892 resultados para COLONIZACIÓN - MALVINAS (ISLAS) - 1982-2012
Resumo:
We present initial results from observations and numerical analyses aimed at characterizing the main-belt comet P/2012 T1 (PANSTARRS). Optical monitoring observations were made between 2012 October and 2013 February using the University of Hawaii 2.2 m telescope, the Keck I telescope, the Baade and Clay Magellan telescopes, Faulkes Telescope South, the Perkins Telescope at Lowell Observatory, and the Southern Astrophysical Research Telescope. The object's intrinsic brightness approximately doubles from the time of its discovery in early October until mid-November and then decreases by ~60% between late December and early February, similar to photometric behavior exhibited by several other main-belt comets and unlike that exhibited by disrupted asteroid (596) Scheila. We also used Keck to conduct spectroscopic searches for CN emission as well as absorption at 0.7 μm that could indicate the presence of hydrated minerals, finding an upper limit CN production rate of Q CN <1.5 × 1023 mol s-1, from which we infer a water production rate of Q_H_2O100 Myr and is unlikely to be a recently implanted interloper from the outer solar system, while a search for potential asteroid family associations reveals that it is dynamically linked to the ~155 Myr old Lixiaohua asteroid family. Some of the data presented herein were obtained at the W. M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California, and the National Aeronautics and Space Administration, and made possible by the generous financial support of the W. M. Keck Foundation, the Magellan Telescopes located at Las Campanas Observatory, Chile, and the Southern Astrophysical Research (SOAR) telescope, which is a joint project of the Ministério da Ciência, Tecnologia, e Inovação (MCTI) da República Federativa do Brasil, the U.S. National Optical Astronomy Observatory (NOAO), the University of North Carolina at Chapel Hill (UNC), and Michigan State University (MSU).
Resumo:
We report photometric observations for comet C/2012 S1 (ISON) obtained during the time period immediately after discovery (r = 6.28 AU) until it moved into solar conjunction in mid-2013 June using the UH2.2 m, and Gemini North 8 m telescopes on Mauna Kea, the Lowell 1.8 m in Flagstaff, the Calar Alto 1.2 m telescope in Spain, the VYSOS-5 telescopes on Mauna Loa Hawaii and data from the CARA network. Additional pre-discovery data from the Pan STARRS1 survey extends the light curve back to 2011 September 30 (r = 9.4 AU). The images showed a similar tail morphology due to small micron sized particles throughout 2013. Observations at submillimeter wavelengths using the James Clerk Maxwell Telescope on 15 nights between 2013 March 9 (r = 4.52 AU) and June 16 (r = 3.35 AU) were used to search for CO and HCN rotation lines. No gas was detected, with upper limits for CO ranging between 3.5-4.5 × 1027 molecules s-1. Combined with published water production rate estimates we have generated ice sublimation models consistent with the photometric light curve. The inbound light curve is likely controlled by sublimation of CO2. At these distances water is not a strong contributor to the outgassing. We also infer that there was a long slow outburst of activity beginning in late 2011 peaking in mid-2013 January (r ~ 5 AU) at which point the activity decreased again through 2013 June. We suggest that this outburst was driven by CO injecting large water ice grains into the coma. Observations as the comet came out of solar conjunction seem to confirm our models.
Resumo:
A long poem in ottava rima, based on Byron's Don Juan, concerning the Eurocrisis and the social consequences of an economic policy of austerity, particularly as it has impacted on Greece.
Resumo:
No Abstract available
Resumo:
This chapter presents an analysis of the unprecedented use of electronic voting by expatriates during the French 2012 legislative elections, when they elected their own representatives (referred to here as ‘deputies’), to the National Assembly in Paris for the first time, in 11 newly created overseas constituencies.
The study is presented within the broader perspective of electronic voting in France more generally, and in the historical context of extra-territorial voting by French expatriates. The authors discuss the main issues and controversies that arose during the 2012 elections, and in a final section analyse the results. The authors conclude by drawing attention to recent developments in electronic voting in France since the 2012 elections, which suggest that although there was much criticism expressed by experts of electronic voting as to the security and transparency of the system used, the official discourse that acclaimed the experience as a success, appears to have convinced its target audience.
Resumo:
Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.