930 resultados para BRONCHOALVEOLAR LAVAGE FLUID
Resumo:
This study evaluated the influence of follicular fluid (FF) added to the maturation medium on the quality of bovine embryos produced in vitro. In the first experiment, oocytes were matured in media containing five different FF concentrations with different maturation times and classified according to meiotic progression and migration of cortical granules. In the second experiment, oocytes matured in the same media were fertilized at three different maturation times; thereafter, cleavage and blastocyst rates were evaluated. In the third experiment, oocytes were matured in media containing three different FF concentrations at two different maturation times, and embryo quality, inferred by the ratio of inner cell mass and trophectoderm cells compared with total cell number, was evaluated. Higher FF concentration (75 - 100% FF) slowed meiotic progression and CG migration (control - 78.13% vs. treated - 52.58% and control - 52.7% vs. treated - 11.59%, respectively, at 24 h of maturation). Also, FF at concentration of 75% or 100% had a negative influence on cleavage and blastocyst rates (control - 90.13% vs. treated - 82.64% and control - 35.73% vs. treated - 11.57%, respectively, at 24 h of maturation). The 50% FF resulted in embryos with increased inner cell mass numbers (control - 29.91 vs. treated - 35.49, at 24 h of maturation) and total cell numbers (control - 109.53 vs. treated - 120.67, at 26 h of maturation). Even though higher concentration of FF added to the maturation medium reduced embryonic development rates, in lower concentrations, FF slowed the meiotic progression and migration of CG and contributed to increases in inner cell mass number. Thus, FF added to the maturation medium enhances the number of cells in bovine embryos produced in vitro, especially for inner cell mass.
Resumo:
Free surface flows in inclined channels can develop periodic instabilities that are propagated downstream as shock waves with well-defined wavelengths and amplitudes. Such disturbances are called roll waves and are common in channels, torrential lava, landslides, and avalanches. The prediction and detection of such waves over certain types of structures and environments are useful for the prevention of natural risks. In this work, a mathematical model is established using a theoretical approach based on Cauchy's equations with the Herschel-Bulkley rheological model inserted into the viscous part of the stress tensor. This arrangement can adequately represent the behavior of muddy fluids, such as water-clay mixture. Then, taking into account the shallow water and the Rankine-Hugoniot's (shock wave) conditions, the equation of the roll wave and its properties, profile, and propagation velocity are determined. A linear stability analysis is performed with an emphasis on determining the condition that allows the generation of such instabilities, which depends on the minimum Froude number. A sensitivity analysis on the numerical parameters is performed, and numerical results including the influence of the Froude number, the index flow and dimensionless yield stress on the amplitude, the wavelength of roll waves and the propagation velocity of roll waves are shown. We show that our numerical results were in agreement with Coussot's experimental results (1994).
Resumo:
This work presents a numerical model to simulate refrigerant flow through capillary tubes, commonly used as expansion devices in refrigeration systems. The flow is divided in a single-phase region, where the refrigerant is in the subcooled liquid state, and a region of two-phase flow. The capillary tube is considered straight and horizontal. The flow is taken as one-dimensional and adiabatic. Steady-state condition is also assumed and the metastable flow phenomena are neglected. The two-fluid model, considering the hydrodynamic and thermal non-equilibrium between the liquid and vapor phases, is applied to the two-phase flow region. Comparisons are made with experimental measurements of the mass flow rate and pressure distribution along two capillary tubes working with refrigerant R-134a in different operating conditions. The results indicate that the present model provides a better estimation than the commonly employed homogeneous model. Some computational results referring to the quality, void fraction, velocities, and temperatures of each phase are presented and discussed.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The steel type AISI 4130 (ultra-high strength steel) is an alloy of low carbon and its main alloying elements are chromium and molybdenum, which improves the toughness of the weld metal. It has numerous applications, especially where the need for high mechanical strength. It is widely used in equipment used by the aviation industry, such as cradle-tomotor, and this is the motivation for this study. Cots are of fundamental importance, because the engine supports and maintains balance in the fixed landing gear. This equipment is subjected to intense loading cycles, whose fractures caused by fatigue are constantly observed. Will be determined the effects caused by re-welding the structure of aeronautical equipment, and will also study the microstructure of the metal without welding. The studies will be done on materials used in aircraft, which was given to study. The results provide knowledge of microstructure to evaluate any type of fracture that maybe caused by fatigue. Fatigue is a major cause of aircraft accidents and incidents occurred, which makes the study of the microstructure of the metal, weld and re-solder the knowledge essential to the life of the material. The prevention and control of the process of fatigue in aircraft are critical, since the components are subjected to greater responsibility cyclic loading
Resumo:
One of the main causes of incapacity in athletes, be they human or equines, is the occurrence of intra-articular lesions. The equines are each time more required in his athletic performance, resulting in intense stress to the structures that composes the locomotor device. The leading cause of human and equine athlete’s functional incapacity is the intra-articular disorders. One of the greatest advances in sports medicine was the development of arthroscopy as a minimal invasive intra-articular surgery. The defining characteristic of diagnostic or surgical arthroscopy is featured by minimal tissue damage and broad inspection of internal structures inside the joint associated with low morbidity and complications. The advantages of surgical arthroscopy over traditional surgery are well known: limited hospitalization, early return to competition, lower risks of post-operative joint rigidity, magnification of inspected structures, joint lavage associated or not with removal of potentially dangerous substances. Arthroscopy cannot replace conventional methods and must not do so; however, the intrinsic limitations of conventional diagnostic techniques, such as radiology and synovial fluid analysis, must be kept in mind, particularly in evaluating damage to cartilage and the synovial membrane. Arthroscopy has now become the accepted method of performing all joint surgery, however it is mainly used for radical surgery, such as osteochondral fragment removal, surgical curettage and arthroplasty
Resumo:
This work reports the experimental evaluation of physical and gas permeation parameters of four spinel-based investments developed with or without inclusion of sacrificial fillers. Data were compared with those of three commercial formulations. Airflow tests were conducted from 27 to 546°C, and permeability coefficients were fitted from Forchheimer's equation. Skeletal densities found for spinel- (ρs = 3635 ± 165 kg/m3) and phosphate-bonded (ρs = 2686 ± 11 kg/m3) samples were in agreement with the literature. The developed investments were more porous and less permeable than commercial brands, and the differences were ascribed to the different pore morphologies and hydraulic pore sizes of ceramic matrices. The inclusion of both fibers and microbeads resulted in increases of total porosity (42.6–56.6%) and of Darcian permeability coefficient k1 (0.76 × 10−14–7.03 × 10−14 m2). Air permeation was hindered by increasing flow temperatures, and the effect was related to the influence of gas viscosity on ΔP, in accordance with Darcy's law. Casting quality with molten titanium (CP Ti) was directly proportional to the permeability level of the spinel-based investments. However, the high reactivity of the silica-based investment RP and the formation of α-case during casting hindered the benefits of the highest permeability level of this commercial brand.
Resumo:
Objective: Is it feasible to learn the basics of wet mount microscopy of vaginal fluid in 10 hours?Materials and Methods: This is a pilot project wherein 6 students with different grades of education were invited for being tested on their ability to read wet mount microscopic slides before and after 10 hours of hands-on training. Microscopy was performed according to a standard protocol (Femicare, Tienen, Belgium). Before and after training, all students had to evaluate a different set of 50 digital slides. Different diagnoses and microscopic patterns had to be scored. kappa indices were calculated compared with the expert reading. Results: All readers improved their mean scores significantly, especially for the most important types of altered flora (p < .0001). The mean increase in reading concordance (kappa from 0.64 to 0.75) of 1 student with a solid previous experience with microscopy did not reach statistical significance, but the remaining 5 students all improved their scores from poor performance (all kappa < 0.20) to moderate (kappa = 0.53, n = 1) to good (kappa > 0.61, n = 4) concordance. Reading quality improved and reached fair to good concordance on all microscopic items studied, except for the detection of parabasal cells and cytolytic flora. Conclusions: Although further improvement is still possible, a short training course of 10 hours enables vast improvement on wet mount microscopy accuracy and results in fair to good concordance of the most important variables of the vaginal flora compared to a reference reader.
Resumo:
The non-linear evolution of nearly one-dimensional undamped waves in a viscous fluid adequately heated from below is shown to be governed by the Kadomtsev-Petviashvili equation. Its solitary-wave solution is explicitly shown. © 1990.
Resumo:
Alcohol levels were measured in 15 cerebrospinal fluid (CSF) samples and 14 blood samples from grade III and IV male alcoholic patients with signs of nervous system involvement, and compared with levels detected in 11 CSF samples and 11 blood samples from abstemious patients or patients with grade I or II alcoholism whose CSF had been found to be normal by routine analysis (controls). Among the alcoholic patients, alcohol levels were lower in the CSF than in blood, whereas the opposite was true for the controls. The possible mechanisms underlying this difference are discussed and the need for further study of this topic is emphasized.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The purpose of this study was to compare the pharmacokinetics of tetracycline in plasma, synovial fluid, and milk following either a single systemic intravenous (i.v.) injection or a single i.v. regional antibiosis (IVRA) administration of tetracycline hydrochloride to dairy cattle with papillomatous digital dermatitis (PDD). To this end, plasma and synovial fluid tetracycline concentrations were compared with the minimal inhibitory concentration (MIC) values of the major bacteria, which are known to cause digital diseases and thus assess its efficacy in PDD. Residual tetracycline concentrations in milk from cows treated by both methods were also determined. Twelve Holstein cows with various stages of PDD were randomly assigned to two groups of six animals. Group 1 received a single systemic i.v. injection of 10 mg/kg of tetracycline hydrochloride. Group 2 received 1000 mg of tetracycline hydrochloride by IVRA of the affected limb. Blood, synovial fluid and milk samples were taken prior to tetracycline administration (time 0 control), and then at 22, 45 and 82 min, and 2, 3, 4, 6, 8, 12, 24, 48, 72, 96, and 120 h following drug administration. Tetracycline concentrations were determined by high-performance liquid chromatography. Mean tetracycline plasma and milk concentrations in Group 1 were higher than Group 2. The opposite was observed for synovial fluid concentrations. Group 2 synovial fluid concentrations were higher than the MIC value over 24 h for the bacteria most frequently responsible for claw disease. Compared with i.v. administration, IVRA administration of tetracycline produced very high synovial fluid and low plasma and milk concentrations.
Resumo:
Perioperative fluid therapy remains a highly debated topic. Its purpose is to maintain or restore effective circulating blood volume during the immediate perioperative period. Maintaining effective circulating blood volume and pressure are key components of assuring adequate organ perfusion while avoiding the risks associated with either organ hypo- or hyperperfusion. Relative to perioperative fluid therapy, three inescapable conclusions exist: overhydration is bad, underhydration is bad, and what we assume about the fluid status of our patients may be incorrect. There is wide variability of practice, both between individuals and institutions. The aims of this paper are to clearly define the risks and benefits of fluid choices within the perioperative space, to describe current evidence-based methodologies for their administration, and ultimately to reduce the variability with which perioperative fluids are administered. Based on the abovementioned acknowledgements, a group of 72 researchers, well known within the field of fluid resuscitation, were invited, via email, to attend a meeting that was held in Chicago in 2011 to discuss perioperative fluid therapy. From the 72 invitees, 14 researchers representing 7 countries attended, and thus, the international Fluid Optimization Group (FOG) came into existence. These researches, working collaboratively, have reviewed the data from 162 different fluid resuscitation papers including both operative and intensive care unit populations. This manuscript is the result of 3 years of evidence-based, discussions, analysis, and synthesis of the currently known risks and benefits of individual fluids and the best methods for administering them. The results of this review paper provide an overview of the components of an effective perioperative fluid administration plan and address both the physiologic principles and outcomes of fluid administration. We recommend that both perioperative fluid choice and therapy be individualized. Patients should receive fluid therapy guided by predefined physiologic targets. Specifically, fluids should be administered when patients require augmentation of their perfusion and are also volume responsive. This paper provides a general approach to fluid therapy and practical recommendations.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)