914 resultados para CMMS vs. SCADA
Resumo:
AIMS The preferred antithrombotic strategy for secondary prevention in patients with cryptogenic stroke (CS) and patent foramen ovale (PFO) is unknown. We pooled multiple observational studies and used propensity score-based methods to estimate the comparative effectiveness of oral anticoagulation (OAC) compared with antiplatelet therapy (APT). METHODS AND RESULTS Individual participant data from 12 databases of medically treated patients with CS and PFO were analysed with Cox regression models, to estimate database-specific hazard ratios (HRs) comparing OAC with APT, for both the primary composite outcome [recurrent stroke, transient ischaemic attack (TIA), or death] and stroke alone. Propensity scores were applied via inverse probability of treatment weighting to control for confounding. We synthesized database-specific HRs using random-effects meta-analysis models. This analysis included 2385 (OAC = 804 and APT = 1581) patients with 227 composite endpoints (stroke/TIA/death). The difference between OAC and APT was not statistically significant for the primary composite outcome [adjusted HR = 0.76, 95% confidence interval (CI) 0.52-1.12] or for the secondary outcome of stroke alone (adjusted HR = 0.75, 95% CI 0.44-1.27). Results were consistent in analyses applying alternative weighting schemes, with the exception that OAC had a statistically significant beneficial effect on the composite outcome in analyses standardized to the patient population who actually received APT (adjusted HR = 0.64, 95% CI 0.42-0.99). Subgroup analyses did not detect statistically significant heterogeneity of treatment effects across clinically important patient groups. CONCLUSION We did not find a statistically significant difference comparing OAC with APT; our results justify randomized trials comparing different antithrombotic approaches in these patients.
Resumo:
Transcatheter mitral interventions has been developed to address an unmet clinical need and may be an alternative therapeutic option to surgery with the intent to provide symptomatic and prognostic benefit. Beyond MitraClip therapy, alternative repair technologies are being developed to expand the transcatheter intervention armamentarium. Recently, the feasibility of transcatheter mitral valve implantation in native non-calcified valves has been reported in very high-risk patients. Acknowledging the lack of scientific evidence to date, it is difficult to predict what the ultimate future role of transcatheter mitral valve interventions will be. The purpose of the present report is to review the current state-of-the-art of mitral valve intervention, and to identify the potential future scenarios, which might benefit most from the transcatheter repair and replacement devices under development.
Resumo:
BACKGROUND Inferolateral early repolarization (ER) is highly prevalent and is associated with idiopathic ventricular fibrillation (VF). OBJECTIVE The purpose of this study was to evaluate the potential role of T-wave parameters to differentiate between malignant and benign ER. METHODS We compared the ECGs of patients with ER and VF (n = 92) with control subjects with asymptomatic ER (n = 247). We assessed J-wave amplitude, QTc interval, T-wave/R-wave (T/R) ratio in leads II and V5, and presence of low-amplitude T waves (T-wave amplitude <0.1 mV and <10% of R-wave amplitude in lead I, II, or V4-V6). RESULTS Compared to controls, the VF group had longer QTc intervals (388 ms vs 377 ms, P = .001), higher J-wave amplitudes (0.23 mV vs 0.17 mV, P <.001), higher prevalence of low-amplitude T waves (29% vs 3%, P <.001), and lower T/R ratio (0.18 vs 0.30, P <.001). Logistic regression analysis demonstrated that QTc interval (odds ratio [OR] per 10 ms: 1.15, 95% confidence interval [CI} 1.02-1.30), maximal J-wave amplitude (OR per 0.1 mV: 1.68, 95% CI 1.23-2.31), lower T/R ratio (OR per 0.1 unit: 0.62, 95% CI 0.47-0.81), presence of low-amplitude T waves (OR 3.53, 95% CI 1.26-9.88). and presence of J waves in the inferior leads (OR 2.58, 95% CI 1.18-5.65) were associated with malignant ER. CONCLUSION Patients with malignant ER have a higher prevalence of low-amplitude T waves, lower T/R ratio (lead II or V5), and longer QTc interval. The combination of these parameters with J-wave amplitude and distribution of J waves may allow for improved identification of malignant ER.
Resumo:
OBJECTIVES The aim of this prospective cohort trial was to perform a cost/time analysis for implant-supported single-unit reconstructions in the digital workflow compared to the conventional pathway. MATERIALS AND METHODS A total of 20 patients were included for rehabilitation with 2 × 20 implant crowns in a crossover study design and treated consecutively each with customized titanium abutments plus CAD/CAM-zirconia-suprastructures (test: digital) and with standardized titanium abutments plus PFM-crowns (control conventional). Starting with prosthetic treatment, analysis was estimated for clinical and laboratory work steps including measure of costs in Swiss Francs (CHF), productivity rates and cost minimization for first-line therapy. Statistical calculations were performed with Wilcoxon signed-rank test. RESULTS Both protocols worked successfully for all test and control reconstructions. Direct treatment costs were significantly lower for the digital workflow 1815.35 CHF compared to the conventional pathway 2119.65 CHF [P = 0.0004]. For subprocess evaluation, total laboratory costs were calculated as 941.95 CHF for the test group and 1245.65 CHF for the control group, respectively [P = 0.003]. The clinical dental productivity rate amounted to 29.64 CHF/min (digital) and 24.37 CHF/min (conventional) [P = 0.002]. Overall, cost minimization analysis exhibited an 18% cost reduction within the digital process. CONCLUSION The digital workflow was more efficient than the established conventional pathway for implant-supported crowns in this investigation.
Resumo:
OBJECTIVE To compare the precision of fit of long-span vs. short-span implant-supported screw-retained fixed dental prostheses (FDPs) made from computer-aided-design/computer-aided-manufactured (CAD/CAM) titanium and veneered with ceramic. The null hypothesis was that there is no difference in the vertical microgap between long-span and short-span FDPs. MATERIALS AND METHODS CAD/CAM titanium frameworks for an implant-supported maxillary FDP on implants with a flat platform were fabricated on one single master cast. Group A consisted of six 10-unit FDPs connected to six implants (FDI positions 15, 13, 11, 21, 23, 25) and group B of six 5-unit FDPs (three implants, FDI positions 21, 23, 25). The CAD/CAM system from Biodenta Swiss AG (Berneck, Switzerland) was used for digitizing (laser scanner) the master cast and anatomical CAD of each framework separately. The frameworks were milled (CAM) from a titanium grade V monobloc and veneered with porcelain. Median vertical distance between implant and FDP platforms from the non-tightened implants (one-screw test on implant 25) was calculated from mesial, buccal, and distal scanning electron microscope measurements. RESULTS All measurements showed values <40 μm. Total median vertical microgaps were 23 μm (range 2-38 μm) for group A and 7 μm (4-24 μm) for group B. The difference between the groups was statistically significant at implant 21 (P = 0.002; 97.5% CI -27.3 to -4.9) and insignificant at implant 23 (P = 0.093; -3.9 to 1.0). CONCLUSIONS CAD/CAM fabrication including laboratory scanning and porcelain firing was highly precise and reproducible for all long- and short-span FDPs. While all FDPs showed clinically acceptable values, the short-span FDPs were statistically more precise at the 5-unit span distance.
Adherence to treatment with non-vitamin K antagonist anticoagulants: once- vs. twice-daily regimens.
Resumo:
Chironomid-temperature inference models based on North American, European and combined surface sediment training sets were compared to assess the overall reliability of their predictions. Between 67 and 76 of the major chironomid taxa in each data set showed a unimodal response to July temperature, whereas between 5 and 22 of the common taxa showed a sigmoidal response. July temperature optima were highly correlated among the training sets, but the correlations for other taxon parameters such as tolerances and weighted averaging partial least squares (WA-PLS) and partial least squares (PLS) regression coefficients were much weaker. PLS, weighted averaging, WA-PLS, and the Modern Analogue Technique, all provided useful and reliable temperature inferences. Although jack-knifed error statistics suggested that two-component WA-PLS models had the highest predictive power, intercontinental tests suggested that other inference models performed better. The various models were able to provide good July temperature inferences, even where neither good nor close modern analogues for the fossil chironomid assemblages existed. When the models were applied to fossil Lateglacial assemblages from North America and Europe, the inferred rates and magnitude of July temperature changes varied among models. All models, however, revealed similar patterns of Lateglacial temperature change. Depending on the model used, the inferred Younger Dryas July temperature decrease ranged between 2.5 and 6°C.
Resumo:
A Payment Cost Minimization (PCM) auction has been proposed as an alternative to the Offer Cost Minimization (OCM) auction to be used in wholesale electric power markets with the intention to lower the procurement cost of electricity. Efficiency concerns about this proposal have relied on the assumption of true production cost revelation. Using an experimental approach, I compare the two auctions, strictly controlling for the level of unilateral market power. A specific feature of these complex-offer auctions is that the sellers submit not only the quantities and the minimum prices at which they are willing to sell, but also the start-up fees that are designed to reimburse the fixed start-up costs of the generation plants. I find that both auctions result in start-up fees that are significantly higher than the start-up costs. Overall, the two auctions perform similarly in terms of procurement cost and efficiency. Surprisingly, I do not find a substantial difference between less market power and more market power designs. Both designs result in similar inefficiencies and equally higher procurement costs over the competitive prediction. The PCM auction tends to have lower price volatility than the OCM auction when the market power is minimal but this property vanishes in the designs with market power. These findings lead me to conclude that both the PCM and the OCM auctions do not belong to the class of truth revealing mechanisms and do not easily elicit competitive behavior.
Resumo:
Tiebout's (1956) model of fiscal competition suggests income sorting between jurisdictions while the Alonso (1964), Mills (167) and Muth (1969) model of the monocentric city suggests income sorting over space. However, strict income sorting is not empirically observed. We add fiscal competition to the spatial model by considering a circular inner city surrounded by a suburb. The fiscal difference between the jurisdictions and the commuting advantage of locations closer to the city center are capitalized into house prices. In addition to the traditional equilibrium with income sorting, there are equilibria with income mixing - both across jurisdictions and across space.
Resumo:
Our paper asks the question: Does mode of instruction format (live or online format) effect test scores in the principles of macroeconomics classes? Our data are from several sections of principles of macroeconomics, some in live format, some in online format, and all taught by the same instructor. We find that test scores for the online format, when corrected for sample selection bias, are four points higher than for the live format, and the difference is statistically significant. One possible explanation for this is that there was slightly higher human capital in the classes that had the online format. A Oaxaca decomposition of this difference in grades was conducted to see how much was due to human capital and how much was due to the differences in the rates of return to human capital. This analysis reveals that 25% of the difference was due to the higher human capital with the remaining 75% due to differences in the returns to human capital. It is possible that for the relatively older student with the appropriate online learning skill set, and with schedule constrains created by family and job, the online format provides them with a more productive learning environment than does the alternative traditional live class format. Also, because our data are limited to the student s academic transcript, we recommend future research include data on learning style characteristics, and the constraints formed by family and job choices.
Resumo:
This study of the wholesale electricity market compares the efficiency performance of the auction mechanism currently in place in U.S. markets with the performance of a proposed mechanism. The analysis highlights the importance of considering strategic behavior when comparing different institutional systems. We find that in concentrated markets, neither auction mechanism can guarantee an efficient allocation. The advantage of the current mechanism increases with increased price competition if market demand is perfectly inelastic. However, if market demand has some responsiveness to price, the superiority of the current auction with respect to efficiency is not that obvious. We present a case where the proposed auction outperforms the current mechanism on efficiency even if all offers reflect true production costs. We also find that a market designer might face a choice problem with a tradeoff between lower electricity cost and production efficiency. Some implications for social welfare are discussed as well.
Resumo:
In my recent experimental research of wholesale electricity auctions, I discovered that the complex structure of the offers leaves a lot of room for strategic behavior, which consequently leads to anti- competitive and inefficient outcomes in the market. A specific feature of these complex-offer auctions is that the sellers submit not only the quantities and the minimum prices at which they are willing to sell, but also the start-up fees that are designed to reimburse the fixed start-up costs of the generation plants. In this paper, using the experimental method I compare the performance of two complex-offer auctions (COAs) against the performance of a simple-offer auction (SOA), in which the sellers have to recover all their generation costs --- fixed and variable ---through a uniform market-clearing price. I find that the SOA significantly reduces consumer prices and lowers price volatility. It mitigates anti-competitive effects that are present in the COAs and achieves allocative efficiency more quickly.
Resumo:
All previous studies comparing online and face-to-face format for instruction of economics compared courses that were either online or face-to-face format and regressed exam scores on selected student characteristics. This approach is subject to the econometric problems of self-selection omitted unobserved variables. Our study uses two methods to deal with these problems. First we eliminate self-selection bias by using students from a course that uses both instruction formats. Second, we use the exam questions as the unit of observation, and eliminate omitted variable bias by using an indicator variable for each student to capture the effect of differences in unobserved student characteristics on learning outcomes. We report the finding that students had a significantly greater chance of answering a question correctly if it came from a chapter covered online.