915 resultados para CERAMICS PROCESSING
Resumo:
This article reports on a study investigating the relative influence of the first and dominant language on L2 and L3 morpho-lexical processing. A lexical decision task compared the responses to English NV-er compounds (e.g., taxi driver) and non-compounds provided by a group of native speakers and three groups of learners at various levels of English proficiency: L1 Spanish-L2 English sequential bilinguals and two groups of early Spanish-Basque bilinguals with English as their L3. Crucially, the two trilingual groups differed in their first and dominant language (i.e., L1 Spanish-L2 Basque vs. L1 Basque-L2 Spanish). Our materials exploit an (a)symmetry between these languages: while Basque and English pattern together in the basic structure of (productive) NV-er compounds, Spanish presents a construction that differs in directionality as well as inflection of the verbal element (V[3SG] + N). Results show between and within group differences in accuracy and response times that may be ascribable to two factors besides proficiency: the number of languages spoken by a given participant and their dominant language. An examination of response bias reveals an influence of the participants' first and dominant language on the processing of NV-er compounds. Our data suggest that morphological information in the nonnative lexicon may extend beyond morphemic structure and that, similarly to bilingualism, there are costs to sequential multilingualism in lexical retrieval.
Resumo:
The present study examines the processing of subject-verb (SV) number agreement with coordinate subjects in pre-verbal and post-verbal positions in Greek. Greek is a language with morphological number marked on nominal and verbal elements. Coordinate SV agreement, however, is special in Greek as it is sensitive to the coordinate subject's position: when pre-verbal, the verb is marked for plural while when post-verbal the verb can be in the singular. We conducted two experiments, an acceptability judgment task with adult monolinguals as a pre-study (Experiment 1) and a self-paced reading task as the main study (Experiment 2) in order to obtain acceptance as well as processing data. Forty adult monolingual speakers of Greek participated in Experiment 1 and a hundred and forty one in Experiment 2. Seventy one children participated in Experiment 2: 30 Albanian-Greek sequential bilingual children and 41 Greek monolingual children aged 10–12 years. The adult data in Experiment 1 establish the difference in acceptability between singular VPs in SV and VS constructions reaffirming our hypothesis. Meanwhile, the adult data in Experiment 2 show that plural verbs accelerate processing regardless of subject position. The child online data show that sequential bilingual children have longer reading times (RTs) compared to the age-matched monolingual control group. However, both child groups follow a similar processing pattern in both pre-verbal and post-verbal constructions showing longer RTs immediately after a singular verb when the subject was pre-verbal indicating a grammaticality effect. In the post-verbal coordinate subject sentences, both child groups showed longer RTs on the first subject following the plural verb due to the temporary number mismatch between the verb and the first subject. This effect was resolved in monolingual children but was still present at the end of the sentence for bilingual children indicating difficulties to reanalyze and integrate information. Taken together, these findings demonstrate that (a) 10–12 year-old sequential bilingual children are sensitive to number agreement in SV coordinate constructions parsing sentences in the same way as monolingual children even though their vocabulary abilities are lower than that of age-matched monolingual peers and (b) bilinguals are slower in processing overall.
Resumo:
Modified fluorcanasite glasses were fabricated by either altering the molar ratios of Na(2)O and CaO or by adding P(2)O(5) to the parent stoichiometric glass compositions. Glasses were converted to glass-ceramics by a controlled two-stage heat treatment process. Rods (2 mm x 4 mm) were produced using the conventional lost-wax casting technique. Osteoconductive 45S5 bioglass was used as a reference material. Biocompatibility and osteoconductivity were investigated by implantation into healing defects (2 mm) in the midshaft of rabbit femora. Tissue response was investigated using conventional histology and scanning electron microscopy. Histological and histomorphometric evaluation of specimens after 12 weeks implantation showed significantly more bone contact with the surface of 45S5 bioglass implants when compared with other test materials. When the bone contact for each material was compared between experimental time points, the Glass-Ceramic 2 (CaO rich) group showed significant difference (p = 0.027) at 4 weeks, but no direct contact at 12 weeks. Histology and backscattered electron photomicrographs showed that modified fluorcanasite glass-ceramic implants had greater osteoconductivity than the parent stoichiometric composition. Of the new materials, fluorcanasite glass-ceramic implants modified by the addition of P(2)O(5) showed the greatest stimulation of new mineralized bone tissue formation adjacent to the implants after 4 and 12 weeks implantation. (C) 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 94A: 760-768, 2010
Resumo:
The purpose of this study was to evaluate ex vivo the accuracy an electronic apex locator during root canal length determination in primary molars. Methods: One calibrated examiner determined the root canal length in 15 primary molars (total=34 root canals) with different stages of root resorption. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using an electronic apex locator (Digital Signal Processing). Data were analyzed statistically using the intraclass correlation (ICC) test. Results: Comparing the actual and electronic root canal length measurements in the primary teeth showed a high correlation (ICC=0.95) Conclusions: The Digital Signal Processing apex locator is useful and accurate for apex foramen location during root canal length measurement in primary molars. (Pediatr Dent 200937:320-2) Received April 75, 2008 vertical bar Lost Revision August 21, 2008 vertical bar Revision Accepted August 22, 2008
Resumo:
The purpose of this study was to evaluate the accuracy of electronic apex locators Digital Signal Processing (DSP) and ProPex, for root canal length determination in primary teeth. Fifteen primary molars (a total of 34 root canals) were divided into two groups: Group I - without physiological resorption (n = 16); and Group II - with physiological resorption (n = 18). The length of each canal was measured by introducing a file until its tip was visible and then it was retracted 1 mm. For electronic measurement, the devices were set to 1 mm short of the apical resorption. The data were analysed statistically using the intraclass correlation coefficient (ICC). Results showed that the ICC was high for both electronic apex locators in all situations - with (ICC: DSP = 0.82 and Propex = 0.89) or without resorption (ICC: DSP = 0.92 and Propex = 0.90). Both apex locators were extremely accurate in determining the working length in primary teeth, both with or without physiological resorption.
Resumo:
Statement of problem. Color stability is an important factor to ensure the long-term clinical success of ceramic restorations. There is a lack of information on how color is affected by fabrication procedures, such as the number of firings. Purpose. The purpose of this study was to evaluate the effects that the number of firings and type of substrate have on the color stability of dental ceramic submitted to artificial accelerated aging. Material and methods. Sixty specimens were fabricated: 30 metal ceramic (Verabond II + IPS d.SIGN) and 30 all-ceramic (IPS d.SIGN). Specimens were divided into 3 groups (n=10), and submitted to 2, 3, or 4 firings (+/- 900 degrees C), respectively, according to the manufacturer`s instructions. Color readings were obtained with a spectro photometer before and after artificial accelerated aging, and L*, a*, and b* coordinates and total color variation (Delta E) were analyzed (2-way ANOVA, Bonferroni, (alpha=05). Results. For metal ceramic specimens, differences for the L* coordinates were significant (P<.05) only for the group submitted to 3 firings. With respect to the all-ceramic specimens, smaller L* coordinates were obtained for greater a* and b* coordinates, indicating that the greater the number of firings, the darker and more reddish/yellowish the specimen. All Delta E values, for all groups, were below 1.0. All-ceramic specimens submitted to 3 and 4 firings presented Delta E means differing statistically (P<.05) from those of the metal ceramic group. Conclusions. The type of substrate and number of firings affected the color stability of the ceramic material tested. Artificial accelerated aging did not produce perceptible color stability changes (Delta E<1.0). (J Prosthet Dent 2009-101:13-18)
Resumo:
Amaranth has attracted a great deal of interest in recent decades due to its valuable nutritional, functional, and agricultural characteristics. Amaranth seeds can be cooked, popped, roasted, flaked, or extruded for consumption. This study compared the in vitro starch digestibility of processed amaranth seeds to that of white bread. Raw seeds yielded rapidly digestible starch content (RDS) of 30.7% db and predicted glycemic index (pGI) of 87.2, the lowest among the studied products. Cooked, extruded, and popped amaranth seeds had starch digestibility similar to that of white bread (92.4, 91.2, and 101.3, respectively), while flaked and roasted seeds generated a slightly increased glycemic response (106.0 and 105.8, respectively). Cooking and extrusion did not alter the RDS contents of the seeds. No significant differences were observed among popped, flaked, and roasted RDS contents (38.0%,46.3%, and 42.9%, respectively), which were all lower than RDS content of bread (51.1%). Amaranth seed is a high glycemic food most likely because of its small starch granule size, low resistant starch content (< 1%), and tendency to completely lose its crystalline and granular starch structure during those heat treatments.
Resumo:
Effect of processing on the antioxidant activity of amaranth grain. Amaranth has attracted increasing interest over recent decades because of its nutritional, functional and agricultural characteristics. Amaranth grain can be cooked, popped, toasted, extruded or milled for consumption. This study investigated the effect of these processes on the antioxidant activity of amaranth grain. Total phenolic content and in vitro antioxidant activity were determined according to two methods: inhibition, of lipid oxidation using the beta-carotene/linoleic acid system and the antioxidant activity index using the Rancimat (R) apparatus. The processing reduced the mean total phenolics content in amaranth grain from 31.7 to 22.0 mg of gallic acid equivalent/g of dry residue. It was observed that the ethanol extract from toasted grain was the only one that presented a lower antioxidant activity index compared with the raw grain (1.3 versus 1.7). The extrusion, toasting and popping processes did not change the capacity to inhibit amaranth lipid oxidation (55%). However, cooking increased the inhibition of lipid oxidation (79%), perhaps because of the longer time at high temperatures in this process (100 degrees C/10 min). The most common methods for processing amaranth grain caused reductions in the total phenolics content, although the antioxidant activity of popped and extruded grain, evaluated by the two methods, was similar to that of the raw grain. Both raw and processed amaranth grain presents antioxidant potential. Polyphenols, anthocyanins, flavonoids, tocopherols, vitamin C levels and Maillard reaction products may be related to the antioxidant activity of this grain.