972 resultados para CT, Radiation Dose, Image Quality
Resumo:
The purpose of this study was to determine whether there was any evidence of psychosexual morbidity among men who experienced radical radiation treatment for prostate cancer. With relatively little known or available retrospective data on the psychosexual implications of radical radiation treatment in men with prostate cancer, this study posited eight research questions which provided the basis for the research. Fifty men from Southern Ontario, between the ages of 52 to 78 years, were included in the study. They had been previously randomized to a clinical trial comparing radical radiation therapy by external beam radiation, or radical radiation using a combination of a temporary iridium implant plus external beam radiation, for localized or locally advanced prostate cancer. Assessment of sexual functioning, drive, attitudes, body image, and sexual satisfaction was drawn from a multidimensional approach, since psychosexuality was viewed as having an impact on biological, psychological, and sociological domains of functioning. Medical chart reviews, semi-structured interviews, demographical profiles of each participant, and the Derogatis Sexual Functioning Inventory (DSFI) were the methods used to collect data over a four-month period. Both quantitative and qualitative research methods were incorporated in the design and evaluation of the study. Frequencies, contingency analysis, Pearson's coefficient of correlation, t-tests, and ANOVA comprised the quantitative analysis. Data obtained from audio-taped interviews were analyzed qualitatively, and used for offering further insight and for facilitating the quantitative aspect of the analysis. Overall, there was sufficient evidence to suggest psychosexual morbidity among men who were treated with radiation therapy for prostate cancer. As well,there were a number of significant findings available to answer all of the posited research questions. The most significant findings were noted in post-treatment erectile ability and sexual activity. A post-treatment change in erectile ability was reported by eighty percent of men. Sixty percent of men noted a decrease in their ability to achieve an erection by reporting some morning stiffness only, penile rigidity insufficient for penetration, decreased control of erection, and loss of spontaneous erection. Other contributing factors associated with change in erectile status were: pain or altering sensation of orgasm, blood in ejaculate, pain and decreased amount of ejaculate, and penile numbness or pain. Eighty-two percent of men experienced a post-treatment change in sexual function, primarily due to the impact of decreasing erectile status. Only seven men reported that they experienced a decrease in desire mentally, whereas the vast majority did not experience any change in desire. Changes in foreplay, stress with optimal sexual positioning, and reduced spontaneity of sex, were other factors reported with the changes in sexual activity. The findings in this study broaden our understanding of what middle- to later-aged men feel and experience as they venture onward following treatment. This was the first study that evaluated available prospective data on pre-treatment erectile status and sexual activity. As well, this study was the first (with participant compliance rates of 100 percent) to have included an interview format to capture the views of such a large number of men. This study concluded with recommendations and implications for future research and practice as we move in the direction of understanding what is necessary for preserving psychosexual well being and enhancing quality of life in men treated with radiation therapy for prostate cancer.
Resumo:
En radiothérapie, la tomodensitométrie (CT) fournit l’information anatomique du patient utile au calcul de dose durant la planification de traitement. Afin de considérer la composition hétérogène des tissus, des techniques de calcul telles que la méthode Monte Carlo sont nécessaires pour calculer la dose de manière exacte. L’importation des images CT dans un tel calcul exige que chaque voxel exprimé en unité Hounsfield (HU) soit converti en une valeur physique telle que la densité électronique (ED). Cette conversion est habituellement effectuée à l’aide d’une courbe d’étalonnage HU-ED. Une anomalie ou artefact qui apparaît dans une image CT avant l’étalonnage est susceptible d’assigner un mauvais tissu à un voxel. Ces erreurs peuvent causer une perte cruciale de fiabilité du calcul de dose. Ce travail vise à attribuer une valeur exacte aux voxels d’images CT afin d’assurer la fiabilité des calculs de dose durant la planification de traitement en radiothérapie. Pour y parvenir, une étude est réalisée sur les artefacts qui sont reproduits par simulation Monte Carlo. Pour réduire le temps de calcul, les simulations sont parallélisées et transposées sur un superordinateur. Une étude de sensibilité des nombres HU en présence d’artefacts est ensuite réalisée par une analyse statistique des histogrammes. À l’origine de nombreux artefacts, le durcissement de faisceau est étudié davantage. Une revue sur l’état de l’art en matière de correction du durcissement de faisceau est présentée suivi d’une démonstration explicite d’une correction empirique.
Resumo:
Des efforts de recherche considérables ont été déployés afin d'améliorer les résultats de traitement de cancers pulmonaires. L'étude de la déformation de l'anatomie du patient causée par la ventilation pulmonaire est au coeur du processus de planification de traitement radio-oncologique. À l'aide d'images de tomodensitométrie quadridimensionnelles (4DCT), une simulation dosimétrique peut être calculée sur les 10 ensembles d'images du 4DCT. Une méthode doit être employée afin de recombiner la dose de radiation calculée sur les 10 anatomies représentant une phase du cycle respiratoire. L'utilisation de recalage déformable d'images (DIR), une méthode de traitement d'images numériques, génère neuf champs vectoriels de déformation permettant de rapporter neuf ensembles d'images sur un ensemble de référence correspondant habituellement à la phase d'expiration profonde du cycle respiratoire. L'objectif de ce projet est d'établir une méthode de génération de champs de déformation à l'aide de la DIR conjointement à une méthode de validation de leur précision. Pour y parvenir, une méthode de segmentation automatique basée sur la déformation surfacique de surface à été créée. Cet algorithme permet d'obtenir un champ de déformation surfacique qui décrit le mouvement de l'enveloppe pulmonaire. Une interpolation volumétrique est ensuite appliquée dans le volume pulmonaire afin d'approximer la déformation interne des poumons. Finalement, une représentation en graphe de la vascularisation interne du poumon a été développée afin de permettre la validation du champ de déformation. Chez 15 patients, une erreur de recouvrement volumique de 7.6 ± 2.5[%] / 6.8 ± 2.1[%] et une différence relative des volumes de 6.8 ± 2.4 [%] / 5.9 ± 1.9 [%] ont été calculées pour le poumon gauche et droit respectivement. Une distance symétrique moyenne 0.8 ± 0.2 [mm] / 0.8 ± 0.2 [mm], une distance symétrique moyenne quadratique de 1.2 ± 0.2 [mm] / 1.3 ± 0.3 [mm] et une distance symétrique maximale 7.7 ± 2.4 [mm] / 10.2 ± 5.2 [mm] ont aussi été calculées pour le poumon gauche et droit respectivement. Finalement, 320 ± 51 bifurcations ont été détectées dans le poumons droit d'un patient, soit 92 ± 10 et 228 ± 45 bifurcations dans la portion supérieure et inférieure respectivement. Nous avons été en mesure d'obtenir des champs de déformation nécessaires pour la recombinaison de dose lors de la planification de traitement radio-oncologique à l'aide de la méthode de déformation hiérarchique des surfaces. Nous avons été en mesure de détecter les bifurcations de la vascularisation pour la validation de ces champs de déformation.
Resumo:
Tout en voulant inclure la fiction télévisuelle brésilienne parmi les fictions de qualité, cette recherche analyse l’émergence et l’évolution du concept de qualité dans le panorama télévisuel brésilien. Examinant l’histoire de la télédramaturgie au Brésil, depuis les téléthéâtres jusqu’aux microséries réalisées par Luiz Fernando Carvalho, en particulier la microsérie Capitu (2008), nous suggérons que la production fictionnelle brésilienne a atteint un niveau de qualité sophistiquée et avant-gardiste qui illustre une alternative au style préconisé par la formule des séries télévisées américaines qui se regroupent sous l’étiquette de la Quality TV. De plus, le raffinement de la microsérie contribue à la légitimation de la valeur artistique de la télévision à partir de caractéristiques télévisuelles, contrairement à la production fictionnelle américaine dont l’esthétique plutôt cinématographique finit par discréditer davantage le petit écran. Finalement, nous souhaitons démontrer l’importance des innovations esthétiques que cette microsérie a apportées au sein d’une sphère médiatique qui semble se diriger progressivement et rapidement vers l’uniformisation du langage télévisuel et de son contenu.
Resumo:
La captación de glucosa y su conversión en lactato juega un papel fundamental en el metabolismo tumoral, independientemente de la concentración de oxígeno presente en el tejido (efecto Warburg). Sin embrago, dicha captación varía de un tipo tumoral a otro, y dentro del mismo tumor, situación que podría depender de las características microambientales tumorales (fluctuaciones de oxígeno, presencia de otros tipos celulares) y de factores estresores asociados a los tratamientos. Se estudió el efecto de la hipoxia-reoxigenación (HR) y las radiaciones ionizantes (RI) sobre la captación de glucosa, en cultivos de líneas tumorales MCF-7 y HT-29, cultivadas de forma aislada o en cocultivo con la línea celular EAhy296. Se encontró que la captación de glucosa en HR es diferente para lo descrito en condiciones de hipoxia permanente y que es modificada en el cocultivo. Se identificaron poblaciones celulares dentro de la misma línea celular, de alta y baja captación de glucosa, lo que implicaría una simbiosis metabólica de la célula como respuesta adaptativa a las condiciones tumorales. Se evaluó la expresión de NRF2 y la translocación nuclear de NRF2 y HIF1a, como vías de respuesta a estrés celular e hipoxia. La translocación nuclear de las proteínas evaluadas explicaría el comportamiento metabólico de las células tumorales de seno, pero no de colon, por lo cual deben existir otras vías metabólicas implicadas. Las diferencias en el comportamiento de las células tumorales en HR en relación con hipoxia permitirá realizar planeaciones dosimétricas más dinámicas, que reevalúen las condiciones de oxigenación tumoral constantemente.
Resumo:
An X-ray micro-tomography system has been designed that is dedicated to the low-dose imaging of radiation sensitive living organisms and has been used to image the early development of the first few days of plant development immediately after germination. The system is based on third-generation X-ray micro-tomography system and consists of an X-ray tube, two-dimensional X-ray detector and a mechanical sample manipulation stage. The X-ray source is a 50 kVp X-ray tube with a silver target with a filter to centre the X-ray spectrum on 22 keV.A 100 mm diameter X-ray image intensifier (XRII) is used to collect the two-dimensional projection images. The rotation tomography table incorporates a linear translation mechanism to eliminate ring artefact that is commonly associated with third-generation tomography systems' Developing maize seeds (Triticum aestivum) have been imaged using the system with a cubic voxel linear dimension of 100 mum, over a diameter of 25 mm and the root lengths and volumes measured. The X-ray dose to the plants was also assessed and found to have no effect on the plant root development. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
The quality control optimization of medical processes that use ionizing radiation in the treatment of diseases like cancer is a key element for patient safety and success of treatment. The major medical application of radiation is radiotherapy, i.e. the delivery of dose levels to well-defined target tissues of a patient with the purpose of eliminating a disease. The need of an accurate tumour-edge definition with the purpose of preserving healthy surrounding tissue demands rigorous radiation treatment planning. Dosimetric methods are used for dose distribution mapping region of interest to assure that the prescribed dose and the irradiated region are correct. The Fricke gel (FXG) is the main dosimeter that supplies visualization of the three-dimensional (3D) dose distribution. In this work the dosimetric characteristics of the modified Fricke dosimeter produced at the Radiation Metrology Centre of the Institute of Energetic and Nuclear Research (IPEN) such as gel concentration dose response dependence, xylenol orange addition influence, dose response between 5 and 50Gy and signal stability were evaluated by magnetic resonance imaging (MRI). Using the same gel solution, breast simulators (phantoms) were shaped and absorbed dose distributions were imaged by MRI at the Nuclear Resonance Laboratory of the Physics Institute of Sao Paulo University. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
A survey of pediatric radiological examinations was carried out in a reference pediatric hospital of the city of Sao Paulo. in order to investigate the doses to children undergoing conventional X-ray examinations. The results showed that the majority of pediatric patients are below 4 years, and that about 80% of the examinations correspond to chest projections. Doses to typical radiological examinations were measured in vivo with thermoluminescent dosimeters (LiF: Mg, Ti and LiF: Mg, Cu, P) attached to the skin of the children to determine entrance surface dose (ESD). Also homogeneous phantoms were used to obtain ESD to younger children, because the technique uses a so small kVp that the dosimeters would produce an artifact image in the patient radiograph. Four kinds of pediatric examinations were investigated: three conventional examinations (chest, skull and abdomen) and a fluoroscopic procedure (barium swallow). Relevant information about kVp and mAs values used in the examinations was collected, and we discuss how these parameters can affect the ESD. The ESD values measured in this work are compared to reference levels published by the European Commission for pediatric patients. The results obtained (third-quartile of the ESD distribution) for chest AP examinations in three age groups were: 0.056 mGy (2-4 years old); 0,068 mGy (5-9 years old)-. 0.069 mGy (10-15 years old). All of them are below the European reference level (0.100mGy). ESD values measured to the older age group in skull and abdomen AP radiographs (mean values 3.44 and 1.20mGy, respectively) are above the European reference levels (1.5mGy to skull and 1.0 mGy to abdomen). ESD values measured in the barium swallow examination reached 10 mGy in skin regions corresponding to thyroid and esophagus. It was noticed during this survey that some technicians use, improperly, X-ray fluoroscopy in conventional examinations to help them in positioning the patient. The results presented here are a preliminary survey of doses in pediatric radiological examinations and they show that it is necessary to investigate the technical parameters to perform the radiographs. to introduce practices to control pediatric patient`s doses and to improve the personnel training to perform a pediatric examination. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The protective shielding design of a mammography facility requires the knowledge of the scattered radiation by the patient and image receptor components. The shape and intensity of secondary x-ray beams depend on the kVp applied to the x-ray tube, target/filter combination, primary x-ray field size, and scattering angle. Currently, shielding calculations for mammography facilities are performed based on scatter fraction data for Mo/Mo target/filter, even though modern mammography equipment is designed with different anode/filter combinations. In this work we present scatter fraction data evaluated based on the x-ray spectra produced by a Mo/Mo, Mo/Rh and W/Rh target/filter, for 25, 30 and 35 kV tube voltages and scattering angles between 30 and 165 degrees. Three mammography phantoms were irradiated and the scattered radiation was measured with a CdZnTe detector. The primary x-ray spectra were computed with a semiempirical model based on the air kerma and HVL measured with an ionization chamber. The results point out that the scatter fraction values are higher for W/Rh than for Mo/Mo and Mo/Rh, although the primary and scattered air kerma are lower for W/Rh than for Mo/Mo and Mo/Rh target/filter combinations. The scatter fractions computed in this work were applied in a shielding design calculation in order to evaluate shielding requirements for each of these target/filter combinations. Besides, shielding requirements have been evaluated converting the scattered air kerma from mGy/week to mSv/week adopting initially a conversion coefficient from air kerma to effective dose as 1 Sv/Gy and then a mean conversion coefficient specific for the x-ray beam considered. Results show that the thickest barrier should be provided for Mo/Mo target/filter combination. They also point out that the use of the conversion coefficient from air kerma to effective dose as 1 Sv/Gy is conservatively high in the mammography energy range and overestimate the barrier thickness. (c) 2008 American Association of Physicists in Medicine.
Resumo:
In this work, the effect of gamma radiation on the optical properties of polymetallayne poly[1,1'-bis(ethynyl)-4,4'-biphenyl(bis-tributylphosphine)Pt(II) ] (Pt-DEBP) in chloroform solution is studied. The samples were irradiated at room temperature with doses from 0.01 Gy to 1 Gy using a 60Co gamma ray source. A new band at 420 nm is observed in the emission spectra, in superposition to the emission maximum at 398 nm, linearly dependent on dose. We propose to use the ratio of the emission amplitude bands as the dosimetric parameter. This method proved to be robust, accurate, and can be used as a dosimeter in medical applications. © 2013 AIP Publishing LLC.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public