingerprint of ambient particles collected onto conventional quartz filters, which are routinely sampled at many air quality sites. The method was applied to 256 particulate matter (PM) filter samples (PM1, PM2:5, and PM10, i.e., PM with aerodynamic diameters smaller than 1, 2.5, and 10 μm, respectively), collected at 16 urban and rural sites during summer and winter. We show that the results obtained by the present technique compare well with those from co-located online measurements, e.g., AMS or Aerosol Chemical Speciation Monitor (ACSM). The bulk recoveries of organic aerosol (60–91 %) achieved using this technique, together with low detection limits (0.8 μg of organic aerosol on the analyzed filter fraction) allow its application to environmental samples. We will discuss the recovery variability of individual hydrocarbon ions, ions containing oxygen, and other ions. The performance of such data in source apportionment is assessed in comparison to ACSM data. Recoveries of organic components related to different sources as traffic, wood burning, and secondary organic aerosol are presented. This technique, while subjected to the limitations inherent to filter-based measurements (e.g., filter artifacts and limited time resolution) may be used to enhance the AMS capabilities in measuring size-fractionated, spatially resolved longterm data sets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To determine the effect of the use of iodinated contrast agents on the formation of DNA double-strand breaks during chest computed tomography (CT). MATERIALS AND METHODS This study was approved by the institutional review board, and written informed consent was obtained from all patients. This single-center study was performed at a university hospital. A total of 179 patients underwent contrast material-enhanced CT, and 66 patients underwent unenhanced CT. Blood samples were taken from these patients prior to and immediately after CT. In these blood samples, the average number of phosphorylated histone H2AX (γH2AX) foci per lymphocyte was determined with fluorescence microscopy. Significant differences between the number of foci that developed in both the presence and the absence of the contrast agent were tested by using an independent sample t test. RESULTS γH2AX foci levels were increased in both groups after CT. Patients who underwent contrast-enhanced CT had an increased amount of DNA radiation damage (mean increase ± standard error of the mean, 0.056 foci per cell ± 0.009). This increase was 107% ± 19 higher than that in patients who underwent unenhanced CT (mean increase, 0.027 foci per cell ± 0.014). CONCLUSION The application of iodinated contrast agents during diagnostic x-ray procedures, such as chest CT, leads to a clear increase in the level of radiation-induced DNA damage as assessed with γH2AX foci formation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The attentional blink (AB) is a fundamental limitation of the ability to select relevant information from irrelevant information. It can be observed with the detection rate in an AB task as well as with the corresponding P300 amplitude of the event-related potential. In previous research, however, correlations between these two levels of observation were weak and rather inconsistent. A possible explanation of this finding might be that multiple processes underlie the AB and, thus, obscure a possible relationship between AB-related detection rate and the corresponding P300 amplitude. The present study investigated this assumption by applying a fixed-links modeling approach to represent behavioral individual differences in the AB as a latent variable. Concurrently, this approach enabled us to control for additional sources of variance in AB performance by deriving two additional latent variables. The correlation between the latent variable reflecting behavioral individual differences in AB magnitude and a corresponding latent variable derived from the P300 amplitude was high (r=.70). Furthermore, this correlation was considerably stronger than the correlations of other behavioral measures of the AB magnitude with their psychophysiological counterparts (all rs<.40). Our findings clearly indicate that the systematic disentangling of various sources of variance by utilizing the fixed-links modeling approach is a promising tool to investigate behavioral individual differences in the AB and possible psychophysiological correlates of these individual differences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Application of pressure-driven laminar flow has an impact on zone and boundary dispersion in open tubular CE. The GENTRANS dynamic simulator for electrophoresis was extended with Taylor-Aris diffusivity which accounts for dispersion due to the parabolic flow profile associated with pressure-driven flow. Effective diffusivity of analyte and system zones as functions of the capillary diameter and the amount of flow in comparison to molecular diffusion alone were studied for configurations with concomitant action of imposed hydrodynamic flow and electroosmosis. For selected examples under realistic experimental conditions, simulation data are compared with those monitored experimentally using modular CE setups featuring both capacitively coupled contactless conductivity and UV absorbance detection along a 50 μm id fused-silica capillary of 90 cm total length. The data presented indicate that inclusion of flow profile based Taylor-Aris diffusivity provides realistic simulation data for analyte and system peaks, particularly those monitored in CE with conductivity detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The copines, named and first described by Creutz et al. (1998), comprise a two C2 domain-containing protein family that can aggregate phosphatidylserine membranes in a calcium-dependent manner. Although no enzymatic function has been attributed to copines, their carboxyl terminus shows homology to the A domain found in integrins that allows binding of magnesium ions. The secondary structure of A domains resembles a Rossmann fold, which can bind dinucleotides and is present in a number of intracellular enzymes. Due to a crossreacting activity of Mik b 1, an antibody to the IL-2R b chain, we were able to serendipitously clone human copine III (CIII). CIII is 65% identical to copine I (CI) and the 5 kb CIII transcript is expressed ubiquitously as determined by a multitissue Northern blot. A polyclonal antibody generated against the carboxyl terminus of CIII recognized CIII in immunoblots and immunoprecipitations. Phosphorylation of CIII was observed on serine and threonine residues, as determined by phosphoamino acid analysis. ^ Experiments were designed to determine whether or not any enzymatic activity, specifically kinase activity, was intrinsic to or associated with CIII. In vitro and in gel kinase assays were performed using transfected HA-tagged CI and CIII, immunoprecipitated endogenous CIII and purified endogenous CIII. The exogenous substrate MBP was phosphorylated in all in vitro kinase assays containing CIII protein purification and column chromatography expertise with me. ^