913 resultados para Biomedical optics


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye aft er the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients aft er bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group (P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group (P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil (P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To study the oculometric parameters of hyperopia in children with esotropic amblyopia, comparing amblyopic eyes with fellow eyes. Methods: Thirty-seven patients (5-8 years old) with bilateral hyperopia and esotropic amblyopia underwent a comprehensive ophthalmic examination, including cycloplegic refraction, keratometry and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. The refractive power of the crystalline lens was calculated using Bennett`s equations. Paired Student`s t-tests were used to compare ocular biometric measurements between amblyopic eyes and their fellow eyes. The associations of biometric parameters with refractive errors were assessed using Pearson correlation coefficients and linear regression. Multivariable models including axial length, corneal power and lens power were also constructed. Results: Amblyopic eyes were found to have significantly more hyperopic refraction, less corneal power, greater lens power, shorter vitreous chamber depth and shorter axial length, despite similar anterior chamber depth and lens thickness. The strongest correlation with refractive error was observed for the axial length/corneal radius ratio (r(36) = -0.92, p < 0.001 for amblyopic and r(36) = 0.87, p < 0.001 for fellow eyes). Axial length accounted for 39.2% (R(2)) of the refractive error variance in amblyopic eyes and 35.5% in fellow eyes. Adding corneal power to the model increased R(2) to 85.7% and 79.6%, respectively. A statistically significant correlation was found between axial length and corneal power, indicating decreasing corneal power with increasing axial length, and they were similar for amblyopic eyes (r(36) = 0.53,p < 0.001) and fellow eyes (r(36) = -0.57, p < 0.001). A statistically significant correlation was also found between axial length and lens power, indicating decreasing lens power with increasing axial length (r(36) = -0.72, p < 0.001 for amblyopic eyes and r(36) = -0.69, p < 0.001 for fellow eyes). Conclusions: We observed that the correlation among the major oculometric parameters and their individual contribution to hyperopia in esotropic children were similar in amblyopic and non-amblyopic eyes. This finding suggests that the counterbalancing effect of greater corneal and lens power associated with shorter axial length is similar in both eyes of patients with esotropic amblyopia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quantum mechanics has been formulated in phase space, with the Wigner function as the representative of the quantum density operator, and classical mechanics has been formulated in Hilbert space, with the Groenewold operator as the representative of the classical Liouville density function. Semiclassical approximations to the quantum evolution of the Wigner function have been defined, enabling the quantum evolution to be approached from a classical starting point. Now analogous semiquantum approximations to the classical evolution of the Groenewold operator are defined, enabling the classical evolution to be approached from a quantum starting point. Simple nonlinear systems with one degree of freedom are considered, whose Hamiltonians are polynomials in the Hamiltonian of the simple harmonic oscillator. The behavior of expectation values of simple observables and of eigenvalues of the Groenewold operator are calculated numerically and compared for the various semiclassical and semiquantum approximations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concept of entanglement in systems where the particles are indistinguishable has been the subject of much recent interest and controversy. In this paper we study the notion of entanglement of particles introduced by Wiseman and Vaccaro [Phys. Rev. Lett. 91, 097902 (2003)] in several specific physical systems, including some that occur in condensed-matter physics. The entanglement of particles is relevant when the identical particles are itinerant and so not distinguished by their position as in spin models. We show that entanglement of particles can behave differently than other approaches that have been used previously, such as entanglement of modes (occupation-number entanglement) and the entanglement in the two-spin reduced density matrix. We argue that the entanglement of particles is what could actually be measured in most experimental scenarios and thus its physical significance is clear. This suggests that entanglement of particles may be useful in connecting theoretical and experimental studies of entanglement in condensed-matter systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrical impedance tomography is a technique to estimate the impedance distribution within a domain, based on measurements on its boundary. In other words, given the mathematical model of the domain, its geometry and boundary conditions, a nonlinear inverse problem of estimating the electric impedance distribution can be solved. Several impedance estimation algorithms have been proposed to solve this problem. In this paper, we present a three-dimensional algorithm, based on the topology optimization method, as an alternative. A sequence of linear programming problems, allowing for constraints, is solved utilizing this method. In each iteration, the finite element method provides the electric potential field within the model of the domain. An electrode model is also proposed (thus, increasing the accuracy of the finite element results). The algorithm is tested using numerically simulated data and also experimental data, and absolute resistivity values are obtained. These results, corresponding to phantoms with two different conductive materials, exhibit relatively well-defined boundaries between them, and show that this is a practical and potentially useful technique to be applied to monitor lung aeration, including the possibility of imaging a pneumothorax.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Guinea pigs were exposed to pure tones of 10 kHz at intensities between 98 and 115 dB SPL for 5-30 min, to produce varying degrees of acoustic trauma. Changes in auditory thresholds were measured electrophysiologically, and the animals were immediately fixed for scanning electron microscopy. Correlation between morphological changes to the hair bundle and losses in threshold, showed that with the smallest degrees of trauma (98 dB SPL for 15 min, mean maximum threshold loss of 22 dB), damage was confined to a small stretch of inner hair cells (IHC), with only subtle changes to the stereocilia of the outer hair cells (OHC). At exposure intensities greater than 102 dB SPL (duration: 15 min) the IHC stereocilia in the centre of the lesion were always substantially disarrayed. Substantial damage to the OHC bundles was seen only with exposures above 110 dB SPL(duration: greater than or equal to 5 min), producing threshold losses of 50 dB or more. Tip links were lost only where the stereocilia were disarrayed. It is concluded that the tip links are not the most vulnerable components of the cochlear hair cell, but that relatively low levels of acoustic stimulation can cause significant damage to the stereociliary bundle of the IHCs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to investigate bone responses to a novel bioactive fully crystallized glass-ceramic of the quaternary system P(2)O(5)-Na(2)O-CaO-SiO(2) (Biosilicates (R)). Although a previous study demonstrated positive effects of Biosilicate (R) on in vitro bone-like matrix formation, its in vivo effect was not studied yet. Male Wistar rats (n = 40) with tibial defects were used. Four experimental groups were designed to compare this novel biomaterial with a gold standard bioactive material (Bioglass (R) 45S5), unfilled defects and intact controls. A three-point bending test was performed 20 days after the surgical procedure, as well as the histomorphometric analysis in two regions of interest: cortical bone and medullary canal where the particulate biomaterial was implanted. The biomechanical test revealed a significant increase in the maximum load at failure and stiffness in the Biosilicate group (R) (vs. control defects), whose values were similar to uninjured bones. There were no differences in the cortical bone parameters in groups with bone defects, but a great deal of woven bone was present surrounding Biosilicate (R) and Bioglass (R) 45S5 particulate. Although both bioactive materials supported significant higher bone formation; Biosilicate (R) was superior to Bioglass (R) 45S5 in some histomorphometric parameters (bone volume and number of osteoblasts). Regarding bone resorption, Biosilicate (R) group showed significant higher number of osteoclasts per unit of tissue area than defect and intact controls, despite of the non-significant difference in the osteoclastic surface as percentage of bone surface. This study reveals that the fully crystallized Biosilicate (R) has good bone-forming and bone-bonding properties. (C) 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 978: 139-147, 2011.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives This study evaluated the influence of oestrogen deficiency and its therapies on bone tissue around osseointegrated implants. Methods Implants were placed in 66 female rats tibiae. The animals were assigned into five groups: control (CTL), sham, ovariectomy (OVX), oestrogen (EST), and alendronate (ALE). While CTL was sacrificed 60 days after implant placement, other groups were subjected to ovariectomy or sham surgery according to group and euthanized after 90 days. Blood and urine samples were collected at sacrifice day for osteocalcin (OCN) and deoxypyridinoline (DPD) quantification. Densitometry of femur and lumbar vertebrae was performed in order to evaluate rats` skeletal impairment. Non-decalcified sections were referred to fluorescent and light microscopy for analyses of mineral apposition rate (MAR), eroded and osteoclastic surfaces, bone-to-implant contact (BIC), and bone area fraction occupancy (BAFO). Results Results from the OVX group showed significantly lower bone mineral density (BMD), BIC, BAFO, and MAR, while OCN, deoxipiridinoline, eroded surface and ostecoclastic surface were increased compared with the other groups of the study. ALE reduced OCN and DPD concentrations, MAR, osteoclastic and eroded surfaces, and no difference was in BIC and BAFO relative to SHAM. EST and CTL showed similar results to SHAM for measurements. Conclusions Oestrogen deficiency exerted a negative influence on bone tissue around implants, while oestrogen replacement therapy and alendronate were effective against its effects. Although alendronate therapy maintained the quantity of bone around implants, studies evaluating bone turnover kinetics are warranted. To cite this article:Giro G, Coelho PG, Pereira RMR, Jorgetti V, Marcantonio E Jr, Orrico SRP. The effect of oestrogen and alendronate therapies on postmenopausal bone loss around osseointegrated titanium implants.Clin. Oral Impl. Res. 22, 2011; 259-264.doi: 10.1111/j.1600-0501.2010.01989.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A single-beam gradient trap could potentially be used to hold a stylus for scanning force microscopy. With a view to development of this technique, we modeled the optical trap as a harmonic oscillator and therefore characterized it by its force constant. We measured force constants and resonant frequencies for 1-4-mu m-diameter polystyrene spheres in a single-beam gradient trap using measurements of back-scattered light. Force constants were determined with both Gaussian and doughnut laser modes, with powers of 3 and 1 mW, respectively. Typical values for spring constants were measured to be between 10(-6) and 4 x 10(-6) N/m. The resonant frequencies of trapped particles were measured to be between 1 and 10 kHz, and the rms amplitudes of oscillations were estimated to be around 40 nm. Our results confirm that the use of the doughnut mode for single-beam trapping is more efficient in the axial direction. (C) 1996 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Little consensus exists in the literature regarding methods for determination of the onset of electromyographic (EMG) activity. The aim of this study was to compare the relative accuracy of a range of computer-based techniques with respect to EMG onset determined visually by an experienced examiner. Twenty-seven methods were compared which varied in terms of EMG processing (low pass filtering at 10, 50 and 500 Hz), threshold value (1, 2 and 3 SD beyond mean of baseline activity) and the number of samples for which the mean must exceed the defined threshold (20, 50 and 100 ms). Three hundred randomly selected trials of a postural task were evaluated using each technique. The visual determination of EMG onset was found to be highly repeatable between days. Linear regression equations were calculated for the values selected by each computer method which indicated that the onset values selected by the majority of the parameter combinations deviated significantly from the visually derived onset values. Several methods accurately selected the time of onset of EMG activity and are recommended for future use. Copyright (C) 1996 Elsevier Science Ireland Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To test the hypothesis that ruptured abdominal aortic aneurysms (AAA) are globally weaker than unruptured ones. Methods: Four ruptured and seven unruptured AAA specimens were harvested whole from fresh cadavers during autopsies performed over an 18-month period. Multiple regionally distributed longitudinally oriented rectangular strips were cut from each AAA specimen for a total of 77 specimen strips. Strips were subjected to uniaxial extension until failure. Sections from approximately the strongest and weakest specimen strips were studied histologically and histochemically. From the load-extension data, failure tension, failure stress and failure strain were calculated. Rupture site characteristics such as location, arc length of rupture and orientation of rupture were also documented. Results: The failure tension, a measure of the tissue mechanical caliber was remarkably similar between ruptured and unruptured AAA (group mean +/- standard deviation of within-subject means: 11.2 +/- 2.3 versus 11.6 +/- 3.6 N/cin; p=0.866 by mixed model ANOVA). In post-hoc analysis, there was little difference between the groups in other measures of tissue mechanical caliber as well such as failure stress (95 +/- 28 versus 98 +/- 23 N/cm(2); p=0.870), failure strain (0.39 +/- 0.09 versus 0.36 +/- 0.09; p=0.705), wall thickness (1.7 +/- 0.4 versus 1.5 +/- 0.4 mm; p=0.470), and % coverage of collagen within tissue cross section (49.6 +/- 12.9% versus 60.8 +/- 9.6%; p=0.133). In the four ruptured AAA, primary rupture sites were on the lateral quadrants (two on left; one on left-posterior; one on right). Remarkably, all rupture lines had a longitudinal orientation and ranged from 1 to 6 cm in length. Conclusion: The findings are not consistent with the hypothesis that ruptured aortic aneurysms are globally weaker than unruptured ones. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We calculate the stationary state of the system of two non-identical two-level atoms driven by a finite-bandwidth two-mode squeezed vacuum. It is well known that two identical two-level atoms driven by a broadband squeezed vacuum may decay to a pure state, called the pure two-atom squeezed state, and that the presence of the antisymmetric state can change its purity. Here, we show that for small interatomic separations the stationary state of two non-identical atoms is not sensitive to the presence of the antisymmetric state and is the pure two-atom squeezed state. This effect is a consequence of the fact that in the system of two non-identical atoms the antisymmetric state is no longer the trapping state. We also calculate the squeezing properties of the emitted field and find that the squeezing spectrum of the output field may exhibit larger squeezing than that in the input squeezed vacuum. Moreover, we show that squeezing in the total field attains the optimum value which can ever be achieved in the field emitted by two atoms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

No abstract

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sensitive and rapid HPLC assay for determining cefuroxime penetration in the subcutaneous tissue near to surgical incision of patients submitted to coronary artery bypass grafting (CABC) with or without cardiopulmonary bypass (CPB) was performed. Blood and subcutaneous tissue samples were collected from 14 patients. in four periods during surgery. The analytical method presented linearity from 0.5 to 100 mu g/g. LOQ = 0.50 mu g/g, LOD = 0.25 mu g/g. intra- and interday precision (%CV) ranged from 4.9 to 8.9% and 6.4 to 9.9%, respectively, and intra-and interday accuracy expressed as % of the nominal concentration ranged from 87.1 to 104.6% and 94.8 to 103.8%, respectively (mean of three concentrations). Relative recovery was 98.4%. Tissue/plasma ratios obtained for CPB and non-CPB were, respectively: 14.6% vs 19.0% (0.6 h); 15.7% vs 15.7% (2.1 h); 22.5% vs 19.9% (3.6 h); 15.7% vs 18.8% (4.5 h). Data obtained indicate that tissue/plasma ratio remains unchanged in CPB and non-CPB patients during all period of surgery and the CPB does not affect the penetration of cefuroxime in tissues close to the surgical wound. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The squeezing properties of the fluorescence field emitted by a two-level atom driven by a coherent laser field in a squeezed vacuum are calculated. We show that in the region of the anomalous resonance fluorescence the emitted field exhibits squeezing that is much larger than that in the input squeezed vacuum. The squeezing spectrum attains a minimum value that corresponds to 75% squeezing. We also find that, in the total fluorescence field, squeezing attains an optimum achievable value in the fluorescence field emitted by a two-level atom. The optimum squeezing is associated with the collapse of the system into a pure state. (C) 1997 Optical Society of America.