974 resultados para Bit Error Rate


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Møller-Plesset (MP2) and Becke-3-Lee-Yang-Parr (B3LYP) calculations have been used to compare the geometrical parameters, hydrogen-bonding properties, vibrational frequencies and relative energies for several X- and X+ hydrogen peroxide complexes. The geometries and interaction energies were corrected for the basis set superposition error (BSSE) in all the complexes (1-5), using the full counterpoise method, yielding small BSSE values for the 6-311 + G(3df,2p) basis set used. The interaction energies calculated ranged from medium to strong hydrogen-bonding systems (1-3) and strong electrostatic interactions (4 and 5). The molecular interactions have been characterized using the atoms in molecules theory (AIM), and by the analysis of the vibrational frequencies. The minima on the BSSE-counterpoise corrected potential-energy surface (PES) have been determined as described by S. Simón, M. Duran, and J. J. Dannenberg, and the results were compared with the uncorrected PES

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparision of the local effects of the basis set superposition error (BSSE) on the electron densities and energy components of three representative H-bonded complexes was carried out. The electron densities were obtained with Hartee-Fock and density functional theory versions of the chemical Hamiltonian approach (CHA) methodology. It was shown that the effects of the BSSE were common for all complexes studied. The electron density difference maps and the chemical energy component analysis (CECA) analysis confirmed that the local effects of the BSSE were different when diffuse functions were present in the calculations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of basis set superposition error (BSSE) on molecular complexes is analyzed. The BSSE causes artificial delocalizations which modify the first order electron density. The mechanism of this effect is assessed for the hydrogen fluoride dimer with several basis sets. The BSSE-corrected first-order electron density is obtained using the chemical Hamiltonian approach versions of the Roothaan and Kohn-Sham equations. The corrected densities are compared to uncorrected densities based on the charge density critical points. Contour difference maps between BSSE-corrected and uncorrected densities on the molecular plane are also plotted to gain insight into the effects of BSSE correction on the electron density

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The basis set superposition error-free second-order MØller-Plesset perturbation theory of intermolecular interactions was studied. The difficulties of the counterpoise (CP) correction in open-shell systems were also discussed. The calculations were performed by a program which was used for testing the new variants of the theory. It was shown that the CP correction for the diabatic surfaces should be preferred to the adiabatic ones

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Geometries, vibrational frequencies, and interaction energies of the CNH⋯O3 and HCCH⋯O3 complexes are calculated in a counterpoise-corrected (CP-corrected) potential-energy surface (PES) that corrects for the basis set superposition error (BSSE). Ab initio calculations are performed at the Hartree-Fock (HF) and second-order Møller-Plesset (MP2) levels, using the 6-31G(d,p) and D95++(d,p) basis sets. Interaction energies are presented including corrections for zero-point vibrational energy (ZPVE) and thermal correction to enthalpy at 298 K. The CP-corrected and conventional PES are compared; the unconnected PES obtained using the larger basis set including diffuse functions exhibits a double well shape, whereas use of the 6-31G(d,p) basis set leads to a flat single-well profile. The CP-corrected PES has always a multiple-well shape. In particular, it is shown that the CP-corrected PES using the smaller basis set is qualitatively analogous to that obtained with the larger basis sets, so the CP method becomes useful to correctly describe large systems, where the use of small basis sets may be necessary

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a simple method to automate the geometric optimization of molecular orbital calculations of supermolecules on potential surfaces that are corrected for basis set superposition error using the counterpoise (CP) method. This method is applied to the H-bonding complexes HF/HCN, HF/H2O, and HCCH/H2O using the 6-31G(d,p) and D95 + + (d,p) basis sets at both the Hartree-Fock and second-order Møller-Plesset levels. We report the interaction energies, geometries, and vibrational frequencies of these complexes on the CP-optimized surfaces; and compare them with similar values calculated using traditional methods, including the (more traditional) single point CP correction. Upon optimization on the CP-corrected surface, the interaction energies become more negative (before vibrational corrections) and the H-bonding stretching vibrations decrease in all cases. The extent of the effects vary from extremely small to quite large depending on the complex and the calculational method. The relative magnitudes of the vibrational corrections cannot be predicted from the H-bond stretching frequencies alone

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, the surprising result that ab initio calculations on benzene and other planar arenes at correlated MP2, MP3, configuration interaction with singles and doubles (CISD), and coupled cluster with singles and doubles levels of theory using standard Pople’s basis sets yield nonplanar minima has been reported. The planar optimized structures turn out to be transition states presenting one or more large imaginary frequencies, whereas single-determinant-based methods lead to the expected planar minima and no imaginary frequencies. It has been suggested that such anomalous behavior can be originated by two-electron basis set incompleteness error. In this work, we show that the reported pitfalls can be interpreted in terms of intramolecular basis set superposition error (BSSE) effects, mostly between the C–H moieties constituting the arenes. We have carried out counterpoise-corrected optimizations and frequency calculations at the Hartree–Fock, B3LYP, MP2, and CISD levels of theory with several basis sets for a number of arenes. In all cases, correcting for intramolecular BSSE fixes the anomalous behavior of the correlated methods, whereas no significant differences are observed in the single-determinant case. Consequently, all systems studied are planar at all levels of theory. The effect of different intramolecular fragment definitions and the particular case of charged species, namely, cyclopentadienyl and indenyl anions, respectively, are also discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: On September 11, 2001, terrorists attacked the United States. By coincidence, a North Carolina highway patrol trooper was wearing an ambulatory ECG Holter monitor at this time as part of an air pollution study. METHODS: Heart rate variability parameters were analyzed: standard deviation of normal to normal beat intervals (SDNN) and percentage of interval differences >50 ms (PNN50). RESULTS: The trooper's heart rate variability changed immediately after learning about the terrorist attacks. Heart rate increased and PNN50 decreased, while SDNN increased strongly. CONCLUSIONS: These changes suggest strong emotional sympathetic stress associated with parasympathetic withdrawal in response to the news about the terrorist attack. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postabsorptive resting metabolic rate (RMR), measured by indirect calorimetry, and the effect of iv propranolol administration were studied in 12 nonseptic patients with severe head injury by means of indirect calorimetry. Before propranolol RMR was moderately increased (126 +/- 10.4% of predicted values) whereas urinary excretion of catecholamines was markedly elevated (p less than .01 vs. normal values). RMR was significantly correlated with both resting heart rate (HR) (r = .72, p less than .01) and 24-h urinary N excretion (r = .85, p less than .001). The administration of iv propranolol (0.1 mg/kg) produced a rapid decrease in HR (-10 +/- 4%, p less than .001) and in RMR (-6.1 +/- 2.3%, p less than .001). Further administration of propranolol produced no additional reduction in either HR or RMR. We conclude that severely head-injured patients are moderately hypermetabolic in resting and postabsorptive conditions, and that acute iv propranolol administration induces a reduction of about one quarter of the resting hypermetabolism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the effects of the financial crisis on the stationarity of real interest rates in the Euro Area. We use a new unit root test developed by Peseran et al. (2013) that allows for multiple unobserved factors in a panel set up. Our results suggest that while short-term and long-term real interest rates were stationary before the financial crisis, they became nonstationary during the crisis period likely due to persistent risk that characterized financial markets during that time. JEL codes: E43, C23. Keywords: Real interest rates, Euro Area, financial crisis, panel unit root tests, cross-sectional dependence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The role of video-assisted thoracoscopic surgery in the treatment of pleural empyema was assessed in a consecutive series of 328 patients between 1992 and 2002. An analysis of the predicting factors for conversion thoracotomy in presumed stage II empyema was performed. METHODS: Empyema stage III with pleural thickening and signs of restriction on computer tomography imaging was treated by open decortication, whereas a thoracoscopic debridement was attempted in presumed stage II disease. Conversion thoracotomy was liberally used during thoracoscopy if stage III disease was found at surgery. Predictive factors for conversion thoracotomy were calculated in a multivariate analysis among several variables such as age, sex, time interval between onset of symptoms and surgery, involved microorganisms, and underlying cause of empyema. RESULTS: Of the 328 patients surgically treated for stage II and III empyema, 150 underwent primary open decortication for presumed stage III disease. One hundred seventy-eight patients with presumed stage II empyema underwent a video-assisted thoracoscopic approach. Of these 178 patients, thoracoscopic debridement was successful in 99 of 178 patients (56%), and conversion thoracotomy and open decortication was judged necessary in 79 of 178 patients (44%). The conversion thoracotomy rate was higher in parapneumonic empyema (55%) as compared with posttraumatic (32%) or postoperative (29%) empyema; however, delayed referral (p < 0.0001) and gram-negative microorganisms (p < 0.01) were the only significant predictors for conversion thoracotomy in a multivariate analysis. CONCLUSIONS: Video-assisted thoracoscopic debridement offers an elegant, minimally invasive approach in a number of patients with presumed stage II empyema. However, to achieve a high success rate with the video-assisted thoracoscopic approach, early referral of the patients to surgery is required. Conversion thoracotomy should be liberally used in case of chronicity, especially after delayed referral (> 2 weeks) and in the presence of gram-negative organisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Confronting a recently mated female with a strange male can induce a pregnancy block ('Bruce effect'). The physiology of this effect is well studied, but its functional significance is still not fully understood. The 'anticipated infanticide hypothesis' suggests that the pregnancy block serves to avoid the cost of embryogenesis and giving birth to offspring that are likely to be killed by a new territory holder. Some 'compatible-genes sexual selection hypotheses' suggest that the likelihood of a pregnancy block is also dependent on the female's perception of the stud's and the stimulus male's genetic quality. We used two inbred strains of mice (C57BL/6 and BALB/c) to test all possible combinations of female strain, stud strain, and stimulus strain under experimental conditions (N(total) = 241 mated females). As predicted from previous studies, we found increased rates of pregnancy blocks if stud and stimulus strains differed, and we found evidence for hybrid vigour in offspring of between-strain mating. Despite the observed heterosis, pregnancies of within-strain matings were not more likely to be blocked than pregnancies of between-strain matings. A power analysis revealed that if we missed an existing effect (type-II error), the effect must be very small. If a female gave birth, the number and weight of newborns were not significantly influenced by the stimulus males. In conclusion, we found no support for the 'compatible-genes sexual selection hypotheses'.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The aim of this report is to describe the main characteristics of the design, including response rates, of the Cornella Health Interview Survey Follow-up Study. Methods: The original cohort consisted of 2,500 subjects (1,263 women and 1,237 men) interviewed as part of the 1994 Cornella Health Interview Study. A record linkage to update the address and vital status of the cohort members was carried out using, first a deterministic method, and secondly a probabilistic one, based on each subject's first name and surnames. Subsequently, we attempted to locate the cohort members to conduct the phone follow-up interviews. A pilot study was carried out to test the overall feasibility and to modify some procedures before the field work began. Results: After record linkage, 2,468 (98.7%) subjects were successfully traced. Of these, 91 (3.6%) were deceased, 259 (10.3%) had moved to other towns, and 50 (2.0%) had neither renewed their last municipal census documents nor declared having moved. After using different strategies to track and to retain cohort members, we traced 92% of the CHIS participants. From them, 1,605 subjects answered the follow-up questionnaire. Conclusion: The computerized record linkage maximized the success of the follow-up that was carried out 7 years after the baseline interview. The pilot study was useful to increase the efficiency in tracing and interviewing the respondents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The simultaneous use of multiple transmit and receive antennas can unleash very large capacity increases in rich multipath environments. Although such capacities can be approached by layered multi-antenna architectures with per-antenna rate control, the need for short-term feedback arises as a potential impediment, in particular as the number of antennas—and thus the number of rates to be controlled—increases. What we show, however, is that the need for short-term feedback in fact vanishes as the number of antennas and/or the diversity order increases. Specifically, the rate supported by each transmit antenna becomes deterministic and a sole function of the signal-to-noise, the ratio of transmit and receive antennas, and the decoding order, all of which are either fixed or slowly varying. More generally, we illustrate -through this specific derivation— the relevance of some established random CDMA results to the single-user multi-antenna problem.